Issue 13, 2022

Microfluidic device for single step measurement of protein C in plasma samples for sepsis prognosis

Abstract

Protein C is a vitamin K dependant protein in plasma that plays an essential role in regulating the coagulation cascade and inflammatory response. As a result of its importance in these roles, it has been suggested as a biomarker for prognosis of patients affected by sepsis. Sepsis is a dysregulated host response to an infection that is the leading cause of mortality in U.S. hospitals and results in the highest cost of hospitalization. It was found that protein C concentration in non-surviving sepsis patients is significantly lower (1.8 μg mL−1) than in survivors and healthy patients who have a protein C concentration of 3.9–5.9 μg mL−1. Current methods for diagnosing sepsis rely on expensive immunoassays or functional assays that require multiple steps for isolation and activation of protein C. We demonstrate in this paper a low cost, single step assay for detection of protein C in blood plasma. This was done by combining isoelectric gates with barium-immobilized metal affinity trapping. The electric field was optimized for use with immobilized metal affinity using COMSOL simulation. The integrated device was tested with samples containing buffered protein C, protein C in the presence of high concentration bovine serum albumin and alpha 1-proteinase inhibitor, and in blood plasma with spiked protein C. The stability of the measured values was tested by monitoring the intensity of a mixture of protein C with BSA and A1PI every minute to determine that measurement after 40 minutes was optimal. The results showed that the device could be used to distinguish a reduction in protein C from 4.46 μg mL−1 to 1.96 μg mL−1 with greater than 98% confidence in plasma making it suitable for sepsis prognosis.

Graphical abstract: Microfluidic device for single step measurement of protein C in plasma samples for sepsis prognosis

Supplementary files

Article information

Article type
Paper
Submitted
29 Nov 2021
Accepted
14 May 2022
First published
30 May 2022

Lab Chip, 2022,22, 2566-2577

Microfluidic device for single step measurement of protein C in plasma samples for sepsis prognosis

S. Damodara, J. Arora, D. J. Dwivedi, P. C. Liaw, A. E. Fox-Robichaud, P. R. Selvaganapathy and Canadian Critical Care Translational Biology Group, Lab Chip, 2022, 22, 2566 DOI: 10.1039/D1LC01084K

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.