Volume 1, 2022

Highly crystalline N and S co-doped carbon dots as a selective turn off–on sensor for Cr(vi) and ascorbic acid and a turn off sensor for metanil yellow

Abstract

Highly crystalline N and S co-doped carbon dots (NS CDs) were synthesized by a hydrothermal method using mesaconic acid, ethylenediamine, and sulfuric acid as C, N, and S sources. The prepared NS CDs displayed blue fluorescence emission (λex = 350 nm and λem = 405 nm) and exhibited a high quantum yield of 33%. The synthesized NS CDs were spherical and had a mean particle diameter of 3.5 ± 0.86 nm. The prepared carbon dots have large functional groups on their surface, which makes them have excellent water solubility. NS CDs were used as a selective and sensitive turn off and turn on sensor for detection of Cr(VI) with a linear response ranging from 3 μM to 60 μM with a detection limit of 0.056 μM and ascorbic acid with a linear response ranging from 3 μM to 126 μM with a detection limit of 1 μM. The NS CDs also served as a selective and sensitive turn-off sensor for metanil yellow with a linear response ranging from 3 μM to 130 μM with a detection limit of 0.14 μM. The Cr(VI) recognition mechanism was suggested to be a combination of static quenching and the inner filter effect. At the same time, for the detection of ascorbic acid and metanil yellow, it was proposed to be the inner filter effect. The actual sample application of NS CDs as a nanosensor was studied for detection of metanil yellow as an adulterant in turmeric powder.

Graphical abstract: Highly crystalline N and S co-doped carbon dots as a selective turn off–on sensor for Cr(vi) and ascorbic acid and a turn off sensor for metanil yellow

Supplementary files

Article information

Article type
Paper
Submitted
03 Nov 2021
Accepted
12 Mar 2022
First published
14 Mar 2022
This article is Open Access
Creative Commons BY license

Sens. Diagn., 2022,1, 516-524

Highly crystalline N and S co-doped carbon dots as a selective turn off–on sensor for Cr(VI) and ascorbic acid and a turn off sensor for metanil yellow

A. Abbasi and M. Shakir, Sens. Diagn., 2022, 1, 516 DOI: 10.1039/D1SD00042J

This article is licensed under a Creative Commons Attribution 3.0 Unported Licence. You can use material from this article in other publications without requesting further permissions from the RSC, provided that the correct acknowledgement is given.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements