Issue 3, 2023

Comparison between one and two-dimensional liquid chromatographic approaches for the determination of plasmatic stroke biomarkers by isotope dilution and tandem mass spectrometry

Abstract

This work presents the evaluation of one- and two-dimensional liquid chromatography for the quantification of three stroke outcome predictors in plasma. Isotopically labelled analogues of L-arginine (L-Arg), asymmetric dimethylarginine (ADMA) and symmetric dimethylarginine (SDMA) are used to quantify the three analytes by isotope dilution and tandem mass spectrometry. Chromatographic isotope effects were not observed between natural L-Arg and its 15N-labelled analogue but they were observed between natural ADMA and SDMA and their multiple deuterated analogues. Under these conditions, bidimensional chromatography through the use of an automated multiple heart cutting mode provided unsatisfactory results for ADMA and SDMA due to the different amounts of natural and labelled compounds transferred from the first to the second chromatographic dimension. In contrast, using one dimensional liquid chromatography after a derivatization step to esterify carboxylic groups, chromatographic isotope effects did not alter the initial mass balance as full coelution of natural and labelled analogues or baseline resolution between the analytes was not required. This method was successfully validated following the Clinical & Laboratory Standards Institute guidelines and applied to the analysis of plasma samples from patients who had suffered from an intraparenchymal haemorrhagic stroke.

Graphical abstract: Comparison between one and two-dimensional liquid chromatographic approaches for the determination of plasmatic stroke biomarkers by isotope dilution and tandem mass spectrometry

Supplementary files

Article information

Article type
Paper
Submitted
25 Oct 2022
Accepted
15 Dec 2022
First published
16 Dec 2022

Analyst, 2023,148, 583-593

Comparison between one and two-dimensional liquid chromatographic approaches for the determination of plasmatic stroke biomarkers by isotope dilution and tandem mass spectrometry

A. Cortés Giménez-Coral, P. Rodríguez-González, A. González Gago, E. Cernuda Morollón, E. Lopez-Cancio, B. Prieto García and J. I. García Alonso, Analyst, 2023, 148, 583 DOI: 10.1039/D2AN01750D

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements