Issue 9, 2023

Molecular simulation-guided aptasensor design of robust and sensitive lateral flow strip for cadmium ion detection

Abstract

Lateral flow fluorescence strip (LFFS) aptasensor have been widely used for on-site target detection. However, they are limited by low sensitivity and strong background signals owing to the inappropriate design of molecule probes. Herein, we employed molecular simulations to improve the sensitivity of LFFS by the optimization of the DNA probe length and sequence, which is a critical parameter for the competitive approach of the aptasensor. Simulation results revealed that a probe with 30 nt can maximize the hybridization yield of aptamer to reduce the background signal. More importantly, the simulation results highlighted the Cd2+ concentration-dependent conformational changes in the aptamer. It is essential to block its hybridization with a probe, and consequently, yield sensitive and target concentration-dependent fluorescence signal. Considering these results, we developed a sensitive aptamer-based fluorescent lateral flow strip for rapid Cd2+ detection. The fluorescence intensity of this strip exhibited an excellent linear relationship with the Cd2+ concentration ranging from 63 nM to 1000 nM (R2 = 0.9724). The limit of detection was determined to be 30 nM (S/N = 3). This method was also applied for the detection of Cd2+ in river water samples in the range from 92.9 ± 1.0% to 108.6 ± 1.4%. Moreover, the detected concentration in water samples is below the harmful levels (267 nM) recommended by WHO standards in drinking water. The use of molecular simulations is a significant addition to cost and resource-effective aptasensor development protocol, and it can be readily expanded to design aptasensors for other targets.

Graphical abstract: Molecular simulation-guided aptasensor design of robust and sensitive lateral flow strip for cadmium ion detection

Supplementary files

Article information

Article type
Paper
Submitted
07 Feb 2023
Accepted
17 Mar 2023
First published
20 Mar 2023

Analyst, 2023,148, 1961-1969

Molecular simulation-guided aptasensor design of robust and sensitive lateral flow strip for cadmium ion detection

M. Irfan, G. Murtaza, S. Fu, A. Chen, F. Qu and X. Su, Analyst, 2023, 148, 1961 DOI: 10.1039/D3AN00202K

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements