Issue 16, 2023

Sensitive microscale thermophoresis assay for rapid ochratoxin A detection with fluorescently labeled engineered aptamer

Abstract

Ochratoxin A (OTA) is a widespread mycotoxin that causes contamination in a variety of foodstuffs and environments, inducing great health risks to humans and animals. Rapid and sensitive detection of OTA is necessary for food safety, environmental health, and risk assessment. Herein, we report an aptamer microscale thermophoresis (MST) assay for OTA, with the unique merits of ratiometric analysis, rapid measurement, simple operation, high sensitivity, low sample consumption, and high throughput. A fluorescein (FAM)-labeled high-affinity DNA aptamer with a G-quadruplex and duplex structure was used as the recognition element for OTA, and MST, which measures the fluorescence responses of the sample solution inside capillaries to a mild temperature increase generated by infrared laser heating, was employed for signal generation. Upon OTA binding, the FAM-labeled aptamer probe underwent changes in conformation and stability, and the bound and unbound aptamer probes showed significant differences in their MST signals. To achieve sensitive detection of OTA with a large signal change, we systematically characterized aptamers with different stem lengths, which had large effects on the MST responses of the aptamer probes to OTA. We found that a 32-mer aptamer with FAM label at the 3′ end gave a sensitive MST response to OTA, allowing OTA detection within seconds with a detection limit of 0.98 nM under optimal experimental conditions. This aptamer MST assay shows potential in real sample analysis and broad applications.

Graphical abstract: Sensitive microscale thermophoresis assay for rapid ochratoxin A detection with fluorescently labeled engineered aptamer

Supplementary files

Article information

Article type
Paper
Submitted
30 May 2023
Accepted
05 Jul 2023
First published
08 Jul 2023

Analyst, 2023,148, 3876-3882

Sensitive microscale thermophoresis assay for rapid ochratoxin A detection with fluorescently labeled engineered aptamer

H. Yu and Q. Zhao, Analyst, 2023, 148, 3876 DOI: 10.1039/D3AN00867C

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements