A disposable and sensitive sensor based on a ZIF-8@graphene modified carbon paper electrode for the quantitative determination of luteolin†
Abstract
Rapid and accurate determination of luteolin is of great significance for pharmaceutical quality control. Herein, a disposable and sensitive luteolin sensor was fabricated by a hydrothermal method with carbon paper as substrate where ZIF-8 grew on GR in situ. Notably, the large specific surface area of ZIF-8 provided active sites on the electrode surface and the ability of GR to promote electron transfer greatly improved the sensitivity towards the oxidation of luteolin. Under the optimum conditions, the ZIF-8@GR/CP showed excellent detection performance for luteolin with a linear detection range of 0.04–3.2 μM and 3.2–120 μM, with LOD of 12 nM (S/N = 3). Furthermore, this disposable and sensitive sensor was successfully applied for the quantitative detection of luteolin in a capsule of Lamiophlomis rotata.