Issue 23, 2023

A label-free electrochemical immunosensor based on decorated cellulose nanofibrous membrane for point-of-care diagnosis of amanitin poisoning via human urine

Abstract

α-Amanitin (AMN) is one of the deadliest toxins from mushrooms, present in the deadly mushroom species Amanita phalloides. It is a bicyclic octapeptide and represents up to 40% of the amatoxins in mushrooms, damaging the liver and kidneys. Current methods of detecting amatoxins are time-consuming and require the use of expensive equipment. A novel label-free electrochemical immunosensor was successfully developed for rapid detection of α-amanitin, which was fabricated by immobilization of anti-α-amanitin antibodies onto a functionalized cellulose nanofibrous membrane-modified carbon screen-printed electrode. An oxidation peak of the captured amanitin on the tethered antibodies was observed at 0.45 V. The performance of the nanofibrous membrane on the electrode and necessary fabrication steps were investigated by electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV). Due to its unique structural features and properties such as high specific surface area and microporous structure, the nanofibrous membrane as an immunosensor matrix for antibody tethering improved the electrochemical performance of the immunosensor by more than 3 times compared with cast membranes. Under the optimal conditions, the assembled immunosensor exhibited high sensitivity toward α-amanitin detection in the range of 0.009–2 ng mL−1 with a limit of detection of 8.3 pg mL−1. The results clearly indicate that the fabricated nanofiber-based-immunosensor is suitable for point-of-care detection of lethal α-amanitin in human urine without any pretreatment within 30 min.

Graphical abstract: A label-free electrochemical immunosensor based on decorated cellulose nanofibrous membrane for point-of-care diagnosis of amanitin poisoning via human urine

Supplementary files

Article information

Article type
Paper
Submitted
12 Jun 2023
Accepted
15 Oct 2023
First published
31 Oct 2023

Lab Chip, 2023,23, 5009-5017

Author version available

A label-free electrochemical immunosensor based on decorated cellulose nanofibrous membrane for point-of-care diagnosis of amanitin poisoning via human urine

A. Y. El-Moghazy, N. Amaly, N. Nitin and G. Sun, Lab Chip, 2023, 23, 5009 DOI: 10.1039/D3LC00508A

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements