Issue 5, 2023, Issue in Progress

Fast and selective reversed-phase high performance liquid chromatographic separation of UO22+ and Th4+ ions using surface modified C18 silica monolithic supports with target specific ionophoric ligands

Abstract

Reprocessing nuclear-spent fuels is highly demanded for enhanced resource efficacy and removal of the associated radiotoxicity. The present work elucidates the rapid separation of UO22+ and Th4+ ions using a reversed-phase high-performance liquid chromatographic (RP-HPLC) technique by dynamically modifying the surface of a C18 silica monolith column with target-specific ionophoric ligands. For the dynamic modification, four analogous aromatic amide ligands, N1,N1,N3,N3,N5,N5-hexa(alkyl)benzene-1,3,5-tricarboxamide (alkyl = butyl, hexyl, octyl, and decyl) as column modifiers were synthesized. The complexation properties and retention profiles of the amide-based column modifiers for the selective and sequential separation of UO22+ and Th4+ ions were investigated. In addition, the selective separation of UO22+ and Th4+ ions among the competitive ions of similar chemical properties were also studied. The ionophore immobilized C18 silica monolith columns demonstrated a varying degree of retention behavior for UO22+ and Th4+ ions (UO22+ is retained longer than Th4+ under all analytical conditions), eventually leading to rapid separations within a period of ≤5 min. A 0.1 M solution of 2-hydroxyisobutyric acid (HIBA, 1 mL min−1) served as the mobile phase, and the qualitative and quantitative assessment of the sequentially separated 5f metal ions was achieved through post-column derivatization reaction, using arsenazo(III) as a post-column reagent (PCR; 1.5 mL min−1) prior to analysis using a UV-vis detector, at 665 nm (λmax). The developed technique was further evaluated by standardizing various analytical parameters, including modifier concentration, mobile phase pH, mobile phase flow rate, etc., to yield the best chromatographic separation. Also, the conceptual role of alkyl chain length (in the modifier) on the retention behavior of the studied metal ions was evaluated for cutting-edge future applications.

Graphical abstract: Fast and selective reversed-phase high performance liquid chromatographic separation of UO22+ and Th4+ ions using surface modified C18 silica monolithic supports with target specific ionophoric ligands

Supplementary files

Article information

Article type
Paper
Submitted
25 Nov 2022
Accepted
12 Jan 2023
First published
23 Jan 2023
This article is Open Access
Creative Commons BY license

RSC Adv., 2023,13, 3317-3328

Fast and selective reversed-phase high performance liquid chromatographic separation of UO22+ and Th4+ ions using surface modified C18 silica monolithic supports with target specific ionophoric ligands

A. Kongasseri, T. Madhesan, S. Mitra, C. V. S. B. Rao, S. Nagarajan, P. K. Chinaraga, P. Deivasigamani and A. M. Mohan, RSC Adv., 2023, 13, 3317 DOI: 10.1039/D2RA07495H

This article is licensed under a Creative Commons Attribution 3.0 Unported Licence. You can use material from this article in other publications without requesting further permissions from the RSC, provided that the correct acknowledgement is given.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements