Issue 26, 2023, Issue in Progress

Investigation of organophosphorus (OPs) compounds by a needle trap device based on mesoporous organo-layered double hydroxide (organo-LDH)

Abstract

Organophosphorus (OPs) compounds can endanger human health and the environment by inhibiting the acetylcholinesterase enzyme. But these compounds have been widely used as pesticides due to their effectiveness against all kinds of pests. In this study, a Needle Trap Device (NTD) packed with mesoporous organo-layered double hydroxide (organo-LDH) material and coupled with gas chromatography-mass spectrometry (GC-MS) was employed for the sampling and analysis of OPs compounds (diazinon, ethion, malathion, parathion, and fenitrothion). In this way, the [magnesium–zinc–aluminum] layered double hydroxide ([Mg–Zn–Al] LDH) modified with sodium dodecyl sulfate (SDS) as a surfactant was prepared and characterized by FT-IR, XRD, BET, and FE-SEM, EDS, and elemental mapping techniques. Then, various parameters such as relative humidity, sampling temperature, desorption time, and desorption temperature were evaluated by the mesoporous organo-LDH:NTD method. The optimal values of these parameters were determined using response surface methodology (RMS) and central composite design (CCD). The optimal temperature and relative humidity values were obtained as 20 °C and 25.0%, respectively. On the other hand, the desorption temperature and time values were in the range of 245.0–254.0 °C and 5 min, respectively. The limit of detection (LOD) and limit of quantification (LOQ) were reported in the range of 0.02–0.05 mg m−3 and 0.09–0.18 mg m−3, respectively, which shows the high sensitivity of the proposed method compared to the usual methods. The repeatability and reproducibility of the proposed method (by calculating the relative standard deviation) was estimated in the range of 3.8–10.10 which indicates the acceptable precision of the organo-LDH:NTD method. Also, the desorption rate of the stored needles at 25 °C and 4 °C, was determined to be 86.0% and 96.0%, respectively after 6 days. The results of this study proved that the mesoporous organo-LDH:NTD method can be utilized as a fast, simple, environmentally friendly, and effective method for sampling and determining OPs compounds in the air.

Graphical abstract: Investigation of organophosphorus (OPs) compounds by a needle trap device based on mesoporous organo-layered double hydroxide (organo-LDH)

Supplementary files

Article information

Article type
Paper
Submitted
16 Mar 2023
Accepted
26 May 2023
First published
12 Jun 2023
This article is Open Access
Creative Commons BY license

RSC Adv., 2023,13, 17656-17666

Investigation of organophosphorus (OPs) compounds by a needle trap device based on mesoporous organo-layered double hydroxide (organo-LDH)

R. Rahimpoor, D. soleymani-ghoozhdi, S. Alizadeh, A. Firoozichahak, F. Mehregan and R. Firoozi, RSC Adv., 2023, 13, 17656 DOI: 10.1039/D3RA01732J

This article is licensed under a Creative Commons Attribution 3.0 Unported Licence. You can use material from this article in other publications without requesting further permissions from the RSC, provided that the correct acknowledgement is given.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements