Exploration of the impact of graphene oxide, acetylenic gemini, and CTAT on the photophysical and aggregation properties of dipolar coumarin 153†
Abstract
Advanced spectroscopic techniques have been utilized to study the interaction between the laser dye coumarin 153 (C153) and graphene oxide (GO) nanoparticles. GO was synthesized using a modified Hummers' method and characterized by UV-vis spectroscopy, Raman laser spectroscopy, FTIR-ATR spectroscopy, FESEM, HR-TEM, and XRD techniques. The GO@C153 composite was formed by mixing two aqueous solutions of GO and C153 due to their strong interaction through stacking and hydrophobic interactions. In this case, GO acts as an effective fluorescence quencher for C153 molecules, which undergo H-type aggregation in the presence of GO. The Stern–Volmer equation and time-dependent fluorescence studies were utilized to analyse the mechanism of fluorescence quenching. According to the findings, both static and dynamic quenching processes are responsible for the reduction in fluorescence intensity. The effect of surfactants (both cetyltrimethylammonium p-toluenesulfonate (CTAT) and synthesized N,N′-dihexadecyl-N,N,N′,N′-tetramethyl-N,N′-but-2-ynediyl-di-ammonium chloride (16-4-16)) on the aggregation and photophysical properties of the dye was investigated using surface tensiometry, conductometry, UV-vis absorption spectroscopy, steady-state fluorescence measurements, DLS, and time-dependent fluorescence spectroscopy. Surfactants change the microenvironment of the C153 dye, leading to spectrum shifting and a higher quantum yield, which causes a rapid rise in fluorescence intensity in the micellar medium. It has been noted that in a micellar medium rather than in an aqueous one, the luminous intramolecular charge transfer (ICT) state of C153 stabilises. Lastly, we investigated the photophysical behavior of the GO–C153–micelle ternary system and discovered that, in the presence of a micellar medium, the quenched and blue-shifted (H-type aggregation) fluorescence peak of C153 (in the presence of GO) began to intensify once more. The main goal of this work is to create an effective and fairly cost powerful fluorescence sensor. Additionally, the ternary system (GO–C153–micelle) analytical idea can be employed to identify the onset of micelle formation. In wastewater treatment analysis, the GO–C153–surfactant ternary system concept can also be used to regenerate the adsorbent (in this case, GO) from dye molecules by allowing the dye molecules to exit the adsorbent and enter the micellar medium.