Issue 45, 2024

An ESIPT-active orange-emissive 2-(2′-hydroxyphenyl)imidazo[1,2-a]pyridine-derived chemodosimeter for turn-on detection of fluoride ions via desilylation

Abstract

Fluoride is an essential element for oral health with an optimum concentration of 0.7–1.2 ppm in drinking water, but it is detrimental at higher concentrations, causing fluorosis, acute gastric ulcer, urolithiasis, and kidney infection, which adds immense significance to its detection in water sources. In the current study, a new chemodosimeter (HIPS-Br) is designed by protecting a 2-(2′-hydroxyphenyl)imidazo[1,2-a]pyridine derivative (HIP-Br) with a fluoride recognizable tert-butyldiphenylsilane moiety and utilized for the selective detection of F ions by an excited-state intramolecular proton transfer (ESIPT)-based fluorimetric response. The probe HIPS-Br exhibits blue fluorescence in solution, and upon the incremental addition of F ions, it exhibits a turn-on response, exhibiting a strong orange emission at 598 nm by spontaneous cleavage of the tert-butyldiphenylsilane group to release fluorescent HIP-Br in the working solution. HIPS-Br displayed no or insignificant response towards numerous common anions, cations and small molecules, affirming its selectivity to F ions and offered a low limit of detection (LOD) of 1.2 ppb (6.6 × 10−8 M). The real sample analysis by spiking fluorides in water and toothpaste samples showed excellent percent recoveries. The chemodosimeter was successfully utilized in the solid-phase detection of F ions on silica-coated TLC plates and analyzed by ImageJ analysis, marking its utility in on-site quantitation purposes.

Graphical abstract: An ESIPT-active orange-emissive 2-(2′-hydroxyphenyl)imidazo[1,2-a]pyridine-derived chemodosimeter for turn-on detection of fluoride ions via desilylation

Supplementary files

Article information

Article type
Paper
Submitted
11 Aug 2024
Accepted
09 Oct 2024
First published
21 Oct 2024
This article is Open Access
Creative Commons BY-NC license

RSC Adv., 2024,14, 33312-33322

An ESIPT-active orange-emissive 2-(2′-hydroxyphenyl)imidazo[1,2-a]pyridine-derived chemodosimeter for turn-on detection of fluoride ions via desilylation

A. A. Bhosle, M. Banerjee, A. Thakuri, P. D. Vishwakarma and A. Chatterjee, RSC Adv., 2024, 14, 33312 DOI: 10.1039/D4RA05823B

This article is licensed under a Creative Commons Attribution-NonCommercial 3.0 Unported Licence. You can use material from this article in other publications, without requesting further permission from the RSC, provided that the correct acknowledgement is given and it is not used for commercial purposes.

To request permission to reproduce material from this article in a commercial publication, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party commercial publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements