Dan
Li
,
Qing
Zheng
,
Yanwei
Wang
* and
Hong
Chen
*
Jiangsu Key Laboratory of Advanced Functional Polymer Design and Application, Department of Polymer Science and Engineering, College of Chemistry, Chemical Engineering and Materials Science, Soochow University, 199 Ren'ai Road, Suzhou 215123, P. R. China. E-mail: ywwang@suda.edu.cn; chenh@suda.edu.cn; Fax: +86-512-65880583; Tel: +86-512-6588082
First published on 29th July 2013
The review focuses on the combination of surface topography and surface chemical modification with the grafting of polymer chains to develop optimal material interfaces for biological and biomedical applications. Understanding how surface chemistry and topography correlate with the interfacial properties and biological functions of a material is important for the development of biomaterials. Synergies between these two properties are known to exist, but have not been exploited extensively for biomaterial design. Preliminary studies suggest that the combination of surface topography and chemistry may not only enhance surface properties, but may also give biological properties that are opposite to those of the corresponding smooth surface, and even other unexpected biological properties. This review summarizes some recent studies in this area, mostly carried out in our own laboratory, as examples to illustrate how synergistic properties and functions may be obtained by combining surface topography with polymer chemistry. It is hoped that this review will stimulate a more thorough exploration of the topography–chemistry synergy as a means of injecting “new life” into efforts to develop novel bio-functional surfaces.
In addition to surface chemistry, topography is also known to substantially affect the bulk properties of a material.6,7,30,31 For example, the introduction of nanostructure makes a hydrophobic surface more hydrophobic, and makes a hydrophilic surface more hydrophilic, as first explained by the Wenzel model.32–35 For biological applications, the introduction of surface topography usually increases the area of contact, which is essential for drug release, bio-separation and bio-detection applications. Indeed, surface topography may enhance biological properties that originate from surface chemistry. For instance, the surface of Pluronic®-blended polyurethane is protein-resistant, and introducing lotus leaf-like topography can further reduce proteinadsorption even though the effective surface area is increased.36 There are also examples of the opposite behaviour. A nano-structured surface coated with fluorinated polyurethane showed low platelet adhesion and activation, while the corresponding smooth surface showed very high platelet adhesion and activation, and such an improvement in biocompatibility was attributed to the special nanostructure and the superhydrophobicity derived from it.37 Therefore, the combined effects of surface chemistry and surface topography can be complicated and can lead to effects other than the simple enhancement of the individual effects.
Understanding how surface chemistry and topography correlate with the interfacial properties and biological functions of a material is critical for the design and development of novel biomaterials. It requires research and exploration involving different areas: creating surfaces with well-defined micro-, nano- and hierarchical structures,38–43 controlled surface chemical modification,44–50 characterization of surface topography and surface chemistry,13,51–53 and quantification of the materials’ biological performance at the biointerface.54,55 All these are active research areas. Among them, polymers are playing an increasingly important part both in the preparation of well-defined surface structures and in controlled surface chemical modification.21,24,44,45,56 In particular, immobilizing polymer chains on a solid surface can not only bring rich chemical properties to the surface, but can also alter mechanical properties and environmental responses of the surface.57–60 Moreover, polymer chains can often be easily functionalized, which result in the possibility of binding specific ligands to induce desired biological responses for a variety of biomedical applications.
Recent technologies for creating surfaces with well-defined topography and chemistry combined with sensitive surface characterization techniques have unquestionably deepened our understanding of surface chemical and topographical effects on cell behaviour. Synergistic properties and functions between surface chemistry and topography are known to exist,61–64 but have not been exploited extensively for biomaterial design purposes. In recent years, our laboratory has investigated the synergistic effects of topography and surface chemistry on the interactions of surfaces with biological systems, especially with proteins and cells. Two kinds of topographical surfaces have been studied: porous gold and vertically-aligned nanowire arrays. In this review, these two kinds of topographical surface will be used as examples to illustrate the synergy of surface topography with polymer chemistry. Other types of topographical surface are under investigation in various laboratories including surfaces prepared by soft lithography, etching, self-assembly, etc.65,66 These will not be discussed here.
This review is organized as follows. First, an overview of polymer chemistry for surface modification is given (section 2), followed by a brief summary of methods for the preparation and analysis of topographical surfaces (section 3). We will not go into detail in these two sections since several excellent reviews are already available.41–50 Instead, the focus will be on recent efforts to explore the synergistic effects of surface topography and chemical modification by polymer grafting. This is done in section 4 using examples involving judicious combinations of surface topography and polymer chemistry to provide specific interfacial biological functions. The review concludes with a brief discussion of future perspectives (section 5).
As depicted in Fig. 1, both physical and chemical methods are available for the immobilization of thin layers of polymers on solid surfaces. Early work focused on physisorption.68–71 A classical example is the physisorption of polystyrene-b-poly(ethylene oxide) (PS-b-PEO) from a toluene solution to a mica surface. The PEO segments are preferentially adsorbed to the mica while the PS blocks interact preferentially with the solvent. Another example is the layer-by-layer assembly of polyelectrolyte multilayers by the alternative adsorption of polycations and polyanions via electrostatic interactions, which has been shown to be suitable for modifying the surface properties of biomaterials.72–74 Although the physisorbed blocks can be unstable under certain conditions of solvent and temperature and can be displaced by other adsorbents, this method remains attractive because of its simplicity.
Fig. 1 Schematic illustration of different methods for immobilizing polymer chains on solid surfaces: physisorption, “grafting-to” and “grafting-from” (surface initiated polymerization). |
The covalent bonding of polymer chains to surfaces has attracted interest because of the relative stability of the layers. In general, covalently attached polymer layers can be prepared by either the “grafting-to” or the “grafting-from” method (see Fig. 1).44,67 “Grafting-to” involves the chemical reaction of preformed, functionalized polymers with surfaces containing complementary functional groups. The main advantages of this method are simplicity and the possibility to characterize the preformed polymers in detail. Grafting can be performed using polymer solutions or melts and, in general, higher concentrations of polymer lead to higher grafting densities, but it has been argued that “grafting-to” cannot produce dense polymer layers (brushes) because the attachment of new chains may be impeded by the presence of previously attached chains. This problem is avoided in the “grafting-from” method, which involves the in situpolymerization of the monomer on an initiator functionalized surface. Many living and conventional vinylpolymerization techniques have been applied using this method.45,46,48 The graft density is determined by the initiator density which can be relatively high since the initiator is generally of a small size. The “grafting-from” technique may suffer complications because of low initiator efficiency, and the variable rate of diffusion of monomer to active polymerization sites. Side reactions may be more important than in bulk polymerization because of the high local concentration of polymer chains in the grafted layers; e.g., bimolecular termination in radical polymerization.75–78 Hence, “grafting-from” may lead to a broader chain length distribution.
While most of the syntheses of polymer brushes reported in the literature were conducted on flat surfaces, brushes can also be formed on surfaces with topographic features as demonstrated by work in our laboratory (see section 4). Surface topography may affect the polymerization kinetics, but this aspect has not been studied to any significant extent, either experimentally or theoretically.
A variety of methods have been developed to characterize the surface chemistry of polymer-modified flat surfaces. Chemical composition can be analyzed by X-ray photoelectron spectroscopy (XPS), infrared spectroscopy and time-of-flight secondary ion mass spectrometry (TOF-SIMS). A useful technique for qualitative and quantitative characterization of surface chemistry on a solid substrate with complex topography is transmission mode Fourier transform infrared (FTIR) spectroscopy. If the substrate does not appreciably absorb light near the characteristic frequency of the C–H stretching peak, which is the footprint of carbon–hydrogen bonds in polymer chains, then by proper calibration the measured FTIR absorbance peak can be used to calculate the amount of polymer on the substrate. For qualitative characterization of surface chemistry, contact angle measurements are extremely useful and can be conducted both on flat and rough surfaces. Ellipsometry is a convenient and accurate tool to determine the thickness of polymer thin films. However, the accuracy of the measurement of film thickness is limited when the substrate is rough. For polymer-modified topographical surfaces, atomic force spectroscopy (AFM),79 and in some cases, transmission electron microscopy (TEM), can give accurate measurements of film thickness.64
Topography may be introduced at the surface of a material by different patterning strategies, such as photolithography, scanning beam lithography, molding, embossing, printing and self-assembly.41,43 It may also be introduced by the inherent relaxation of the material, or by mechanical roughening and wet chemical etchingetc.30 Recent studies in our laboratory have focused on two kinds of topographical surface (see Fig. 2), namely gold nanoparticle layers (GNPL) and vertically-aligned nanowire arrays, such as silicon nanowire arrays (SiNWAs). Details of the preparation, characterization and applications of those two types of surfaces are available in the literature (for GNPL79,82–84 and for SiNWAs62,64,85–91).
Fig. 2 Schematic illustration and SEM images of two kinds of topographical surfaces studied in our laboratory: (a) gold nanoparticle layers (GNPL) and (b) silicon nanowire arrays (SiNWAs). |
The characterization of surface topography is of key importance when investigating the effects of various topographies on the interactions with biological objects. This includes the measurements of surface roughness, specific surface area, scale and shape of the feature, etc. For regular surface topographies, such properties can be obtained by microscopic techniques. However, the characterization becomes more difficult in the case of irregular ones. Surface roughness is an important parameter that can characterize an irregular topographical surface. There exist different types of roughness measurement apparatus such as the atomic force microscope (AFM), stylus profilometer, and optical apparatus.13 In particular, AFM offers an incomparable resolution and is the ideal tool to describe topography at the nanometre scale. The most often used roughness parameters in the biomaterials field are the arithmetic average roughness, Ra, and the root mean square roughness, Rq. However, it should be noted that the value of a roughness parameter depends on the scale of the measurement. An example is shown in Fig. 3, where roughness parameters Ra and Rq were obtained from AFM height images and then plotted as a function of the evaluation length. This problem was studied in depth by Bigerelle et al.,13,53 and a multi-scale roughness parameter evaluation method was developed in their studies to obtain more detailed descriptions of the surface topography.
Fig. 3 AFM height images of GNPL surfaces for different evaluation lengths: (a–h) 2, 5, 10, 20, 50, 80, 100, and 120 μm and (i) roughness parameters Rq and Ravs. evaluation length as a description of the surface topography. Adapted with permission from ref. 79. Copyright 2012 American Chemical Society. |
In a preliminary study to investigate the synergy of GNPL topography with bio-inert polymer modification, we carried out proteinadsorption and cell adhesion measurements on POEGMA-modified GNPL surfaces.79 POEGMA chains were immobilized on GNPL surfaces by surface-initiated atom transfer radical polymerization (SI-ATRP). It was found that similarly low amounts of cell-adhesive proteins were adsorbed on POEGMA-modified smooth and topographical surfaces, while the cell density on the GNPL–POEGMA surface was much higher than on the corresponding smooth surface (see Fig. 4). This result indicates that the GNPL topography can promote cell adhesion even though the surface chemistry does not favour the adsorption of cell-adhesive proteins. However, it was found that minimal amounts of adsorbed protein are necessary to support initial cell adhesion. Although cell spreading was constrained because of the lack of adsorbed proteins, the cells were more firmly attached and more stable than those on the POEGMA-modified smooth surface.79 From this study it was concluded that on the POEGMA-modified GNPL surface, POEGMA inhibited cell spreading by limiting proteinadsorption, while the GNPL topography promoted cell adhesion and stability on the surface. Surface topography and surface chemistry thus appear to affect different aspects of cell–surface interactions. In a follow-up study the cell adhesive peptide GRGDY was introduced to the surface using POEGMA as a bioinert spacer.99 This surface was shown to be strongly protein-resistant but also strongly cell-adhesive, presumably due to GRGDY–cell receptor interactions.
Fig. 4 Fluorescence and SEM images (scale bar = 50 μm) of L02 and BEL-7402 cells on surfaces. Cells that are spreading on the GNPL surface are marked by red ovals in B3 and D3. The shape and filopodia of the cells on POEGMA-modified surfaces were observed by confocal microscopy and are shown as insets in A2, A4, C2, and C4 (scale bar = 10 μm). The column headings (from left to right), smooth Au, sAu–POEGMA, GNPL and GNPL–POEGMA, refer to a smooth gold surface, a POEGMA-modified smooth gold surface, a GNPL surface and a POEGMA-modified GNPL surface, respectively. Reprinted with permission from ref. 79. Copyright 2012 American Chemical Society. |
What is the effect of surface topography on the stimuli-responsiveness of such smart polymers when they are immobilized on a solid surface? Previous reports have shown that the stimuli-responsiveness of surface wettability can be greatly enhanced by introducing nanoscale roughness,31,33 but how about proteinadsorption and other bio-related properties? Can their stimuli-responsiveness be enhanced as well when nanoscale topography is introduced on substrate surfaces?
Surfaces modified with polyelectrolytes are believed to have great potential for the controlled binding and release of proteins because of their pH-responsive properties.100 As shown in Fig. 5, by combining nanostructured SiNWAs with the pH responsiveness of poly(methacrylic acid) (PMAA), which is a typical weak polyacid, we achieved not only an extremely high capacity for lysozyme binding at pH 4 (∼80-fold increase compared to PMAA-modified smooth silicon, presumably due to an enlarged surface area in the case of SiNWAs), but also an enhancement effect for the pH responsiveness.100 Notably, increasing the pH to 9 resulted in the release of ∼90% of the adsorbed lysozyme without loss of protein activity. The effect of pH change from 4 to 9 on lysozyme adsorption on the nanostructured surface was greater by a factor of ∼70 compared to the smooth Si–PMAA surface.
Fig. 5 (a) Schematic illustration of the pH-responsive conformation change and proteinadsorption properties of PMAA grafted on SiNWAs surface. (b) Adsorption of lysozyme from phosphate-buffered saline (PBS) at pH = 4 and pH = 9. A comparison is made between Si–PMAA and SiNWAs–PMAA, which refer to PMAA-modified smooth silicon and PMAA-modified SiNWAs surfaces, respectively. |
In another study,101 step-wise control of proteinadsorption and bacterial attachment was achieved on poly[2-(N,N′-dimethylamino)ethyl methacrylate] (PDMAEMA)-grafted silicon nanowire arrays by varying the ionic strength. Furthermore, quaternization of the PDMAEMA gave a high concentration of positive charges on the surface, which was then found to be strongly anti-bacterial. Bacterial adhesion on the quaternized SiNWAs–PDMAEMA surface was much higher than on the analogous smooth surface ((34.6 ± 0.39) × 106vs. (5.0 ± 0.15) × 106 cells cm−2), and 95% of the adhered cells were killed compared to less than 45% for the smooth surface.87
Poly(N-isopropylacrylamide) (PNIPAAm) is a well-known thermo-responsive polymer with a lower critical solution temperature (LCST) of ∼32 °C. On surfaces modified with PNIPAAm, the surface wettability, proteinadsorption and cell adhesion properties can be controlled by varying the temperature.102,103 It has been demonstrated that the combination of nanostructure and surface grafting of PNIPAAm can enhance the thermal responsiveness of the surface wettability, and reversible switching between super-hydrophilicity and super-hydrophobicity can thus be achieved.34 It is thus expected that the effects of temperature on the biological properties of PNIPAAm-modified surfaces may also be enhanced by the introduction of surface topography. Recent data from our lab, however, do not support this expectation. Fibrinogen adsorption at 23 °C and 37 °C showed no clear difference, and compared with the unmodified arrays, the amount of proteinadsorption was reduced by more than 99% on the PNIPAAm-modified silicon nanowire arrays (SiNWAs–PNIPAAm) surface.62 Similar observations were also obtained for platelet adhesion. Chen et al. found that the SiNWAs–PNIPAAm surface was non-adhesive to platelets both below and above the LCST, while a smooth PNIPAAm surface was non-adhesive only below the LCST.104 This is presumably due to the trapping of water in the interstices of the nanowires resulting in the formation of a strong hydration layer which prevents the adhesion of platelets on the surface. Clearly, the vertically aligned nanoscale topography plays a key role in keeping water molecules on the SiNWAs–PNIPAAm surface.
Interestingly although the PNIPAAm-modified SiNWAs surface did not show thermal responsiveness for the adsorption of native proteins, it was thermally responsive to denatured proteins. We found that denatured proteins were adsorbed selectively to SiNWAs–PNIPAAm from native/denatured protein mixtures of either the same or different proteins.88 Even more interestingly, it was found that by temperature cycling above and below PNIPAAm's LCST (consisting of repeated cycles of 10 °C for 3 min and 40 °C for 3 min), the uptake of denatured protein was further increased, while the amount of native proteins and their enzymatic activity were maintained at nearly their original levels (see Fig. 6). These results may stimulate applications of the SiNWAs–PNIPAAm surface for native/denatured protein separation.
Fig. 6 (a) Schematic illustration of the PNIPAAm-modified silicon nanowire arrays surface (SiNWAs–PNIPAAm) and its interaction with native and denatured proteins at temperatures below the LCST of PNIPAAm (<LCST), above the LCST of PNIPAAm (>LCST), and under temperature cycling conditions. (b) Fluorescence images of the adsorption of denatured lysozyme (denatured LYZ) and native horseradish peroxidase (native HRP) on PNIPAAm-modified SiNWAs and the corresponding fluorescence intensity in the solution phase for different incubation periods (0 h and 4 h). The protein mixture contains denatured LYZ labelled with fluorescein isothiocyanate (green colour) and native HRP labelled with rhodamine (red colour). Adapted with permission from ref. 88. © IOP Publishing. Reproduced by permission of IOP Publishing. All rights reserved. |
The SiNWAs–PNIPAAm surface was also found to have significant and reversible thermo-responsiveness to bacteria (E. coli) with high adhesion at 42 °C and low adhesion at 4 °C; also the attached cells could be almost completely released by decreasing the temperature.64 Taking advantage of this behavior, we used the SiNWAs–PNIPAAm surface as a nano-catalyst to promote DNA transformation; it was shown that the catalytic efficiency was increased by >400-fold compared to traditional methods.64 The achievement of this unique biological function is attributed to the combination of several features of the PNIPAAm-modified SiNWAs as illustrated in Fig. 7. First, the dramatic switch in surface wettability as a function of temperature plays a central role in the highly efficient DNA transformation process. At 4 °C, the surface is strongly hydrophilic and the PNIPAAm chains stretch into the water phase, similar to poly(ethylene glycol) (PEG) in the chemical transformation method. DNA precipitation on the E. coli cell surfaces is thus promoted. Heating to 42 °C (the optimal temperature for DNA transformation) makes the surface strongly hydrophobic, leading to a high cell density and an increasing the number of cells being available to be transformed. After transformation, decreasing the temperature to 4 °C makes the surface super-hydrophilic again and almost all of the cells are released, thus facilitating molecular screening of the transformants and recycling of the nano-catalyst. Second, the relatively high thermal conductivity of silicon is important for DNA transformation. During the transformation process at 42 °C, the plasmid DNA carried by the attached cells can be heat shocked quickly and uniformly, thereby avoiding the problem of non-uniform temperature distribution encountered in the chemical transformation method. In addition, the short transformation time (90 s) at 42 °C helps to preserve the viability of the attached cells for DNA transformation. Coincidentally, almost all of the steps in the transformation process (Fig. 7), including DNA acquisition, cell adhesion, DNA transfer, and transformant release, are facilitated by the SiNWAs–PNIPAAm platform. This is a clear example of achieving an important biological function by combining nano-topography and surface modification with a polymer.
Fig. 7 Schematic illustration of the application of PNIPAAm-modified silicon nanowire arrays (SiNWAs) as an efficient “nano-catalyst” platform for the DNA transformation of E. coli cells. (a) Mixing of DNA (pUC18 plasmid) with E. coli cells just before loading onto the PNIPAAm-modified SiNWAs. (b) Incubation of DNA and E. coli cells at 4 °C with the PNIPAAm-modified SiNWAs and the distribution of DNA on the cell surfaces. (c) Cell adhesion onto the PNIPAAm-modified silicon nanowire arrays at 42 °C. (d) Internalization of DNA into E. coli cells during heat shock. (e) Release of E. coli cells, including transformants, from the material's surface. Reprinted with permission from ref. 64. Copyright 2011 The Royal Society of Chemistry. |
Fig. 8 Two examples of vertically-aligned nano-structured arrays modified with polymers for drug delivery applications. (a) Plasma modification of a porous platform for controlled drug release. The four stages marked with arrows between them show (i) the anodic aluminium oxide (AAO) porous layer fabricated by electrochemical anodization, (ii) drug loading (vancomycin) inside the pores, (iii) the deposition of the plasma polymer layer (allylamine) on the top of the pores, and finally (iv) the release of the drug from the pores into solution. Reprinted with permission from ref. 105. Copyright 2010 The Royal Society of Chemistry. (b) Titania nanotube (TNT/Ti) implants modified with polymer film infrastructure. The four stages marked with arrows between them show (i) the Ti substrate, (ii) the bare TNT layer formed on the Ti substrate by electrochemical anodization, (iii) loading of the drug inside the TNT structures, and (iv) chitosan or PLGA polymer film coated on the TNT by dip coating (thin and thick) with the aim of controlling the drug release and improving the antibacterial properties and bone integration. The scheme shows the diffusion of drug molecules through the polymer matrix. Reprinted with permission from ref. 106. Copyright 2012 Elsevier. |
Vertically-aligned arrays of high aspect ratio are particularly useful for intracellular delivery because the shape of the array elements enables direct physical access to the interior of the cell. The delivery of various “bio-cargos”, including DNAs, RNAs, peptides, proteins and small molecules to a number of cell types has been demonstrated using nanofibre arrays or nanowire arrays.107–111 However, in these experiments the “bio-cargos” were loaded by adsorption to the surface, and hence the total releasable quantity was limited. Park et al. reported a simple intracellular delivery system based on carbon nanosyringe arrays (CNSAs).112 An amphiphilic copolymer was applied to the surface of the nanosyringes so that drug “cargos” could be readily loaded in the hollow cores by capillary action. Using this technology, efficient delivery of DNA and quantum dots to the cytoplasm of cancer cells and human mesenchymal stem cells was demonstrated.
• The scale, shape and arrangement of surface topographical features may give a variety of synergistic effects when modified with polymers.
• The favourable biological properties of polymer modified surfaces may be further amplified by the optimized design of surface topography.
• The combination of surface topography and polymer grafting/coating may amplify the respective functions of the two factors, or suppress the effects of one of them.
• The excellent optical and electrical properties of surfaces resulting from the combination of surface topography and polymer coatings113 may be useful for bio-detection applications.
It is expected that further development in technologies for creating surfaces with well-defined topography and chemistry will continue to promote studies combining surface topography with polymer chemistry to explore new interfacial biological phenomena and functions. For a clear understanding of the combined effects of surface topography and chemistry, the development of sensitive surface characterization techniques is also crucial. Compared to the characterization of polymer chains immobilized on flat surfaces, the characterization of chain length, layer thickness and grafting density of those on topographical surfaces, especially those of random roughness, is inherently more challenging. However, even though we are still far from a clear understanding of the combined effects of surface topography and chemistry, this remains an exciting task for the future, considering the importance of controlling surface interactions with biological substances in the development of biomaterials.
This journal is © The Royal Society of Chemistry 2014 |