Microstructured devices are widely used for manufacturing products that benefit from process intensification, with pharmaceutical products or specialties of the chemical industry being prime examples. These devices are ideally used for processing pure fluids. Where particulate or non-pure flows are involved, processes are treated with utmost caution since related fouling and blocking issues present the greatest barrier to operating microstructured devices effectively. Micro process engineering is a relatively new research field and there is limited understanding of fouling in these dimensions and its underlying processes and phenomena. A comprehensive review on fouling in microstructured devices would be helpful in this regard, but is currently lacking. This paper attempts to review recent developments of fouling in micro dimensions for all fouling categories (crystallization, particulate, chemical reaction, corrosion and biological growth fouling) and the sequential events involved (initiation, transport, attachment, removal and aging). Compared to fouling in macro dimensions, an additional sixth category is suggested: clogging by gas bubbles. Most of the reviewed papers present very specific fouling investigations making it difficult to derive general rules and parameter dependencies, and comparative or critical considerations of the studies were difficult. We therefore used a statistical approach to evaluate the research in the field of fouling in microchannels.
An intensifying process employing a microstructure device is associated with at least one process that occurs at a dimension below 1 mm, and consequently results in very high surface-to-volume ratios. Laminar flow typically results from the combination of characteristic dimensions in the μ-scale and flow velocities that are frequently limited by an acceptable pressure drop. This means low shear stresses are exerted on the fluid. Applied miniaturization also leads to short transport lengths for heat and mass transfer as well as low residence times that can positively affect a wide range of applications. In particular, reactions with fast kinetics, reactions initiated by mixing events or highly temperature sensitive reactions are especially likely to benefit.2 This applies to existing processes for which the advantages are being investigated by companies like BASF and DuPont.3 Likewise, micro process engineering may act as a “process enabler” in situations where the creation of completely new processing routes in micro structures can render production economically viable, having formerly been not feasible in macroscale equipment.2,4
The benefits are, however, at the expense of lower capacities compared to macro equipment. Microstructured devices are therefore suited for products with maximum capacities of 100–1000 t/a: that is, specialties or products of the pharmaceutical industry.5 Particulate flows are another challenge for microstructured devices since the ratio of the characteristic dimension to the particle diameter decreases significantly. This is one of the reasons why fouling – i.e., the unwanted deposition on surfaces – and plugging occur regularly in microstructured devices. The consequences for process performance can be dramatic: fouling layers lead to local constrictions that change flow velocities and increase pressure drops. In microstructured devices with internal numbering-up, i.e., multi-channel apparatuses, maldistributions of the flow can result in spatial and time distribution of relevant process parameters. In the worst case, complete blockages of the microchannels can occur.
Fouling in general is a well-known problem, and one that has been encountered ever since our ancestors domesticated fire.6 Fouled layers cause high financial losses in all industry sectors due to increased transport and installation costs, capital costs for antifouling equipment, fuel costs, maintenance costs and due to production losses.7 In Germany, the loss is equivalent to 0.25% of the gross domestic product, or about six billion €/a. Fouling can also lead to high capital expenditure. For example, heat exchangers have been reportedly oversized by 30% on average to compensate for fouling.7 A desire to overcome such costs have therefore led to increased research efforts to understand macro-scale fouling phenomena.8–13
A comprehensive overview on fouling was first described by Epstein14 in 1983 using a 5 × 5 matrix which was based on the five primary fouling categories and the five successive events during the formation of fouling layers. 26 years later, Wilson updated the matrix and his analysis indicated that progress had been made for all research topics.15
Conversely, fouling in microstructured devices and the underlying phenomena in the dimensions of ≤1000 μm have only been investigated sparsely so far. Although fouling had already been identified by Hessel et al.16 in 2004 as a major barrier to the successful implementation of microstructured devices, only a few research projects have focused on the topic in the subsequent years. These projects led to some very basic design rules and rules of thumb to prevent fouling, such as the design of channels “as small as necessary and beneficial, not as small as possible”.17 Wiles and Watts18 refined that rule for particulate systems and from three examples concluded that plugging occurs when the particle size is larger than 10% of the smallest dimension in the system. Despite all efforts, Hartman stated in 2012 that plugging was still the greatest challenge to the design of continuous processes using micro structured devices.4 This work aims to comprehensively review and assess fouling and plugging in microstructured devices for better understanding of the underlying phenomena, and to enable more efficient equipment design. For structuring purposes, the 5 × 5 matrix invented by Epstein14 for macro-scale processes is applied for the microstructured systems. Membrane fouling is, however, excluded from this review for it differs significantly from microchannels due to the porous nature of the fouling surface combined with the influence of transmembrane flow on the fouling process.19
In each case, a sequence of five events occurs according to the Epstein model,14 see Fig. 1. The initiation phase is a delay period before significant fouling can be recorded. During the transport phase, the fouling reactant is transported from the fluid's bulk flow to the surface followed by the attachment of the key component. Once a component is attached, it will either be removed by hydrodynamic forces or aging of the respective fouling layer will start. The aging process consists of crystal or chemical structure changes. For a detailed description of the fouling categories and the sequential events, see Epstein.14 A 5 × 5 matrix was then compiled by Epstein with fouling categories as column labels and the events as row labels, see Fig. 1.
(1) |
Fouling classification | Thermal fouling resistance Rf [m2 K W−1] |
---|---|
No/low | 0…2 × 10−4 |
Moderate | 3…9 × 10−4 |
Severe | ≥10 × 10−4 |
As the second key parameter, the mass-based fouling resistance refers to the attached mass as detected by the pressure drop across the heat exchanger. The fouling process is divided into several phases, see Fig. 2. The initiation phase is characterized by a thermal fouling resistance of Rf = 0 m2 K W−1 and ends after the initiation time tini. Starting from that point, matter first attaches to the technical surface which leads to an enhanced heat transfer at the beginning and therefore a negative value of Rf. This phase is called the roughness controlled phase and together with the preceding initiation phase, forms the induction phase. It ends after the induction time tind and is followed by the layer growth phase as shown in Fig. 2. It has been shown by Albert et al.20 that a proper accounting of roughness and constriction effects may eliminate negative values of the thermal fouling resistance in macro scale. This provides the basis for a consistent relation between the thermal- and the mass-based fouling resistance. One of the core questions is whether the problem depicted in Fig. 2 also holds for micro system fouling.
Fig. 2 Graphical definition and schematic development of the thermal fouling resistance and the pressure drop over process time. |
Although only a few papers have explored heterogeneous crystallization in micro devices, some of the work was published quite recently which highlights the importance of this fouling mechanism for the operation of micro devices. All of the papers covered crystallization fouling in micro heat exchangers where the micro roughness of the heat transfer surface, such as found at grain boundaries, serve as nucleation sites. The driving force for the formation of crystals is supersaturation in the vicinity of the heated wall. Table 2 lists published works into crystallization fouling in micro devices, specifying in each case the characteristic dimensions (number of channels, width × height × length) of the micro heat exchanger, Reynolds number (eqn (2)), and wall temperature, where available. Missing values, denoted in italics, were calculated wherever possible based on the given information.
(2) |
Ref. | n mc [—] | d h [μm] | Re [—] | T w [°C] |
---|---|---|---|---|
Benzinger (2005)27 | 22 | 800 × 100 × 22000 | 142 | 96 |
Benzinger (2007)26 | 2, 17 | 800 × 100 × 25000 | 110–2540 | 99 |
Brandner (2007)21 | 17 | 178 | 110 | 99 |
Mayer (2012)22 | 1, 12 | 400 × 200 × 24000 | 66–792 | 76 |
Bucko (2012)23 | 12 | 400 × 200 × 24000 | 42–145 | 65–88 |
Mayer (2013)24 | 1, 12, 18 | 400 × 200 × 24000 | 79–792 | 70–83 |
Mayer (2015)25 | 33 | 400 × 400 × 19600 | 51–507 | 78 |
Brandner et al.21 described in very general terms the fouling of CaCO3 in an electrically heated device, which was repeatedly heated up to 80 °C and cooled down. After some time, a significant pressure drop and reduction of heat duty were observed. The apparatus could be regenerated completely by cleaning with citric acid.
Mayer et al.22 used a supersaturated CaCO3 solution in a fluidic heated heat exchanger with one respectively 12 micro channels, operated in counter current flow. They applied six thermocouples in the heat transferring foil to measure the local wall temperature in the flow direction. The flow rate was varied within the laminar flow regime. At low flow rates, the heat flow was reduced by over 50% due to fouling, whereas it decreased by only 27% at higher flow rates. The pressure drop increased up to 60 times compared to the initial value at low flow rates. Fouling was especially intense at the outlet of the salt solution because of the higher temperatures present. Visual observations showed no removal of any fouling. This corresponds with a relatively low calculated wall shear stress compared to the adhesive strength of the crystals on the heat exchanger surface. In all experiments an induction period and an asymptotic behavior, described by a constant Rf after a specific time, were noticed at the beginning and towards the end of a test, respectively.
An asymptotic behavior, i.e., a decrease of the slope of the fouling curve (Rf), can be attributed to gradually decreasing supersaturation due to changing surface temperature in the course of fouling layer formation. The same micro heat exchanger and salt system was used by Bucko et al.,23 with the difference that the Reynolds number and wall temperature were varied. For some experiments they detected a negative value for the fouling resistance during the induction period, which is equivalent to that found in macroscopic heat exchangers, see Fig. 2. The induction time was reduced with increasing wall temperature, flow velocity and salt concentration. Again, removal of crystals was not observed. In later experiments, Mayer et al.24 observed via optical investigation an uneven distribution of the deposits in the parallel channel arrangement which had developed during the experiment. This was due to an inhomogeneous distribution of the heat flux and to a fouling-induced maldistribution of the fluid flow in the parallel channels.
In order to model the kinetics of the crystallization in the above mentioned micro heat exchanger, Bucko et al.23 calculated the Hatta and Damköhler numbers on the basis of experimental data. The Hatta number describes the correlation between reaction velocity and mass transport and was found to be <0.3 indicating that the process is reaction-controlled. The same conclusions were drawn from the Damköhler number which is the ratio of reaction rate to diffusion rate. Values ≪1 exclude a mass transport-controlled deposition of CaCO3. The temperature dependency was described with the help of an Arrhenius approach and the results were in good agreement with literature data. The kinetics of fouling in a micro heat exchanger with a cross flow arrangement was studied and modelled by Mayer et al.25 They determined the thermal fouling resistance by temperature measurements and the mass-based fouling resistance by measuring the pressure drop. Additionally, they determined the surface coverage of the CaCO3 deposits in the micro channels with a digital microscope. Correlating these results with the determined fouling resistance values showed that the surface coverage rate was a good estimate of the fouling behavior of salt solutions in micro devices. A threshold for the transition from the induction to the crystal growth period was defined on that basis.
Different coatings and their influence on fouling mechanism in laminar flow regimes were studied by Benzinger et al.26 However, the diamond like carbon (DLC) and fluorinated ethylene propylene (FEP) coatings did not lead to any significant changes compared to fouling studies conducted with uncoated stainless steel (316L) devices as reference.
Cleaning in place (CIP) experiments of micro heat exchangers with CaCO3 crystal fouling layers were carried out with HCl solution by Mayer et al.24 Visual observations revealed that cleaning progressed very quickly after the first channels had been freed from deposits. The CIP procedure might have also been enhanced by bypass flows below the strips separating the different microchannels from each other, which were enabled by the clamped design of the micro heat exchanger. Nevertheless, the cleaning experiments were fairly reproducible. Another in situ cleaning method, the application of ultrasound, was investigated by Benzinger et al.27 in an electrically heated micro heat exchanger. After the outlet temperature of the salt solution had dropped by 15 K due to CaCO3 fouling, an ultrasonic pulse of 1 min was applied. In this manner, the starting temperature was achieved. The power level was, however, too low to generate cavitation, so the cleaning effect resulted from acoustic micro streaming near the solid/liquid interface. In the following cycles, the heat flow rate decreased at an ever faster rate after each sonic treatment. Optical observations indicated that this was due to remaining crystals in the micro channels.
Ref. | Particles | d h [μm] | d p [μm] | Re [—] |
---|---|---|---|---|
Niida (1989)35 | Polystyrene latex, iron oxide | 730 | 1–15, 0.3, 0.73 | 32–8200 |
Yiantsios (1998)38 | Glass | 670 | 1.8 | 33–89 |
Yiantsios (1995)36 | Glass | 670 | 2–15 | 4.2–5200 |
Vacassy (2000)50 | CaCO3 | 4000 | <20 | <10 |
Schenk (2001)56 | CaCO3 | 107 | 60 | |
Werner (2002)45 | Different types of reactions and micromixers | |||
Jongen (2003)51 | CaCO3, BaTiO3 | <3 | ||
Yiantsios (2003)37 | Glass and silica | 460–670 | 0.9–1.8 | 33–89 |
Wille (2004)5 | Azo-pigments | 1000 | Turbulent | |
Shestopalov (2004)48 | Colloidal CdS | 50 | <10 | |
Takagi (2004)42 | Titanium | 3000 | ||
Wagner (2005)40 | Gold | 170–260 | 0.005–0.05 | 50–800 |
Kockmann (2005)3 | Aerosol | 461 | 0.010–0.850 | 417 |
Heim (2006)28 | Aerosol | Numerical simulation of experimental results from Kockmann3 | ||
Přibyl (2005)55 | CaCO3 | 500 | Diffusive mixing | |
Sharp (2005)63 | Polystyrene latex | 75–400 | 22–136 | 15–600 |
Gerdts (2006)52 | Protein | ∼200 | <200 | |
Perry (2006)32 | Silica | 106 | 3–10 | 18.4 |
Poe (2006)49 | Indigo | 1600 | ∼100 | |
Nagasawa (2006)47 | Silver halide particles | 100 | <0.1 | 400–10000 |
Heinzel (2007)62 | Polystyrene spheres | 100–285 | 0.7 | |
Sotowa (2007)53 | CaCO3, silver | 500 | <1 | <10 |
Perry (2008)31 | Silica | 225 | Si: 4 | 17 |
Alumina | Al: 1.25 | |||
Perry (2008)33 | Al2O3 | 220, 225 | 0.248–24 | 17–41 |
Kockmann (2008)2 | Barium sulfate | 400 | 0.25 | 300–500 |
Shukla (2009)39 | Glass spheres | 230 | 115–218 | <0.1 |
Marmiroli (2009)43 | CaCO3 | 17 | <150 | |
Georgieva (2010)65 | Latex dispersions | 10–26 | 0.1–0.14 | <1 |
Génot (2010)44 | Organic nanocrystals | 15 | 50–110 | <1 |
Horie (2010)54 | Maleic anhydride | 500–1600 | ∼1000 | |
Sedelmeier (2010)59 | Manganese dioxide | 500 | ||
Hartman (2010)57 | Aryl chloride | 400 | 400 | <5 |
Genovese (2011)30 | PMMA | 100 | 2.3 | |
Noël (2011)58 | Aryl chloride | 400 | 400 | <5 |
Chowdhury (2012)34 | TiO2 | 160 | 0.7–1.2 | <1 |
Grundemann (2012)46 | Ink agglomerates | 600 | 0.1–2 | <1000 |
Zhengying (2012)41 | Sand | 1100–1800 | 100–300 | |
Schoenitz (2014)66 | Lipid | 200 | 0.3 | 30 |
Papers referred to in Table 3 that also contain experimental work are discussed in the remainder of this chapter. Hartman4 worked out three hydrodynamic mechanisms that lead to particulate fouling in micro devices: constrictions, bridging and random detachment of deposits. The following chapter is subdivided accordingly. Since papers describing aerosol-based fouling and blocking issues in microstructured devices are published very rarely, they are discussed in the following paragraph, independently from the above stated three hydrodynamic mechanisms. All other papers deal with particle-laden liquids.
(3) |
(4) |
A Stokes number below 0.05 is recommended to prevent aerosol particle deposition by inertia.3 These experiments were compared with fluid dynamic simulations of the micro-mixer by Heim et al. and showed good agreement.28 Bell and Groll29 also investigated fouling caused by aerosols passing different types of dust through several plate-fin heat exchangers with spacings between the fins of 2 mm, 1.3 mm and 1 mm. In general, smaller spacings resulted in higher particulate fouling.29
The influence of varying shear stresses on particle attachment, transport and removal was studied by Yiantsios and Karabelas.36–38 They performed experiments with glass particles on substrates made of glass and stainless steel. At low shear stress rates, sedimentation-controlled deposition occurred, whereas the lift force gained more influence at increasing shear stress rates. The experimental results were in good agreement with a particle deposition model. In the same way, Shukla and Henthorn39 investigated the detachment velocity of single glass particles. It increased logarithmically with the ratio between the particle diameter and the characteristic microchannel dimension.
Furthermore, they calculated the forces acting on a single spherical particle and suggested improvements to the model. Wagner and Köhler40 analyzed the attachment and detachment of synthesized gold nanoparticles with particle diameters in the range of 5–50 nm. However, the microstructured reactor had only been used for short periods of time: enough to produce less than 10 ml gold nanoparticle dispersion. Within these short periods of time gold films or deposits of elementary gold were found inside after processing. This means the reactor surfaces acted as a nucleation starter at low flow rates. However, at higher flow rates, less fouling was observed due to higher shear stress near the surfaces.40
The second fouling-preventing method – the determination of the critical diameter of the particles – was studied by Zhengying et al.41 Based on three examples, Wiles and Watts18 drew the conclusion that blocking by particles occurs in cases where the particle size is larger than 10% of the smallest dimension in the system.
Fig. 3 Schematic of the hydrodynamic-focusing principle. Fluid B is squeezed by fluid A. In fluid B, precipitated particles will have no contact with the microchannel walls. |
Marmiroli et al.43 reported this technique for the precipitation of calcium carbonate. Particles attached to the walls interfered with particle size measurements using X-ray scattering and even led to channel blockages. The output nozzle had a diameter of 6 μm and the output was 288 μl min−1 in total, resulting in a jet velocity of 13 m s−1. Furthermore, the device was specifically designed to prevent recirculation and flow stagnation in front of the nozzle, which had resulted in unwanted particle formation and deposition inside the mixer in previous designs.43
Takagi et al.42 also successfully adopted the hydrodynamic-focusing concept by using a double-pipe structure to produce titanium nanoparticles. Two immiscible fluids were led through the inner and outer tubes of various diameters. Depending on the flow velocity and properties of the fluids, an annular flow, slug flow or a flow spreading the inner tube fluid was created. The desired stable annular flow was achieved at low relative velocities between the two fluids. In this manner, the microspace between the two fluids used for nanoparticle synthesis was manipulated. SEM and TEM images revealed that uniform titanium particles were produced. Particle size increased with the inner tube diameter. The particles could easily be handled since no confined space was needed for particle synthesis and the outer fluid prevented any particle–wall contacts. The authors also claim that the device was advantageous due to easy maintenance and a low-priced setting.42 Another example of a successful implementation of the hydrodynamic focusing concept was given by Génot et al.44 They employed a 3D focusing device for the anti-solvent crystallization of rubrene.
Werner et al.45 used two different mixer designs to investigate the potential suitability of precipitation reactions, both adopting the hydrodynamic-focusing principle. In an impinging jet mixer two fluid jets collide at a specific angle in the center of a mixing chamber. A gaseous or liquid stream surrounding the collision point hinders any particles formed from impinging on the wall. Stable jets required a certain minimum flow rate, a stable Y-jet being the preferred flow for precipitation reactions. Increasing the flow rate enhanced turbulent flow, and therefore the mixing quality, until a constant value was reached. The second mixer was a separation layer micromixer: inert solvent layers were introduced between the reacting fluids to shift the reaction and accompanying precipitation away from the multichannel feeds to larger mixing channels. This type of mixer required a laminar flow regime. Metallo-organic reactions and processes using auxiliary bases (e.g. amide formation) were considered. Three of the processes were used to evaluate both mixing concepts. The reactions could not be carried out in standard micromixers due to blocking within a few seconds. Although intense precipitation occurred during the experiments, a continuous-flow process was established. The authors stated that the impinging jet mixer offers the most robust processing and best performance, whereas the separation layer mixer required more precise fluid control.45
The impinging jet mixer was also used by Grundemann et al.46 for a continuous ink mixing process. Agglomerates may form if the induced mixing energy is too low. These agglomerates tended to deposit inside other mixing devices and in downstream equipment, eventually leading to plugging. However, the induced mixing energy was high enough to prevent the formation of agglomerates when an impinging jet mixer was used. A stable ink production process was therefore realized and in-spec ink was produced.46
A microreactor for fine particle production that is similar to the separation layer micromixer was developed by Nagasawa and Mae,47 in the form of an annular multi-lamination microreactor. The reaction section was designed such that five annular layers of different fluids were formed, which were injected into the mixing and reaction zones as annular lamellar segments. Mixing was promoted by contracting channels that reduced the diffusion distance. The outermost and innermost lamellae serve as protection layers of the three streams in the middle and may also help to transport the fluids through the pipe in case of highly viscous reactants. If inert fluids are used, they will then prevent any wall contacts by the synthesized particles. A stable continuous crystallization of silver halide was demonstrated.47
Another way to avoid particle–wall contacts is to encapsulate precipitated particles by droplets, which are immiscible in the surrounding fluid. Shestopalov et al.48 demonstrated this microfluidic method for the synthesis of colloidal cadmium selenide nanoparticles. Using microfluidic devices made of PDMS with channels of 50 μm height and 50 μm width, two aqueous reagents were separated by an inert fluid. The latter was used to prevent mixing between the two reagents until they had flown into a water-immiscible fluorinated oil phase to form droplets. The droplets were then transported by the oil phase through a number of winding channels allowing for mixing by chaotic advection and consequently for the reaction inside the droplets. A second reaction step was initiated by injecting a third reagent directly into the droplets. For mixing and reaction, another winding passage followed the merging junction. Only a negligible build-up of particles was found at the merging junction, and no particles adhered to the channel walls during 30 min.
Poe et al.49 also investigated disperse-phase droplets as individual reactors and transport means to inhibit fouling during indigo synthesis. Their device was composed of syringe pumps, syringes, needles and laboratory tubing. A fluid inlet was created by inserting a needle with an inner diameter of 0.15 mm (outlet of the syringe) into the tubing. An inert carrier fluid was used as the continuous phase. Several reacting streams were inserted as droplets downstream. Mixing was either initiated by collision of two different reagent droplets or by diffusion from the carrier into the disperse phase. Mineral oil, hexane and toluene were used as inert and available carrier fluids. Using a mineral oil carrier phase, fouling inside the tubing was prevented.
Further work regarding droplet or segmented flow-based micro reactor designs that avoid particle–wall interactions to reduce fouling is reported widely.50–54
Wille et al.5 also stated the importance of proper design for in- and outlet geometries to avoid the settling of particles. In their work azo-pigments were synthesized in a selection of different micromixers. Their mixing characteristics were first evaluated with the Villermaux–Dushman reaction. During synthesis with a caterpillar mixer the device was completely blocked, mainly due to the rectangular in- and outlet geometry of the device, as mentioned by the authors. As measures against blockage for processes involving particles or suspensions, they underline the importance of straight in- and outlet geometries so that particles cannot sediment.5
Researchers have also adapted process conditions to achieve low fouling tendencies: Hartman et al. performed a Pd-catalyzed C–N bond formation reaction in a microfluidic device with and without ultrasound. Without ultrasound, the formed particle sizes were on the same order as the channel dimensions (∼400 μm), resulting in blocking. With ultrasound, the particle sizes decreased significantly, resulting in decreased fouling tendencies.57,58 Similarly, Horie et al.54 used ultrasound to inhibit the adhesion and sedimentation of precipitated particles in a micro reactor.
Sedelmeier et al.59 stated that blocking issues could be solved for microstructured devices with a proper device design. They have validated that approach with several specifically designed reactors. However, they conclude that these solutions require specifically designed equipment and are of no use for standard commercial flow equipment. In their experiments, they used a T-mixer followed by a tube reactor with an inner diameter of 0.5 mm. However, stoichiometric quantities of manganese dioxide were formed during synthesis, which deposited in the reactor. This meant that the process had to be regularly interrupted to enable cleaning of the T-piece connector. When the T-mixer along with a short length of the subsequent reactor tubing were placed inside an ultrasound bath, the aggregated manganese dioxide was effectively dispersed. As a result the mixture could be pumped as a suspension through the coil reactor with no adhesion or fouling, thus achieving a continuous flow process.59
Fig. 4 Mechanism of bridging [modified63]. |
Bridging occurs when particles are growing in size or at constrictions, i.e., at reduced flow path cross-sections. Wyss et al.64 stated that clogging by bridging is based on the particle volume fraction. If the local particle concentration is large enough, bridging can occur. Also for systems with particle-to-particle or particle-to-wall repulsion, bridging can occur. In this case, a sufficiently high velocity is applied, which overcomes the interparticular repulsion forces, resulting in the formation of stable bridges.4 The formation of bridges is expected for ratios of the flow characteristic path length to particle size of less than 3–4. Thus in practice, it is recommended that this ratio should be greater than 10.4 Sharp and Adrian63 investigated blocking of 75 μm to 400 μm glass capillaries by polystyrene latex particles, where the ratio was 3. They stated that blockage by bridging is a blocking mechanism (see Fig. 4) that has to be taken into consideration, especially for fouling in microchannels.63 Another hint for bridging in micro dimensions was given by Georgieva et al.65 They investigated the clogging of a ring-slit with highly concentrated latex dispersions (about 50 wt%). Against expectations, they showed that clogging of the ring-slit is independent of surface properties (hydrophilic vs. hydrophobic). This lead to the assumption that clogging of the ring-slit is not induced by particle deposition but by hetero-coagulation in the flow field at the slit entrance with impurities in the dispersions, supporting bridging due to higher particle/agglomerate diameters.65 They showed that the blocking phenomenon depends on the flow rate. Small volumetric flow rates, resulting in small shear stresses, decreased the blocking tendency. This effect is also in accordance with observations by Hartman et al.57 where decreased bridging tendency was attributed to lower shear stresses, as the particle–particle repulsive forces were dominant.
Ref. | Fouling system | Surface material | d h [μm] | Re [—] |
---|---|---|---|---|
Lipscomb (2002)72 | Proteins | Glass | 250 | <10 |
Bi (2006)71 | Serum/plasma | PEG coated PMMA | 50 × 120 × 3500 | |
Helton (2008)74 | Human saliva | PMMA | 62 × 3.6 × 60 | 0.4–4 |
Zhang (2008)69 | Living cells | Coated glass substrates | 60 × 320 × 2320 | <1 |
Um (2008)75 | Living cells, proteins | PDMS | 90 × 50 | <1 |
Ngene (2010)68 | Biofilm solution | PMMA | Spacers: height of 700 | 83 |
Patel (2010)73 | Proteins | Coated ITO glass | ||
Schmolke (2010)70 | Yeast cells | Coated PDMS | 120 × 4000 × 64000 |
Ngene et al.68 investigated the formation of biofilms upstream and downstream of membranes induced by freestanding structures, which act as spacers (∼700 μm height) between different membranes and other surfaces. They investigated four different structure types experimentally and by CFD simulations. No relation between local wall shear stress and biofilm formation was found. They concluded that more comprehensive research is needed to correlate hydrodynamic conditions, micro-topology and biomass surface properties. To investigate the attachment and detachment of living cells in microfluidic-based lab-on-a-chip systems, Zhang et al.69 introduced a new method. They investigated the influence of different surface modifications on the shear forces induced by increasing volumetric flow rates needed to detach living cells in microchannels. They also fitted the experimental data with a theoretical model, taking into account shear stress, surface adhesion bonds and hydrodynamic viscous stress. With this approach, different surfaces were investigated for their attachment/detachment behavior to a wide range of living cells in an easy and controlled fashion.
Schmolke et al.70 investigated the detachment of living cells in microreactors. They used varying compositions of PDMS-based polyelectrolyte multilayers as surface coatings to create low-fouling surfaces in micro-bioreactors. They found that the adhesion strength of S. cerevisiae on different multilayer modifications was significantly reduced when compared to uncoated PDMS.
Bi et al.71 described a modification of PMMA microchannels for bioanalysis. They stated that PMMA microchips are widely used to fabricate microfluidic devices because of their low cost, flexibility and ease of use in mass production, but have so far not been employed for biological applications due to hydrophobicity, poor biocompatibility and fouling (non-specific protein adsorption). They investigated a one-step procedure to create a hydrophilic surface on the hydrophobic PMMA substrate, resulting in low non-specific adsorption and thus low fouling.71
Lipscomb et al.72 identified that the control of surface properties of glass-microchannels is a major parameter for preventing fouling of proteins on glass substrates. Patel et al. designed superhydrophilic surfaces for antifogging and antifouling investigations into microfluidic devices based on ITO-glass (indium tin oxide coated glass) and polyester.73 The prepared surfaces showed a near-zero water contact angle (compared to 80° and 95° for the untreated surfaces). The adhesion of fluorescent proteins was investigated by fluorescence microscopy indicating a strong anti-fouling effect of the superhydrophilic surface for these proteins. Thus these surface modifications indicated potential for microfluidic devices. Helton et al. stressed the importance of pre-treating products processed in microchannels to prevent fouling issues.74 They investigated chip-based micro total analysis systems (μTAS) for biomedical diagnostics of patient samples.74 Biological contaminations due to mucins and proteins in the saliva led to fouling on the biosensor. Adequate pretreatment of saliva, filtering and H-filter extraction led to >90% less mucins and proteins and thus less fouling on the biosensor.74 Um et al. described a method to avoid interactions between microchannel walls and biomaterials.75 They encapsulated the living cells and proteins in hydrogel beads in a droplet-based micro reactor to minimize or avoid interactions between biomaterial and reactor walls.
So far, no reports covering corrosion fouling in microstructured devices have been published, whereas papers covering the preliminary phenomena erosion77–82 and/or corrosion83–91 of microchannels exist. To give an overview of the investigations of these preliminary phenomena of corrosion fouling, Table 5 lists experimental reports of erosion and corrosion in microstructured devices stating the fluid or substance used, the surface material of the microchannel walls and the maximum duration of the experiments. All papers investigated erosion or corrosion phenomena based on devices that were taken out of service after several 1000 hours of operation. Thus, no time-dependent local erosion and corrosion investigations were possible and the published investigations are qualitative rather than quantitative.
Ref. | d h [μm] | Fluid/medium | Surface material | t [h] |
---|---|---|---|---|
Bowers (1994)78 | 510 | R-113 | Metallic surfaces | |
Ferstl (2004)88 | Concentrated sulphuric acid, fuming nitric acid | Several metals, PTFE, PFA, silicon, Si3N4, SiO2 | ||
Treusch (2005)80 | 300 | Filtered tap water | Copper | 1000–10000 |
Kockmann (2005)3 | Water | Alumina foil | 50 | |
Wright (2006)90 | Decomposition environment of sulfuric acid (>900 °C) | Different sintered materials | 100, 200, 500, 1000 | |
Daymo (2007)82 | Combustion conditions | Alloy 617 (coated) | 4000 | |
Lee (2007)77 | 821 × 215 × 44800 | Nanofluid containing Al2O3 | Copper for microgrooves, polycarbonate | 30/94 |
Feeler (2008)81 | Water | Copper, ceramic | 550–2500 | |
Karni (2008)83 | Filtered tap water, deionized water | Copper | 500–1000 | |
Balsley (2009)84 | Deionized water | Copper, surfaces were Au plated | 1000–5000 | |
Jackel (2011)85 | 150–300 | Filtered, deionized, deoxygenated water; 10% acetic acid | Copper with Au coating | |
Makarshin (2011)91 | 50 | Catalytic partial oxidation of methane | FeCrAl | |
Eichhorn and Gietzelt (2012)76 | Hot sulfuric acid (95–97% at 100 °C/50% at 125 °C) | Nickel-based alloy and glassy carbon (Sigradur® G) | 336/1008 | |
Bonner (2012)79 | Deionized water, salt water solution | Copper, gold-plated copper, aluminia/Au plated | ||
Gietzelt (2013)89 | 300 | Hot sulfuric acid (95–97% at 100 °C) | Hastelloy | 1000 |
As the prevention or mitigation of corrosion fouling and preliminary phenomena erosion and corrosion is a matter of the correct choice of material, several papers deal with selecting suitable materials for the process conditions.76,87–89
Clogging by gas bubbles particularly occurs while filling the microchannels at the start of an experiment.3,93 Before starting an experiment, the microchannels usually contain air, which can lead to clogging of the micro device or single microchannels through air bubble entrapment. As the channels are filled with reactants during the process, this effect is commonly not induced in that case. During processing, another effect may however hinder the production: gas bubble clogging due to rapid coalescence and therefore growing gas bubbles. If the design of a device is based on internal numbering-up, e.g. multiple parallel microchannels within one micro device, blocking of single microchannels alters the internal geometry of the device. This may lead to flow maldistribution which may result in inhomogeneous product properties.94 Furthermore, the flow resistance across the device/channel increases.95 Also optical detection methods can be affected due to light reflections from entrapped air bubbles.93 This chapter is divided into two parts: (1) gas bubble clogging during filling/priming of microchannels, and (2) gas bubble clogging due to rapidly growing gas bubbles during processing. Table 6 lists experimental reports of gas bubble clogging in microstructured devices stating the characteristic dimensions and Reynolds numbers of the experiments.
Ref. | d h [μm] | Re [—] |
---|---|---|
Gravesen (1993)105 | ||
Zengerle (1995)102 | ||
Kim (1997)99 | 0.7–1.4 | Capillary filling |
Man (1998)97 | 33 | |
Sesterhenn (1999)101 | Capillary filling | |
Tseng (2002)96 | Microchannels: 83 reservoirs: 200 | 0.002 (capillary filling) |
Kim (2002)98 | 1000 to 100 | |
Kohnle (2002)92 | 583 + 150 | 8–420 |
Goldschmidtböing (2003)93 | 230 | |
Jensen (2004)100 | Numerical simulation | |
Steinert (2004)103 | 29 different geometries | |
Kockmann (2005)3 | ||
Meng (2007)95 | ||
Litterst (2008)104 | 460 | |
Maikowske (2010)94 | 133 |
Edges are preferentially wetted prior to plane microchannel walls, which results in a splitting of the fluid in micro cavities at cross-sectional extensions and gas inclusions as illustrated in Fig. 5.3,93
Fig. 5 Mechanism of gas inclusion via an unstable meniscus in micro cavities or cross-section extensions [adapted3]. |
Goldschmidtböing et al.93 identified this process of air entrapment by an unstable meniscus as the predominant mechanism for the formation of air bubbles in microstructured devices. Capillary and viscous forces dominate while filling the microchannels. Based on numerical simulations, they provide design rules which are independent from experimental fits and can hence be applied to identify “filling-friendly” microfluidic structures.93
Tseng et al.96 investigated the surface tension-driven filling (i.e., capillary filling) of microchannels with integrated reservoirs of specific shapes. The reservoirs had rectangular or 45° shapes. Both the microchannel as well as reservoir surfaces were modified. This led to different hydrophilic/hydrophobic properties and varying contact angles between the process fluid and the surface. Reynolds numbers were approximately 0.002. Complete filling of the reservoirs failed for all tested surface modifications, which accorded with the results of the numerical simulations. Integrated reservoirs or any kind of microchannel enlargement led to different pressure barriers for the fluid flow.
Man et al.97 calculated these pressure barriers for differently shaped microchannel enlargements. If a fluid passes these enlargement regions, the capillary forces have to exceed the pressure barriers. External pressure can be used to overcome the pressure barrier, which can be provided by heating or electrolytic generation of O2 bubbles in the liquid phase.97
Kim et al.98 investigated the surface tension during filling under varying inlet pressure conditions with an array of 10 parallel microchannels of different widths ranging from 0.1 mm to 1 mm. In the narrowest microchannels, air blockages occurred, which they attributed to the negative effect of surface tension. At high inlet pressures, air got entrapped between the microchannel outlets due to dominating inertia forces. This effect was not detected at low inlet pressures because of the dominating viscous forces in this case.99 The experimental results were verified by numerical simulations.
Jensen et al.100 investigated clogging mechanisms by gas bubbles that depended on the pressure conditions within microchannels to derive design rules for their construction at low clogging pressures. The clogging pressure is defined as the pressure at which a clogging gas bubble is pushed out of the microchannel.100 The smaller the clogging pressure, the easier it is to wash-off clogging gas bubbles. Their numerical simulations were based on geometry parameters like the angle of the constriction, the contact angle and the initial bubble length.100 Kim and Whitesides99 investigated the influence of varying surface properties on the macroscopic front of the filling liquid. They filled rectangular capillaries with liquid prepolymers, which were then solidified by photopolymerization within seconds. This method revealed how filling structures of the liquid by microscopic methods depend on the applied self-assembled monolayers, which caused varying surface properties. In order to predict the clogging behavior of capillaries, Sesterhenn et al.101 studied complex capillary networks by simulating their (self-)priming and emptying depending on inertia, friction, gravitation and capillarity.
In most cases, the clogging gas bubbles consist of air whose solubility is low in many priming liquids, specifically in water. Taking this into account, Zengerle et al.102 proposed a new method for gas bubble free-priming of microchannels: before priming microchannels, they replaced contained air (O2–N2 mixtures) with CO2 whose solubility is 30-fold-higher in water compared to air. Hence, gas bubbles are not washed off due to high pressures, and instead they are dissolved in the priming liquid. This method is also useful for priming dead-end microchannels. However, carbon dioxide priming before experiments requires an extra purging step making experiments less user-friendly and more complex.102 Steinert et al.103 therefore presented special designs of dead-end microchannels which also allowed for bubble-free capillary filling.
Gas bubble clogging is of special interest at evaporation processes in microchannels, especially when the flow velocity is too low to wash off all generated gas bubbles. Maikowske et al.94 investigated vapor clogging and slugging phenomena which occur during water evaporation in microchannel arrays. They observed two different types of vapor clogging: vapor plugging at channel inlets and inside the microchannels. Different vapor clogging phenomena led to flow maldistributions and hence to inhomogeneous vapor quality at the vapor outlet of microchannel arrays.94
Meng et al.95 stated that methods like “bypassing”, “trapping” and “special shapes” of microchannels can tolerate limited amounts of gas within the microchannels, but do not solve the bubble clogging problem itself. If gas is generated constantly during processing, efficient gas removal out of the microchannels is needed. Therefore, Meng et al.95 employed microscopic hydrophobic capillaries encased by hydrophobic nanoporous membranes. Gas bubbles are removed through these hydrophobic capillaries while the liquid is retained by the hydrophobic membranes from flowing out.95
Taking air bubble clogging into account, a modification of the fouling definition especially for microchannels seems meaningful. Reformulating this definition in a broader sense to the “unwanted accumulation of material affecting heat, mass and/or momentum transport” instead of “unwanted deposition on surfaces” would also include air bubble clogging as a fouling phenomenon in microchannels.
At these typical laminar flow regimes in micro devices paired with low wall shear stress affecting the fouling layers, fouling build-up increases whereas the detachment of matter decreases. Therefore, microchannels are very prone to fouling and complete blockages, resulting in maldistribution of the fluid flow in parallel channels. Blocked channels also cause altered cleaning mechanisms compared to non-blocked channels, as Schoenitz et al.106 point out: in “non-blocked microchannels, cleaning is induced by wall shear stresses. In contrast, blocked microchannels lead to dead zones up-stream of the blocked areas, resulting in pressure forces instead of shear stresses. Thus especially for these blocked channels, chemical cleaning becomes more important”.106
In operating microstructured devices a capturing effect has also been observed.66,107 The effect is due to porous fouling layers with internal pores of various sizes acting as obstacles for particles or agglomerates, which have been detached upstream of the pore system. Blockages may then occur as a consequence of this capturing effect and may consequently be attributed as secondary fouling. Primary fouling, on the other hand, is based on particle–wall or particle–particle adhesive forces. In macrostructured equipment, secondary fouling is very rare since the characteristic dimensions are much larger. If such pronounced fouling layers were to occur in macrostructured equipment, heat transfer and pressure drop would suffer to such an extent that a cleaning cycle would be started before secondary fouling occurred.
These short time scales for fouling events may also give rise to the observed absence of aging phenomena in microsystems. If encountered, fouling in microstructured devices requires immediate measures thus preventing any deposit from a long-term aging process.
Negative values for the thermal fouling resistance, i.e., enhanced heat transfer, are reported at turbulent flow regimes in macro dimensions. This is attributed to roughness and constriction effects due to the fouling layers.20 This effect was also observed by Schoenitz et al.107 for micro devices, although at laminar flow regimes. In their investigations the maximum absolute values of thermal fouling resistance (thermal effect) and pressure drop (fluid dynamic effect of fouling) are much higher in micro dimensions, whereas the normalized increase of these fouling indicators is in the same order of magnitude compared to macro devices.107 The “Degree of Fouling Increase” (DFI) may be employed for the comparison of fouling processes in micro and macro devices,107 see eqn (5):
(5) |
Traditionally, macro scale fouling phenomena can be classified based on Epstein's 5 × 5 matrix.14 For fouling in micro dimensions, a sixth fouling category may be added to that matrix: clogging by gas bubbles. Although this type of clogging does not follow the macroscopic definition of fouling (“unwanted deposition on surfaces”), it results in comparable effects with respect to heat, mass and/or momentum transport to the affected devices. Thus, gas bubble clogging can be considered as a micro-specific fouling category, resulting in a 5 × 6 micro fouling matrix, see Fig. 6.
Following Wilson's approach to quantifying the research progress in macro scale fouling,15 experimental-based papers (70 of all reviewed papers) dealing with fouling in microstructured devices were assigned to the respective fouling category as shown in Fig. 6.
In the first line, the number of papers assigned to the respective fouling category is indicated. In the lines below, the percentage of papers of a certain fouling category is stated in which this particular fouling event was addressed. Multiple events were accounted for. It is obvious that the majority of papers within the 5 × 6 matrix were dealing with “particulate fouling”. This is mainly due to the fact that microstructured devices offer great advantages specifically for reactions involving particle precipitation: based on intensified mixing on the micro-scale, the resulting particle size is decreased as well as the particle size distribution narrowed in many applications. Such reactions were among the very first examples studied in microstructured devices and are still being investigated. As corrosion fouling is a matter of correct choice of material and oftentimes of long-term experiments, only papers dealing with the preliminary effects erosion and corrosion were found. Similar to this fouling category, the number of papers studying “clogging by gas bubbles” also was small. However, many papers dealt with the crystallization of solids, which were allocated to “particulate fouling”. “Crystallization fouling” itself requires the formation of nuclei and their subsequent growth on the surface. Fouling due to biological systems in microstructured devices was studied only rarely, as biotechnological processes – aside from lab-on-a-chip or biomedical applications – just occasionally employ micro devices. The investigations mainly aimed at preventing fouling by observing and tackling the “initiation” and “attachment” phases are shown in Fig. 6. “Aging” of depositions in microstructured devices was not addressed in any of the reviewed papers. This might be due to the fact that fouling in these dimensions is not tolerable for most applications, therefore processes are directly shut down when fouling occurs.
Revealing the fundamentals of fouling in microchannels, however, requires experimental studies of all sequential events and all influencing factors.
This journal is © The Royal Society of Chemistry 2015 |