aUniversità degli Studi di Milano, Dipartimento di Chimica and C.I.Ma.I.NA, via Golgi 19, 20133 Milano, Italy. E-mail: serena.arnaboldi@unimi.it; patrizia.mussini@unimi.it; francesco.sannicolo@unimi.it; Tel: +39 0250314211
bDipartimento di Scienza e Alta Tecnologia, Università degli Studi dell'Insubria, via Valleggio 11, 22100 Como, Italy
cDipartimento del Farmaco, Istituto Superiore di Sanità, Viale Regina Elena 299, 00161 Roma, Italy
dInstitute of Physical Chemistry, Polish Academy of Sciences (IPC PAS), Kasprzaka 44/52, 01-224 Warsaw, Poland
eFaculty of Mathematics and Natural Sciences, School of Sciences, Cardinal Stefan Wyszynski University in Warsaw, Woycickiego 1/3, 01-938 Warsaw, Poland
First published on 13th January 2015
2,2′-Bis[2-(5,2′-bithienyl)]-3,3′-bithianaphthene oligomers are a model case of electroactive films endowed with “inherent chirality”, originating from a stereogenic element coinciding with the whole electroactive backbone, thus resulting in impressive manifestations. This study highlights their applicative potentialities as low-cost and easy-to-prepare artificial enantiopure electrode surfaces, which display an unprecedented ability to pronouncedly separate voltammetry peaks of enantiomers of quite different chiral probes of applicative interest, concurrently with linear dynamic ranges for peak currents, affording enantiomer excess determination. Thus inherently chiral enantiopure electrodes can indeed be regarded as a key to chiral voltammetry.
Enantiomeric molecules, being mirror-image structures, have identical physico-chemical scalar properties (properties unchanged by reflection, like m.p., nD, λmax, etc.), but opposite pseudo-scalar ones (properties inverted by reflection, like αD, CD ellipticity, enantiodiscrimination capacity, etc.). When interacting with a racemic probe, chiral molecules are able to recognize the enantiomers through diastereomeric interactions. Classic examples are the selective dispersion and absorption of the two opposite circularly polarized components of plane-polarized light effected by chiral materials, and the chiral stationary phases in HPLC, which control the elution times of two enantiomers. Similarly, chiral electrodes are required for enantioselective electroanalysis.
The only efficient examples of chiral electroanalytical enantiodiscrimination already in use are provided by biosensors, composite systems based on chiral biological materials, chiefly enzymes, as recognition layers, coupled with prevailing amperometric or potentiometric signal transduction. In this context, the development of chiral electrode surfaces and sensors based on artificial enzymes or prepared using synthetic materials is very attractive. In the last few years, chiral platinum surfaces,1–5 SAM-modified electrodes,6,7 surface-modified nanoporous opal film electrodes,8 metals doped with chiral organic molecules,9 films imprinted with enantiopure templates,10–13 or including a chiral crown ether derivative14, a sensitivity-enhanced field-effect chiral sensor hinging on a thiophene-based monomer,15 and mesoporous chiral metal surfaces16 were described.
However, even the most successful attempts at chiral discrimination almost invariably resulted in just the detection of a difference in current intensity between the signals of the two antipodes of a model probe, without differentiation of their redox potentials. Moreover, the chiral enantioselective layer was in many instances specifically tailored for a given probe molecule. Finally, many procedures of surface modification appeared to be very sophisticated and/or the active films very fragile. In this context, most desirable is the development of a low-cost and easy-to-prepare artificial chiral electrode material, stable and capable of discrimination of a wide variety of antipode pairs. Above all, however, discrimination should result in a well pronounced differentiation in the antipode redox potentials, with the corresponding currents exhibiting a linear dynamic range, so that the two antipodes could be recognized and the enantiomeric excess estimated.
Chiral conducting polymers and oligomers represent an attractive pool where a solution to the above issues could be looked for. However, the approaches exploited so far,17 namely, the attachment of chiral pendants to common achiral monomers, or the adoption of chiral templating conditions, have led to poor or unstable chiral manifestations, possibly on account of the “external” nature of the chirality source.
Recently, we devised an innovative approach to chiral conducting thiophene oligomers, based on the concept of “inherent chirality”.18–21 In these oligomers, the stereogenic element is a tailored torsion intrinsic to the whole electroactive backbone. This torsion arises from insertion of atropisomeric biheteroaromatic scaffolds, rather than stereocenters localized in attached pendants. Therefore, in these oligomers, the stereogenic element responsible for chirality is also responsible for electroactivity, since it constitutes the conjugated backbone. Moreover, chemical or electrochemical oligomerization of the 2,2′-bis[2-(5,2′-bithienyl)]3,3′-bithianaphthene (BT2-T4) parent monomer mostly yields cyclic oligomers (BT2-T4)n, predominantly dimers and trimers. They constitute rings of fully conjugated thiophene units, idealizing conducting polymers without ends (Scheme 1).
This outstanding feature combination yields exceptional chirality manifestations: among others, circularly polarized luminescence, and, above all, the capability, as an electrode material, to discriminate the two enantiomers of a commercial ferrocene-based chiral probe in terms of redox potential. That is, two neatly separated reversible voltammetric peaks were reproducibly recorded.18,19 However, several issues still remain to be addressed, in particular those involving the assessment of this material’s aptitude to perform as a chiral electrode material. This assessment includes verification of the enantiorecognition ability of the same material towards different chiral redox probes, possibly of pharmaceutical interest. Moreover, it involves verification of the possibility to work in solvents other than the ionic liquid (IL) applied in our initial tests, thus opening up a large field of experiments governed by the solubility of the analytes. Then, analytical parameters, including detectability, sensitivity, and the existence of a linear dynamic concentration range, should be assessed in order to meet the requirements for the determination of chiral analytes, including quantification of their enantiomeric excess.
Accordingly, we herein provide preliminary, but precisely affirmative, answers to each of the above issues. Thus, we show that this new concept should be regarded as an extraordinarily valuable asset for chiral electroanalysis.
The major issue still to be addressed was whether the enantioselectivity of the same chiral films would be comparable towards other chiral probes of different bulkiness and, desirably, of practical importance. To this aim, we herein tested the films using two different chiral probes of pharmaceutical interest, namely 3,4-dihydroxy-phenylalanine (DOPA), a precursor of catecholamine neurotransmitters, and ofloxacin, a very popular antibiotic. Since the IL medium was appropriate for neither one of them, we turned to conventional solvents. Moreover, we used conventional glassy carbon (GC) electrodes because acetonitrile (MeCN) is not compatible with the insulating paints of commercial SPEs. These conditions afforded further validation of the “inherent chirality” approach to electroanalytical enantioselectivity.
Thus, the enantioselectivity tests were performed for 4.0 mM solutions of L-DOPA and D-DOPA in acidic aqueous solution (50 mM HCl), working on (S)- and (R)-(BT2-T4)n films, deposited by potentiodynamic electrooxidation on commercial GC electrodes from 0.5 mM solutions of the starting monomers in MeCN + 0.1 M tetrabutylammonium hexafluororphosphate (TBA)PF6 (Fig. 1).
Enantioselectivity tests were also performed on the ofloxacin enantiomers, i.e., for the 3.5 mM dextro (R)-enantiomer and for the 3.5 to 8 mM more available levo (S)-enantiomer. In this case, the same MeCN + 0.1 M (TBA)PF6 electrolyte solution was used for both the deposition of the chiral (BT2-T4)n oligomer films on the GC supports by potentiodynamic electrooxidation and the subsequent enantiodiscrimination tests. Under these experimental conditions, the ofloxacin first anodic peak was superimposed on the onset of the (BT2-T4)n film oxidation, implying the need to work at high probe concentrations or to apply background subtraction to enhance the signal-to-background ratio. However, a neat difference of about 80 mV was observed between the oxidation peak of a given enantiomer (in our case levo-ofloxacin, available at higher concentrations) on the specular (S) and (R) surfaces (Fig. 2a and b, green and red thick lines). Symmetrically, the same neat potential difference was observed for the two levo- and dextro-enantiomers on the same (R) enantiomeric surface (Fig. 2a and b, thick and thin red lines) on which the dextro- enantiomer is the first sensed, the results clearly visible even at a concentration of 3.5 mM. The separation of the 3.5 mM levo- and dextro-enantiomers on the (S) surface can be observed too, by CV with background subtraction (Fig. 2c).
Finally, some preliminary quantitative analysis tests were performed in search of a linear dynamic concentration range for the chiral probes on the enantiopure film coated electrodes and for exploiting these tests in estimation of the enantiomeric excess when analysing non-equimolar mixtures of enantiomers.
Concerning the first issue, CV patterns were recorded for levo-ofloxacin in MeCN + 0.1 M (TBA)PF6 on the (S)-(BT2-T4)n film coated GC electrode. Despite the levo-ofloxacin first anodic peak being located at the onset of the (S)-(BT2-T4)n film oxidation, the CV anodic peak current was proportional to the levo-ofloxacin concentration in the range 1.0 mM to 10 mM (Fig. 3), yielding a calibration plot which obeyed the linear regression equation of Ianodic/(A) = (1.7 ± 0.1) × 10−2clevo-ofloxacin/(mol dm−3) + (9 ± 9) × 10−6 with the correlation coefficient R2 = 0.996. The sensitivity and detectability were 0.017 ± 0.001 A M−1 and (6.2 ± 0.2) × 10−4 M, respectively, at a signal-to-noise ratio of 3. Thus, the studied chiral film coated electrodes are suitable for quantitative enantioselective analysis.
The possibility of enantiomeric excess evaluation has been achieved, for the first time in electroanalysis, with (S)- and (R)-N,N-dimethyl-1-ferrocenylethylamine probes on oligo-(S)-(BT2-T4)n films, electrodeposited on Au-SPEs in (BMIM)PF6 (Fig. 4). Two symmetrical series of (BMIM)PF6 solutions with increasing S/R or R/S ferrocenyl probe ratios were analysed by DPV, depositing ∼0.025 cm3 drops on the functionalized Au-SPEs. Each measurement sequence was performed with the use of the same film coated Au-SPE by regenerating the surface between subsequent measurements by a few CV cycles in monomer free IL. For both series, ratios of the DPV peak area for the enantiomers correlated well with the enantiomer concentration ratios, as confirmed by a nearly unit slope of the plot in Fig. 4c.
Electrodepositions of the conducting chiral (R)- and (S)-(BT2-T4)n oligomer sensing films were performed on the GC disk electrode with 0.5 mM enantiopure (R)- or (S)-BT2-T4 monomer solutions in acetonitrile with 0.1 M tetrabutylammonium hexafluorophosphate as the supporting electrolyte (Fluka, ≥98%). 36 consecutive oxidative potential cycles at 0.2 V s−1 around the first oxidation peaks of BT2-T4 were performed, followed by repeated potential cycling in a monomer-free solution, until the CV curves became stable.
Enantiodiscrimination tests with (R)-ofloxacin (Carbosynth) and (S)-ofloxacin (Sigma-Aldrich, ≥ 98.0%), and L- and D-DOPA ((S)- and (R)-3,4-dihydroxy-phenylalanine respectively, Sigma-Aldrich, ≥98%) were carried out with 1–10 mM ofloxacin solution in acetonitrile with (TBA)PF6 0.1 M, and with 4 mM DOPA aqueous solution with 0.05 M hydrochloric acid (Sigma-Aldrich, ≥37%, for trace analysis) as the supporting electrolyte.
For the preliminary enantiomeric excess experiments on screen printed electrodes, (BMIM)PF6 IL (Sigma-Aldrich, ≥98.5%), a medium granting very high reproducibility and regularity of oligomer deposition, was employed. Enantiopure conducting oligomer films (S)- and (R)-(BT2-T4)n were electrodeposited from a drop (0.02–0.03 cm3) of the respective 12 mM (S)- and (R)-BT2-T4 monomer solutions, dispensed on screen-printed gold working electrodes (Au-SPEs, Metrohm, 61208210) by 36 consecutive oxidative CV cycles at a 0.05 V s−1 scan rate, followed by several potential cycles in a monomer-free blank medium. The voltammetric characteristics of the (R)- and (S)-N,N-dimethyl-1-ferrocenylethylamine probes (Sigma-Aldrich, ≥ 97%) were then recorded, using the probe dissolved again in a drop of (BMIM)PF6. Solutions with (R)-:(S)-ferrocenyl probe enantiomeric ratios of (i) 1:1; (ii) 1:1.5 and (iii) 1:2, and the specular ones, were employed. The subsequent DPV recordings at increasing (S)/(R) or (R)/(S) ratios were performed on the same electrodeposited film, regenerating it in probe-free conditions between subsequent readings by (a) washing off the probe solution drop with MeCN, then (b) carrying out a few redox cycles in probe-free ionic liquid, then (c) washing off the ionic liquid again with MeCN. In such conditions the film can undergo some modifications that can influence its response to the probe concentration in absolute terms but not in relative ones, as demonstrated by the good correlation in Fig. 4c.
Although each of the above issues will be the object of specific, more detailed studies in the near future, the present preliminary results confirm that the new inherently chiral enantiopure electrodes can indeed be regarded as a very promising key to chiral voltammetry.
This journal is © The Royal Society of Chemistry 2015 |