Minakshmi Paramanikab,
Dhaval R. Rautab,
Arijit Senguptaab,
Sunil K. Ghoshab and
Prasanta K. Mohapatra*a
aBioorganic Division, Bhabha Atomic Research Centre, Trombay, Mumbai-400085, India. E-mail: mpatra@barc.gov.in; Fax: +91-22-25505151; Tel: +91-22-25594576
bRadiochemistry Division, Bhabha Atomic Research Centre, Trombay, Mumbai-400085, India
First published on 11th February 2016
A trialkylphosphine oxide functionalized task specific ionic liquid (PO-TSIL) with a NTf2− counter anion was synthesized and evaluated for the extraction of actinide ions such as UO22+ and Pu4+ from acidic feed solutions using room temperature ionic liquids (RTIL) such as [BMIM][NTf2] and [OMIM][NTf2] as the diluents. The extraction data were compared with those obtained with tri-n-octylphosphine oxide (TOPO) in the same set of RTILs. The extracted species following a cation-exchange mechanism were analyzed by the conventional slope analysis method. The nature of the bonding in the extracted complexes was investigated by various spectroscopic techniques such as luminescence and UV-visible spectroscopy. Studies on the stripping and radiation stability were also carried out for possible nuclear fuel cycle applications.
TOPO (tri-n-octylphosphine oxide) is known to be a more basic extractant as compared to TBP leading to higher extraction of the metal ions at a given feed acid concentration. Solutions of TOPO in RTILs such as [BMIM]NTf2 (1-butyl-3-methylimidazolium bis(trifluoromethane)sulfonamide) or [OMIM]NTf2 (1-octyl-3-methylimidazolium bis(trifluoromethane)sulfonamide) (Fig. 1a) have been employed for the extraction of UO22+ and Pu4+ from HNO3 medium.12 To our knowledge, there is no report on the extraction of actinide ions including UO22+ and Pu4+ from acidic feeds using trialkylphosphine oxide functionalized TSIL (termed hereafter as PO-TSIL, Fig. 1b).
It was, therefore, of interest to investigate the extraction behaviour of UO22+ and Pu4+ from HNO3 medium using PO-TSIL and the results are compared with those obtained with solutions of TOPO in the ionic liquids, [BMIM]NTf2 and [OMIM]NTf2. The studies were directed at understanding the extraction behaviour of the metal ions and to devise separation methods. Apart from this, it was also aimed at understanding the mechanism of extraction by the conventional ‘slope analysis’ method along with techniques such as UV-vis spectroscopy and time resolved fluorescence spectroscopy (TRFS). The application of a newly developed solvent system for nuclear fuel cycle applications can get acceptance after the sustainability for long term reusability is established. Keeping this in mind, radiolytic stability and stripping studies were also carried out.
PO-TSIL was synthesized in two steps,13 the first step involving preparation of the TSIL with methanesulfonate as a counter anion (Scheme S1 in ESI†). In a subsequent reaction, the product PO-TSIL with bis(trifluoromethane)sulfonamide (NTf2−) counter anion was prepared (Scheme S2 in ESI†). The products were characterized by NMR and HR-MS (ESI†).
The extraction of actinide ions by RTILs takes longer time to attain equilibrium as compared to molecular diluents in view of factors such as higher viscosity5b and complex extraction mechanism.5a The time required to attain equilibrium distribution coefficient values for UO22+ extraction was found to be dependent on the feed HNO3 acid concentration rather than the nature of the RTIL diluent (ESI†). For the same acid concentration, Pu4+ extraction kinetics was faster as compared to that of UO22+ (ESI†).
PO-TSIL was evaluated for the extraction of UO22+ and Pu4+ ions as a function of feed nitric acid concentration and the results are presented in Fig. 2. For comparison purpose, UO22+ extraction data are also presented using 0.05 M TOPO in [OMIM]NTf2 and n-dodecane making the extraction systems nearly identical. As seen from the figure, the extraction mechanism of TOPO in [OMIM]NTf2 and n-dodecane resemble each other and appear to involve neutral species as reported previously.12 On the other hand, a cation-exchange mechanism appears to be valid for the extraction of the metal ion when solutions of PO-TSIL in [OMIM]NTf2 of [BMIM]NTf2 were used.
Fig. 2 Dependence of metal ion extraction on acid concentration. (a) UO22+–TSIL system; (b) Pu4+–TSIL system. |
Careful observation of the extraction profiles of UO22+ and Pu4+ (Fig. 2) in PO-TSIL suggests that while the extraction of UO22+ decreased with HNO3 concentration, an entirely opposite trend was seen for Pu4+. Contrary to the report of ion-pair species extraction for UO22+ extraction by TOPO–RTIL solvent system, the present results indicate a cation extraction mechanism with possible extracted species as UO2(TSIL)x(NTf2)y (2+x−y)+IL. On the other hand, Pu bearing species were neutral ion-pairs of the type, Pu(TSIL)n(X)4+n, where X− = NTf2− or NO3− (vide infra).
In order to further ascertain the nature of the extracted species, it was required to determine the number of PO-TSIL units present in the extracted species. Conventional ‘slope analysis’ (ESI†) suggested the presence of two units of PO-TSIL in the Pu4+ bearing extracted species in both [OMIM]NTf2 and [BMIM]NTf2, thereby prompting us to suggest extraction of species of the type, Pu(TSIL)2(X)6 and the extraction equilibrium can be given as:
Pu4+ + 2TSIL+IL + 6X− = Pu(TSIL)2(X)6,IL | (1) |
UO22+ + yX− + xTSILIL+ + (2 + x − y)NMIMIL+ = UO2(TSIL)x(X)y(2+x−y)IL+ + (2 + x − y)NMIM+ | (2) |
The extraction of other important actinide and fission product radionuclides present in radioactive wastes such as Am3+ (representative trivalent minor actinide), Eu3+ (representative trivalent lanthanides), Cs+ and Sr2+ was also studied. The extraction data (Table 1) suggested extraction of only Pu4+ and UO22+ while the other metal ions were not extracted to any significant extent. Although Sr2+ was not extracted at all, Cs+ was extracted to a very small extent. Careful analysis of the extraction data indicated Pu4+ was preferentially extracted as compared to UO22+ in the PO-TSIL in both the RTIL diluents. Secondly, [OMIM]NTf2 was found to be a better diluent as compared to [BMIM]NTf2. Finally, while TOPO was a better extractant as compared to PO-TSIL in [OMIM]NTf2, an opposite trend was seen in [BMIM]NTf2. Though many TSILs result in enhanced extraction as compared to analogous ionic liquid based solvent systems such as the diglycolamide-functionalized TSIL,11 results similar to the one observed in the present study with [BMIM]NTf2 as the diluent, where the TSIL led to lower extraction as compared to analogous RTIL based solvent, was also reported by us using a CMPO-functionalized TSIL.9b Furthermore, the selectivity changes with the aqueous phase nitric acid concentration. As seen from Fig. 2, the extraction of Pu4+ is significantly higher as compared to that of UO22+ at 2–3 M HNO3, the selectivity becoming about 10 times (DPu/DU) with [OMIM]NTf2 at 3 M HNO3. The higher extraction of Pu4+ vis-à-vis UO22+ is in sharp contrast to the extraction trend observed with TBP in the PUREX process. The viscosity of the TSIL phase was found to decrease which is attributed to water extraction (ESI†). As the solvent extraction studies are carried out from aqueous feeds, the RTIL phase is always containing the co-extracted water. Therefore, the distribution and the selectivity data always refer to the water saturated ionic liquid phase.
Solvent systema | Distribution coefficient | |||||
---|---|---|---|---|---|---|
Am3+ | Pu4+b | UO22+ | Eu3+ | Cs+ | Sr2+ | |
a Concentration of the extractant: 0.05 M PO-TSIL in the respective ionic liquid.b NaNO2 was used as the holding oxidant. | ||||||
PO-TSIL in [BMIM]NTf2 | <1 × 10−3 | 9.8 ± 0.1 | 9.12 ± 0.10 | <1 × 10−3 | 0.067 | <1 × 10−3 |
PO-TSIL in [OMIM]NTf2 | <1 × 10−3 | 13.5 ± 0.4 | 9.90 ± 0.30 | <1 × 10−3 | <1 × 10−3 | <1 × 10−3 |
TOPO in [BMIM]NTf2 | <1 × 10−3 | 3.05 ± 0.05 | 3.63 ± 0.11 | <1 × 10−3 | 0.005 | <1 × 10−3 |
TOPO in [OMIM]NTf2 | <1 × 10−3 | 135.5 ± 16.1 | 22.9 ± 1.1 | <1 × 10−3 | <1 × 10−3 | <1 × 10−3 |
Stripping of the metal ions is an integral part of the evaluation any solvent systems being developed for actinide extraction not only for the recovery of the metal ions but also from recycling of the solvent point of view. Several complexing agents were tested for the stripping of both UO22+ as well as Pu4+ and the results are presented in Table 2. Apart from these, stripping of UO22+ was also attempted using 8 M HNO3 which was found not to be very effective. Effective stripping of UO22+ (>99%) was seen with 0.05 M EDTA in 1 M guanidine carbonate which was reported previously to be effective for the back extraction of rare earth metal ions from CMPO ionic liquid extracts.14 While Pu4+ could be effectively stripped using 0.5 M oxalic acid, Na2CO3 solutions was effective for U stripping only from [OMIM]NTf2. The lower stripping efficiency from [BMIM]NTf2 was attributed to higher acid uptake in that medium which destroyed part of the carbonate decreasing its effectiveness (ESI†). The stripping kinetics was slow similar to the extraction kinetics (ESI†).
Stripping agent | % Stripping | |||
---|---|---|---|---|
[BMIM]NTf2 | [OMIM]NTf2 | |||
UO22+ | Pu4+ | UO22+ | Pu4+ | |
8 M HNO3 | 66.3 | — | 56.8 | — |
0.05 M EDTA + 1 M guanidine carbonate | 99.9 | 98.4 | 99.2 | 99.3 |
1 M Na2CO3 | 87.7 | — | 99.2 | — |
0.5 M oxalic acid | — | 99.9 | — | 99.5 |
Radiolytic stability of the TSIL was ascertained by carrying out the extraction of UO22+ ion after exposing the former to an absorbed dose of 530 kGy. The results (Fig. 3) indicated that though the extraction of Pu4+ was affected to a very large extent, that of UO22+ was not affected to such an extent. For U extraction, degradation was lower with [OMIM]NTf2 than those seen with [BMIM]NTf2. For comparison purpose, solutions of TOPO in ionic liquids were subjected to similar treatment and the results showed their relatively higher radiolytic instability as compared to the TSIL (Fig. 3).
Fig. 3 Effect of irradiation on extraction of Pu(IV) and U(VI), aq. phase: 1 M HNO3, equilibration time: 3 h, [TSIL] or [TOPO]: 0.05 M. |
UV-visible spectra of UO22+ extracts in TOPO and PO-TSIL in both [BMIM]NTf2 and [OMIM]NTf2 are presented in Fig. 4 along with the spectra of uranyl nitrate solution which shows that the spectra of the extracts are nearly identical suggesting equivalent complexation by both the ligands, although a red shift was observed compared to the hydrated uranyl ion indicating strong complexation by the phosphine oxide group in TOPO or PO-TSIL and one or more nitrate anions. Our previous work on UO22+ extraction using TOPO in ionic liquids has suggested extraction of species of the type, (UO2·2TOPO)2+(NTf2−)2. Considering the similarities between the spectra of the TOPO and PO-TSIL extracts of U, and also considering cation exchange mechanism, species of the type (UO2·2TSIL)4+ may be proposed. Additional evidence for the nature of the extracted species comes from ESI-MS spectra (ESI†).
A look at the photoluminescence spectra of uranyl ion in aqueous HNO3 medium and the extracts generated after complexation of UO22+ ion with PO-TSIL in [BMIM]NTf2 and [OMIM]NTf2; and TOPO in [BMIM]NTf2 (Fig. 5) revealed that the nature of the extracted species were entirely different in all the cases not only due to the shifts of the emission maxima but also the differences in the relative intensities of the vibronic structures in the emission profiles (ESI†). The symmetric stretching frequency of U–O bonds of uranyl moieties were found to be 793 cm−1 and 409 cm−1, respectively for aqueous uranyl ion and U-TOPO extract in [BMIM]NTf2 which were in good agreement with that for UO3, xH2O (ref. 15) and UO22+–TOPO complex in [OMIM]NTf2 reported in literature.12 The U–PO-TSIL complex showed the vibronic stretching frequencies at 446 cm−1 and 498 cm−1 in [OMIM]NTf2 and [BMIM]NTf2, respectively. The decrease in the stretching frequency in complexed forms compared to the aqueous uranyl ion can be attributed to the decrease in bond strength of U–O bonds in OUO moieties on complexation. The oxygen to uranyl charge transfer was found to be unfavoured by the approach of 2 ligands molecules along the equatorial plane of the uranyl ion. The symmetric stretching frequency of uranyl oxygen obtained from the emission spectra revealed that in the UO22+ TSIL complex, the U–O bonds were shorter for the PO-TSIL complex compared to that of analogous complex with TOPO. Due to the larger size of the TSIL, their approach towards metal ion is sterically hindered which favoured the oxygen to uranium charge transfer and strengthening the U–O bonds of uranyl moieties. Similarly, the ground state frequency of symmetric stretching vibration of UO2Cl42− in [DMIM]Br16 and [BMIM]NTf2 (ref. 17) were reported as approximately 750 cm−1 and 825 cm−1, respectively. The luminescence decay profiles (ESI, Fig. S9†) revealed the presence of single species in case of aqueous uranyl ion, U–TOPO extract in [BMIM]NTf2 and U–PO-TSIL extract in [OMIM]NTf2 whereas for U–TSIL extract in [BMIM]NTf2 showed the bi-exponential nature of the decay profile revealing the presence of two species.
Fig. 5 Luminescence spectra of (a) aq. uranyl, (b) U(VI)–TOPO extract in [BMIM]NTf2 (c) U(VI)–PO-TSIL extract in [OMIM]NTf2 and (d) U(VI)–PO-TSIL extract in [BMIM]NTf2. |
In conclusion, the PO-functionalized TSIL has been used for the extraction of actinides for the first time. The solvent extraction data, with the PO-TSIL suggested significant extraction of both UO22+ and Pu4+ and almost no extraction of the trivalent (lanthanide or actinide), bivalent or monovalent ions. The stripping of the extracted actinide ions was effective with suitable stripping agents such as EDTA in guanidine carbonate for both UO22+ and Pu4+ and oxalic acid for Pu4+. Though these results appear promising, the insufficient radiation stability, particularly for Pu4+ extraction suggest that the PO-TSIL may not be considered as a suitable alternative for TBP in the PUREX process.
Footnote |
† Electronic supplementary information (ESI) available: Synthesis of TSIL, solvent extraction data, etc. See DOI: 10.1039/c5ra24174j |
This journal is © The Royal Society of Chemistry 2016 |