Iman A. Hassana,
Sanjayan Sathasivamab,
Husn-Ubayda Islama,
Sean P. Nairc and
Claire J. Carmalt*a
aMaterials Chemistry Centre, Department of Chemistry, University College London, 20 Gordon Street, London WC1H 0AJ, UK. E-mail: c.j.carmalt@ucl.ac.uk; Fax: +44 (0)20 7679 7463
bBio Nano Consulting Ltd, The Gridiron Building, One Pancras Square, London N1C 4AG, UK. E-mail: info@bio-nano-consulting.com; Fax: +44 (0)20 7396 1056
cDivision of Microbial Diseases, UCL Eastman Dental Institute, 256 Gray's Inn Road, London, WC1X 8LD, UK
First published on 3rd January 2017
This paper reports on a Ga2O3–Cu2O composite thin film that allows the destruction of both Gram negative and Gram positive bacteria via a dual mechanism involving Ga3+ ions that disrupt Fe3+ metabolism pathways in bacteria as well as through the reactive oxygen species generated by possible Fenton type reactions that are mediated by Cu1+ ions. This dual mechanism allowed the highly transparent composite thin film to destroy both E. coli and S. aureus to below detection limits in 24 hours and limits the build up of bacterial resistance. The composite film was amorphous and the nature of the Ga and Cu species was extensively analysed on the surface and the bulk using X-ray photoelectron spectroscopy and synchrotron radiation involving linear combination analysis (LCA) and the X-ray absorption near edge structure.
The use of conventional antimicrobials to fight such infections is becoming less effective due to the increasing occurrence of multidrug resistant bacteria.2,3 Hospital and health care environments represent a reservoir for multidrug resistant bacteria and therefore new methods for reducing or eliminating microorganisms from these environs using antibacterial coatings consisting of (for example) metals and metal oxides with antibacterial properties on high contact touch surfaces, such as keyboards and door handles, is desirable.4–6
One of the most well known antibacterial agents is Cu in the metallic or oxide form. It has been used for centuries to decontaminate water. The mode of action is complex, but is believed to be through Fenton type reactions that involve the production of reactive oxygen species (ROS) which go on to cause damage to bacterial cell membranes, DNA and proteins through oxidative stress.7,8 Although a potent antibacterial agent, Cu and its oxides are expensive relative to other metals (and metal oxides), thus making the use of Cu costly when application of the coatings on large areas, such as those found in hospitals, is required. Furthermore, the use of Cu or Cu2O, CuO causes aesthetic concerns, as the coatings are not transparent but coloured.
Gallium oxide however is highly transparent in the visible and displays antibacterial activity. Ga has demonstrated harmful effects on microorganisms, particularly in mechanisms involving the metabolism of iron.1 Gallium has been used in biological studies despite having no known physiological functions in the human body. The mechanism for the antimicrobial activity of gallium (Ga3+) has been related to its ability to mimic iron (Fe3+) but not to participate in redox reactions. Gallium is able to compete with iron and interferes with the absorption and activity of Fe3+. Gallium with a trivalent charge (Ga3+) has an ionic radius of ∼0.55 Å that corresponds well with Fe3+ (∼0.5 Å). This can allow Ga3+ to displace Fe3+ in biochemical molecules and pathways. However, iron is redox active but gallium is not. Therefore, the substitution of Fe3+ with Ga3+ will lead to the inactivation of Fe-dependent biomolecules. Iron is important for cell division and essential for the formation of DNA. Therefore disruptions in the absorption of iron can cause the cells not to be able to produce sufficient DNA for replication, which ultimately leads to its death.1–3
Antimicrobial activity of gallium has been demonstrated with in vitro investigation of gallium in the form of gallium maltolate9,10 and gallium nitrate.11,12 Studies have shown that gallium nitrate can inhibit the growth of biofilms. Biofilms were grown in the presence and absence of low concentration of gallium nitrate and it was observed that limiting the presence of Fe in the nutrients had a positive correlation with the concentration of Ga and microbial reduction was observed. However, when Fe was introduced into the medium, competition between the Ga3+ and Fe3+ occurred causing the antimicrobial activity of Ga to decrease.13,14
The antimicrobial activity of Ga3+ was also investigated using Ga2O3-doped phosphate-based glasses (PBGs). PBGs are durable materials used as wound dressings where antibacterial ions are incorporated. This unique system would be able to deliver Ga3+ as the glass degrades. The tests demonstrated that the PBGs had antibacterial effects on different HAI bacterial agents. Results indicated that 1% mol Ga2O3-doped PBG was sufficient to be potent against a range of organisms tested. Investigation on Ga2O3 nanoparticles have shown that they interfere with the adhesion mechanism of bacterial strains and reduce the formation of biofilms.14
The use of a composite Ga2O3–Cu2O film that contains both Ga and Cu ions would allow a dual mode of attack against bacteria via (1) the disruption of bacterial Fe3+ metabolism by Ga3+ ions as well as (2) attack through Cu and ROS. Thus making the development of bacterial resistance unlikely. In addition to this, the composite films rich in Ga remain highly transparent in the visible, unlike pure Cu2O or CuO films, therefore allowing application as coatings in hospital and health care environments. In this paper we show the synthesis, to the best of our knowledge, of the first (film or powder) composite Ga2O3–Cu2O sample and subsequent tests against both Gram-negative and Gram-positive bacteria. The films were prepared using a novel route called aerosol assisted chemical vapour depositon (AACVD) that is simple and easily scalable.15–20 Furthermore, since the as-deposited films were X-ray amorphous characterization was carried out using both X-ray photoelectron spectroscopy and linear combination analysis/X-ray absorption near edge structure to determine the nature of Ga and Cu species on the surface and bulk respectively.
A graphite block containing a Whatman cartridge heater was used to heat the glass substrate. The temperature of the substrate was monitored by a Pt–Rh thermocouple. Coated substrates were handled and stored in air. Large pieces of glass (ca. 4 cm × 2 cm) were used for X-ray powder diffraction but the coated substrate was cut into ca. 1 cm × 1 cm squares for subsequent analysis.
GaMe3 were used as supplied from SAFC HiTech. GaMe3 is pyrophoric and hence manipulations were performed under a dry, oxygen-free dinitrogen atmosphere using standard Schlenk techniques or in an Mbraun Unilab glovebox. All solvents and alcohols commercially procured from Aldrich were dried with anhydrous engineering equipment and stored in Young's tap flasks.
Both films were also deposited on quartz substrates and annealed at 1000 °C for 12 hours under air to subsequently determine the crystallographic phase through X-ray diffraction.
X-ray absorption spectroscopy (XAS) measurements on the Dutch-Belgian Extended X-ray absorption fine structure (EXAFS) beamline (BM26A) at the ESRF in Grenoble. Monochromatic radiation was supplied by a double Si(111) crystal, and fluorescence was measured using a 9 element germanium solid state detector. XAS of the film was acquired in fluorescence. Measurements of the thin film and pelletized copper standards were taken on the copper K-edge (8987 eV). XAS data were processed and X-ray absorption near edge structure (XANES) analysis was performed using Horae Athena software, and detailed EXAFS analysis was performed on Excurve version 9.273.
Prior to use, the gallium oxide and copper gallium oxide samples were cut into 1 × 1 cm sections. A humidity chamber was created to ensure that the suspensions did not dry out. For each exposure time, triplicate samples were analysed and uncoated barrier glass pieces were used as a control. Each exposure time was also repeated twice. A 25 μl aliquot of the bacterial cell suspension was spread evenly on the surface of each slide and incubated at room temperature (21 ± 2 °C) for the allocated exposure time. After incubation the slides were aseptically transferred to 225 μL PBS and vortexed for 30 seconds to release the bacteria into the solution. Serial dilutions of the resulting bacterial suspensions were prepared in PBS and 25 μL from each dilution was spread on to MacConkey Agar (Oxoid, Basingstoke, UK) for E. coli and BHI agar (Oxoid, Basingstoke, UK) for S. aureus. Plates were allowed to dry before inverting and incubating aerobically at 37 °C for 24 hours. After incubation, any bacterial colonies were counted and the viable count calculated. The Mann–Whitney U test was used to determine the significance of the antimicrobial activity of gallium oxide and copper gallium oxide compared to the control glass slide. As well as, determining the significance of the activity of gallium oxide compared to the copper–gallium oxide.
The deposited films were amorphous when probed using X-ray diffraction spectroscopy. This is expected as Ga2O3 and related systems only exhibit crystallinity at temperatures of 700 °C and above. Annealing of the as-deposited thin films at 1000 °C (to maximize crystallinity) in air for 12 hours did indeed produce crystalline β-Ga2O3.
The composite film, when annealed, showed the growth of the β-Ga2O3 and CuO phases (Fig. 1). There was no evidence for the formation of the spinel phase that has previously been isolated for AACVD synthesized Ga2O3 and CuO composite films when annealed under vacuum.21 As a result, further discussion in this manuscript will focus solely on the amorphous as-deposited films of pure Ga2O3 and composite Ga2O3–Cu2O.
Fig. 1 PXRD patterns of the annealed pure and composite film. The standard patterns for β-Ga2O3 and CuO are also shown. |
Energy dispersive X-ray spectroscopy (EDX) showed the composite film to be rich in Ga with only 21 at% being composed of Cu compared to 79 at% Ga. The composite film being Cu poor allows it to remain highly transparent without any colour thus enabling it to be applied as a coating on a wider range of surfaces without any issues with aesthetics.
The nature of the Ga and Cu species on the surface of the amorphous composite film was determined by X-ray photoelectron spectra (XPS). The Ga 2p3/2 and 3d5/2 transitions appear at 1117.9 and 19.9 eV, matching well with literature reports for Ga3+.22,23 The Cu 2p spectrum shows two symmetrical peaks separated by 19.6 eV with a low signal to noise ratio. The Cu 2p3/2 peak centered at 932.6 eV can correspond to Cu0 and/or Cu1+ as both peaks overlap heavily.24,25 The ratio of Ga to Cu on the surface was 7 (86 at%) to 1 (14 at%). This is slightly different to what was observed from EDX, which suggests that there was more Cu present in the bulk of the films compared to the surface. The valence band XPS spectra for both films is shown in Fig. 2d. The valence band of pure Ga2O3 is broad, with a width of ca. 10 eV and generalized gradient approximation GGA of density functional theory (DFT) suggests that it is primarily composed of O 2p states.26 Other calculations (tight binding) have however suggested that the valence band of Ga2O3 may also consist of O 2p, Ga 4p and Ga 4s states.26,27 The composite film shows a similar spectrum to the pure film but is shifted to lower binding energies by ca. 1 eV.
Fig. 2 XPS core level spectra for the composite film showing the (a) Ga 2p, (b) Ga 2d and (c) Cu 2p transitions. (d) Shows the valence band spectra. |
The oxidation of the Cu and Ga species in the bulk of the pure Ga2O3 and composite Ga2O3–Cu2O films were analysed using linear combination analysis (LCA) and X-ray absorption near edge structure (XANES). Cu K-edge XANES data for the sample is shown in Fig. 3 along with the corresponding data for standard powders: Cu, Cu2O and CuO. The energy scales of all the spectra have been consistently normalised. Fig. 3 shows that the local environment of Cu can have an effect on the line shape of the XANES spectra, therefore making it fairly simple to identify the nature of Cu present in the Ga2O3–Cu2O films. The prominent feature seen in the Cu K-edge spectra (Fig. 3a) is from the allowed 1s to 4p transition.28 A low energy peak situated at ca. 8982 eV matches for Cu(0) species in the Cu standard powder, this peak is shifted to a higher energy of ca. 8985 eV and ca. 8987 eV for Cu(I) (Cu2O standard powder) and Cu(II) (CuO standard powder) respectively. All these peak positions match closely with literature reports.28,29
In this case, the XANES spectra for the amorphous Ga2O3–Cu2O films match that of Cu, Cu2O and CuO standards indicating that copper is present in the film in all three oxidation states. This is in contrast to the surface of the film that XPS analysis showed to be lacking in CuO. LCA for the Ga2O3–Cu2O (Table 1) calculated the Cu:Cu2O:CuO ratio present in the film is 0.37:0.60:0.03. The XANES data indicates that Cu, Cu2O and a very small amount CuO were identified. XPS only identified the presence of Cu2O on the surface of the material. This could be due to CuO not being present at the surface but can be detected in the bulk of the film. The LCA also shows that Cu2O has the largest amount in the ratio, which corresponds to the identification that the composite is a Ga2O3–Cu2O material.
LCA of XANES of Ga2O3–Cu2O | ||
---|---|---|
Standard | Ratio | R-factor |
Cu2O | 0.60 (0.03) | 2.51 × 10−4 |
CuO | 0.03 (0.02) | |
Cu | 0.37 (0.02) |
EXAFS fit of Ga2O3–Cu2O | |||||
---|---|---|---|---|---|
Scatter | N | RXRD (Å) | REXAFS (Å) | σ2 (Å2) | F |
O | 2.0 | 1.85 (Cu2O) | 1.87 (0.03) | 0.010 | 12 |
1.95 (CuO) | |||||
Cu | 4.6 | 2.54 (Cu) | 2.55 (0.02) | 0.010 |
EXAFS were analysed and revealed the presence of two distances (Table 1). The local structure of Cu2O with two Cu–O distances that were found to be 1.87 Å, which corresponds to bond distances found in Cu2O (1.85 Å). The Cu–Cu distances were identified as 2.55 Å, which is comparable to Cu–Cu bond distance found in pure copper films (2.54 Å).
An important factor that determines efficiency of antibacterial coatings is the surface area. A more nano- and micro-structured morphology of an active film allows it to rapidly destroy bacteria purely through increased contact. This is the primary reason why nano powders show increased activity compared to bulk powders of the same materials. Scanning electron microscopy (SEM) was used to determine the surface topography of both the as-deposited Ga2O3 and Ga2O3–Cu2O amorphous films and give only a qualitative indication of the differing surface area. The Ga2O3 film consists of fused particles roughly 100 nm in diameter. This film appeared to have a larger surface area compared to the composite film that showed much larger particle sizes at 400 nm (Fig. 4). Cross sectional SEM imaging showed both films to be 500 nm thick.
Optical properties of the Ga2O3 and composite Ga2O3–Cu2O were studied by transmission and reflectance measurements between 300–2500 nm by UV-Vis spectroscopy (Fig. 5). Both of the amorphous films showed a slight shift in the adsorption edge towards the visible relative to plain glass substrate and displayed minimal reflectively (10–20%). The Ga2O3 films displayed high transmission (85–90%) whereas the composite was slightly lower in transmission (80–85%).
The antimicrobial properties of the amorphous Ga2O3 and Ga2O3–Cu2O films deposited from GaMe3 in methanol or a mixture of GaMe3 and [Cu(NO3)2·3H2O] via AACVD at 450 °C were tested against E. coli and S. aureus. Samples were cut in 1 × 1 cm sample sections and were covered with 25 μL of bacterial cell suspension containing approximately 105 cfu. Through enumeration and plating of the bacterial suspensions and subsequent overnight incubation (37 °C), the resultant viable counts of bacteria for each sample section was determined. The results for the Ga2O3 and Ga2O3–Cu2O films, shown in Fig. 5, demonstrate that the films have antimicrobial activity against E. coli and S. aureus. Glass cut into 1 × 1 cm were used as controls. Each point represents the log10 of the mean number of viable bacteria from three samples and error bars represent the standard error. The results for the films show that having both Ga and Cu in the films has an enhancing effect on the antimicrobial activity.
For E. coli, a 0.9log10 reduction (P < 0.01) in viable bacteria was observed after 24 hours, for Ga2O3, as shown in Fig. 6a. In the case of Ga2O3–Cu2O, the same reduction in colony counts was achieved after only 9 hours (P < 0.001) and 4log10 reduction was observed after 24 hours. This was similar for S. aureus, a 1.2log10 reduction (P < 0.001) for Ga2O3 was observed after 24 hours however, for the Ga2O3–Cu2O samples a 0.8log10 reduction was observed after 9 hours (P < 0.001) and 4log10 reduction after 24 hours (P < 0.001). When the antimicrobial activity of the Ga2O3 thin films prepared in this study are compared to previous studies where Ga2O3-doped phosphate-based glasses were tested against Pseudomonas aeruginosa a similar reduction in the viable count was seen (0.86log10 reduction).9,10 Overall Ga2O3 has been demonstrated to have some antimicrobial activity. With the Ga2O3–Cu2O film, a much greater bacterial reduction was observed. When comparing the difference in the viable count between Ga2O3 and Ga2O3–Cu2O, it was seen to be highly statistically significant (P < 0.001) demonstrating the impact of copper on the sample. The Ga2O3–Cu2O has a much improved antimicrobial efficacy over Ga2O3 due to the addition of an antimicrobial metal, copper in a mixture of Cu2O. Copper has been shown to produce highly significant reductions in the number of bacteria responsible for HAI. The results herein show that Ga2O3–Cu2O coatings have lower antimicrobial activity compared to Cu and Cu2O coatings.5 It has been shown that copper coatings can reduce bacterial numbers in 30 minutes rather than 24 hours. However, the Ga2O3–Cu2O films we developed were transparent and have the potential to be deposited on a wide variety of surfaces.
Fig. 6 The antibacterial properties of the pure Ga2O3 and composite Ga2O3–Cu2O thin films as tested against (a) E. coli and (b) S. aureus. |
This journal is © The Royal Society of Chemistry 2017 |