Hyeokjin Yoon and
Jung Sang Suh*
Department of Chemistry, Seoul National University, Seoul 08826, Republic of Korea. E-mail: jssuh@snu.ac.kr; Fax: +82-2-875-6636; Tel: +82-2-880-7763
First published on 31st May 2017
We developed a method to fabricate sensitive and stable substrates that can be used in routine surface-enhanced Raman scattering (SERS) spectral measurements. The substrates were fabricated by immobilization of Ag colloidal particles on a glass plate coated with poly(4-vinyl pyridine) (P4VP), adsorption of molecules on the immobilized colloidal particles, and second immobilization. In the second step, we adsorbed weakly adsorbed molecules such as aniline instead of target molecules. We purified pristine silver sols by centrifuging to increase the surface charge of the colloidal particles and optimized Ag colloidal particle diameter to achieve high Raman signal enhancement from their dimers. When purified silver sols were used in the immobilizations, dimers were predominantly formed with very few trimers. When target molecular solutions were dropped in arrays on the substrate prepared by adsorbing aniline and dried, a good SERS spectrum was observed from each spot without any peaks of aniline and P4VP. The average enhancement was found to be 1.0 × 107 and the enhancement of the dimers was ∼1.6 × 107. The latter corresponds to the enhancement outside the hotspot regions, since target molecules could not be adsorbed at the junctions after the formation of dimers. About one hundred samples could be tested on the substrate fabricated on a cover glass when target molecular solutions were dropped by using a micropipette. Since dropping and drying are very simple and easy processes, and many samples could be tested on a substrate, our substrates can be used in routine SERS spectral measurements and assays like bioassays.
Ag colloidal particles are one of the most commonly used SERS substrates.13–15 Their synthesis is relatively simple and they show a very high surface enhancement.16–20 However, controlling their aggregation is difficult.21–23 In 2011, Lee et al.24 of our group developed a three-step immobilization method to fabricate stable clusters of metal colloidal particles. One year late, Lu et al. reported a three-step electroless deposition method.25 This method consists of three steps: immobilization of the colloidal particles on a cover glass coated with poly(4-vinyl pyridine) (P4VP), adsorption of target molecules on the immobilized colloidal particles, and second immobilization. With increasing the second immobilization time, large clusters of Ag colloidal particles such as trimers and tetramers were also formed significantly along with the dimers, and in the extinction spectrum the λmax of the longitudinal LSPR peak was red-shifted. Like increasing the box size in the particle in-a-box models, the energy gap between the successive energy levels decreases with increasing the cluster size, and the λmax of the longitudinal LSPR peak is red-shifted with increasing the cluster size.26 However, a good SERS spectrum was observed from the substrate, with enhancement of ∼1 × 106.24 Herein, we report the usefulness of the substrates prepared by adsorption of weakly adsorbed molecules such as aniline, instead of target molecules, in the second step. By using purified silver sols in the immobilizations, we could form dimers predominantly. Also, we optimized the colloidal particle diameter to achieve high Raman signal enhancement from their dimers. When target molecular solutions were dropped in arrays on the substrate prepared by adsorbing aniline and dried, a good SERS spectrum was observed from each spot without any peaks of aniline and P4VP. When target molecular solutions were dropped by using a micropipette, about one hundred samples could be tested on the substrate fabricated on a cover glass. Since dropping and drying are very simple and easy processes, and many samples could be tested on a substrate, our SERS substrate can be used in routine SERS spectral measurements and assays like bioassays.
P4VP (0.3 g) was dissolved in ethanol (100 mL). 100 μL of this polymer solution was dropped on a cover glass (2.2 cm × 2.2 cm) and then the glass plate was rotated at 3000 rpm for 1 min. The surface of the cover glass was then washed by dipping it in ethanol several times. The cover glass coated with P4VP was placed in a Petri dish containing 3.0 mL of silver sols to immobilize Ag colloidal particles on it. After immobilization, the surface was washed with ethanol and then the cover glass was dried by blowing nitrogen gas. To adsorb aniline on the immobilized Ag colloidal particles, the cover glass was dipped in a 3.0 mL ethanol solution of aniline (200 nM) for 2 h. After washing the surface with ethanol, the cover glass was again placed in the Petri dish containing the 3.0 mL colloidal solution of Ag for various durations to immobilize more colloidal particles. The surface of the cover glass (SERS substrate) was then washed with ethanol and dried. To adsorb target molecules on the substrate, the substrate was dipped in a 3.0 mL ethanol solution of target molecules (100 nM) for 2 or 24 h or 20 μL ethanol solutions of target molecules (100 nM) were dropped in arrays on the substrate using a micropipette (Scheme 1).
SERS and normal Raman spectra were observed by using a micro-Raman system equipped with a homemade sample stage, monochromator (SPEX 500 M), and CCD camera cooled with liquid nitrogen (Roger Scientific 7346-001 Model). A 514.5 nm Ar-ion laser line was used as the excitation source. The laser power incident on the sample was approximately 10 μW, and acquisition times of 1 and 10 s were used. The Raman spectrum of liquid benzenethiol was obtained from a sample contained in a capillary (364 μm in diameter). Raman frequencies were corrected by using the Raman peaks of a mixture of toluene and acetonitrile (1:1 v/v). The UV-Vis absorption spectra of Ag colloidal particles immobilized on the cover glass coated with P4VP were obtained by a transmission method. As the reference material, the cover glass coated with P4VP was used. The morphology of the particles was analyzed by using a scanning electron microscope (SEM; JEOL ltd. JSM6700F (10 kV)) and high-resolution transmission electron microscope (HR-TEM; JEOL, JEM-3000F (300 kV)).
Consider the effect of purification of silver sols to the cluster formation. Silver sols are very stable without formation of precipitation because the colloidal particles have the same kind of surface charge, and hence repel each other. It should be noted that for the fabrication of silver sols used in this study, sodium citrate and silver nitrate were added as a stabilizer and reagent, respectively. In addition, sodium ascorbate and sodium borohydride were added as reducing agents. Therefore, the Ag colloidal particles of silver sols were surrounded by the ions present in the colloidal solutions such as citrate, nitrate, borate, sodium, etc., and their surface charge was reduced significantly. The pristine sols were purified by removing the supernatant obtained after centrifuging them, and then adding the same volume of distilled water to the residue left behind. Consequently, the concentration of the ions present in the colloidal solutions was significantly reduced by purification. Therefore, the net surface charge of the colloidal particles increased and the repulsion force between the colloidal particles increased significantly. There is no doubt that the probability of their aggregation during the immobilization would decrease with an increase in the force of repulsion between the Ag colloidal particles. This is the reason why the Ag colloidal particles in the substrate prepared using purified silver sols were immobilized individually without any formation of clusters (Fig. 1a). When molecules were adsorbed on Ag colloidal particles, the surface charge was reduced, and the force of repulsion between the colloidal particles reduced. This can result in the aggregation of colloidal particles. Actually, dimers were formed predominantly, while trimers very few, during the second immobilization after the adsorption of aniline (see Fig. 1b–d). However, when pristine silver sols were used in the immobilization, colloidal particle clusters such as dimers, trimers, and tetramers were formed randomly during the second immobilization (see ref. 24 and Fig. S2†). Therefore, it is concluded that the formation of trimers and tetramers is prohibited when purified silver sols are used in the immobilization. This may be related to the surface charge of the dimers formed. Since the Ag colloidal particles in the purified silver sols had a relatively higher surface charge than that in the pristine sols, it can be expected that the dimers formed from the purified colloidal particles had a higher surface charge than that formed from the pristine ones. Therefore, we believe that the dimers formed from the purified colloidal particles had surface charge densities high enough prevent the attachment of new purified colloidal particles to them. Hence, very few larger clusters such as trimers and tetramers were formed when purified silver sols were used in the immobilization steps.
Fig. 2 shows the SERS spectra of benzenethiol measured from the substrates prepared by the three-step immobilization method and adsorption of aniline in the second step, after dipping each substrate in a 3.0 mL ethanol solution of 100 nM benzenethiol for 24 h and drying. The first immobilization time was all the same as 10 min, and the second immobilization time was varied from 0 to 40 min with a 10 min step. All the spectra are well characterized and have all the same spectral shape. The distinct peaks in the SERS spectra correspond to the modes of the benzene ring of benzenethiol.30 For example, the peak at 1573 cm−1 corresponds to ν8a, while that at 1000 cm−1 corresponds to ν12. The peak at 417 cm−1 corresponds to ν7a and contributions from the C–S stretching vibration (νCS). It should be noted that no peaks corresponding to aniline and P4VP were observed. The highest intensity was observed from the substrate whose second immobilization was 30 min. The SERS intensity increased with an increase in the number of dimers but decreased with red-shifting the λmax from 519 nm by increasing the number of larger clusters like trimers and tetramers at longer second immobilization times. The standard deviation of relative intensities measured at 10 different points of each sample was less than 5% when a laser beam with a diameter of ∼1 μm was used (see Fig. S3 and Table S1†).
Fig. 3 shows the SERS spectra recorded from the spots after dropping several target molecular solutions in arrays on the substrate prepared by the three-step immobilization and adsorption of aniline in the second step, and drying. The first and second immobilization times were 10 and 30 min, respectively. In the second step, the substrate was placed in a 3.0 mL ethanol solution of aniline (200 nM) for 2 h. 20 μL target molecular solutions (100 nM) were dropped by using a micropipette. Each spot produced a very good SERS spectrum. No peaks corresponding to aniline and P4VP were appeared. The spectrum of aniline was very weak (see Fig. S4†). The SERS spectra of the target molecules are well agreed with reported SERS spectra.30–35 For comparison purposes, we also measured the SERS spectra after dipping the substrates prepared by adsorbing aniline in each target molecular solution (see Fig. S4†). The SERS spectra measured after dropping were slightly better in the signal to noise ratio than those measured after dipping. This might be due to a different surface concentration of target molecules between two samples prepared by dipping and dropping.
It should be mentioned that the intensity of the SERS spectrum measured from the substrate prepared by adsorption of a target molecules in the second step is significantly higher than that measured from the substrate prepared by adsorption of aniline after dipping in a target molecular solution (see Fig. S5†). For the former substrate, target molecules are adsorbed on the Ag colloidal particles immobilized during the first immobilization process, and then the dimers are formed in the second immobilization process. Therefore, a certain portion of target molecules exists at the junction region of the dimers. For the latter substrate, target molecules are adsorbed on the surface of all the colloidal particles present on the substrate. However, the dimers have already been formed before taking place adsorption of target molecules. Therefore, in order to be adsorbed at the dimer junction, target molecules need to penetrate into the narrow gap of the junction between two attached colloidal particles. By this reason, target molecules could not be adsorbed at the dimer junction. It is well known that the strongest signal enhancement is obtained from the junctions, which are hotspot sites.7–12 Therefore, the intensity difference of two kinds of substrates is attributed to the fact that some of the target molecules are present at the junctions when the adsorption takes place before the formation of dimers, while none could adsorb at the junctions after the formation of dimers. However, the fabrication by adsorbing target molecules in the second step needs a lot of efforts for measuring SERS spectra of many different target molecules because the substrate for each kind of target molecules must be prepared. On the other hand, many SERS spectra of different target molecules can be measured on the substrate prepared by adsorption of aniline.
By excitation with a 514.5 nm laser line, we obtained the highest enhancement when the λmax of the longitudinal mode of the dimers of Ag colloidal particles was around 519 nm. The optimum value of λmax was slightly greater than the wavelength of the laser line used. This is because of the fact that the SERS intensity is strongly correlated to the extinction at excitation and Stokes wavelengths.36 When a 514.5 nm laser line is used for excitation, for example, the Stokes Raman scattering wavelength becomes greater than the laser line wavelength by 10–45 nm depending on the modes. Therefore, the SERS intensity reaches the maximum value when λmax of the longitudinal mode of Ag dimers is somewhat greater than the wavelength of the laser line used. The λmax of the longitudinal mode of the dimers red-shifted with an increase in the diameter of the metal colloidal particles. A λmax of 519 nm was achieved when dimers were formed from the Ag colloidal particles whose average diameter was about 28 nm.
The average SERS enhancement of the substrate prepared by adsorption of aniline was calculated by comparing the intensity of the 1575 cm−1 peak in the benzenethiol SERS spectrum with that in the normal Raman spectrum. In the preparation of the substrate, the first and second immobilization times were 10 and 30 min, respectively. From the substrate prepared under these conditions, the highest SERS intensity was observed (see Fig. 2). The SERS spectrum was observed after dipping the substrate in a 3.0 mL ethanol solution of 200 nM benzenethiol for 24 h and drying. We assumed that benzenethiol was adsorbed completely on Ag colloidal particles, since benzenethiol was strongly chemisorbed on silver surface, the surface coverage was well below a monolayer, and the adsorption time was long enough as 24 h. The average enhancement factor for the SERS substrate prepared by adsorption of aniline in the second step was founded to be approximately 1.0 × 107 (see Fig. S6† and the calculation). When the substrate prepared by adsorption of aniline was dipped in a benzenethiol solution, benzenethiol molecules would adsorb on the surface of all the colloidal particles of the substrate. However, the molecules adsorbed on the dimers could contribute significantly to the SERS signals. For the SEM image shown in Fig. 1c, there are 73 monomers, 78 dimers, and 5 trimers. If molecules were adsorbed evenly on the surface of all the particles, about 64% of benzenethiol molecules was adsorbed on the dimers. Therefore, the enhancement of the dimers was about 1.6 × 107 [=1.0 × 107/0.64]. Since the adsorption of benzenethiol took placed after the formation of dimers, no benzenethiol molecules could be adsorbed at the junctions of the dimers. Therefore, the enhancement of the dimers corresponded to the enhancement outside the hotspot regions.
The average enhancement of our universal SERS substrates is ∼1.0 × 107. This value is about one order higher than that of the substrates prepared by the three-step immobilization method and using unpurified silver sols whose colloidal diameters were not optimized.24 After dropping the target molecular solutions on our substrates and drying, very good SERS spectra were observed. Therefore, it can be concluded that the substrate prepared by adsorption aniline has a high enough sensitivity for qualitative SERS spectral measurements. A block of 2 mm × 2 mm was large enough to load a sample solution by dropping using a micropipette without overlapping with the nearest neighbor blocks and the SERS spectrum was obtained reliably from each block. Since the substrate fabricated on a cover glass (2.2 cm × 2.2 cm) could be divided into 11 × 11 sampling blocks (2 mm × 2 mm in unit size), about one hundred samples could be tested on the substrate. Therefore, our substrates can be used in assays such as bioassays. Since dropping and drying are very simple and easy processes and many samples could be tested on a substrate, our substrates can be used in routine SERS spectral measurements. In this aspect, we called our substrates as universal SERS substrates.
Footnote |
† Electronic supplementary information (ESI) available. See DOI: 10.1039/c7ra04871h |
This journal is © The Royal Society of Chemistry 2017 |