Microfluidic technologies have emerged as a promising route for precision fabrication of uniform particles. Equipment required for a traditional microfluidic device manufacturing process is expensive and production efficiency is low. It's also difficult to separate a surfactant and continuous phase impurities from particles prepared by a liquid–liquid two-phase shear method. A novel air-blast microfluidic nozzle fabricated using low-cost and efficient 3D printing technology was proposed to prepare calcium alginate particles. Effects of control parameters and solution composition on particle diameters and homogeneity were systematically investigated. Results showed that inlet air pressure has the most significant impact. A nozzle with an outlet diameter of 300 μm can produce particles with diameters ranging from 360 μm to 2100 μm. Coefficients of variation (CV) range from 5.3% to 2.2%. For the same diameter particle prepared, a smaller nozzle outlet had a narrower particle diameter distribution and needed lower inlet air pressure. This method can be used to handle high viscosity solutions and high concentrations of solutions with insoluble solid particles. The prepared particles can be used in biological and pharmaceutical fields.
Alginate droplets can be directly dripped into CaCl2 solution by an air-blast nozzle. There are no surfactants or oil materials and the preparation method is economical, clean, and efficient. Sugiura et al.7 used a silicon surface micromachining method to produce nozzles with an inner diameter of 60 μm, which could prepare 100–300 μm diameter microparticles for cell cultures; the coefficient of variation (CV) was less than 7.5% and the roundness of the prepared particles was more than 0.96. Wang et al.8 embedded a 600 μm diameter glass capillary into a square capillary, which could prepare 670–350 μm diameter quaternized chitosan/alginate/CaCO3 microcapsules where the CV was less than 5%. However, the glass capillaries need to be tapered and assembled manually, which affects the accuracy and hinders their mass production.9,10 Photolithography and deep reactive ion-etching requires complicated manual operations and has a high cost.11,12
3D printing technology, increasingly used in recent years, is more automated and highly repeatable, compared to traditional manufacturing methods, and can print complex structures.13,14 In the last few years, several desktop 3D printers emerging in the market have significantly decreased the cost of 3D printing.15,16 This encouraged researchers to design and develop various 3D-printed microfluidic chips.14–18 Comina et al.19 used a micro-stereo lithography 3D printer to print a flow channel template. Combined with PDMS pouring technology, they could prepare 50 μm to several millimeters chips in 20 minutes. Femmer et al.20 used digital light processing (DLP) 3D printers to print a focusing channel microfluidic consisting of 28 parallel channels that could produce 500 μm diameter particles and achieve amplification of droplet generation by microfluidic technology. Zhang et al.16 used a low-cost Form 1+ printer to create a “plug-and-play” T-type microfluidic device. This device assembled a tubing, a finger tight and a 3D-printed generator together, and could prepare down to ∼50 μm diameter droplets. Wang et al.21 used a fused deposition modelling (FDM) 3D printer (FDM3000) to print an ABS microfluidic chip. Bonyár et al.22 fabricated a microfluidic chip for blood sampling with inkjet 3D printing technology and PDMS casting. The use of CAD or Solidworks models gives users the ability to print microfluidics in a just a few hours and at low cost.
Herein, we propose a 3D-printed air-blast microfluidic nozzle for generating monodisperse droplets. The nozzle is printed using a desktop DLP 3D printer. In addition, the effects of the nozzle diameter, solution concentration, gas and liquid flow rate on the preparation of droplets were also studied. Our calcium alginate microparticles containing solid CaCO3 particles were prepared with this nozzle.
Fig. 1 Schematic diagram of the air-blast nozzle for calcium alginate microparticle preparation: (a) physical drawing; (b) schematic diagram of the preparation; and (c) outlet magnification. |
The dispersed phase channel inlet is directly connected to the Teflon tube, so the inlet diameter is designed according to the Teflon tube fitting (Fig. 1a). The inner diameter of the dispersed phase channel is 2 mm, the outer diameter is 5 mm, and the total length of the liquid flow channel is 27.5 mm. The continuous phase inlet diameter is 3 mm. In order to facilitate the direct insertion of the trachea and ensure no leakage, the inlet has a certain taper. The inner diameter of the continuous phase channel is 7 mm and the outer diameter of it is 10 mm. In order to improve the strength of the T-junction, we designed two symmetrical ribs of 2 mm thickness. According to Fig. 1b, the dispersed phase channel runs directly through the continuous phase channel at the T-junction; this design ensures the gas flows symmetrically from both sides and maintains a uniform distribution of it.
Due to the inherent properties of the 3D printing resin, the printed product will slightly deform after a few days. So, four symmetrical ribs (red part) were added between the two channels as shown in Fig. 1b. These four ribs guarantee a continuous phase channel and dispersed phase channel that are coaxial. In order to minimize the influence of the ribs to the air flow field, the width of them is only 0.5 mm.
Although the resolution of the current desktop printer can reach to 30 μm, the actual printed channel diameter is only 250 μm. During the printing process the uncured resin in the small channel is difficult to remove, so the printed channel cannot be long or complex.23 In order to have low cost and high stability, in this paper the smallest diameter channel was printed about 300 μm. The largest diameter of particles produced by 500 μm outlet nozzles can reach to 2575 μm, which is large enough for the microfluidics field.7,8 Therefore, 500 μm was selected as the largest outlet diameter for printed nozzles. The structure of a slender hole is difficult to print. The channels (Fig. 1c) are designed according to the parameters in Table 1. This design avoids excessive slender holes structures in the nozzle, making it easier to print.
Nozzle parameters | N300 | N400 | N500 |
---|---|---|---|
D1 (mm) | 0.3 | 0.4 | 0.5 |
D2 (mm) | 0.9 | 1.0 | 1.1 |
D3 (mm) | 1.5 | 1.6 | 1.7 |
L1 (mm) | 3.0 | 3.0 | 3.0 |
L2 (mm) | 0.7 | 0.7 | 0.7 |
A larger drag force will be favorable for making smaller droplets. The drag force can be computed as:
FD = 0.5CDAu2ρ. | (1) |
The nozzles were printed with a low-cost desktop printer, B9Creator (B9 Creations, Inc.). The B9Creator is a DLP printer and the maximum printing volume is 104 mm × 75.6 mm × 203.2 mm. DLP is similar to stereolithography; the major difference is the light source. DLP uses a more conventional light source with a deformable mirror device (DMD), which is applied to the entire surface of the vat of photopolymer resin in a single pass, generally making it faster than SL which traces the outline of every part on every pass. One major advantage of DLP is high feature resolution, provided by the process of photo-curing a resin with a UV laser, making it possible to print a smaller hole and stick.13 So, DLP gradually became popular for fabricating droplet-based microfluidic devices since a smooth channel surface is crucial for droplet creation and transportation inside the microchannels. Another benefit of DLP is the diversity of different resins, such as pic100, B9R-CHERRY, B9R-BLACK, B9R-RED, and clear resin. This photo-sensitive resin consists of a modified acrylate oligomer, monomer, and a photoinitiator, but their weight ratio is proprietary. The BLACK resin (Shanghai EETEX Chemical Technology Co., Ltd.) provided the highest precision, so it was used during the experiments.
After printing, the nozzle was immediately put into alcohol and ultrasonically rinsed for 2 minutes, and then a syringe was used to extract alcohol and flush the nozzle internal channels. Finally, the nozzle was ultrasonically rinsed for another 5 minutes to remove the uncured resin.
Different concentrations of sodium alginate solution (Sigma-Aldrich) were used as the dispersed phase. Alginate is a linear copolymer composed of α-L-guluronic acid and β-D-mannuronic acid, and is easily transformed into an ‘egg box’ type hydrogel with multivalent cations such as Ca2+. When the required drug is added to a sodium alginate solution, it can be packed together to form a capsule of a specific function. In this experiment, the SA powder was dissolved in a water bath at 60 °C, cooled to room temperature, and then dropped into a 15 wt% CaCl2 solution through a nozzle to produce solid particles. In order to simulate the effect of insoluble drug loading, CaCO3 microparticles (Sinopharm Chemical Reagent Co. Ltd.) with diameters of 48–75 μm were used as an additive in the experiment.
(2) |
(3) |
Fig. 2 shows the effect of the distance h on the particles shape. When the distance h is more than 40 mm (Fig. 2(a) and (b)), the microparticles have a good spherical shape with almost no oval particles; they were uniform like the gelatin particles prepared by Marcel Workamp's25 nozzle. When the distance h decreased to 20 mm, some oval particles appeared, as shown in Fig. 2(c) and (d). When h continues to decrease, the number of oval particles will increase. Under each experimental condition, we selected about 300 particles to estimate percentage of the non-spherical particles, and the percentages of non-spherical particles in the four graphs from (a) to (d) were 2.1%, 4.2%, 8.3%, and 18.6%, respectively. When the droplets left the exit, they were ovals as shown in Fig. 1b. During the process of falling, droplets shrink into a spherical shape due to surface tension, which needs a distance to occur. If h is too low, the droplet does not have enough distance and time to shrink into a ball, and particle sphericity is decreased. Furthermore, the airflow which blows to the liquid surface and then bounces back to the nozzle will also influence the outlet flow field, resulting in changes to the shape of the droplets.
Fig. 2 Optical photograph of the microparticles: (a) 1.5 wt% SA, h = 40 mm; (b) 2 wt% SA, h = 40 mm; (c) 1.5 wt% SA, h = 20 mm; and (d) 2 wt% SA, h = 20 mm. |
Comparing Fig. 2(c) with Fig. 2(d), when the solution concentration increased from 1.5 wt% to 2 wt%, the sphericity of the particles was significantly decreased at the outlet distance h of 20 mm. The SA solution concentration and the viscosity was higher and the time required for the droplets to shrink into a ball was longer, so the sphericity was significantly decreased. According to experimental results, when the concentration of sodium alginate is less than 2 wt% and distance h is more than 40 mm, then better spherical particles can be achieved. When the solution concentration increases, the required distance also increases. In order to gain spherical particles, the distance h should be kept above 40 mm.
Fig. 3 CV values and particle diameters prepared under different inlet pressures from 300, 400, and 500 μm outlet nozzles, respectively (Q = 200 μL min−1, 1.5 wt% SA, h = 40 mm). |
Changing the nozzle inlet gas pressure can lead to changes of gas flow rate at the outlet and the shear action of the continuous phase to dispersed phase, thus resulting in a change of the size of the droplet at the outlet. Before the droplet dripping, the surface tension makes them shrink into a ball and suspend at the outlet. Gravity and shear force promote droplets to drip, which has the opposite effect of surface tension.
With increasing gas velocity, the shear effect of gas to droplet also increased, causing the droplets drip early, so the droplet diameters decreased. When the gas pressure is less than 30 kPa, the pressure regulation effect is obvious and particle size decreases quickly. When the air pressure is higher than 30 kPa, a larger gas pressure increment is needed to reduce the same particle diameter. When the inlet gas pressure is low, the droplets are big and have large surface areas, so a small pressure change can provide large shear force change. When the inlet gas pressure continues to increase, droplets are easily broken by the shear force and form additional smaller droplets; then the CV value will rise rapidly. So, in our experiments we only considered conditions about CV ∼ 5%.
Fig. 4 (a) Effect of liquid flow rate on particle diameter. (b) Effect of liquid flow rate on particle CV value (1.5 wt% SA, h = 40 mm, N300, P = 20, 30, and 40 kPa). |
As can be seen from Fig. 4b, when the liquid flow increased, the CV value of the particles increased significantly. Liquids at the nozzle outlet gathered into small droplets, and it takes some time to drip. If the liquid flow rate is high, the time needed is short and the distance between two droplets is short and the interference between two droplets increases. The droplets have not enough time to shrink into a ball shape before they fall off, so CV values increase. When the flow rate is 600 μL min−1, the distance between the droplets is very short and droplets quickly are generated at the outlet. When the flow rate reaches 800 μL min−1, the liquid at the outlet nearly becomes a line. So, when the flow rate is more than 600 μL min−1, then CV values of the particles increase significantly.
Fig. 5 shows the diameters and CV values of particles prepared by different outlet diameter nozzles. By changing the inlet air pressure, particles with different diameters were obtained. As shown in the figure, when preparing the same diameter particles, a larger outlet diameter nozzle has larger CV values, and the CV values of the 300 μm nozzle are the smallest. The larger the nozzle outlet diameter is, the larger the maximum particle diameter is. Combined with Fig. 3, at the same particle diameter, the smaller nozzle outlet needed lower gas flow rate. This not only saves gas energy, but also maintains experimental stability. 300 μm, 400 μm, and 500 μm nozzles can produce the smallest droplets: about 360 μm, 397 μm, and 436 μm, respectively. If the inlet air pressure continues to increase, particle diameter change is not obvious, but CV values significantly increase.
Fig. 5 Diameters and CV values of particles prepared by N300, N400, and N500 nozzles, respectively (Q = 200 μL min−1, h = 40 mm, 1.5 wt% SA). |
The smaller diameter outlet nozzle has a smaller cross-sectional area of the liquid at the outlet, and the intermolecular viscous force is small, so the fluid is easier to be cut off by the gas. Therefore, in a follow-up study, in order to get smaller particles, we will try to print channels with smaller diameters.
According to Fig. 6(b), with an increase in sodium alginate solution concentration, the particle distribution is more nonuniform. When the solution viscosity increases, it is more difficult to separate the droplets by shear force. The minimum internal channel diameter of the nozzles is 2 mm, and the total length of the channel is 27.5 mm. Compared to the slender structure of a traditional microfluidic chip, ours has minor resistance, so it can prepare droplets with larger viscosity.
Change of solute concentration in the liquid solution will change the viscosity and density of it, which then affects size and shape of the microparticles. A higher concentration of sodium alginate solution can produce higher strength and better elastic hydrogel particles,32 which is why some scholars are hoping to improve the concentration of sodium alginate solution. However, the sodium alginate solution is a non-Newtonian fluid with shear thinning. When the concentration is greater than 1.5 wt%, the growth rate becomes significantly faster.33 A liquid–liquid shear method is usually used to prepare sodium alginate at a concentration of less than 2 wt%. If the solution concentration is too high, the continuous phase flow rate should be tens of times higher than before. This requires a high cost of continuous phase material, and even then, it is not able to successfully generate particles.
The 3D printing microfluidic nozzle in this paper has a 300 μm diameter outlet with length of only 3 mm, so it will not be blocked in the experiments. As shown in Fig. 7, at an inlet gas pressure of 20 kPa, 5 wt%, 10 wt%, and 15 wt% CaCO3 powder with diameters of 48–75 μm were directly added into 1.5 wt% sodium alginate solution to prepare composite microparticles. The obtained particles have good sphericity, and particle diameter distribution is also uniform.
Fig. 8 shows the SEM images of calcium alginate particles after being freeze-dried. Fig. 8(a) and (b) show calcium alginate microparticles without CaCO3; the internal structure of the particles is irregular. The interspace inside the particles is large and easy to break. Fig. 8(c) and (d) show calcium alginate microparticles with CaCO3; the CaCO3 microparticles are uniformly distributed inside the calcium alginate particles and around the surface. Compared with calcium alginate microparticles without CaCO3, calcium alginate microparticles with CaCO3 had uniform internal pore structures. These results are consistent with previous reports. So, the nozzle is applicable for preparing calcium alginate microparticles with other substances.
The nozzles we used were printed one at a time by 3D-printing technology. The printing time of our nozzle was less than 2 hours and the resin cost was no more than $5.37 Besides, dimensional accuracy could be easily guaranteed and repeatable. The new structure kept the two channels coaxial. As for the silicon surface micromachining method,7 its dimensional accuracy is favorable but the process needs a professional and has a high cost. For glass capillary8 assembling, needles welding,34 and tube28,35 assembling methods, the materials are cheap but the processes are quite labor consuming. Most importantly, it's hard to guarantee accuracy within a range of tens of microns by conventional manual methods. It's also difficult to guarantee that a continuous phase channel and dispersed phase channel are coaxial. This is key to the good performance of nozzles we want.
SA solution was sheared into droplets by air and directly dripped into CaCl2 solution by the nozzles method. The preparation process is simple and without any additives, so that it can prepare clean droplets with low cost. For liquid–liquid two-phase shear methods, the surfactant and oil must be added. Because of its novel structure, the nozzle could prepare calcium alginate microparticles containing 15 wt% CaCO3 powder without blocking. However, when using traditional microfluidic preparation methods the internal flow path is always long, resulting in a limitation of CaCO3 powder or SA solution concentration. The liquid–liquid shear method is usually suited to prepare sodium alginate at a concentration of less than 2 wt%.30,31
Microparticles prepared by the air-blast nozzle were uniform and had a wide diameter distribution. Diameters of microparticles could be precisely controlled by changing inlet air pressure. The 300 μm nozzle can produce particles in a diameter range from 2100 μm to 380 μm with a CV less than 5.32%. Compared to T-type, focusing microfluidics, and other methods, particles prepared by this nozzle have a significantly larger range of particle sizes. Without changing the nozzle, only changing the inlet air pressure can meet most particles production needs. Besides, when using the liquid–liquid two-phase shear method to prepare microparticles, the general flow rate can only be tens of μL min−1 (ref. 38) but the flow rate of our 300 μm diameter nozzle can reach to 800 μL min−1.
The nozzle uses gas to cut the liquid to produce droplets without adding surfactant and continuous phase or other impurities, which can thus produce clean functional particles. By controlling gas pressure, the 300 μm nozzle can prepare particles with large sizes ranging from 380 μm to 2100 μm, whose CV values are less than 5.32%. The smaller the nozzle outlet diameter is, the smaller the required inlet gas pressure and CV values are. All the parameters measured in these experiments prove that the particles prepared by this nozzle are adjustable, controllable, and uniform.