DOI:
10.1039/C7RA11487G
(Paper)
RSC Adv., 2018,
8, 3982-3988
Highly selective fluorescent carbon dots probe for mercury(II) based on thymine–mercury(II)–thymine structure†
Received
18th October 2017
, Accepted 12th January 2018
First published on 22nd January 2018
Abstract
A novel thymine-functional fluorescent sensor was developed for Hg2+ detection with high sensitivity and selectivity. The synthesis of the fluorescent sensor took two steps (1) the synthesis of amine-functionalized carbon dots (CDs-PEI); and (2) the attaching of thymine moieties on to the surface of the CDs-PEI through EDC/NHS coupling chemistry to obtain the thymine-functional fluorescence carbon dots (CDs-Thy). The CDs-Thy were successfully applied to detect Hg2+ by quenching fluorescence with a rapid response through photoinduced electron transfer with the formation of T–Hg2+–T structures. The linear concentration range of Hg2+ is 0–1.0 μmol L−1 and a limit of detection (LOD) as low as 3.5 × 10−8 mol L−1 was obtained. Moreover, the CDs-Thy can resist interference from other metal ions and anions. The CDs-Thy were also used for the Hg2+ detection in water samples and the recoveries were from 90% to 104%. Due to the simplicity and effectiveness, it shows great promise as a potential sensing platform for Hg2+.
1 Introduction
Mercury(II) is a toxic pollutant that is widely distributed in soil, water, and air.1 Metal smelting, coal production, waste disposal, refining and manufacturing, and the production of chlor-alkali processes will discharge large quantities of mercury into the environment.2–4 Inorganic mercury can be transformed into the highly toxic form such as organic methylmercury under the catalysis of microorganism. These organic mercury that can amass in human body throughout the food web2,5,6 and cause cinesipathy, disgnosia, cerebral lesion, impaired vision, and even death.7–9 For these reasons, the development of straightforward, highly sensitive and selective methods for monitoring and detecting Hg2+ is of great importance.
In recent years, fluorescent probes for Hg2+ detection have attracted extensive attention due to their convenient and time-efficient procedures,10–16 which make them good alternatives to traditional analytical techniques, such as electrochemical method,17 atomic absorption spectroscopy (AAS),18 and inductively coupled plasma mass spectrometry (ICP-MS),19,20 etc. Another alternative could be the photoluminescent carbon dots (CDs) because of their obvious advantages such as easy in preparation,21 environmental friendliness,22 good biocompatibility,23 water solubility24 and low toxicity25 by comparing with metal quantum dots and traditional organic dyes.26 They have also been applied to the analysis and detection of ions and biomolecules.21,27–32 However, in their recent status, the photoluminescent CDs showed low sensitivity and poor selectivity.33–36 Therefore, it remains a challenge to develop fluorescent CDs for highly selective and sensitive recognition of Hg2+ in biological and aqueous systems.
In this work, we developed a new kind of fluorescent CDs for Hg2+ detection. We redesigned the functional surfaces of existing photoluminescent CDs37 that had found application in Cu2+ detection38 with commendable selectivity. We found that there are amino groups on the surface of the CDs, which can be modified by thymine (T). As the thymine can form T–Hg2+–T structure (Fig. 1A),39,40 we conjectured that the newly developed thymine-functional CDs (CDs-Thy) will have high selectivity for Hg2+. The results showed that the CDs-Thy can be applied to determine the Hg2+ in water samples. Satisfactory results were obtained.
|
| Fig. 1 (A) The metal ion-mediated base pairs of T–Hg2+–T. (B) Synthetic route of CDs-Thy. (C) Schematic illustration of the CDs-Thy for Hg2+ selective recognition. | |
2 Experimental
2.1 Reagents
Citric acid (CA), 1-ethyl-3-(3-dimethylaminopropyl)carbodiimide (EDC), polyethyleneimine (PEI, M.W. 1800) and N-hydroxy-succinimide (NHS) were obtained from Aladdin (Shanghai, China). 2-(N-Morpholino)ethanesulfonic acid (MES) and thymine-1-acetic acid were purchased from Shanghai Macklin Biochemical Co. Ltd. (Shanghai, China). Hg2+ standard solution (100 μg mL−1, 5% HNO3) was purchased from Macklin Biochemical Co. Ltd. (Shanghai, China). Other cationic salts were obtained from Guangzhou Chemical Regent Factory (Guangzhou, China).
2.2 Instruments
The UV-visible absorption and the FT-IR spectra were scanned using UV 3150 UV-vis spectrometer (Shimadzu) and IR-Nicolet Avatar 330 spectrometer (Bruker), respectively. The fluorescence measurements and quantum yields were carried out by using a RF5301 spectrometer (Shimadzu). A PHS-25 pH meter (INESA Scientific Instrument Co., Ltd) was employed to determine pH values. The 1H NMR spectra were obtained by using Avance III-400 MHz spectrometer (Bruker). The transmission electron microscope (TEM) images were measured by using JEM-2010HR (Jeol Ltd). X-ray photoelectron spectroscopy (XPS) and fluorescent lifetime were recorded using an ESCALab250Xi spectroscopy (Thermo Fisher) and FLSP920 photoluminescence spectrometer (Edinburgh Instruments Ltd), respectively.
2.3 Synthesis of amine-functionalized CDs (CDs-PEI)
The CDs-PEI were prepared according to published papers elsewhere.37,38
2.4 Synthesis of thymine-functionalized CDs (CDs-Thy)
The CDs-Thy were synthesized by using excess thymine-1-acetic acid to react with the CDs-PEI. Before the modification of thymine on the CDs-PEI, the thymine-1-acetic acid (128 mg, 0.698 mmol) was activated with EDC (161 mg, 0.840 mmol) and NHS (385.4 mg, 3.35 mmol) in 140 mL MES (0.1 M, pH 5.5) solution for 20 min at 25 °C with constant stirring. Then the CDs-PEI (44.0 mg) were added into the solution and kept reacting for another 48 h (Fig. 1B). After reaction, the concentrated solution was column chromatographed on silica-gel (0.01 M HCl) to remove the by-products.
2.5 Fluorescence measurement
Stock solution of the CDs-Thy (200 μg mL−1) was prepared using deionized water. Stock solutions of cations (0.001 M) were prepared under suitable pH conditions. The pH optimization experiments of CDs-Thy in the presence and absence of Hg2+ between 5.8 and 8.2 were obtained through the fluorescence emission intensities, respectively. Real time fluorescent signals of the CDs-Thy were obtained with different concentrations of Hg2+ to optimize the optimal reaction time. All fluorescence spectra were recorded at optimized detection conditions in the PBS buffer solution (0.1 M, pH 7.4) at 25 °C.
2.6 Measurement of water samples
Tap water and Pearl River water were used for Hg2+ detection. All these samples were centrifuged and filtered with micropore membranes. The obtained filtrate was added with standard Hg2+ samples with different concentrations and used for further analysis.
3 Results and discussion
3.1 Characterization of CD-PEI and CDs-Thy
To investigate the surface modification of the CDs-Thy, FT-IR spectroscopy was used to characterize the CDs-PEI, thymine-1-acetic acid and the CDs-Thy, respectively. As shown in the spectrum a of Fig. 2A, the peaks at 3414 cm−1 (υN–H) and 1630 cm−1 (δN–H) confirmed that the surface of CDs-PEI contain amine groups. The presence of these amine groups provides CDs with the potential to be modified with the thymine-1-acetic acid consisting of –COOH group. Compared to the CDs-PEI, the CDs-Thy have the characteristic peaks in 2974 cm−1 (υ–CH3 and υ–CH2) and 1479 cm−1 (δ–CH2) as the spectrum b shown in the Fig. 2A, ascribing to vibration of –CH3 and –CH2, which can also be found at 2961 cm−1 and 1483 cm−1 in the IR spectrum of thymine-1-acetic acid as the spectrum c shown in Fig. 2A. In addition, the CDs-Thy show more peaks around 1641 cm−1 (υCO) and 1268 cm−1 (υC–N and δN–H) that are all attributed to the thymine-1-acetate groups on the surface of CDs-Thy, which also can be found in the IR spectrum of thymine-1-acetic acid at 1633 cm−1 and 1258 cm−1 as the spectrum c of Fig. 2A. These results revealed that the thymine-1-acetic group was modified on to the surface of the CDs. Moreover, with the formation of carbonyl amide, the absence of the amide-II band at 1568 cm−1 (δ–CONH–) can further prove the successful conjugation of the CDs-PEI and the thymine-1-acetic acid.
|
| Fig. 2 (A) FT-IR spectra of (a) CDs-PEI, (b) CDs-Thy and (c) thymine-1-acetic acid, respectively. (B) 1H NMR spectra of (a) the CDs-Thy (in D2O), (b) the CDs-PEI (in D2O) and (c) methyl thymine-1-acetate (in DMSO-d6), respectively. | |
Fig. 2B shows the 1H NMR spectra of the CDs-Thy, the CDs-PEI and the esterified product of thymine-1-acetic acid, respectively. In the 1H NMR spectrum of the CDs-Thy, the multiple peaks at 3.1 ppm corresponded to the resonance signals of alkyl group connected with N atoms and CO. One can also find that the chemistry shifts at 1.8 ppm, 4.4 ppm and 7.3 ppm can be attributed to the proton resonance signals of the –CH3, –CH2– and the alkene in heterocycle of the thymine functional groups, respectively. All the peaks of these protons can also be found in the 1H NMR of CDs-PEI (around 3.7 ppm in b of Fig. 2B) and methyl thymine-1-acetate (1.8 ppm, 4.4 ppm and 7.3 ppm in c of Fig. 2B). The reason to measure the 1H NMR spectrum of methyl thymine-1-acetate instead of that of thymine-1-acetic acid is that the later is not soluble in water. These results confirmed that the CDs-Thy were successfully prepared from the CDs-PEI and thymine derivative.
Fig. 3 shows the XPS spectra of CDs-PEI and CDs-Thy, respectively. Both of the XPS survey spectra of CDs-PEI (Fig. 3a) and CDs-Thy (Fig. 3b) show the peaks at 198.8 eV (Cl 2p), 269.4 eV (Cl 2s), 285.4 eV (C 1s), 400.4 eV (N 1s), and 532.1 eV (O 1s), which can be attributed to Cl 2p, Cl 2s, C 1s, N 1s, and O 1s, respectively. The detected chloride was from column chromatography processing. As shown in Fig. 3c, the C 1s XPS spectrum of the CDs-PEI can be deconvoluted into three carbon states at 284.6 eV, 286.1 eV, and 288.4 eV which are attributed to C–C/CC, C–O/C–N and O–CO, respectively.41–43 The peaks at 284.9 eV (C–C/CC), 286.0 eV (C–O/C–N), and 288.7 eV (O–CO) can be also found in the C 1s XPS spectrum of the CDs-Thy (Fig. 3d). The N 1s spectrum (Fig. 3e) of the CDs-PEI can be resolved two components which are attributed to C–NH2 at 400.2 eV and CN at 401.8 eV, respectively. However, the fitting analysis of the N 1s XPS spectrum of the CDs-Thy (Fig. 3f) reveals three distinct peaks at 399.6 eV, 400.0 eV, and 401.9 eV corresponding to OC–NH, C–N–C and CN, respectively. It means that the primary amine of CDs-PEI almost totally translate to secondary amine after the reaction with thymine-1-acetic acid. Futhermore, the O 1s XPS spectra of the CDs-PEI (Fig. 3g) and the CDs-PEI (Fig. 3h) reveal two types of oxygen bonds, which are associated with CO at 531.7 eV and C–O at 533.0 eV, respectively.44,45 And the relative contribution of CO in the CDs-Thy has an significant increase compared to the CDs-PEI, from 68.4% to 88.8%. In conclusion, the results confirm that the surfaces of the CDs-PEI were successfully functionalized with thymine groups.
|
| Fig. 3 (a) XPS survey of the CDs-PEI; (b) XPS survey of the CDs-Thy; (c) deconvoluted C 1s spectrum of CDs-PEI; (d) deconvoluted C 1s spectrum of the CDs-Thy; (e) deconvoluted N 1s spectrum of the CDs-PEI; (f) deconvoluted N 1s spectrum of the CDs-Thy; (g) deconvoluted O 1s spectrum of the CDs-PEI; (h) deconvoluted O 1s spectrum of the CDs-Thy. | |
Fig. 4A and B show the TEM results of the CDs-PEI and the CDs-Thy, respectively. It can be found that the CDs-PEI mainly consist of uniform nanoparticles in size ranging from 2 to 5 nm. The TEM showed that the average particle size of the CDs-PEI was about 3.0 nm (inset of Fig. 4A). In contrast, the particle size range and the average size of the CDs-Thy were 2–7 nm and 3.5 nm after the CDs-PEI modified with thymine group, respectively (inset of Fig. 4B). These results demonstrated that the conjugated thymine contributed about 0.5 nm to the average particle diameter.
|
| Fig. 4 (A) TEM images of CDs-PEI (inset: particle size distribution obtained from TEM image). (B) TEM images of CDs-Thy (inset: particle size distribution obtained from TEM image). (C) UV/vis absorption of CDs-PEI (0.1 mg mL−1), CDs-Thy (0.1 mg mL−1) and thymine-1-acetic acid (8.3 μg mL−1). (D) Normalized fluorescence excitation and emission spectra of CDs-PEI (35.0 μg mL−1) and CDs-Thy (33.3 μg mL−1). (E) Emission spectra of the CDs-Thy (33.3 μg mL−1) at different excitation wavelengths (300–400 nm). (F) Time decay profiles for CDs-PEI (35.0 μg mL−1) and CDs-Thy (33.3 μg mL−1) (λex: 354 nm). The line specifies the fitted curve while the scatter plots specify the experimental time decay profiles of both samples. All studies were performed in aqueous solution (0.2 M PBS buffer, pH 7.4). | |
Fig. 4C shows the UV/vis spectra of the CDs-Thy, the CDs-PEI and thymine-1-acetic acid, respectively. It can be seen that a relatively weak and broad absorption band appeared in a region from 320 to 400 nm, which was ascribed to the n–π* transition of the CO and CC conjugated structure of both CDs-PEI and CDs-Thy. The strong absorption peak around 272 nm on the spectrum of CDs-Thy proved the successful modification of thymine group on the CDs because the similar peak was also observed in the spectrum of thymine-1-acetic acid. Furthermore, the content of thymine group was measured to be 6.35 μg per 100 μg by using the standard addition experiments (Fig. S1†).
Fig. 4D shows the fluorescence excitation and emission spectra of the CDs-PEI and the CDs-Thy, respectively. When excited at 354 nm, both CDs-PEI and CDs-Thy exhibit maximum fluorescence emission around 440 nm. However, the fluorescence emission spectra of CDs-PEI and CDs-Thy have no significant difference because of their same photoluminescence mechanism. Fig. 4E shows the emission spectra of the CDs-Thy at different excitation wavelengths which varied from 300 nm to 400 nm. The emission of the CDs-Thy showed the excitation-independent property and may originated from a single species.46 Fig. 4F shows the fluorescence decay spectra of CDs-PEI and CDs-Thy. Both of the CDs-PEI and the CDs-Thy consists of a short τ1 and a long τ2 lifetime components (Table S1†). The fluorescence decay curves were fitted with a double-exponential function.47 The lifetime of CDs-Thy was 10.17 ns which was closed to the CDs-PEI (10.97 ns). Furthermore, the fluorescence quantum yields of CDs-PEI and CDs-Thy, referenced to a quinine sulfate solution in 0.1 M H2SO4 (ΦF = 0.55), were determined to be 23.6% and 31.0%, respectively (Table 1).
Table 1 Quantum yield of the fluorescent carbon dots
Sample |
I |
A |
n |
Q |
Quinine sulfate |
44016 |
0.059 |
1.33 |
54.0% |
CDs-PEI |
22827 |
0.070 |
1.33 |
23.6% |
CDs-Thy |
28685 |
0.067 |
1.33 |
31.0% |
3.2 Hg2+ sensing properties of the CDs-Thy
Experimental conditions including pH and reaction time for UV/vis and fluorescence experiments of the CDs-Thy were optimized (see Fig. S2†).
Fig. 5A shows the UV-vis spectra of the CDs-Thy in the presence of different concentrations of Hg2+. One can see that absorption peaks appeared around 307 nm, which could be attributed to the evolution of T–Hg2+–T structures. The intensities of the absorption band increased gradually with the increasing of Hg2+ concentrations. Fig. 5B shows a good linear relationship between the absorbance at 307 nm and the concentrations of Hg2+ with a correlation coefficient of R2 = 0.999.
|
| Fig. 5 (A) UV/vis spectrum of CDs-Thy (0.1 mg mL−1) in response to Hg2+ (0, 15, 20, 25, 30, 40, and 50 μM) in PBS solution (0.1 M, pH 7.4). (B) Linear regression equation of absorbance intensity at 307 nm of CDs-Thy (0.1 mg m−1) with the addition of Hg2+ (0, 15, 20, 25, 30, 40, and 50 μM) (0.1 M PBS buffer, pH 7.4). (C) Fluorescence responses of the CDs-Thy (33.3 μg mL−1) in aqueous solution upon addition of 0 μM to 50 μM Hg2+. (D) Fluorescence intensity of CDs-Thy (33.3 μg mL−1) in the presence of 0 μM to 50 μM Hg2+ (λex = 354 nm, slit: 5/5 nm). | |
Fig. 5C shows the fluorescence emission response of the CDs-Thy reacting with increased concentrations of Hg2+ from 0.1 to 50 μM. One can find that the intensity at 440 nm was continuously decreased with the addition of Hg2+.
Fig. 5D shows a very steep decrease of fluorescence intensities at 441 nm when adding Hg2+ into the solution of the CDs-Thy. Such an outstanding fluorescence quenching was assigned to the photoinduced electron transfer from the excitation state of CDs-Thy to the vacant d orbital of Hg2+ when the T–Hg2+–T structure was formed.34,36
Furthermore, the fluorescence intensity of the CDs-Thy toward Hg2+ decreased linearly over the Hg2+ concentration range of 0–1.0 μM (Fig. S3†). The limit of detection (LOD) of the CDs-Thy for Hg2+ was thus determined to be about 3.5 × 10−8 mol L−1 according to the formula: LOD = 3σ/k, where the σ means the standard deviation of the response, k means the slope of the calibration curve. Table 2 shows the comparison of linear range and limit of detection with other recently reported Hg2+ probes. The CDs-Thy provide a remarkable lower detection limits and a satisfied linear range. These results indicated that the CDs-Thy are highly sensitive for Hg2+.
Table 2 Comparison of different fluorescent sensors for Hg2+ ion detection
Fluorescent sensor |
Linear range (mol L−1) |
Limit of detection (mol L−1) |
Ref. |
N-CDs |
2.5 × 10−7–6 × 10−6 |
8 × 10−8 |
48 |
Polymer sensor |
1 × 10−6–3 × 10−5 |
7.28 × 10−7 |
49 |
N-CDs-ssDNA |
1 × 10−6–6.5 × 10−5 |
1.26 × 10−6 |
50 |
N-CDs |
0–2.5 × 10−5 |
2.6 × 10−7 |
51 |
N,S-CDs |
0–4 × 10−5 |
2 × 10−6 |
34 |
Thymine functionalized CDs |
0–1.0 × 10−6 |
3.5 × 10−8 |
This work |
Fig. 6 shows the TEMs of the solutions of the CDs-Thy with and without Hg2+, respectively. One can find that large reticular aggregates were formed when Hg2+ was introduced to the solution of CDs-Thy (Fig. 6B). The quenching of the fluorescence emission by Hg2+ could be the photoinduced electron transfer (PET) process when the T–Hg2+–T structures were formed.
|
| Fig. 6 (A) TEM image of the CDs-Thy (33.3 μg mL−1) without Hg2+. (B) TEM image of the CDs-Thy (33.3 μg mL−1) in the presence of Hg2+ (20 μM). | |
3.3 Selectivity and competition of CDs-Thy for Hg2+ detection
Fig. 7A shows the selectivity experiments of the CDs-Thy with 16 different metal cations. The fluorescence responses of the CDs-Thy were recorded in the presence of different metal cations, including Cu2+, Hg2+, Zn2+, Mg2+, Fe2+, Au3+, Co2+, Ca2+, Pb2+, Ba2+, Cr3+, Na+, Ag+, Ni2+, K+, and Fe3+. As expected, an outstanding fluorescence intensity descent was found only with the addition of Hg2+, while no noticeable changes in the fluorescence spectra were observed upon addition of other metal cations. These results demonstrated that the CDs-Thy possess a high selectivity for Hg2+ detection.
|
| Fig. 7 (A) Selectivity of CDs-Thy (33.3 μg L−1) towards Hg2+ (30 μM) and other metal ions (30 μM); (B) competitiveness of CDs-Thy (33.3 μg L−1) towards Hg2+ (30 μM) over other metal ions (50 μM); (C) selectivity of CDs-Thy (33.3 μg L−1) towards Hg2+ (30 μM) in the presence of different anions (50 μM). The fluorescence intensities at 441 nm were monitored in aqueous solution (0.2 M PBS buffer, pH 7.4) (λex = 354 nm, slit: 5/5 nm). | |
Competition measurements were also measured by adding the mixed solution of Hg2+ and other metal cations to the solution of CDs-Thy as shown in the Fig. 7B. Severe fluorescence quenching were observed when the CDs-Thy were exposed to Hg2+, which shows a superior reaction ability between the CDs-Thy and Hg2+. The fluorescence response experiments to Hg2+ of CDs-Thy in the presence of different anions including SO42−, S2−, SO32−, HCO3−, Cl−, CO32−, NO2−, S2O32−, ClO4−, NO3−, Br−, I−, ClO3− and HSO4− were also carried out as shown in the Fig. 7C. The fluorescence intensities of the CDs-Thy had no obvious change with the addition of Hg2+ even in the presence of different anions. The results indicate that the CDs-Thy exhibited high selectivity toward Hg2+.
3.4 The analysis of water samples
The CDs-Thy were applied in several tap water and river water samples to investigate the practicability of the CDs-Thy for Hg2+ sensing. Since no Hg2+ was detected in these samples, certain amount of standard Hg2+ was added to the raw water samples. The results (Table 3) shows that the recoveries ranged from 90% to 104%, and the relative standard deviations are less than 7%. These results verified that the analysis of Hg2+ using the CDs-Thy in water samples was satisfactory.
Table 3 Determination of Hg2+ ion in tap water and river water (n = 3)
Samples |
Spiked [μM] |
Found [μM] |
RSD [%] |
Recovery [%] |
Tap water |
0 |
Not detected |
— |
— |
0.50 |
0.52 |
2.26 |
104 |
0.75 |
0.77 |
0.94 |
102 |
River water |
0 |
Not detected |
— |
— |
0.50 |
0.45 |
1.10 |
90 |
0.75 |
0.75 |
1.52 |
100 |
4 Conclusions
We developed a novel thymine-functionalized carbon dots, the CDs-Thy, which can be a useful tool for selective and sensitive determination of Hg2+ in a totally aqueous solution. The CDs-Thy showed a specific on-off fluorescence response to Hg2+ based on T–Hg2+–T metal ion-mediated base pairs with a low detection limit. In addition, the CDs-Thy also had a rapid and selective response to Hg2+ at natural pH range. Moreover, the CDs-Thy also showed its ability for the measurement of Hg2+ in both tap and river water with satisfactory results. In view of these desirable features, the CDs-Thy could be a potential tool for detection and monitoring of Hg2+.
Conflicts of interest
There are no conflicts to declare.
Acknowledgements
This work was supported by the National Natural Science Foundation of China (20875106), Guangdong Natural Science Found Committee (9151027501000003), the Science and Technology Planning Project of Guangdong Province (2015A010105013), and the Science and Technology Planning Project of Guangzhou City (201607010349).
References
- N. Basu, A. Scheuhammer, N. Grochowina, K. Klenavic, D. Evans, M. O'Brien and H. M. Chan, Environ. Sci. Technol., 2005, 39, 3585–3591 CrossRef CAS PubMed.
- D. W. Boening, Chemosphere, 2000, 40, 1335–1351 CrossRef CAS PubMed.
- P. Li, X. B. Feng, G. L. Qiu, L. H. Shang and Z. G. Li, J. Hazard. Mater., 2009, 168, 591–601 CrossRef CAS PubMed.
- A. Gupta, A. Chaudhary, P. Mehta, C. Dwivedi, S. Khan, N. C. Verma and C. K. Nandi, Chem. Commun., 2015, 51, 10750–10753 RSC.
- T. W. Clarkson, Environ. Health Perspect., 2002, 110, 11–23 CrossRef CAS PubMed.
- T. W. Clarkson, L. Magos and G. J. Myers, N. Engl. J. Med., 2003, 349, 1731–1737 CrossRef CAS PubMed.
- P. Grandjean, P. Weihe, R. F. White and F. Debes, Environ. Res., 1998, 77, 165–172 CrossRef CAS PubMed.
- J. K. Virtanen, T. H. Rissanen, S. Voutilainen and T. P. Tuomainen, J. Nutr. Biochem., 2007, 18, 75–85 CrossRef CAS PubMed.
- E. M. Nolan and S. J. Lippard, Chem. Rev., 2008, 108, 3443–3480 CrossRef CAS PubMed.
- Y. K. Yang, K. J. Yook, J. Tae, K. Jeong and Y. J. Tae, J. Am. Chem. Soc., 2005, 127, 16760–16761 CrossRef CAS PubMed.
- B.-C. Ye and B.-C. Yin, Angew. Chem., Int. Ed., 2008, 47, 8386–8389 CrossRef CAS PubMed.
- N. Wang, M. Lin, H. Dai and H. Ma, Biosens. Bioelectron., 2016, 79, 320–326 CrossRef CAS PubMed.
- K. P. Carter, A. M. Young and A. E. Palmer, Chem. Rev., 2014, 114, 4564–4601 CrossRef CAS PubMed.
- Y. Wang, F. Pan, Y. Zhang, F. Peng, Z. Huang, W. Zhang and W. Zhao, Analyst, 2016, 141, 4789–4795 RSC.
- S. Lu, D. Wu, G. Li, Z. Lv, Z. Chen, L. Chen, G. Chen, L. Xia, J. You and Y. Wu, RSC Adv., 2016, 6, 103169–103177 RSC.
- P. Kaewanan, P. Sricharoen, N. Limchoowong, T. Sripakdee, P. Nuengmatcha and S. Chanthai, RSC Adv., 2017, 7, 48058–48067 RSC.
- V. Jovanovski, N. I. Hrastnik and S. B. Hočevar, Electrochem. Commun., 2015, 57, 1–4 CrossRef CAS.
- M. Ghaedi, M. R. Fathi, A. Shokrollahi and F. Shajarat, Anal. Lett., 2006, 39, 1171–1185 CrossRef CAS.
- J. Allibone, E. Fatemian and P. J. Walker, J. Anal. At. Spectrom., 1999, 14, 235–239 RSC.
- D. E. Nixon, M. F. Burritt and T. P. Moyer, J. Anal. Toxicol., 2007, 31, 281–287 CrossRef.
- A. Zhao, Z. Chen, C. Zhao, N. Gao, J. Ren and X. Qu, Carbon, 2014, 85, 309–327 CrossRef.
- S. N. Baker and G. a. Baker, Angew. Chem., Int. Ed., 2010, 49, 6726–6744 CrossRef CAS PubMed.
- Y. Dong, J. Cai, X. You and Y. Chi, Analyst, 2015, 140, 7468–7486 RSC.
- S. Qu, X. Wang, Q. Lu, X. Liu and L. Wang, Angew. Chem., 2012, 124, 12381–12384 CrossRef.
- M. Havrdova, K. Hola, J. Skopalik, K. Tomankova, M. Petr, K. Cepe, K. Polakova, J. Tucek, A. B. Bourlinos and R. Zboril, Carbon, 2016, 99, 238–248 CrossRef CAS.
- A. Xiao, C. Wang, J. Chen, R. Guo, Z. Yan and J. Chen, Ecotoxicol. Environ. Saf., 2016, 133, 211–217 CrossRef CAS PubMed.
- F. R. Baptista, S. A. Belhout, S. Giordani and S. J. Quinn, Chem. Soc. Rev., 2015, 44, 4433–4453 RSC.
- Y. Guo, L. Zhang, S. Zhang, Y. Yang, X. Chen and M. Zhang, Biosens. Bioelectron., 2015, 63, 61–71 CrossRef CAS PubMed.
- P. Li, X.-Y. Sun, J.-S. Shen and B. Liu, RSC Adv., 2016, 6, 61891–61896 RSC.
- S. Liu, R. Liu, X. Xing, C. Yang, Y. Xu and D. Wu, RSC Adv., 2016, 6, 31884–31888 RSC.
- Q. Li, Q. Huang, J.-J. Zhu, W.-G. Ji and Q.-X. Tong, RSC Adv., 2016, 6, 87230–87236 RSC.
- C. Wang, D. Sun, Y. Chen and K. Zhuo, RSC Adv., 2016, 6, 86436–86442 RSC.
- J. Yu, N. Song, Y.-K. Zhang, S.-X. Zhong, A.-J. Wang and J. Chen, Sens. Actuators, B, 2015, 214, 29–35 CrossRef CAS.
- L. Li, B. Yu and T. You, Biosens. Bioelectron., 2015, 74, 263–269 CrossRef CAS PubMed.
- Y. Wang, S.-H. Kim and L. Feng, Anal. Chim. Acta, 2015, 890, 134–142 CrossRef CAS PubMed.
- J. He, H. Zhang, J. Zou, Y. Liu, J. Zhuang, Y. Xiao and B. Lei, Biosens. Bioelectron., 2016, 79, 531–535 CrossRef CAS PubMed.
- Y. Dong, R. Wang, H. Li, J. Shao, Y. Chi, X. Lin and G. Chen, Carbon, 2012, 50, 2810–2815 CrossRef CAS.
- Y. Dong, R. Wang, G. Li, C. Chen, Y. Chi and G. Chen, Anal. Chem., 2012, 84, 6220–6224 CrossRef CAS PubMed.
- A. Ono and H. Togashi, Angew. Chem., Int. Ed., 2004, 43, 4300–4302 CrossRef CAS PubMed.
- L. Li, Y. Wen, L. Xu, Q. Xu, S. Song, X. Zuo, J. Yan, W. Zhang and G. Liu, Biosens. Bioelectron., 2016, 75, 433–445 CrossRef CAS PubMed.
- B. Chen, F. Li, S. Li, W. Weng, H. Guo, T. Guo, X. Zhang, Y. Chen, T. Huang and X. Hong, et al., Nanoscale, 2013, 5, 1967 RSC.
- S. Lu, G. Xiao, L. Sui, T. Feng, X. Yong, S. Zhu, B. Li, Z. Liu, B. Zou and M. Jin, Angew. Chem., Int. Ed., 2017, 56, 6187–6191 CrossRef CAS PubMed.
- Q. Huang, L. Zou and D. Chen, RSC Adv., 2016, 6, 82294–82297 RSC.
- Z. Yang, M. Xu, Y. Liu, F. He, F. Gao, Y. Su, H. Wei and Y. Zhang, Nanoscale, 2014, 6, 1890–1895 RSC.
- J. Hou, J. Li, J. Sun, S. Ai and M. Wang, RSC Adv., 2014, 4, 37342 RSC.
- D. Qu, M. Zheng, L. Zhang, H. Zhao, Z. Xie, X. Jing, R. E. Haddad, H. Fan and Z. Sun, Sci. Rep., 2014, 4, 1–9 Search PubMed.
- Y. Zhang, P. Cui, F. Zhang, X. Feng, Y. Wang, Y. Yang and X. Liu, Talanta, 2016, 152, 288–300 CrossRef CAS PubMed.
- L. Wang, B. Li, F. Xu, X. Shi, D. Feng, D. Wei, Y. Li, Y. Feng, Y. Wang and D. Jia, et al., Biosens. Bioelectron., 2016, 79, 1–8 CrossRef CAS PubMed.
- J. Li, Y. Wu, F. Song, G. Wei, Y. Cheng and C. Zhu, J. Mater. Chem., 2012, 22, 478–482 RSC.
- Z. Li, Y. Ni and S. Kokot, Biosens. Bioelectron., 2015, 74, 91–97 CrossRef CAS PubMed.
- R. Zhang and W. Chen, Biosens. Bioelectron., 2014, 55, 83–90 CrossRef CAS PubMed.
Footnote |
† Electronic supplementary information (ESI) available: Standard curve to calculate the modification amounts of thymine derivative (Fig. S1). Conditions optimization of pH and reaction time (Fig. S2). Linear plots of the fluorescence intensities of CDs-Thy with the addition of Hg2+ (Fig. S3). See DOI: 10.1039/c7ra11487g |
|
This journal is © The Royal Society of Chemistry 2018 |
Click here to see how this site uses Cookies. View our privacy policy here.