DOI:
10.1039/C8RA01805G
(Paper)
RSC Adv., 2018,
8, 15087-15093
Efficient removal of hexavalent chromium from water by an adsorption–reduction mechanism with sandwiched nanocomposites†
Received
1st March 2018
, Accepted 13th April 2018
First published on 23rd April 2018
Abstract
Hexavalent chromium Cr(VI), one of the most toxic contaminants, is released in the environment due to various anthropogenic activities. This study presents a novel sandwiched nanocomposite synthesized using graphene oxide (GO), manganese dioxide (MnO2) nanowires, iron oxide (Fe3O4) nanoparticles and polypyrrole (PPy) to remove hexavalent chromium ion Cr(VI) from water by an adsorption–reduction mechanism. In the sandwiched nanocomposites, GO provided enough surface area, functional groups, and hydrophilic surface for efficient absorption. Fe3O4 nanoparticles with excellent magnetic properties make it easy to separate and recover from water. Under acidic conditions, MnO2 nanowires act as both template and oxidant to initiate the polymerization of pyrrole monomers on its freshly activated surface to obtain GO/MnO2/Fe3O4/PPy (designated as GMFP) nanocomposite. GMFP could effectively adsorb Cr(VI) through electrostatic attraction, and the adsorbed Cr(VI) ions were partly reduced to trivalent chromium Cr(III) (62%), resulting in the efficient adsorption and high removal of Cr(VI) from water. Hexavalent chromium adsorption by GMFP is strongly pH dependent and the adsorption kinetics followed the pseudo-second-order model. The Langmuir isothermal model described the adsorption isotherm data well and the maximum adsorption capacity was up to 374.53 mg g−1 at pH 2.0. These experimental results suggested that GMFP had great potential as an economic and efficient adsorbent of hexavalent chromium from wastewater, which has huge application potential.
1. Introduction
The existence of heavy metal ions, such as Pb(II), Fe(III), Hg(II), Cu(II) and Cr(VI) in groundwater is one of the most serious environmental problems today.1,2 These toxic contaminants are a serious danger to human health. They enter the ecosystem through industrial and agricultural processes as well as mining activities.3,4 Among the toxic metal ions, chromium is a common contaminant in the environment coming from various anthropogenic activities, including metal electroplating, steelworks manufacturing, leather tanning, synthesis of pigments and so on. It is found that chromium exists in the environment in two stable states: trivalent Cr(III) and hexavalent Cr(VI), and the toxicity of the hexavalent form is five hundred times greater than that of the trivalent form.5 Cr(VI) can cause many health problems, such as liver damage, pulmonary congestion, asthma, and severe diarrhea.1,5 Therefore, various agencies such as WHO and USEPA have given a tolerable limit of 0.05 mg L−1 for dissolved Cr(VI) in drinking water, and that for total chromium (all form of chromium) is 2 mg L−1.6 Therefore, it is very urgent to remove Cr(VI) from wastewater or reduce Cr(VI) to less toxic Cr(III) prior to discharge into the environment. Until now, several methods have been reported to reduce the harmful effects of Cr(VI) such as electrical enrichment, reverse osmosis, ion exchange and adsorption.7–10 Owing to the simple procedure, cost-effective, and high efficiency, adsorption methods have great potential for the removal of Cr(VI) and thus attracting more and more attention in recent years.11
Different types of adsorbent materials have been widely used for the removal of Cr(VI) from wastewater. However, conventional adsorbents often show a limited adsorption capacity or not easily separated even cause potential secondary pollution because they do not have enough surface area, functional groups, and hydrophilic surface.12 Therefore, it is important to fabricate a nanomaterials with excellent performances of adsorption, reduction, and collectability simultaneously for the removal of Cr(VI) from wastewater.
Among the various materials, graphene oxide (GO), a two-dimensional carbon nanomaterial, has been used as a highly efficient adsorbent to remove heavy metal ions because of having an ultralarge specific surface area and abundant oxygen-containing groups (e.g. –OH and –COOH).13–16 And the idea of GO coated with MnO2 may be utilized in synthesizing new nanocomposite materials which would have better performances in metal ions adsorption applications. Polypyrrole (PPy) carries large amounts of positively charged nitrogen atoms in the polymer chains, which render it a good prospect in adsorption application.17–19 Although GO/MnO2/PPy has high adsorption and reduction abilities for Cr(VI), the resulting mixture could not be easily collected from water after treatment towards Cr(VI).20 Herein, Fe3O4 was incorporated with GO/MnO2/PPy to obtain GO/MnO2/Fe3O4/PPy, which displayed a high removal ability on Cr(VI) through adsorption and reduction, and an excellent magnetic collectability from aqueous solution. The optimal condition and the removal mechanism were investigated. This work provides a facile, efficient, and environmentally-friendly approach for the remediation of Cr(VI)-contaminated wastewater.
2. Results and discussion
2.1. Characterization
Aim to design materials with high adsorption capacity for the chromium removal, a sandwiched nanocomposite has been developed with utilizing graphene oxide (GO), manganese dioxide (MnO2) nanowires, iron oxide (Fe3O4) nanoparticles and polypyrrole (PPy), as illustrated in Scheme 1. In this study, we employed GO as the substrate for its ultralarge specific surface area and abundant oxygen-containing groups. By means of hydrothermal method, the MnO2 nanowires were deposited at the surface of graphene oxide sheets. Fe3O4 was incorporated with GO/MnO2 to obtain GO/MnO2/Fe3O4, which displayed an excellent magnetic collectability as adsorbent for Cr(VI) remove from aqueous solution. Finally, by using pre-prepared MnO2 nanowires as the reactive templates, pyrrole monomers transport to the surface of MnO2 nanowires, leading to the formation of GO/MnO2/Fe3O4/PPy, which displayed a high removal ability on Cr(VI) through adsorption and reduction.
|
| Scheme 1 Schematic illustration of the formation mechanism of (A) GO/MnO2, (B) GO/MnO2/Fe3O4, (C) GO/MnO2/Fe3O4/PPy. | |
The obtained GMFP nanocomposite was first characterized by scanning electron microscopy (SEM) (Fig. 1). GO was prepared by modified Hummers method from natural flake graphite (Fig. 1A). Then GO/MnO2 nanomaterials were fabricated via hydro-thermal method. As shown in Fig. 1B, the MnO2 component in the composite is nanowire, which is several hundred nanometers to several micrometers in length and homo-geneously and densely attached on the surface of graphene sheets. Fig. 1C is the GO/MnO2/Fe3O4 nanocomposites, in which the Fe3O4 nanoparticles were well distributed on the surface of GO/MnO2 nanocomposites. After functionalized with pyrrole, as displayed in Fig. 1D, the resulting sample has rough surface. MnO2 is a strong oxidant and acts as chemical oxidative initiator for pyrrole polymerization. Since the MnO2 serves as oxidant and template in the chemical reaction, PPy shell is coated on MnO2 nanowires to form core–shell structure.
|
| Fig. 1 SEM images of (A) GO, (B) GO/MnO2, (C) GO/MnO2/Fe3O4, and (D) GMFP nanocomposites. | |
The formation mechanism of MnO2/PPy coaxial nanowires is illustrated in Scheme 2. It is understandable that the core of the coaxial nanowires is α-MnO2 and the shell is PPy. In our case, the α-MnO2 nanowire surface exposed in acidic solution contacts with pyrrole monomers to proceed with a redox reaction. When H+ ions are added in the solution, some of them are adsorbed on the surface of α-MnO2 nanowires due to the electrostatic attraction. After adding pyrrole, the monomers transport to the surface of α-MnO2 nanowires because of their intrinsic hydrophilic characteristic in acid solution and polymerize over there, leading to the formation of PPy shell. Fig. 2 shows the TEM images of α-MnO2 nanowires and MnO2/PPy coaxial nanowires. As shown in Fig. 2A, the MnO2 sample demonstrates 1-D nanostructured crystals, no other morphologies are observed in the sample. TEM image in Fig. 2C further confirms the formation of MnO2 nanowires with average thickness of 22.52 nm and average length of several microns. Fig. 2B shows the TEM images of MnO2/PPy coaxial nanowires, the average thickness of the MnO2/PPy coaxial nanowires was 49.38 nm. So the average thickness has changed greatly before and after the treatment of PPy. TEM image in Fig. 2D clearly reveals the core/shell morphology of the MnO2/PPy nanowires with the outer layer of PPy with thickness about 5–10 nm and the inner layer of MnO2 nanowires with the wall thinned, confirming the successful preparation of MnO2/PPy coaxial nanowires. The image of size distribution was shown in Fig. S1.†
|
| Scheme 2 Schematic illustration of the formation mechanism of the MnO2/PPy nanocomposites in acid condition. | |
|
| Fig. 2 TEM images of (A) and (C) MnO2, (B) and (D) MnO2/PPy. | |
The crystal structure of the GMFP nanocomposite has been identified by X-ray power diffraction measurement. It can be clearly seen that diffraction peaks located at 2θ = 12.8, 18.1, 28.7, 36.5, 37.5, 42.0, 49.8, 56.1, 60.1, 65.6 and 69.5°, which can be assigned to the (110), (200), (310), (400), (211), (301), (411), (600), (521), (002) and (541) planes of α-MnO2 (JCPDS no. 44-0141) (Fig. 3a).21,22 No characteristic impurity peaks are observed, indicating the high purity of α-MnO2 nanowires. And seen from the XRD pattern of the MnO2/PPy in Fig. 3b, all diffraction peaks are similar to the pristine α-MnO2, confirming the presence of α-MnO2 in the composites after in situ polymerization. As shown in Fig. 3d, the diffraction peaks (2θ = 30.3°, 35.62°, 43.3°, 53.34°, 57.16°, and 62.76°) of Fe3O4 (JCPDS no. 75-0033) appeared in the XRD pattern of GMFP, suggesting that Fe3O4 was successfully combined with GO/MnO2.23
|
| Fig. 3 X-ray diffraction patterns of (a) MnO2, (b) MnO2/PPy, (c) GO/MnO2, (d) GMFP. | |
The structural information and chemical component of are also identified by the FT-IR spectroscopy. For comparison, the spectra for both α-MnO2 and MnO2/PPy coaxial nanowires are recorded and shown in Fig. 4. It can be seen that from Fig. 4a, the characteristic peaks of α-MnO2 appear at about 721, 531 and 475 cm−1, belonging to Mn–O vibrations of MnO6 octahedra in α-MnO2 nanowires, and at 1635 cm−1, relating to O–H vibrational mode of absorbed water. By contrast, in the spectrum of MnO2/PPy coaxial nanowires (Fig. 4b), the aforesaid peaks at 531 and 475 cm−1 shift to 527 and 469 cm−1, respectively, and all display attenuation in intensity, reflecting a mutual interaction between PPy and MnO2 that, most likely, is a hydrogen bond formed between oxygen atom of Mn–O and hydrogen atom of N–H in PPy.24 Such spectral information suggests that the PPy shell has been coated closely on MnO2 surface and in doping state. In Fig. 4c and a characteristic peak at 586 cm−1 for the Fe–O stretching vibration of Fe3O4 appeared. While the transmissions around 1626 and 874 cm−1 in Fig. 4c from the amine-functionalized nanocrystals matched well with that from free 1,6-hexa-diamine, indicating the existence of the free –NH2 group on the amine-functionalized Fe3O4 nano-materials.
|
| Fig. 4 FT-IR spectra of (a) MnO2, (b) MnO2/PPy, (c) GMFP nanocomposites. | |
2.2. Determination of Cr6+ concentration
The concentration of Cr6+ was analyzed by UV spectro-photometric method,25 and the results were shown in Fig. S2 and S3 (ESI†). When absorbance is plotted against concentration, the data are regressed linearly, so we could calculate concentration of hexavalent chromium ion from the absorbance.
2.3. Effect of solution pH
The solution pH has been acknowledged as the most important factor governing metal adsorption onto the adsorbent.26 To investigate the adsorption capacity of GMFP under both acidic and alkalic conditions, pH values from 2 to 12 at initial concentrations of 300 mg L−1 to evaluate the effect of pH on the Cr6+ adsorption process.
Solution pH affects both the surface charge of an adsorbent and the speciation of metal ions. The effect of initial solution pH on Cr(VI) adsorption by the GMFP composite was therefore studied and illustrated in Fig. 5. As shown in Fig. 5A, the Cr(VI) adsorption capacity decreased as the solution pH increasing from 2 to 12. Cr(VI) speciation in solution is known to be highly pH dependent (Fig. 5B). Chromic acid (H2CrO4) occurs when pH is less than 1. Furthermore, from acidic pH 1 to the neutral pH 7, the hydrogen chromate ion (HCrO4−) exist, whereas, above the neutral pH, only chromate ions (CrO42−) exist in the solution.27,28 At a lower pH, the adsorption effect is high because predominant Cr6+ species mainly exists in monovalent HCrO4− form, which is then gradually converted to divalent CrO42− and Cr2O72− as pH increases. The adsorption free energy of HCrO4− is lower than that of CrO42− and Cr2O72−; and consequently, HCrO4− is more favorably adsorbed than CrO42− and Cr2O72− at the same concentration. As the pH increases, the GMFP nanocomposites surface becomes increasingly deprotonated so that the amount of positive surface charges is significantly decreased, leading to a reduction in the adsorption capacity of Cr6+. Thus, the adsorption quantities of Cr6+ at a lower pH are larger than that of at higher pH. The controlled experiments about without use of adsorbent in the presence of acid and without acid only use adsorbent have been made. The result was shown in Fig. S4.† The figure shows that the concentration of Cr(VI) does not change without use of adsorbent in the presence of acid (pH = 2), and the Cr(VI) percentage removal is about 26% without acid only use the adsorbent. This result shows that the pH value is an important factor affecting the adsorption efficiency.
|
| Fig. 5 (A) Effect of pH on the adsorption of Cr(VI) by GMFP: temperature, 298.15 K; adsorption time, 6 h; and initial Cr(VI) concentration, 300 mg L−1, (B) relative distribution of Cr(VI) species in water as a function of pH and Cr(VI) concentration (adapted from ref. 1). | |
2.4. Adsorption isotherms
Batch equilibrium adsorption experiments were used for adsorption assessment through plots of adsorption isotherms. The maximum adsorption capacity can be obtained from adsorption isotherms. Adsorption isotherm consists of two important parameters, Langmuir and Freundlich isotherms.
Langmuir adsorption isotherms have been successfully applied to many real adsorption processes. A basic assumption of Langmuir theory is that adsorption takes place at specific homogeneous sites within the adsorbent. It is assumed that once a molecule occupies a site, no further adsorption can occur at that site. Theoretically, a saturation value is reached and no further sorption can occur. A linear form of this expression is:
where
qe (mg g
−1) is the amount of solution adsorbed per unit mass of the adsorbent,
Ce (mg L
−1) is the solute equilibrium concentration,
qm (mg g
−1) is the maximum adsorbate amount that forms a complete monolayer on the surface, and
b (L mg
−1) is the Langmuir constant related to adsorption heat. When
Ce/
qe is plotted against
Ce and the data are regressed linearly, the
qm and
b constants can be calculated from the slope and the intercept.
The values of these parameters, as analyzed from the plots shown in Fig. 6, are summarized in Table 1. According to the obtained results, the adsorption data of the Cr(VI) ions of GMFP nanocomposites were fitted particularly well with the Langmuir model, with good correlation coefficients. The maximal adsorption capacity of Cr(VI) ions of GMFP nano-composites was about 374.53 mg g−1. By comparison to the reported adsorbents (Table 2), GMFP has a superb removal capacity toward Cr(VI). Therefore, GMFP is a potential material for Cr-contaminated wastewater cleanup.
|
| Fig. 6 Fit of equilibrium data to Langmuir isotherm model. | |
Table 1 Parameters of the Langmuir isotherms for Cr6+ adsorption onto GMFP nanocomposites
pH |
T (K) |
qm (mg g−1) |
b |
R2 |
2 |
308.5 |
374.53 |
0.320 |
0.995 |
Table 2 Comparison of maximum adsorption capacity of Cr(VI) on GMFP with other adsorbents
Absorbent |
Qm (mg g−1) |
Optimum pH |
Ref. |
Graphene oxide |
65.2 |
2 |
29 |
GO/MnO2/Fe3O4 |
193.1 |
2 |
5 |
MnO2/Fe3O4/o-MWCNTs |
186.9 |
2 |
30 |
PPy nanoclusters |
180.4 |
5 |
31 |
PPy/Fe3O4 |
169.4 |
2 |
32 |
PPy/o-MWCNTs |
294.1 |
2 |
33 |
PPy/2,5-Diaminobenzene |
222.2 |
2 |
34 |
PPy/sepiolite nanofibers |
302 |
2 |
35 |
GO/MnO2/Fe3O4/PPy |
374.5 |
2 |
This study |
2.5. Adsorption kinetics
Adsorption kinetics, demonstrating the solute uptake rate, is one of the most important factors which represent the adsorption efficiency of the GMFP and therefore, determines their potential applications. The effect of adsorption time on the adsorption capacity at different initial solution concentrations is shown in Fig. 7A. The removal of Cr6+ increases with increasing contact time. To better understand the adsorption behaviors, the kinetic adsorption data were simulated with the pseudo-second-order rate equation, which are expressed as follows:
where qe and qt (mg g−1) are the adsorption capacities at equilibrium and at time t (min), k2 (g mg−1 min−1) are the pseudo-second-order rate adsorption constants.
|
| Fig. 7 (A) The adsorption capacity of GMFP nano-composites for different concentrations of Cr(VI) ions with time. (B) The pseudo-second-order model for adsorption of Cr(VI) ions by GMFP nanocomposites. | |
The values of these parameters, as analyzed from the plots shown in Fig. 7, are summarized in Table 3. It is found that the removal of Cr6+ increases with increasing contact time. The equilibrium capacity qe calculated from the pseudo-second-order kinetic model were 261.78, 316.45, 350.87 and 364.96 mg g−1 for the 150, 200, 250 and 300 mg L−1 initial Cr6+ solution. The rate constants (k2) were very small, suggesting that the adsorption process was not very fast. Fig. 7B and Table 3 show the pseudo-second-order model for adsorption of Cr(VI) by GMFP nanocomposites. From the plots t/qt vs. T of GMFP nanocomposites adsorbent at initial concentrations of Cr(VI) varied from 150 to 300 mg L−1, the pseudo-second-order rate constant (k2) decreases from 9.588 × 10−5 to 7.396 × 10−5 g mg−1 min−1. The calculated qe is also close to the theoretical one, and the correlation coefficient (R2) is above 0.994. This result indicates that the adsorption kinetics of the Cr(VI) removal by the GMFP nanocomposites follows the pseudo-second-order model, suggesting it is a chemisorption process.
Table 3 Kinetics parameters for Cr(VI) adsorption onto GMFP nanocomposites with different concentrations
Concentration of Cr(VI) ions (mg L−1) |
qe (mg g−1) |
k2 (g mg−1 min−1) |
R2 |
150 |
261.78 |
9.588 × 10−5 |
0.9943 |
200 |
316.45 |
7.856 × 10−5 |
0.9941 |
250 |
350.87 |
7.454 × 10−5 |
0.9936 |
300 |
364.96 |
7.396 × 10−5 |
0.9955 |
2.6. Mechanisms of adsorption
We also use the XPS spectra to investigate the mechanism of Cr(VI) adsorption with the GMFP nanomaterials in current system (see Fig. S5†). The presence of the elements C, N, O, Mn and Fe with high contents in the GMFP was evidenced by the photoelectron lines of the wide-scan XPS spectrum at 285, 401, 532, 641 and 711 eV, attributed to C 1s, N 1s, O 1s, Mn 2p and Fe 2p, respectively (Fig. S5A†). The Mn 2p XPS spectrum exhibits two characteristic peaks at 642.0 and 653.5 eV, corresponding to the Mn 2p3/2 and Mn 2p1/2 spin–orbit peaks of α-MnO2, further confirming the presence of α-MnO2 in the composite (Fig. S5B†). In the high-resolution Fe 2p XPS spectrum (Fig. S5C†), the peaks of Fe 2p3/2 and Fe 2p1/2 at 710.6 and 724.1 eV were the characteristic positions of Fe3O4,36 indicating the existence of Fe3O4 nanoparticles in the MnO2 support. In the formation process of the GMFP nanocomposites, the initial GO was reduced to graphene, confirmed by significantly improving the intensity of sp2 C–C bonds of graphene and decreasing the oxygen containing carbon (epoxy C–O, carbonyl CO, and carboxyl) (Fig. S5D†). XPS spectra of the GMFP nanocomposites before and after adsorption of Cr(VI) were shown in Fig. S5E.† Before adsorption of Cr(VI), no Cr ions signals are observed in the XPS spectrum of GMFP. However, two energy bands at about 577.3 and 586.8 eV appear after adsorption of Cr(VI), corresponding to the binding energies of Cr 2p3/2 and Cr 2p1/2. This observation suggests the existence of both Cr(III) and Cr(VI) on the surface of the GMFP after their adsorption of Cr(VI). The existence of Cr(VI) species on the surface of GMFP can be attributed to the adsorption of Cr(VI) ions through the anion exchange property of the surface of GMFP under acidic conditions. However, the appearance of Cr(III) on the surface of GMFP indicates that some fraction of adsorbed Cr(VI) was reduced to Cr(III) during the adsorption process. After treatment of Cr(VI), the N 1s peak of GMFP shifted to a lower binding energy (Fig. S5F†), and the peak width of N 1s decreased significantly, suggesting that the presence of positive nitrogen group in polypyrrole was regarded as a great contribution to the reduction process.37,38 There could be a possibility of reduction of Cr(VI) to Cr(III) in the presence of functional groups such as –OH, –COOH, and –NH–, on the surface of GMFP at low pH values due the occurrence of redox reactions between the surface groups and the Cr(VI). The whole process was represented by the following eqn and Scheme 3: |
GMFP + Cr2O72− + H+ → Cr3+ + HCrO4− + H2O
| (1) |
|
HCrO4− + 7H+ + 3e → Cr3+ + 4H2O
| (2) |
|
| Scheme 3 Schemes illustrations of mechanism on the removal of Cr(VI). | |
2.7. Desorption performance of the GMFP
For practical application, recycling and regeneration of the adsorbent is indispensable because the better repeated availability of advanced adsorbents may reduce the overall cost of the adsorbent. Given that the adsorption of Cr6+ ions onto the GMFP is pH-dependent and that the lower pH is beneficial for the Cr6+ adsorption, the desorption of Cr6+ ions from the adsorbent can be achieved by increasing the system pH values. Therefore, for the reusability study, experiments were conducted at alkaline condition. It can be seen that the GMFP nanocomposite still possessed more than 282 mg g−1 of the adsorption capacities for Cr6+ after four cycles of reuse, indicating that GMFP have a good reusability for Cr6+ adsorption, which slightly decreased to 264 mg g−1 at the fifth cycle, reflecting the high adsorption and stability of GMFP (Fig. S4†).
2.8. Effect of co-existing ions
Chromium-containing industrial wastewater also contains other types of particles, such as Cu2+, Zn2+, Ni2+, Cl−, CO32− and SO42−. Therefore, it is essential to investigate the competitive influence of these co-existing ions on Cr(VI) removal and the results are presented in Fig. 8. Initially Cr(VI) removal was recorded using 50 mL of 200 mg L−1 of Cr(VI) solution and 30 mg of GMFP. The figure shows that both anions and cations in solution at varying concentrations do not significantly affect the removal of Cr(VI) by GMFP. These results can be explained by the surface properties of GMFP. At low pH, cations in solution are repelled from the positively charged surface of GMFP, and therefore, do not affect Cr(VI) removal. Anions such as Cl−, CO32− and SO42− are expected to compete with Cr(VI) because they are negatively charged (HCrO4−). But it is not observed as seen from Fig. 8. One possible reason is that Cl−, CO32− and SO42− are weaker oxidising agents than HCrO4−, they are not reduced by GMFP and therefore do not affect Cr(VI) adsorption.33
|
| Fig. 8 Effect of co-existing ions on the removal of Cr(VI) by GMFP. | |
3. Conclusion
Hexavalent chromium is one of the extremely toxic heavy metals of great concern in water supplies. Until now, different types of adsorbent materials have been widely studied for the removal of Cr(VI) from wastewater. However, conventional adsorbents often show a limited adsorption capacity or difficult to collected from wastewater, these shortages limit these materials in actual application. For conducting polymers, polypyrrole (PPy) has been studied for the removal of Cr(VI) from wastewater because of its tunable morphology, excellent redox property and long-term environment stability. In this study, we present a magnetic nanocomposite named GMFP, was fabricated based on GO, MnO2, Fe3O4 and PPy, and it was confirmed by SEM, TEM, XRD, and FTIR. The MnO2/PPy composites with core/shell nanostructure were synthesized successfully via a simple approach, and performed excellently towards Cr(VI) adsorption in the aqueous solution, displaying high adsorption capacity (374.53 mg g−1) under acidic conditions. The results of XPS shows the mechanisms of Cr removal, its suggested the adsorption effect was mainly because of the electrostatic attraction between the surface of the bare GMFP and Cr(VI), and the reduction from Cr(VI) to Cr(III) was mainly attributed to the functional groups (such as –OH, –COOH, and –NH–) of GMFP. This finding implicated that GMFP had great potential as an economical and efficient adsorbent of Cr(VI) from wastewater.
Conflicts of interest
There are no conflicts to declare.
Acknowledgements
This work was supported by the National Basic Research Program of China (2015CB932002), China-Singapore Joint Project (2015DFG92510), Science and Technology Service Network Initiative of Chinese Academy of China (KFJ-SW-STS-172), and National Natural Science Foundation of China (No. 21371174, 21671052, 21375131 and 21475135).
Notes and references
- M. K. Dinker and P. S. Kulkarni, J. Chem. Eng. Data, 2015, 60, 2521–2540 CrossRef CAS.
- F. Fu and Q. Wang, J. Environ. Manage., 2011, 92, 407–418 CrossRef CAS PubMed.
- Y. Sun, Q. Yue, Y. Mao, B. Gao and Y. Gao, J. Hazard. Mater., 2014, 265, 191–200 CrossRef CAS PubMed.
- X. Li, L. Ai and J. Jiang, Chem. Eng. J., 2016, 288, 789–797 CrossRef CAS.
- Y. Liu, C. Luo, G. Cui and S. Yan, RSC Adv., 2015, 5, 54156–54164 RSC.
- A. Zhitkovich, Chem. Res. Toxicol., 2011, 24, 1617–1629 CrossRef CAS PubMed.
- V. Lugo-Lugo and B. Bilyeu, J. Hazard. Mater., 2012, 223, 1–12 Search PubMed.
- Y. Xing, X. Chen and D. Wang, Environ. Sci. Technol., 2007, 41, 1439–1443 CrossRef CAS PubMed.
- A. Sawada, K. Mori, S. Tanaka and M. Fukushima, Waste Manag., 2004, 24, 483–490 CrossRef CAS PubMed.
- V. K. Gupta, A. Nayak and S. Agarwal, Environmental Engineering Research, 2015, 20, 1–18 CrossRef.
- H. Cui, M. Fu, S. Yu and M. K. Wang, J. Hazard. Mater., 2011, 186, 1625–1631 CrossRef CAS PubMed.
- J. Chen, X. Hong, Q. D. Xie and Q. F. Zhang, J. Chem. Eng. Data, 2014, 59, 2275–2282 CrossRef CAS.
- X. C. Ren and P. Wang, ACS Nano, 2012, 6, 2693–2703 CrossRef PubMed.
- L. Fan, C. Luo, M. Sun and H. Qiu, J. Mater. Chem., 2012, 22, 24577–24583 RSC.
- Z. Cheng, J. Liao, B. He and L. Zhou, ACS Sustainable Chem. Eng., 2015, 3, 1677–1685 CrossRef CAS.
- Y. Wu, H. Luo, H. Wang, C. Wang and J. Zhang, J. Colloid Interface Sci., 2013, 394, 183–191 CrossRef CAS PubMed.
- K. S. Subramanian, Anal. Chem., 1988, 60, 11–15 CrossRef CAS PubMed.
- R. Katal, M. Ghiass and H. Esfandian, J. Vinyl Addit. Technol., 2011, 17, 222–230 CrossRef CAS.
- S. Li, X. Lu, X. Li, Y. Xue and J. Lei, J. Colloid Interface Sci., 2012, 378, 30–35 CrossRef CAS PubMed.
- M. Bhaumik, S. Agarwal, V. K. Gupta and A. Maity, J. Colloid Interface Sci., 2016, 470, 257–267 CrossRef CAS PubMed.
- J. Luo, H. J. Zhu, H. M. Fan, J. K. Liang, H. L. Shi and J. H. Rao, J. Phys. Chem. C, 2008, 112, 12594–12598 CAS.
- D. Jampaiah, V. K. Velisoju, P. Venkataswamy, V. E. Coyle, A. Nafady, B. M. Reddy and S. K. Bhargava, ACS Appl. Mater. Interfaces, 2017, 9, 32652–32666 CAS.
- Z. Liu, Y. Wang, R. Deng, L. Yang, S. Yu, S. Xu and W. Xu, ACS Appl. Mater. Interfaces, 2016, 8, 14160–14168 CAS.
- L. Han, P. Tang and L. Zhang, Nano Energy, 2014, 7, 42–51 CrossRef CAS.
- K. Anupam, S. Dutta, C. Bhattacharjee and S. Datta, Chem.
Eng. J., 2011, 173, 135–143 CrossRef CAS.
- S. C. Ponce, C. Prado, E. Pagano and F. E. Prado, Ecol. Eng., 2015, 74, 33–41 CrossRef.
- J. H. Chen, K. C. Hsu and Y. M. Chang, Ind. Eng. Chem. Res., 2013, 52, 11685–11694 CrossRef CAS.
- K. Zhu, Y. Gao, X. L. Tian and C. L. Chen, ACS Sustainable Chem. Eng., 2016, 4, 4361–4369 CrossRef CAS.
- L. Fan, C. Luo, M. Sun and H. Qiu, J. Mater. Chem., 2012, 22, 24577–24583 RSC.
- C. Luo, Z. Tian and B. Yang, Chem. Eng. J., 2013, 234, 256–265 CrossRef CAS.
- T. Yao, T. Cui, J. Wu, Q. Chen, S. Lu and K. Sun, Polym. Chem., 2011, 2, 2893–2899 RSC.
- M. Bhaumik, A. Maity, V. V. Srinivasu and M. S. Onyango, J. Hazard. Mater., 2011, 190, 381–390 CrossRef CAS PubMed.
- M. Bhaumik, S. Agarwal and V. K. Gupta, J. Colloid Interface Sci., 2016, 470, 257–267 CrossRef CAS PubMed.
- N. H. Kera, M. Bhaumik and N. Ballav, J. Colloid Interface Sci., 2016, 476, 144–157 CrossRef CAS PubMed.
- J. Chen, X. Hong and Q. Xie, J. Chem. Eng. Data, 2014, 59, 2275–2282 CrossRef CAS.
- T. Yamashita and P. Hayes, Appl. Surf. Sci., 2008, 254, 2441–2449 CrossRef CAS.
- S. H. Huang and D. H. Chen, J. Hazard. Mater., 2009, 163, 174–179 CrossRef CAS PubMed.
- N. H. Kera, M. Bhaumik, N. Ballav and S. S. Ray, J. Colloid Interface Sci., 2016, 476, 144–157 CrossRef CAS PubMed.
Footnote |
† Electronic supplementary information (ESI) available. See DOI: 10.1039/c8ra01805g |
|
This journal is © The Royal Society of Chemistry 2018 |
Click here to see how this site uses Cookies. View our privacy policy here.