Dongyun Sunab,
Wei Wang*a and
Zhaoping Liu*a
aNingbo Institute of Materials Technology and Engineering, Chinese Academy of Sciences, Ningbo, Zhejiang 315201, P. R. China. E-mail: wangwei@nimte.ac.cn; liuzp@nimte.ac.cn
bNano Science and Technology Institute, University of Science and Technology of China, China
First published on 30th May 2018
Graphene films grown by the chemical vapor deposition (CVD) method have attracted intensive attention due to their native advantages of both high quality and large quantity for commercial applications. However, previously reported graphene films have exhibited uncertain and conflicted electrical properties that greatly hinder them from being used to build reliable electrical devices because of incompatibility during the complex and multifarious transfer process. Herein, the relationship between the transfer parameters and electrical performance was systematically studied. It demonstrates that cracking during the transfer process causes significant loss of carrier mobility and hence an increase in sheet resistance. Additionally, unstable doping plays a key role in the carrier density and hence greatly influences the sheet resistance. By introducing HCl as a doping agent, graphene films with repeated sheet resistance of approximately 300 ohm sq−1 can be realized. This work establishes a facile and reliable route to fabricate graphene films with advanced and repeatable electrical properties, which is significant and essential for fair evaluation of CVD-grown graphene films and further practical applications.
Various transfer methods have been developed to solve those problems, including the polymer-assisted transfer method,17,18 the thermal release tape (TRT) method,19–21 and the glue-assisted method.22,23 Earlier methods involved growing graphene film on a Ni substrate and transferring it to a Si substrate by employing polydimethylsiloxane (PDMS) as an intermediate support layer.24 Polymethyl methacrylate (PMMA) has subsequently been widely accepted and used instead of PDMS to transfer graphene films and other ultrathin films, because it can be easily removed by solvents while maintaining clean and complete samples.25 However, the size of the resultant films in these approaches is usually limited to a few centimeters, which is not sufficiently large to be used as a next-generation transparent conducting films for building practical devices. It was firstly reported by Samsung that large scale graphene films with sizes up to 30 inches were successfully fabricated using thermal release tape as an intermediate transfer layer, which made it possible to build an operable and useful touch panel.20 This impressive progress had attracted broad attention, but the difficulty of operation led to some conflicting results in the reports that followed. Pressure-sensitive adhesive films and silicone films have been used as improved intermediate layers to produce graphene films that exhibit more advanced completeness and electrical properties.26 Moreover, Sony Corporation produced a 100 m-long high-quality graphene transparent conductive films by roll-to-roll CVD and transfer with the assistance of UV-glue bonding.23 Undoubtedly, the correct selection of the transfer method plays a key role in determining the final device performance.11,27–29
In addition to the numerous transfer methods, another non-negligible and irreplaceable function comes from the etchant for removing catalyst substrates, which usually contains iron chloride (FeCl3),30 iron nitrate (Fe(NO3)3),31 or ammonium persulphate ((NH4)2S2O8).20 For instance, Youngsoo Kim et al. reported a monolayer graphene film with sheet resistance of 923 + 148 Ω sq−1 by transferring CVD-grown graphene with PMMA and etching a Cu substrate with 0.02 mol L−1 (NH4)2S2O8 solutions.32 For the same growth and transfer process, other studies revealed diverse results with the sheet resistance of graphene films of 1520 + 67.7 Ω sq−1.33 Similar phenomena appeared in other etching systems. Li et al. removed the Cu substrate using a 0.05 g ml−1 Fe(NO3)3 solution for 12 h and obtained graphene films with a sheet resistance of approximately 2100 Ω sq−1.34 However, the sheet resistance of graphene films from other reports was 425 Ω sq−1.35 Moreover, for the FeCl3 etching system, two studies reported the sheet resistance of graphene films as 510 Ω sq−1 and 725 Ω sq−1.36,37 After broadly reviewing current reports describing the transfer of graphene films, it is noted that the resultant graphene films have quite different electrical properties.
Obviously, the fabrication of graphene films with unstable and uncertain physical properties would greatly prevent it from being used for practical applications. Thus, it is quite necessary and significantly important to establish a clear relationship between the transfer parameters and the electrical performance. In this work, by systematic study, a standard transfer process for graphene films was successfully established with repeated sheet resistance, which is significantly important for evaluating the quality of CVD-grown graphene films and also for the use of next-generation transparent conducting films in practical applications.
The CVD-grown graphene film on the Cu was transferred to a PET substrate through different approaches, including the PDMS method,24 PMMA method,31 TRT method20 and UV glue method.23 For the typical UV glue method, a Cu foil with graphene film on its surface was bonded onto PET film with UV glue (HUITIAN, 3118). Subsequently, the epoxy was cured using a UV curing machine (GLINTSUN, GS-300-2PM). Then, the Cu was etched by different etchants, including ammonium persulphate (NH4)2S2O8, iron chloride (FeCl3), and iron nitrate (Fe(NO3)3) solutions. Finally, the graphene/PET film was washed with deionized water several times to remove any etchant residuals and was then dried under an atmospheric environment.
The sheet resistance of graphene on a 5 cm × 5 cm square of PET was measured with a four-point probe (Suzhou Jingge Electronic Co., Ltd., ST2258A) at room temperature. The sheet resistance mapping measurement was carried out with a sheet resistance mapping system (SURAGUS, EddyCus TF map 2525 SR). The morphology of graphene on the PET film was characterized by field emission-scanning electron microscopy (FE-SEM, Hitachi S-4800) and atomic force microscopy (AFM, Dimension 3100). Raman spectra were obtained on graphene films transferred by the PMMA-assisted method using a Renishaw microspectrometer with a laser wavelength of 514 nm. X-ray photoelectron spectroscopy (XPS) measurements were performed using a Kratos Axis Ultra delay-line detector (DLD) spectrometer (Kratos Analytical). The Hall Effect Measurement System (HALL 8800) was used to measure the carrier mobility and carrier density of graphene film with 7200 magnetic strength.
Because the graphene films on Cu foil are fabricated through exactly the same CVD process, it is quite necessary to investigate the resultant graphene films on PET in detail to further understand their nature. As shown in Fig. 1c–f, the corresponding surface morphologies are characterized by FE-SEM. It should be mentioned that no additional conducting layer was sputtered on the surface in order to ensure the original conditions. Greatly inhomogeneous surfaces with obvious contrast difference can occur, especially in PDMS sample. It is known that poor electrical conductivity during SEM leads to an electrical charge effect.21,38 Here, the brighter area might suggest that a poor electrical connection exists, which is due to the cracks that occur during the transfer process. The block of electrical connection would greatly influence the carrier transport and hence decrease the carrier mobility. For comparison, the SEM image of the UV-glue sample is quite uniform on the entire surface with slight wrinkles, which suggests improved carrier mobility. Thus, the final sheet resistance can be significantly different for samples prepared by different transfer methods. AFM measurements were also performed to analyze the microstructures of transferred graphene films, such as ripple or domain boundary,39,40 as shown in the insets of Fig. 1c–f. The AFM image of graphene films transferred by the PDMS method exhibits a large oscillation with dense and obvious contrast in some areas. The contrast oscillation becomes much less pronounced in the samples transferred by the TRT and PMMA methods. Finally, it looks quite smooth on the UV-glue assisted transferred graphene film with only slight wrinkling, which is due to the mismatch of the coefficient of thermal expansion between copper and carbon. The results are consistent with the SEM results of graphene films using different transfer methods.
The electrical performance of graphene films using different etchants with the same UV-glue transferring method is compared in Fig. 2. For all samples where different etchants were used, including (NH4)2S2O8, FeCl3, and Fe(NO3)3 solutions, the sheet resistance of the graphene films gradually decreases as the concentration of etching solutions was increased. Among these three etchants, the graphene films etched in (NH4)2S2O8 exhibited the corresponding lowest sheet resistance. The carrier density and carrier mobility of these samples were investigated in detail, and as shown in Fig. 2b, the carrier mobility of graphene films using the same etchant did not greatly change as the etchant concentration increased, and that of graphene films etched in (NH4)2S2O8 presents the highest value among these three etchants. In contrast, the carrier density of these graphene films increased significantly as the corresponding etchant concentration increased, as shown in Fig. 2c. Although the carrier density of graphene film etched in (NH4)2S2O8 is lower than that of the other samples, the lower sheet resistance is still realized in graphene films etched in (NH4)2S2O8, which originates from the large enhancement of carrier mobility. It can be concluded that an increase in ion concentration may not affect the carrier mobility, which remains with an unchanged electrical connection, but greatly enhances the carrier density and hence reduces the sheet resistance.
Fig. 2 The relationship between (a) sheet resistance, (b) carrier mobility, and (c) carrier density of graphene films and the concentration of different etchants. |
Based on the above analyses, to further improve the electrical conductivity of graphene films, it is very important to find a method that will increase the carrier density without the loss of carrier mobility. This requirement can be satisfied by introducing dopant during the transfer process, and this has been broadly studied.20,41,42 During the above studies, it was found that the pH value decreases as the etching process proceeds. Thus, H+ ions as dopant were systemically studied herein to determine if this could further improve graphene films. Fig. 3a–c presents the electrical properties of graphene films etched in (NH4)2S2O8 solution plus different acids. The sheet resistance of graphene films generally decreases as the concentration of additional acids increases. For HNO3 and H2SO4 as dopants, the carrier mobility of graphene films remains smooth while the corresponding carrier density increases as the concentration of acids increases, which leads to an overall decrease in sheet resistance. The lowest sheet resistance was realized in (NH4)2S2O8 etchant with 1.2 M HCl. With increasing HCl concentration, the sheet resistance sharply increased, and with HNO3 and H2SO4, the carrier mobility of samples in HCl linearly decreased. With careful observation as shown in Fig. 3h, the addition of HCl greatly increased the etching speed compared to the other samples. Additionally, as demonstrated in Fig. 3i, which shows the bottom view of samples during the transfer process, abundant bubbles can be generated as the concentration of HCl increases, which suggests that the violent reaction during the etching process might cause the loss of electrical connections and hence a decrease in carrier mobility. However, the corresponding carrier density sharply increases when HCl is used at concentrations lower than 1.2 M but with a lower slope above 1.2 M. As concluded in the above paragraph, it is necessary to maintain a good electrical connection and hence the carrier mobility. Herein, a suitable HCl concentration could enable the balance between the carrier mobility and carrier density to reach the lowest sheet resistance of approximately 300 ohm sq−1. Sheet resistance mapping measurements were also performed to reveal the exact electrical performance of 5 cm × 5 cm graphene films by detecting eddy current signals, as shown in Fig. 3d–g. The sheet resistance mapping of graphene film using only (NH4)2S2O8 etchant exhibits complex color units over the entire sample, which indicates the quite disordered distribution of sheet resistance in the range of 350–700 ohm sq−1. After adding different acids, the sheet resistance was significantly reduced, and the homogeneity of the sheet resistance was greatly improved with much more uniform color distribution. Among these three types of acids, the sample with the addition of HCl exhibited the lowest sheet resistance, of approximately 300 ohm sq−1. These results are consistent with the four-probe measurements and Hall effects measurements.
Fig. 4 summarizes the electrical properties of graphene films treated with different etchants. The graphene films etched in (NH4)2S2O8 etchant exhibited lower sheet resistance compared to that of FeCl3 and Fe(NO3)3 etchants, which is derived from the contribution of higher carrier mobility. With the addition of HCl as a doping agent, the carrier density of samples in (NH4)2S2O8 etchant plus HCl becomes more uniform in the range of 2000–2400 cm2 V−1 s−1 compared to a broad range of 1300–2500 cm2 V−1 s−1 for samples in bare (NH4)2S2O8 etchant. The corresponding carrier density of samples in the (NH4)2S2O8 etchant plus HCl is also significantly improved in a narrow range of 9–12 × 1012 cm−2 compared to 4–10 × 1012 cm−2 for samples in bare (NH4)2S2O8 etchant. Thus, the sheet resistance of graphene films using HCl dopant reaches the lowest value of approximately 300 ohm sq−1 and is also in a much narrower range of 270–380 ohm sq−1 compared to the broad range of 350–700 ohm sq−1 for the graphene films treated with bare (NH4)2S2O8 etchant. This demonstrates that the sheet resistance of graphene films can be repeatedly realized in a quite narrow range using (NH4)2S2O8 etchant plus 1.2 M HCl dopant. For the original graphene films, the G peak is at approximately 1582 cm−1 and the D band is at approximately 2700 cm−1. The doped graphene will exhibit an upshift of the G band and 2D band.43–46 Fig. 4d presents the Raman spectra of as-obtained graphene films using different etching solutions. It clearly shows that the G band of graphene films etched in Fe(NO3)3 and FeCl3 is slightly upshifted compared to that of the (NH4)2S2O8 sample, which is consistent with the carrier density action in Fig. 2c. The higher G band was upshifted to 1596 cm−1 in graphene films using (NH4)2S2O8 etchant plus 1.2 M HCl dopant, which is also of the highest carrier density and hence lowest sheet resistance.
To further study the doping effect of different etchants, XPS measurements were also carried out, as shown in Fig. 4e and f. The C 1s peaks of the graphene films etched by different etchants are divided into three symmetric Gaussian curves, which are assigned to C–C, C–O, and CO, respectively. For the p-doping of graphene films, the C 1s peaks corresponding to the sp2 and sp3 hybridized states were shifted to lower energy,20,47 which is similar to the case for p-doped carbon nanotubes.48 The peaks at 288.372 eV, 289.049 eV, 289.084 eV, and 289.097 eV correspond to the CO peaks for graphene films using (NH4)2S2O8 etchants plus HCl, FeCl3 etchants, Fe(NO3)3 etchants, and (NH4)2S2O8 etchants, respectively. The CO peak is obviously redshifted by 0.73 eV, and the C–C peak is redshifted by 0.16 eV after the addition of HCl dopant in (NH4)2S2O8 etchants, which is consistent with the Raman results.
This journal is © The Royal Society of Chemistry 2018 |