Xiaofeng Lin‡
,
Wensheng Lin‡,
Meijia Yang,
Jiayao Chen,
Dingshan Yu,
Wei Hong and
Xudong Chen*
Key Laboratory for Polymeric Composite and Functional Materials of Ministry of Education of China, Guangdong Engineering Technology Research Center for High-performance Organic and Polymer Photoelectric Functional Films, School of Chemistry, Sun Yat-sen University, Guangzhou 510275, P. R. China. E-mail: cescxd@mail.sysu.edu.cn
First published on 9th November 2018
The chain reaction amplification mechanism (CRAM) has been extensively studied, but it has not been effectively developed at the molecular scale and still needs to consume amounts of monomers to show the macroscopic phenomenon needed for detection. Herein, rationally-designed silica-coated silver nanoparticles with acrylic acid-functionalization were used as a plasmonic nanosensor to realize highly sensitive and fast colorimetric glucose detection with less monomer consumption, which effectively integrated CRAM with the localized surface plasmon resonance effect, developing CRAM at the molecular scale. The glucose detection mechanism of the proposed sensor was based on free-radical polymerization by biocatalytic initiation, which would induce the aggregation of Ag NPs, leading to a decrease in the plasmon resonance intensity. As a result, the detection limit could reach 2.06 × 10−5 M, 10 times lower than that of a commercial glucose assay kit with a limit of 1.1 × 10−4 M. Moreover, FDTD simulation further confirmed that the intensity of the extinction gradually decreased with an increase in the degree of aggregation of Ag NPs. The approach could be used for high selectivity toward glucose detection and would be suitable for other practical applications of the detection of low concentrations of glucose.
Compared with the method of SERS, localized surface plasmon resonance (LSPR) could focus the light on the vicinity of the nanoparticles, resulting in the formation of an enhanced electromagnetic field on the surface of the nanoparticles.12,13 Such unique optical properties could be applied in numerous significant applications in various research fields, such as plasmon-assisted catalysis,15 solar cells,16,17 plasmonic sensors,18–20 the detection of single molecules,21,22 luminescence enhancement,23,24 etc. In particular, owing to the low consumption and high sensitivity of the SPR peaks depended on the refractive index of the surrounding medium,25 the plasmonic sensors based on the LSPR effect could improve the SERS's problems of the substrate preparation and the quantitative detection. However, the sensitivity of sensors based on the LSPR effect still need to be further enhanced for the development of glucose detection.
In order to further improve this situation, the chain reaction amplification mechanism (CRAM) is an efficient way of using chain reactions to dramatically amplify the sensitivity of the sensing,26–28 which could reach the sensitivity level of femtomoles, or even zeptomoles. Moreover, CRAM could even be combined with an enzyme-linked immuno sorbent assay to further decrease the detection limit of biomolecules and is attracting extensive attention.29 However, traditional sensing based on CRAM systems needs to consume a large number of reactive monomers in order to present a macroscopic phenomenon via numerous double bond polymerizations.
Consequently, if the LSPR effect could be combined with the more sensitive detection method of CRAM, efficient sensors with less monomer consumption, lower detection time and higher sensitivity could be obtained. To this end, we have demonstrated a new class of plasmonic nanosensor based on acrylic acid-functionalized silica-coated silver nanoparticles, which effectively integrate CRAM with the LSPR effect, to realize highly sensitive and fast colorimetric glucose detection with less monomer consumption. The newly-developed sensor showed a limit of detection (LOD) of 2.06 × 10−5 M, 10 times lower than that of a commercial glucose assay kit with a limit of 1.1 × 10−4 M. The glucose detection mechanism of the proposed sensor was based on free-radical polymerization by biocatalytic initiation, which would induce the aggregation of Ag NPs and thereby cause a decrease in plasmon resonance intensity. Simultaneously, the detection sensitivity was strongly dependent on the degree of aggregation of the Ag NPs, which was confirmed by FDTD simulation. The approach could be used for high selectivity toward glucose detection and would be suitable for other practical applications of the detection of low concentrations of glucose.
GOx + glucose gluconic acid + H2O2 | (1) |
FeII + H2O2 FeIII + ·OH + HO− | (2) |
The glucose was catalyzed by GOx to produce H2O2 (eqn (1)), which was subsequently reduced by FeII ions to yield ·OH free radicals (eqn (2)). The ·OH radicals initiated the polymerization of acrylic acid monomers on the silica surface and changed the LSPR resonance wavelength recorded by the UV-VIS-NIR spectrophotometer. The technique of electron spin resonance (ESR) was used to confirm the existence of ·OH after the addition of FeII in the glucose detection. It was obviously observed that the DMPO/·OH signal intensity of the ESR spectra in the presence of FeII was higher than that without FeII or with acrylic acid-functionalized Ag@SiO2 NPs, which exhibit an intensity ratio of 1:2:2:1 from Fig. S2 (ESI†). The results showed that ·OH actually existed in the system of glucose detection, which could induce the aggregation of the acrylic acid-functionalized Ag@SiO2 NPs.
In general, the polymerization led to the coupling of Ag NPs. The thinner the silica shell was, the more sensitive the plasmonic nanosensor would be. However, if the silica shell was too thin, the spacer could not efficiently protect the Ag NPs from aggregation when FeII ions were added.34 The thickness of the silica shell could be readily adjusted to optimize the sensitivity of the plasmonic nanosensor and the optimal thickness of the silica shell is about 10 nm. Herein, the thickness of the silica shell as a spacer layer should be adjusted to make the plasmonic nanosensor more sensitive when the distance between the Ag NPs changed. For a typical silica coating, a freshly prepared citrate-stabilized Ag colloid was safely transferred into ethanol followed by intermittent addition of TEOS solution. The TEM images (Fig. 2A) show that the obtained Ag@SiO2 NPs had a silica coating layer of ca. 10 nm on the surface of the Ag NPs when 4 mL of 10 mM TEOS ethanol solution was used for synthesis. A relatively rough silica surface was observed, which was attributed to the short particle radius (R−1), while the rough surface of the Ag@SiO2 NPs would not affect our experimental result.35 Subsequently, in order to retain the thickness of the silica coating layer, each particle was coated only with the desirable APTMS layer used in the functionalization step, assuming one APTMS molecule to occupy 0.4 nm2 on the nanoparticle surface.36 The ethanol solution of APTMS (1 mL, 10 mM in ethanol) was added to 50 mL of Ag@SiO2 solution with vigorous stirring. Before being grafted onto the Ag@SiO2 NPs, the acrylic acid should be activated by EDC/NHS and incubated for at least 2 h for efficient activation. The surface-grafted amine groups of the silica shell reacted with the activated carboxyl groups of acrylic acid to form an ester group, eventually yielding acrylic acid-functionalized Ag@SiO2 NPs. As shown in Fig. 2B, there was no significant change in the thickness of the spacer layer for acrylic acid-functionalized Ag@SiO2 compared with the Ag@SiO2 NPs (Fig. 2A). An obvious red-shift of ca. 14 nm and a broadened half-peak width in the plasmon resonance band of acrylic acid-functionalized Ag@SiO2 NPs could be observed in the UV-visible spectra (Fig. 1C) as compared to those of Ag NPs (ca. 50 nm in diameter, see Fig. S3 in ESI†), due to the increased refractive index of the surrounding medium from the Ag NPs.25
Since there is no absorption for other species (GO, GOx, FeII ions) in our sensor system in the wavelength range of 300–800 nm, the variations in the plasmon resonance of acrylic acid-functionalized Ag@SiO2 NPs band at a wavelength of 436 nm were selected as the sensor response signal (Fig. S4, see ESI†). For this proposed sensing system, the variation in plasma resonance should be caused by glucose alone; therefore, reference tests without glucose were carried out under identical conditions to confirm our supposition. Within the observation time (10 min), no spectral variation was found, which indicated that the variation in the spectrum was not affected by different concentrations of FeCl2 and was actually caused by the glucose-induced polymerization (see Fig. S5 in ESI†).
The reaction initiated by redox was influenced by the components of the glucose, FeCl2 salt and monomer concentration in this reaction system. In particular, the FeIII ions would compete with the acrylic monomer for ·OH radicals in the case of too high a concentration of FeCl2 salt in the reaction system, leading to a decrease in the polymerization efficiency. However, a low concentration of FeCl2 salt would result in too slow polymerization, which could pose difficulty in detecting the variation in the spectrum over a suitable time range. Aiming to find an optimal concentration of FeCl2 and an appropriate observation time, we varied the dosage of FeCl2 from 2 to 20 μL into the 6 mM glucose solution to perform a series of measurements. Subsequently, the results of the UV-vis spectra (see Fig. S6 in ESI†) have shown that the absorption intensity at 436 nm showed a rapid decay with an increase in the dosage of FeCl2 (from 4 to 10 μL). It is well known that the rate of redox initiating reaction would be faster with an increase of the dosage of FeCl2, leading to acceleration of the polymerization, while the polymerization would induce the aggregation of Ag NPs and thereby cause a decrease in the plasmon resonance intensity. But, the absorption from adding 2 μL of FeCl2 showed no significant change within the testing time of 40 min. This is because too small an amount of initiator (FeCl2) causes a very slow polymerization process (see Fig. S6A in ESI†). On the other hand, the spectral change of each glucose concentration (see Fig. S6F in ESI†) would be insignificant after adding too much FeCl2 (20 μL), which was ascribed to a too fast polymerization reaction that led to little difference in degree of polymerization in each sample. Finally, considering that it was a typical time range for glucose blood tests, we have selected 3 min as the reaction time. Meanwhile, an appropriate dosage of 10 μL FeCl2 was chosen for the test.
Our proposed mechanism of glucose detection by acrylic acid-functionalized Ag@SiO2 NPs was that the polymerization would lead to the coupling of Ag NPs, and consequently decrease the intensity of dipolar resonance. Hence, the sensor response as a function of glucose concentration around the human physiological range in blood concentration (the normal value in humans is 6.0 mm) was plotted in Fig. 3, which clearly shows a linear dependence of absorbance band maximum versus glucose concentration with a coefficient of 0.995 (Fig. 3B). The photographs of the color variation with different glucose concentrations in the plasmonic sensing devices are shown in Fig. S7.† Additionally, as shown in Fig. 3C, the TEM image of Ag@SiO2 NPs after polymerization could further confirm our mechanism that the polymerization actually caused the aggregation of Ag NPs, resulting in a reduction in the intensity of dipolar resonance.
According to a previous report, along with the aggregation of Ag NPs, the dipolar resonance from the Ag NPs at a wavelength of 420 nm would generally decrease in intensity and undergo a slight red shift. In addition, a new multipolar resonance would initially appear at a longer wavelength due to coupling between the Ag NPs.37 However, only the decrease in the dipolar resonance intensity could be observed without any multipolar resonance at a longer wavelength. Such a phenomenon could be attributed to two reasons as follows: first, the Ag NPs were coated with a silica shell as an outside spacer that protected the Ag NPs from severe aggregation. Second, the reaction time (3 min) of the glucose detection might be too short to generate the new resonance, which could not reach the degree of aggregation.
Moreover, FDTD simulation was implemented to further confirm our experimental results. In order to simplify the calculation system, the FDTD simulation calculated the plasmon resonance peak of ten Ag NPs with various degrees of aggregation. With the degree of aggregation increasing, the clusters in the system would gradually decrease. Simultaneously, the N would be set to characterize the degree of aggregation, which could be defined as the ratio of the total amount of Ag NPs to the number of clusters (N = nAg NPs/nclusters). According to Fig. 4A–E, the values of N were enhanced from 1 to 1.67 with an increase in the degree of aggregation in addition, Fig. 4F presents the simulation results for the intensity of the plasmon resonance peak. Clearly, the intensity of the extinction gradually decreased with an increase in the degree of aggregation, in line with our aforementioned experiment.
In a practical application, other species in the analytical sample should not disturb the signal, which is a typical concern for the operation of biosensors. Therefore, a series of reference experiments using other common interfering species, such as ascorbic acid, D-fructose, β-cyclodextrin, lactose and maltose instead of glucose, have been conducted under identical conditions. And there were no signals detected (see Fig. S8 in ESI†), showing high selectivity toward glucose detection. Additionally, another concern for practical application is repeatability. Therefore, 10 sensors were prepared in the same way to detect a glucose solution with a concentration of 6 mM (see Table 1), which showed that the sensors had good repeatability with a standard deviation of 2.5%.
Samples | Plasmonic biosensor | Commercial glucose assay kit |
---|---|---|
1. | 6.0 ± 0.2 mM | 6.0 ± 0.1 mM |
2. | 6.0 ± 0.2 mM | 6.0 ± 0.1 mM |
3. | 6.1 ± 0.3 mM | 5.9 ± 0.2 mM |
To further verify the practicability of the plasmonic nanosensor, it was used for the detection of the glucose concentration in fetal bovine serum and compared with a commercial glucose assay kit (see Fig. S9 in ESI†). According to Table 1, the performance of our plasmonic nanosensor could be comparable to the commercial glucose assay kit, indicating that the proposed nanosensor is suitable for practical applications. In addition, solutions of simulated tears (ca. 0.92 mM for diabetics, ca. 0.51 mM for normals)38 were prepared to further investigate the practicability of the plasmonic nanosensor (Table S1 and Fig. S10†). In addition, the LOD of our plasmonic nanosensor could reach 2.06 × 10−5 M, 10 times lower than the limit of the commercial glucose assay kit of 1.1 × 10−4 M. The developed approach can not only be used in a blood glucose monitor, but can also be utilized as a convenient tool to detect very low concentrations of glucose in solution.
Footnotes |
† Electronic supplementary information (ESI) available. See DOI: 10.1039/c8ra07043a |
‡ X. F. Lin and W. S. Lin contributed equally to this work. |
This journal is © The Royal Society of Chemistry 2018 |