DOI:
10.1039/C9RA02364J
(Paper)
RSC Adv., 2019,
9, 16472-16478
Highly stable binder free CNTs/rGO aerogel electrode for decolouration of methylene blue & palm oil mill effluent via electro-Fenton oxidation process
Received
28th March 2019
, Accepted 21st May 2019
First published on 28th May 2019
Abstract
In this study, single wall carbon nanotubes (CNTs)/reduced graphene oxides (rGO) aerogels were prepared by a one-pot hydrothermal process without using a binder. The produced CNTs/rGO aerogel was used as cathode in electro-Fenton system for the decolouration of methylene blue (MB) and palm oil mill effluent (POME). The addition of CNTs increased the surface area, pore volume and conductivity of the rGO aerogel, which further enhanced their performance as cathode towards the decolouration of MB and POME via electro-Fenton reaction. Complete decolouration of MB using rGO aerogel without CNTs could not be achieved. The effect of electro-Fenton reaction parameters conducted using the aerogel samples including, current, electrolyte concentrations and pH, were investigated accordingly. The CNTs/rGO aerogel electrode also showed high stability and reusability for up to six consecutive treatment cycles for MB. Besides, the CNTs/rGO aerogel also showed good performance in treating POME with 69.8%, 47.6% and 58.1% of reduction in true colour, total organic carbon (TOC) and chemical oxygen demand (COD), respectively, via 60 minutes electro-Fenton reaction. This study showed that CNTs/rGO aerogels with high porosity and stability can be prepared using simple procedure without adding binder. This fully carbon-based aerogel can serve as effective cathode for decolouration of organic dye and effluent.
1 Introduction
Advanced oxidation processes (AOP) have been popular methods for wastewater treatment, including ozonation, UV treatment, physical AOP (ultrasound, microwave, electro beam) and catalyst AOP (photocatalyst, Fenton reaction).1–6 Electro-Fenton process is known as electrochemical advanced oxidation process (EAOP) with high efficiency in decomposition of destructing persistent organic pollutants by hydroxyl radicals (˙OH).7,8 Hydrogen peroxide (H2O2) is produced from the cathode of the electro-Fenton system which is subsequently reacted with ferrous ions (Fe2+) to produce ˙OH as indicated in eqn (1).9–11 |
H2O2 + Fe2+ + H+ → ˙OH + H2O
| (1) |
In situ generation of H2O2 is the core component for the production of ˙OH radicals in electro-Fenton process.11,12 H2O2 is reactive and unstable. In situ generations of H2O2 eliminates the risk of transportation and storage of H2O2.11,12 H2O2 is produced at cathode involving two-electrons oxygen reduction reaction as indicated in eqn (3).9,10 The efficiency of the H2O2 production is a key parameter of the electro-Fenton process.
|
O2 + 2H+ + 2e− → H2O2
| (2) |
Hence, the improvement of cathode material to increase H2O2 production is of high importance for enhancing the efficiency of the electro-Fenton process. Carbonaceous materials, including graphite,13 carbon felt,14,15 carbon sponge,16 carbon aerogel,17 and activated carbon fibre18,19 are among the widely studied cathode materials for electro-Fenton process due to their advantages such as good stability, high conductivity, low cost, non toxic and low catalytic activity for H2O2 decomposition.11 Besides, uses of polymer binder in the production of carbonaceous electrode is avoided as it can limit the performance by reducing the conductivity of electrode.20 Therefore the design on binder-free electrodes are established with the presence of CNTs to improve mechanical and electrical properties of the electrodes.21–24
In this study, reduced-graphene oxide (rGO) aerogel is produced and used as cathode material for electro-Fenton process. To further enhance the conductivity of the electrode, CNTs are added into the rGO as conductive filler to further enhance the conductivity properties of the electrode. The CNTs are treated by nitric acid before used. This is because CNTs has high hydrophobic characteristic and low wettability which limit the access of ions and presence of active site for electron transfer. Chemical treatment of CNTs can increase oxygen-containing functional groups (carboxylic acid, carbonyl and hydroxyl), which can increase accessible sites for free electrolytes ions and help in enhancing the homogeneity of CNTs in GO solution for the preparation of well-dispersed CNTs/rGO aerogel electrode.23,25 Aggregation of CNTs can occur when electrical repulsive forces are lower than the van der Waals force which are important to induce repulsion force for better CNTs dispersion.26 Besides, dispersion of CNTs is important for high electrode stability and conductivity, while the presence of GO can act as surfactant which can enhance the dispersion of CNTs.27
The produced CNTs/rGO electrodes are further tested in the decolouration process of organic dye using an electro-Fenton system. Herein, few parameters are studied, such as CNTs loading, electric current intensity, pH, and electrolyte concentration, for the optimization of the electro-Fenton process. The stability and reusability of the electrodes are also determined. To further evaluate the viability of the CNTs/rGO aerogel for real application, the aerogel was used to treat palm oil mil effluent (POME) using the optimum electro-Fenton condition for MB. The electro-Fenton performance was evaluated in terms of decolouration, reduction of total organic carbon (TOC) and chemical oxygen demand (COD).
1.1 Materials and methods
1.1.1 Materials. Carbon nanotubes (CNTs) (75% purity, <15% metal impurities). Graphite flakes (32461, 100 mesh ≥75%), sodium sulfate (Na2SO4), methylene blue (MB) hydrate and ferrous sulfate heptahydrate (FeSO4·7H2O) were purchased from Sigma-Aldrich (St Louis, MO). Potassium permanganate (KMnO4) (99 wt% purity), sulfuric acid (H2SO4) (98 wt% purity), nitric acid (HNO3) (65%) and hydrogen peroxide (30 wt% purity) were purchased from Merck (Darmstadt, Germany). Ascorbic acid was purchased from R&M Chemicals.
1.1.2 CNTs treatment. 2.5 g of raw CNTs was dispersed in deionized water using ultrasonication 3 minutes and then treated with nitric acid (8.0 M) in a reflux system at room temperature. After that, the CNTs were washed several times by filtration using deionized water until it reaches pH 7. The washed CNTs were then dried in a vacuum oven at 80 °C overnight.
1.1.3 Preparation of CNTs/rGO aerogel. Graphene oxide (GO) was synthesized from the oxidation of graphite flakes using a modified Hummers method.28 To prepare aqueous dispersed CNTs/GO, CNTs (15 and 30 mg) was added into 20 ml GO (50 mg) and homogenized by ultrasonication for 3 minutes. 0.15 g of ascorbic acid was added into the resulting CNTs/GO dispersion and stirred for 10 minutes using magnetic stirrer. Ascorbic acid acts as green reducing agent to reduce GO.29 The mixture was then transferred into an Teflon-lined autoclave and heated in an oven at 200 °C for 12 hours. The obtained CNTs/rGO hydrogel underwent phase transfer by immersing in distilled water for 3 days to exchange former solution inside hydrogel, and followed by freeze-drying process to produce aerogel. The CNTs/rGO with 15 mg and 30 mg of CNTs content were denoted as 30%-CNTs/rGO and 60%CNTs/rGO respectively. rGO aerogel was also produced as the control sample. Fig. 1 summaries the overall fabrication procedure of CNTs/rGO hydrogel and aerogel.
|
| Fig. 1 Synthesis scheme for rGO and CNTs/rGO aerogels: (a) hydrogel and (b) aerogel. | |
1.1.4 Characterization of the rGO and CNTs-rGO aerogels. A beaker-type three-electrode cell was used to analyze electrochemical properties of the rGO and CNTs/rGO aerogels, in which platinum plate and Ag/AgCl electrode were used as counter and reference electrode respectively. The working electrode consists of CNTs/rGO with different CNTs concentrations (15 and 30 mg). Cyclic voltammetry measurements were conducted using a Potentiostat/Galvanostat/ZRA (Reference 600, Gamry Instrument). The morphology and structure of the aerogel samples were examined on a field-emission scanning electron microscopy (FESEM, Zeiss Merlin). Nitrogen adsorption/desorption isotherms were obtained at 77 K on an automated adsorption device (Micromeritic ASAP 2020) to measure the surface area of aerogel using the Brunauer–Emmett–Teller (BET) method. Bulk resistance of the aerogels was measured using a multimeter (Victor VC890D).
1.1.5 Electro-Fenton oxidation experiments. Electro-Fenton experiments were conducted in a 100 ml beaker equipped with two electrodes that are totally immersed into the solution and filled with 50 ml methylene blue (MB) solution. The experiment set up is shown in Fig. 2. CNTs/rGO aerogel (1.5 cm × 1 cm) was used as cathode, while a platinum plate (1.5 cm × 1 cm) was used as anode. The distance between cathode and anode was fixed at 1 cm and remained constant for all experiments. A magnetic stirrer was used to provide a continuous vigorous stirring of the solution. The solution was aerated for 10 min using an air pump prior to the reaction and continued to the end of experiment to maintain the dissolved oxygen content of the solution. H2SO4 was added to obtain the required pH before starting the electro-Fenton process. A certain quantity of FeSO4·7H2O was added into the solution with the desired concentration. Na2SO4 was added to the solution with certain concentration to maintain the ionic strength and improve the conductivity of the medium. A potentiostat was connected to the electrodes and worked with a constant current. Besides MB, discolouration of palm oil mill effluent (POME) was also conducted using the CNTs/rGO aerogel by applying the optimum parameters obtained from the treatment of MB. The POME was filtered before used to remove suspended solids that might affect the efficiency of treatment.
|
| Fig. 2 Schematic diagram of electro Fenton reaction system: (a) anode, (b) cathode, (c) magnetic stirrer, and (d) aeration. | |
1.1.6 Analytical procedure. The concentration of MB and true colour of POME were measured by taking aliquot samples (1 ml) every 5 minutes and filtered using PTFE membrane (0.2 μm) to remove any suspended materials before measurements using a UV-VIS spectrophotomter (Jenway, 7315) at 664 nm and a VIS spectrophotometer (Hach DR 3900) at 455 nm, respectively. TOC and COD analyses were performed according to standard direct method (Method 10173) and USEPA reactor digestion method (Method 8000) respectively. The concentration of H2O2 generated during the electro-Fenton experiment was quantified by potassium permanganate titration method.30 Dissolved oxygen (DO) content of the MB solution was measured throughout the treatment process using a multimeter with luminescent/optical dissolve oxygen (LDO) probe (HQ30D).
2 Results and discussion
2.1 Characterization of aerogels
2.1.1 SEM and BET. The microstructure and morphology of the rGO and CNTs/rGO aerogels were observed under SEM. Fig. 3a shows that the rGO aerogel contains stacked graphene sheets with wrinkle-like structure. Wrinkle like structure of graphene sheets can provide high surface and increase active sites for the electron transfer for the generation of hydrogen peroxide.31 In Fig. 3c, wrapping of rGO sheets toward CNTs and interconnected rGO sheets by CNTs can be seen. With the entanglement between CNTs and rGO sheets, it can help in electron transfer and adsorption of electrolyte ions. According to SEM images in Fig. 3b and d, the pore size of rGO aerogel is larger compared to CNTs/rGO aerogel and entanglement of CNTs with rGO sheets can be clearly seen. The stacked structure of CNTs/rGO aerogel is considered more promising to be used as electrochemically active material compared to rGO aerogel by offering higher surface area and active sites for the generation of H2O2.
|
| Fig. 3 FESEM images of (a) rGO surface, (b) rGO cross section, (c) 60 wt%-CNTs/rGO surface, (d) 60 wt%-CNTs/rGO cross section. | |
To further support findings obtained from the FESEM, surface area, pore volume and pore size of the aerogel samples were measured using BET analysis, as shown in Table 1. The presence of CNTs helps in increasing the surface area and active sites.24,32
Table 1 BET surface area, pore volume and average pore size of rGO, 30%-CNTs/rGO and 60%-CNTs/rGO aerogels
Sample |
BET surface area (m2 g−1) |
Pore volume (cm3 g−1) |
Average pore (Å) |
rGO |
38.83 |
0.3487 |
649.0 |
30%-CNTs/rGO |
156.7 |
0.678 |
381.1 |
60%-CNTs/rGO |
256.9 |
1.302 |
169.8 |
Due to the high roughness and porosity of the aerogel surfaces, bulk resistance was measured instead of sheet resistance. Bulk resistance of the rGO aerogel was decreased from approximately 20 kΩ to 40 and 18 Ω with the addition of 30% and 60% CNTs, respectively. The high resistance of the rGO aerogel could be due to it high porous structure in which the rGO sheets are not well interconnected. The CNTs added have served as conductive pathway to interconnect the rGO sheets. It is interesting to note that the addition of CNTs not only has increased the BET surface area and pore volume of the aerogels, but it has also significantly enhanced the bulk conductivity of the aerogel.
2.1.2 Cyclic voltammetry. The cyclic voltammograms of the rGO and CNTs/rGO aerogels which were collected at the same scan rate of 10 mV s−1 are shown in Fig. 4a. It could be seen that the 60%-CNTs/rGO aerogel yielded the highest current density and enlarged curve area as compared to the rGO and 30%-CNTs/rGO aerogels. Fig. 4b shows that the increase in electrolyte concentration would result in improvement in solution conductivity and electron transfer.
|
| Fig. 4 (a) Comparison of the CV of rGO and CNTs/rGO aerogels. Conditions: pH 3, current 80 mA, 0.1 M Na2SO4, (b) CV of 60%-CNTs/rGO aerogel with different electrolyte concentrations. Conditions: pH 3, current 80 mA and 10 mV s−1. | |
2.1.3 Electrochemical impedance spectroscopy. Electrochemical impedance spectroscopy (EIS) analyses were carried out to understand better how CNTs affect the internal resistance of the rGO aerogel. Nyquist plots of the CNTs/rGO aerogel with different mass ratios of rGO to CNTs are shown in Fig. 5. The Nyquist spectra can be fitted with a modified Randles circuit. The resulting equivalent circuit parameters are listed in Table 2. It can be seen that the introduction of CNTs, 30 wt% and 60 wt%, has reduced the internal resistance (R1) of the rGO aerogel from 20.37 ohm to 7.872 ohm and 7.154 ohm, respectively. This enhancement is consistent with the measurement of bulk resistance of the aerogels.
|
| Fig. 5 Nyquist plots of CNTs/rGO composites with different mass ratios at 10 mV (ac) superimposed on 0 V (dc) vs. Ag/AgCl with frequencies ranged from 100 kHz to 0.2 Hz, measured in 0.1 M Na2SO4 solutions. | |
Table 2 Equivalent circuit parameters obtained from Nyquist plots by fitting
Parameter |
rGO |
30% CNTs/rGO |
60% CNTs/rGO |
R1 (ohm) |
20.37 |
7.872 |
7.154 |
C2 (F) |
0.000128 |
0.000546 |
0.00111 |
R3 (ohm) |
3.93 |
0.547 |
0.357 |
W4 (S s(−1/2)) |
0.0254 |
0.311 |
0.376 |
2.2 Electro-Fenton reaction for decolouration of MB
2.2.1 CNT loadings. The dosage of the CNTs is important to enhance conductivity of the rGO aerogel which would increase efficiency of the electro-Fenton reaction. Fig. 6 shows that the decolouration of MB was enhanced with increase loading of CNTs. The decolouration performance of the aerogel samples increased with the CNT content, in which the 60%-CNTs/rGO aerogel exhibited the highest MB decolouration which can be due to the higher conductivity and surface area. Higher CNTs as a filler would lead to the higher and faster generation of ˙OH which was resulted from the increase of active site, surface area and conductivity.
|
| Fig. 6 Decolouration of methylene blue in the electro Fenton system with different CNTs concentration as rGO electrode filler. Conditions: pH 3, current 80 mA and 0.1 M Na2SO4. | |
As the reaction proceeds, MB colour faded indicate decrease of MB concentration. This can be described from collapse of MB molecule structure or chromoforic destruction. Decomposition of H2O2 plays a vital role in the generation of ˙OH radicals which are the main oxidizing agent of MB solution. The decomposition of MB which can be described by the breaking of the N–CH3, C–N, C–S and CH3 bonds to form intermediates that will be further oxidized into form CO2, H2O, Cl−, SO4− and NO3−.33
2.2.2 pH. The pH of solution is well known as an important factor in Fenton reaction. Acidic medium was preferred as basic pH adversely affects the overall treatment efficiency.34 In acidic medium, more protons are available in the solution that can promote the conversion of dissolving oxygen into H2O2.35 As shown in Fig. 7, pH 3 gives 100% decolouration in 60 minutes of treatment as compared to pH 5 and 7 which did not achieve 100% decolouration and have reached a plateau at 80 and 90 minutes, respectively. At high pH, Fe3+ ions would precipitate to form amorphous Fe(OH)3 and deposit on the electrode surface, resulting in less Fe2+ to be regenerated for Fenton reaction.36
|
| Fig. 7 Effect of different pH on decolouration of MB using 60%-CNTs/rGO aerogel as electrode. Conditions: current 80 mA and 0.1 M Na2SO4. | |
2.2.3 Current density. Applied current density acts as the driving force of electron transfer and corresponds to the rate of H2O2 generation in electro-Fenton system.37 Fig. 8 shows that the greater the current applied, the higher the rate of MB decolouration. The increase in current not only helped in the production of ˙OH radicals, but also increase the regeneration rate of Fe2+ from Fe3+, resulting in higher efficiency of Fenton reaction.36
|
| Fig. 8 Effect of different current on decolouration of MB using 60%-CNTs/rGO aerogel. Conditions: pH 3 and 0.1 M Na2SO4. | |
2.2.4 Electrolyte concentration. Fig. 9 shows the effect of Na2SO4 concentration on the decolouration performance of the 60%-CNTs/rGO aerogel. In general, higher Na2SO4 favored the decoloration of MB. From Fig. 4b, 0.2 M Na2SO4 gives higher current density compared to 0.1 M Na2SO4. However, 0.1 M Na2SO4 was chosen as the optimum condition as there is not much different in term of the decoloration rate for 0.1 M and 0.2 M of Na2SO4. Besides, the presence of excess sulphate might cause scavenging effect to hydroxyl radicals which would lower the treatment efficiency although 0.2 M Na2SO4 gives a better current density.37 Lower decolouration efficiency using 0.075 M and 0.05 M Na2SO4 may be due to the insufficient conductivity of the solution for the electron transfer.
|
| Fig. 9 Effect of different electrolyte concentrations on decolouration of MB using 60% CNTs/rGO aerogel. Conditions: pH 3 and current 80 mA. | |
2.2.5 H2O2 generation vs. dissolved oxygen content. Fig. 10 shows the relationship between H2O2 generated and the dissolved oxygen content under optimum electro-Fenton reaction parameters using the 60%-CNTs/rGO aerogel. The H2O2 concentration increased linearly up to 80 minutes reached a plateau over time with the decrease of DO content from 8.19 mg L−1 to 6.47 mg L−1 at 20 minutes. The significant decrease in DO content at the first 20 minutes of reaction suggests the necessity of oxygen for the generation of H2O2. No further increase in DO content although the aeration was continuously performed, suggesting that the oxygen supplied has been consumed by the electro-Fenton process.
|
| Fig. 10 H2O2 generation on electro Fenton system using 60%-CNTs/rGO aerogel. Conditions: pH 3, current 80 mA and 0.1 M Na2SO4. | |
2.2.6 Reusability lability of CNTs/rGO aerogel electrode. From an practical application perspective, electrode stability must be considered. The reusability of electrodes was evaluated by conducting six consecutive cycles of MB treatment (see Fig. 11). It can be seen that the decolouration performance of the 60%-CNTs/rGO aerogel was maintained at 80% after the six consecutive runs. The 30%-CNTs/rGO shows lower efficiency in decolouration for the consecutive treatment cycles, which can be attributed to the lower conductivity of the aerogel. Breakdown of rGO electrode occurred right after the first treatment cycle as the result of weak bonding between the rGO sheets. This observation further proven that the addition of CNTs can significantly improve mechanical stability and reusability of the aerogels.
|
| Fig. 11 Reusability tests for electro-Fenton decolouration of MB using rGO, 30%-CNTs/rGO and 60%-CNTs/rGO aerogels. Conditions: pH 3, current 80 mA, and 0.1 M Na2SO4. | |
2.2.7 Electro-Fenton reaction for decolouration of POME. Fig. 12 shows the decoloration of POME using 60%-CNTs/rGO aerogel. Fig. 12a shows the decolouration of POME using the 60%-CNTs/rGO aerogel conducted using the optimum parameters obtained from the experiments on MB, i.e., pH 3, 80 mA, and 0.1 M Na2SO4. After 40 minutes of treatment, colour intensity (PtCo) of the POME was reduced from 1054 to 320 PtCo, which is equivalent to approximately 70% of decolouration. Fig. 12b shows that decolouration capability of the aerogel was maintained around 70% after eight consecutive treatment runs which was on par with the initial run which is at 73.34% of POME decolouration, indicating the good reusability of the aerogel.
|
| Fig. 12 Treatment of POME using 60%-CNTs/rGO aerogel. (a) Decolouration of POME and (b) reusability test for electro-Fenton decolouration of POME. Conditions: pH 3, current 80 mA, and 0.1 M Na2SO4, and 60 minutes for each cycle. | |
Table 3 presents the results of TOC and COD of POME before and after the electro-Fenton reaction. TOC and COD of the POME was reduced 47.63% and 58.1% respectively after 60 minutes of electro-Fenton reaction using the 60%-CNTs/rGO aerogel electrode. The decrease in TOC was caused by demineralization of dissolved organic compounds in the POME water and carbon dioxide by ˙OH radicals generated.
Table 3 Total organic carbon (TOC) and chemical oxygen demand (COD) of POME before and after treatment using 60%-CNTs/rGO aerogel via electro-Fenton reaction. Conditions: pH 3, current 80 mA, 0.1 M Na2SO4
|
Initial (mg L−1) |
Final (mg L−1) |
Percentage removal (%) |
TOC |
105 |
44 |
47.6 |
COD |
401 |
210 |
58.1 |
3 Conclusions
This study described the preparation and utilization of CNTs/rGO aerogel as a electrode for electro-Fenton reaction. The 60%-CNTs/rGO aerogel showed good decolouration performance towards MB and POME as compared to the neat rGO due to its high surface area, porosity and bulk conductivity. It is also found that the 60%-CNTs/rGO aerogel can be reused for more than six cycles of electro-Fenton reaction to decolorize MB and POME without significant reduction in performance.
Conflicts of interest
There are no conflicts of interest to declare.
Acknowledgements
The authors would like to thank the Centre of Research and Instrumentation (CRIM), UKM for the research grant GUP-2018-159 provided.
Notes and references
- D. Kanakaraju, B. D. Glass and M. Oelgem, J. Environ. Manag., 2018, 219, 189–207 CrossRef CAS PubMed.
- D. B. Miklos, C. Remy, M. Jekel, K. G. Linden and J. E. Drewes, Water Res., 2018, 139, 118–131 CrossRef CAS PubMed.
- Y. Lin, S. Wu, C. Yang, M. Chen and X. Li, Appl. Catal., B, 2019, 245, 71–86 CrossRef CAS.
- Y. Lin, S. Wu, X. Li, X. Wu, C. Yang, G. Zeng, Y. Peng, Q. Zhou and L. Lu, Appl. Catal., B, 2018, 227, 557–570 CrossRef CAS.
- S. Wu, H. Li, X. Li, H. He and C. Yang, Chem. Eng. J., 2018, 353, 533–541 CrossRef CAS.
- S. Wu, H. He, X. Li, C. Yang, G. Zeng, B. Wu, S. He and L. Lu, Chem. Eng. J., 2018, 341, 126–136 CrossRef CAS.
- Q. Wang, S. Zhou, S. Xiao, F. Wei, X. Zhao, J. Qu and H. Wang, RSC Adv., 2018, 8, 14775–14786 RSC.
- X. Wang, K. Zhu, X. Ma, Z. Sun and X. Hu, RSC Adv., 2018, 8, 19971–19978 RSC.
- Q. Peng, Z. Zhang, Z. Huang, W. Ren and J. Sun, RSC Adv., 2014, 4, 60168–60175 RSC.
- L. Bounab, O. Iglesias, E. González-Romero, M. Pazos and M. Ángeles Sanromán, RSC Adv., 2015, 5, 31049–31056 RSC.
- S. Qiu, L. Yu, D. Tang, W. Ren, K. Chen and J. Sun, Ind. Eng. Chem. Res., 2018, 57, 4907–4915 CrossRef CAS.
- B. Hou, B. Ren, R. Deng, G. Zhu, Z. Wang and Z. Li, RSC Adv., 2017, 7, 15455–15462 RSC.
- T. X. H. Le, T. Van Nguyen, Z. Amadou Yacouba, L. Zoungrana, F. Avril, D. L. Nguyen, E. Petit, J. Mendret, V. Bonniol, M. Bechelany, S. Lacour, G. Lesage and M. Cretin, Chemosphere, 2017, 172, 1–9 CrossRef CAS PubMed.
- C. Zhang, M. Zhou, G. Ren, X. Yu, L. Ma, J. Yang and F. Yu, Water Res., 2015, 70, 414–424 CrossRef CAS PubMed.
- Y. Wang, Y. Liu, K. Wang, S. Song, P. Tsiakaras and H. Liu, Appl. Catal., B, 2015, 165, 360–368 CrossRef CAS.
- S. O. Ganiyu, T. X. Huong Le, M. Bechelany, G. Esposito, E. D. Van Hullebusch, M. A. Oturan and M. Cretin, J. Mater. Chem. A, 2017, 5, 3655–3666 RSC.
- W. Ren, Q. Peng, Z. Huang, Z. Zhang, W. Zhan, K. Lv and J. Sun, Ind. Eng. Chem. Res., 2015, 54, 8492–8499 CrossRef CAS.
- H. Zhao, L. Qian, X. Guan, D. Wu and G. Zhao, Environ. Sci. Technol., 2016, 50, 5225–5233 CrossRef CAS PubMed.
- J. Hu, J. Sun, J. Yan, K. Lv, C. Zhong, K. Deng and J. Li, Electrochem. Commun., 2013, 28, 67–70 CrossRef CAS.
- X. Wang, W. Guo, Y. Zhu, X. Liang, F. Wang and P. Peng, Appl. Sci., 2018, 8, 2101 CrossRef.
- J. H. Kim, J. Y. Hwang, H. R. Hwang, H. S. Kim, J. H. Lee, J. W. Seo, U. S. Shin and S. H. Lee, Sci. Rep., 2018, 8, 1–11 CrossRef PubMed.
- F. Schütt, S. Signetti, H. Krüger, S. Röder, D. Smazna, S. Kaps, S. N. Gorb, Y. K. Mishra, N. M. Pugno and R. Adelung, Nat. Commun., 2017, 8, 1–10 CrossRef PubMed.
- S. A. Shamsuddin, M. N. Derman, U. Hashim, M. Kashif, T. Adam, N. H. A. Halim and M. F. M. Tahir, AIP Conf. Proc., 2016, 1756, 090002 CrossRef.
- Q. Yang, S. K. Pang and K. C. Yung, J. Power Sources, 2016, 311, 144–152 CrossRef CAS.
- J. Shen, A. Liu, Y. Tu, G. Foo, C. Yeo, M. B. Chan-Park, R. Jiang and Y. Chen, Energy Environ. Sci., 2011, 4, 4220–4229 RSC.
- H. He, Y. Cheng, C. Yang, G. Zeng, C. Zhu and Z. Yan, J. Environ. Sci., 2017, 54, 135–141 CrossRef PubMed.
- M. N. Mohd Zubir, A. Badarudin, S. N. Kazi, H. Nay Ming, R. Sadri and A. Amiri, J. Dispersion Sci. Technol., 2016, 37, 1395–1407 CrossRef CAS.
- N. M. Huang, H. N. Lim, C. H. Chia, M. A. Yarmo and M. T. Muhammad, Int. J. Nanomed., 2011, 6, 3443–3448 CrossRef CAS PubMed.
- S. Pei and H. M. Cheng, Carbon, 2012, 50, 3210–3228 CrossRef CAS.
- M. Bowman, J. Chem. Educ., 1949, 1, 103–104 CrossRef.
- W. Yang, Y. Chen, J. Wang, T. Peng, J. Xu, B. Yang and K. Tang, Nanoscale Res. Lett., 2018, 13, 181 CrossRef PubMed.
- B. Hashwan, S. Saeed, M. F. Fatin, A. R. Ruslinda, M. K. Md Arshad, U. Hashim and R. M. Ayub, Appl. Mech. Mater., 2015, 754–755, 1156–1160 Search PubMed.
- Q. Wang, S. Tian, J. Cun and P. Ning, Desalin. Water Treat., 2013, 51, 5821–5830 CrossRef CAS.
- A. Babuponnusami and K. Muthukumar, International Journal of Advance Innovations, Thoughts & Ideas, 2017, 3, 439–451 Search PubMed.
- E. Alfaya, O. Iglesias, M. Pazos and M. A. Sanromán, RSC Adv., 2015, 5, 14416–14424 RSC.
- M. Radwan, M. Gar Alalm and H. Eletriby, Journal of Water Process Engineering, 2018, 22, 155–162 CrossRef.
- H. He and Z. Zhou, Crit. Rev. Environ. Sci. Technol., 2017, 1–32 Search PubMed.
|
This journal is © The Royal Society of Chemistry 2019 |
Click here to see how this site uses Cookies. View our privacy policy here.