DOI:
10.1039/C9SC90118C
(Correction)
Chem. Sci., 2019,
10, 6390-6392
Correction: Monitoring metal–amyloid-β complexation by a FRET-based probe: design, detection, and inhibitor screening
Received
20th May 2019
, Accepted 20th May 2019
First published on 17th June 2019
Abstract
Correction for ‘Monitoring metal–amyloid-β complexation by a FRET-based probe: design, detection, and inhibitor screening’ by Hyuck Jin Lee et al., Chem. Sci., 2019, 10, 1000–1007.
In their original Edge article, the authors reported a FRET-based probe, A-1, composed of amyloid-β1-21 (Aβ1-21) with a pair of FRET donor and acceptor and used this for monitoring Zn(II)–Aβ complexation with a turn-on FRET signal and identifying inhibitors against Zn(II)–Aβ interaction. The authors provided the methods and procedures for experiments, however, more detailed experimental information is provided here to improve clarity for the readers. In this Correction, the authors have provided information about selecting the concentrations of the probe and Zn(II) and buffer, and detecting a change in FRET depending on the length (sequence) of the probe, along with more discussion on the effects of inhibitors on the FRET of Zn(II)-added A-1 and the purpose of designing the probe.
The additional information and references are provided below. The Royal Society of Chemistry apologises for these errors and any consequent inconvenience to authors and readers.
Results and discussion
Selection of experimental conditions for FRET measurements
To noticeably monitor the FRET signal of A-1 upon Zn(II) binding, the conditions for (i) less and slower aggregation of A-1 and (ii) its unfolding state prior to treatment with Zn(II) are required. Thus, a range of nM concentrations of A-1 were applied to measure its FRET signal. Based on Zn(II) titration experiments, the concentration of Zn(II) for fluorescence measurements was chosen (Fig. S3 in the original article). The fluorescence intensity of A-1 (500 nM) at 420 nm was enhanced upon titration of Zn(II) and saturated at ca. 100 μM Zn(II). Taken together, a range of nM concentrations of A-1 (250–500 nM) and 100 μM Zn(II) were used for our experiments. Note that if 5 μM A-1 was used for the experiments, we observed that ca. 10 μM Zn(II) (2 equiv. of A-1) was required to give an maximum increase in its FRET signal (Fig. S3 in the original article), however, the probe aggregates faster at this concentration, relative to at a nM concentration. In addition, based on the binding affinity of Zn(II) to full length Aβ40 or Aβ42 (ca. nM to μM depending on the experimental conditions),1 our titration data obtained using 500 nM or 5 μM A-1 are expected. Moreover, the solvent could influence the folding state and FRET response of A-1. Therefore, four criteria were considered to select a suitable buffer for our measurements: (i) the solubility of A-1, (ii) the aggregation rate of A-1, (iii) no other divalent metal ions being present, and (iv) a significant change in the fluorescence of A-1 by Zn(II) binding. Following these criteria to select the best solution for our experiments, we examined the change in the FRET signal of A-1 upon treatment of Zn(II) in three different solvents; (i) ddH2O, (ii) 100 mM Tris (pH 7.0), and (iii) 10% Dulbecco’s Phosphate-Buffered Saline (DPBS that does not contain other divalent metal ions; pH 7.3) (Fig. 1). When A-1 was in ddH2O or Tris buffer, the FRET signal of A-1 with Zn(II) was not significantly changed compared to that under Zn(II)-free conditions. The FRET signal of A-1, however, increased by >ca. 2-fold upon treatment with Zn(II) in 10% DPBS. Using our criteria, 10% DPBS (the buffer solution without other divalent metal ions) was chosen for our experiments. Note that we cannot rule out the possibility of forming Zn(II)–buffer (phosphate) complexes and a ternary complex of Zn(II), buffer, and A-1, similar to previously reported studies,2,3 which may affect the FRET signal of A-1.
|
| Fig. 1 FRET signals of A-1 with addition of Zn(II) under various conditions. Emission spectra of A-1 with (green) and without (black) Zn(II) in ddH2O (left), 100 mM Tris (middle), and 10% DPBS (right). Conditions: [A-1] = 500 nM; [ZnCl2] = 100 μM; λex = 280 nm; room temperature. | |
Change in FRET depending on the length of FRET model peptides
Since FRET occurs through the long-range dipole–dipole interaction between donors and acceptors, it is sensitive to the orientation and distance of the FRET pair.4,5 When the FRET of the model peptides with different lengths was monitored, Aβ1-21 (A-1) only showed a strong increase in FRET upon Zn(II) addition, but Aβ1-17 and Aβ1-18 indicated a very small increase in FRET in the presence of Zn(II) in 10% DPBS (Fig. 2a). In the case of Aβ1-22, the probe showed a decrease in fluorescence upon Zn(II) addition. In addition, Aβ1-19 exhibited no FRET signal but presented a noticeable intensity in fluorescence at ca. 370 nm corresponding to Trp fluorescence. Note that the FRET signal of the model peptides was observed in 10% DPBS; however, it was not shown in 10% PBS (Fig. 2). These data support that A-1 was the model peptide suitable for observing FRET upon Zn(II)-mediated conformational change in 10% DPBS.
|
| Fig. 2 Change in Zn(II)-dependent fluorescence with the FRET model peptides (Aβ1-17, Aβ1-18, Aβ1-19, and Aβ1-22). (a) Fluorescent responses of Aβ1-17, Aβ1-18, Aβ1-19, and Aβ1-22 to Zn(II) in 10% DPBS. (b) Fluorescence behavior of Aβ1-17 and Aβ1-18 with and without Zn(II) in 10% PBS. Conditions: [FRET model peptide] = 500 nM; [Zn(II)] = 100 μM. | |
Variation of the FRET signal of Zn(II)-added A-1 upon incubation with a chelator
Considering the general properties of fluorophores, the change in λmax upon Zn(II) coordination to A-1 suggests that the microenvironment of the fluorescent acceptor probably becomes hydrophobic. The addition of metal chelator, L2-b (structure shown in Table S1 in the original article), changed the fluorescence intensity of the fluorescent acceptor; however, it did not vary λmax of the emission. This implies that the microenvironment of the fluorescent acceptor does not significantly change, and Zn(II) is still coordinated to A-1. Whereas, the treatment of a well-known metal chelator, EDTA (structure shown in Table S1 in the original article), altered λmax of the emission, which became the same as that of the peptide itself with a decrease in the fluorescence intensity, suggesting that the microenvironment of the fluorescent acceptor was similar to that of A-1 itself showing no significant FRET. Since EDTA is a strong metal chelator, it could extract Zn(II) from A-1. Moreover, since A-1 aggregates with and without Zn(II), a heterogeneous population of its conformations upon incubation in solution may be another factor that influences the chelators’ interaction towards the Zn(II)-added probe and affects the FRET signal. Together, these properties may explain the increased fluorescence intensity compared to that of A-1.
The purpose of designing A-1
A-1 was designed as an in vitro probe capable of Zn(II) binding showing FRET. This probe is composed of the metal binding site in Aβ; thus, it can be a model for Zn(II)–Aβ upon Zn(II) binding, and can be used for identifying potential inhibitors against Zn(II)–Aβ interaction in an efficient and effective manner. The inhibitors determined by Zn(II)–A-1 based on FRET could be further evaluated in biological systems to confirm their biological use as inhibitors against Zn(II)–Aβ complexes.
References
- M. G. Savelieff, G. Nam, J. Kang, H. J. Lee, M. Lee and M. H. Lim, Chem. Rev., 2019, 119, 1221–1322 CrossRef CAS PubMed.
- A. Staszewska, E. Kurowska and W. Bal, Metallomics, 2013, 5, 1483–1490 RSC.
- I. Marszalek, W. Goch and W. Bal, Inorg. Chem., 2018, 57, 9826–9838 CrossRef CAS PubMed.
-
J. Lakowicz, Principles of Fluorescence Spectroscopy, Springer, New York, 1999 Search PubMed.
- E. A. Jares-Erijman and T. M. Jovin, Nat. Biotechnol., 2003, 21, 1387–1395 CrossRef CAS PubMed.
Footnote |
† These authors contributed equally to this work. |
|
This journal is © The Royal Society of Chemistry 2019 |
Click here to see how this site uses Cookies. View our privacy policy here.