Effects of gas temperature gradient on the accuracy of single-particle inductively coupled plasma (SP-ICP) measurements

Abstract

Double-viewing-position single-particle inductively coupled plasma-optical emission spectrometry (DVP-SP-ICP-OES) has been used to investigate the effects of temperature gradient in the ICP central channel on SP-ICP intensity. The correlation plot of the intensities of individual Yb2O3 particles at observation positions of 8.5 and 19.5 mm above the load coil shows extensive scattering. The lack of correlation is probably due to the relatively large gradient of ICP gas temperature in the radial direction at the lower observation position. The hypothesis is supported by the results of SP-ICP-OES measurements using a sheath gas device to confine the particles in either the center or the outer region of the ICP central channel. Particles in the two regions show distinct patterns in the correlation plot. Computer simulation shows that the amount of heat required to bring the Yb2O3 particles to boiling is substantial and the duration of the heat transfer process is not negligible but increases with particle mass. As a result, large particles have a relatively small degree of vaporization (DOV) at low observation positions where SP-ICP-OES intensity is not proportional to particle mass. The calibration curve is concave. Particle size determination by SP-ICP measurement at low observation positions, therefore, can be erroneous. The article concludes with a simulation of particle vaporization with a wide range of particle sizes and boiling points. A quick lookup graph of the observation position for DOV = 70% versus particle diameter is provided for the selection of the initial observation position for SP-ICP measurement.

Graphical abstract: Effects of gas temperature gradient on the accuracy of single-particle inductively coupled plasma (SP-ICP) measurements

Supplementary files

Article information

Article type
Paper
Submitted
11 Feb 2021
Accepted
26 Apr 2021
First published
27 Apr 2021

J. Anal. At. Spectrom., 2021,36, 1261-1271

Effects of gas temperature gradient on the accuracy of single-particle inductively coupled plasma (SP-ICP) measurements

K. Chun and W. Chan, J. Anal. At. Spectrom., 2021, 36, 1261 DOI: 10.1039/D1JA00053E

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements