Jeyaraj
Belinda Asha
a,
Murugan
Karthik
ab and
Palaniswamy
Suresh
*a
aSupramolecular and Catalysis Lab, Department of Natural Products Chemistry, School of Chemistry, Madurai Kamaraj University, Madurai – 625021, India. E-mail: suresh.chem@mkuniversity.ac.in; ghemistry@gmail.com; Tel: +91 9790296673
bDepartment of Chemistry, National Institute of Technology, Tiruchirappalli, India
First published on 29th March 2021
Ruthenium is a vital transition metal widely employed in diverse applications from medicinal to material applications. Though ruthenium has been positioned as safe and relatively less toxic than other metals, continuous exposure will cause undesirable effects. Due to the constantly increasing usage of ruthenium, a simple and straightforward detection methodology is immediately necessary. In the present study, a covalently functionalized graphene oxide derived chemosensor has been developed to detect Ru(III) under a complete aqueous medium. For this, graphene oxide (GO) is covalently functionalized on the edge carboxylic acid group with 2-(bis(pyridine-2-ylmethyl)amino)ethan-1-ol (PAE) through esterification, followed by further grafting on the basal plane with a dansyl fluorophore motif through a silyloxy propyl linkage. Each functionalization has been designed to create a feasible pathway for a Förster Resonance Energy Transfer (FRET) donor and acceptor energy transfer, where the metal-binding site is introduced through esterification and the signalling unit by the dansylation process. When exploring the application of the newly prepared GOPND carbonaceous material, a selective fluorescence quenching response has been observed with Ru(III) in an aqueous medium, which is utilized for the detection of Ru(III). A GOPND probe showed high selectivity towards Ru(III) over the presence of other common metal ions with a lower detection limit of 15 nM. The origin of this ‘turn-off’ sensing response is explained through the presence of both the bis(pyridyl) probe and the dansyl fluorophore in close proximity on GO, which facilitates the energy transfer. The specific turn-off fluorescence response of the GOPND with Ru(III) ions is rationalized through the FRET mechanism.
Though the photophysical nature of GO has been widely studied as a quencher, under certain environments and in the presence of other external stimuli, the luminescent nature of GO was enhanced. Such an increase in the PL behavior of GO and its physisorbed or chemically modified derivatives have been used for diverse sensing applications.20–23 Recently, the chemosensor application of GO-derived materials has been continuously explored in the detection of heavy metal ions24 and even for f-block elements,25 organophosphorus pesticides,26 and ATP and GTP monitoring in living cells.27 A maximum number of reports have focused on the quenching of the PL through either blocking or unblocking of the graphitic surface of GO through physisorbed molecules over the surface28 or decorated nanoparticles.29 Recently, the detection30,31 and removal of chromium(IV)32 ions was proposed using a graphene-based system. In GO-based sensors, the non-covalently modified system has shown excellent response; but, indeed, none of the studies disclosed their stability or reproducibility for further applications, which strongly questions the reliability of such sensor materials. There is a lack of adequate studies on the stability of non-covalently modified GO-based sensors. With this ambiguity, in the present work, we have designed and developed a turn-off fluorescence sensor through covalent modification of both the edge carboxyl group and the basal plane of GO. A turn-off sensor material has been designed and developed based on the fluorescence resonance energy transfer between the coordinated metal site and a luminescent probe attached on GO, where an organic motif 2-bis(pyridine-2-ylmethyl)amino)ethan-1-ol (PAE) was used as a metal coordinating site, which was covalently attached to GO through Steglich33 esterification and a dansyl motif as a fluorescence probe was grafted on the basal plane through a propyl silyloxy linkage. This sensing material is designed to enhance benignity and also to detect ruthenium metal in an aqueous medium. With such a perspective, GOPND has been designed with a FERT-based sensing mechanism.
Ruthenium is a rare and heavy transition metal which has diverse attractive applications from medicine to material applications. Ruthenium has been found to be a potential alternative to platinum in medicinal applications and is used as an immunosuppressant34 and dental alloy,35 as an anti-Alzheimer's agent,36 in microbial antibiotic production for Malaria, Chagas disease, septic shocks, and cancer treatment.34 Ruthenium-derived drugs are gaining more attention in clinical application owing to their low toxicity.34,36 Meantime, ruthenium is an inevitable candidate in electronics due to its excellent bandgap energies; it has been employed in semiconductor and thermoelectric applications.37 In contemporary research on energy harvesting from renewable resources, notably from sunlight, the dye-sensitized solar cell has played a significant role.38 The redox properties of ruthenium are effectively utilized to enhance the efficiency of light energy harvesting.38,39 On the other hand, ruthenium plays an inevitable role in synthetic organic chemistry as a potential catalyst. After the 2005 Noble prize was awarded for olefine metathesis to form a C–C bond,40–42 the demand for ruthenium-derived catalysts has increased exponentially for synthesizing active pharmaceutical ingredients. Besides, reactions such as Fischer–Tropsch43 and Boulton–Katritzky44 also utilize ruthenium as a catalyst. In asymmetric synthesis, ruthenium-derived chiral catalysts are employed to fine-tune the enantioselectivity.45 However, it is challenging to remove and quantify the deeply colored ruthenium by-products from the desired product.46 Though ruthenium has found numerous applications and plays a pivotal role in human welfare, its fate after usage has not been determined correctly. Indeed, exposure to, extensive use of, and improper disposal of ruthenium ions could also cause adverse effects in the environment, because they exhibit various forms of toxicity and lead to health issues like the platinum group elements (PGEs).47–51 The maximum permissible intake of Ru(III) or related transition metals in oral dosage and parenteral dosage in pharmaceutical products per day are 10 μg g−1 and 1.0 μg g−1 respectively.47–53 Apart from its extensive applications, in general, most ruthenium-containing compounds are considered to be toxic because they can deeply stain the skin, and the ingested metal may be retained strongly in the bones.34 Excess exposure to or intake of ruthenium is harmful and may cause corrosion to the respiratory tract, eyes, and digestive tract.54 The toxic nature of ruthenium is also taken quite seriously since it has a mutagenic effect in normal cells.54–56 A more extended stay of a ruthenium complex in the lungs results in metastatic tumours.54,55 To detect the existence of ruthenium ions, routine analytical techniques such as atomic absorption (AAS)57 and inductively coupled plasma-mass spectrometry (ICP-MS) are used.58 However, they involve expensive instrumental analysis and a rigorous sample preparation method. To the best of our knowledge, there has been no study on the development of a chemosensor for the detection of ruthenium except for a few reports. A colorimetric methodology was reported using per-6-amino-β-cyclodextrin as a supramolecular host to detect Ru(III).59 A few fluorescence detectors, such as porphyrin macrocyclics,60 fluorescein derivatives through the oxidative process,61 CdTe quantum dots62 and a 3D luminescent indium–organic framework63 and functionalized phenanthridine derivatives, have been used to detect Ru(III)64 and an aggregation-induced emission-based probe for Ru(III) has also been reported.65 Though numerous metal detecting methodologies and chemosensors have continuously evolved for several common metal ions, very few sensing methods have been developed for the biologically and industrially essential metal ruthenium. Indeed, a suitable and selective detection methodology is an immediate need. A reliable and straightforward sensing technique must be designed to detect such pharmaceutically cum industrially versatile metal ions from the environment and biological systems.
We have developed a “turn-off” fluorescence sensing strategy for the rapid and selective detection of ruthenium(III) in an aqueous medium. Based on hard acid and soft base (HSAB) theory, a bis(pyridine) motif as a metal coordination site, and dansyl motifs attached to GO as a fluorescent probe, a heterogeneous fluorescence sensing probe has been designed to operate through a FRET sensing mechanism. With this fundamental design, when ruthenium(III) coordinates with GOPND and under subsequent excitation, an excited state energy transfer takes place through FRET from ruthenium(III) coordinated bis(pyridyl) to dansyl attached on the basal plane of GO, and a simple turn-off type fluorescence sensing process takes place. The calculated LOD is also relatively lower than previously reported values. Furthermore, unlike homogenous chemosensors, heterogeneous chemosensors will strongly support scaling up and the design of materials for real-time sensor applications.
![]() | ||
Fig. 1 Spectroscopic analysis of GO, GOP, GOPN, and GOPND, (i) elemental analysis, (ii) FTIR, (iii) Raman spectra, (iv) powder X-ray diffraction (P-XRD) pattern. |
Next, the covalent functionalization was characterized using Fourier transform infrared (FT-IR) spectroscopy analysis; this is an elegant tool to analyze the chemical functionalization of graphitic materials. The complete covalent modification and the formation of GOPND are confirmed through the meticulous analysis of the FT-IR spectra and a comparison with its precursors (Fig. 1(ii)). The presence of a peak at 1722 cm−1 represents the CO stretching of the ester linkage and indicates the functionalization of the bis(pyridyl) motif on the edge carboxylic groups of GO. Added to that, the stretching at 1575 cm−1 of the aromatic C
C stretching shows the presence of the pyridyl rings of the bis(pyridyl) motif. Compared to GO, new peaks that appeared in the range of 1032 cm−1 to 1122 cm−1 corresponding to the Si–O and Si–O–C stretching frequencies confirmed the functionalization of aminopropyl on the basal plane of GO through silyloxy linkage. Further, the peak at 3377 cm−1 of the primary amine in GOPN shifted to 3405 cm−1 in GOPND, corresponding to the stretching frequency of the secondary amine, demonstrating the functionalization of dansyl chloride. Further peaks at 1390 cm−1 of sulfonyl, 2491 cm−1 of S
O and N–H stretching frequencies, and 1473 cm−1 of the symmetric bending stretching frequency of the methyl group support the functionalization of dansyl motifs with GOPN. The peaks at 785 cm−1 and 1520 cm−1 of naphthalene stretching frequencies also strongly ascertain the presence of the dansyl motif in the covalently functionalized GOPND. The peaks 2669 cm−1 and 2928 cm−1 of alkyl stretching frequencies show the propyl linkage between the dansyl motif and the graphitic plane of GOPND. Furthermore, the peaks at 1645 cm−1 and 1210 cm−1 of aromatic C
C and C–C ascertain the presence of the graphitic plane.
FT-Raman provides unique information about the graphitic material, such as the degree of functionalization and defects derived from the functionalization. All the as-prepared materials, GOP, GOPN, and GOPND, were analyzed by FT-Raman, and the results are presented in Fig. 1(iii). From the Raman spectra, the existence of sp2 and sp3 hybridization and the corresponding change in the D/G ratio of derivatized GO materials reveal functionalization. For GO and GOP, the calculated D/G ratios are 0.83 and 0.84, respectively, and ID/IG are 1 and 1.01, respectively, which indicates that no notable change occurs on the GO basal plane. Similar results continued on further functionalized GOPN and GOPND. The D/G ratios of GOPN and GOPND are 0.83 and 0.84, respectively, and the ID/IG ratios are 1.03 and 1.02, respectively. The analysis of both D/G and ID/IG ratios revealed no significant changes apart from a marginal increase in the peak intensities. This discloses that the esterification and the silylation on the basal plane of GO did not affect the hybridization of the carbon on the graphitic domain because the silyloxy propyl functionalization takes place on the existing hydroxyl and epoxide functional groups. The FT-IR analysis also supports this observation through the unaffected CC peaks at 1626 cm−1.
Further, to verify the crystalline nature of the as-prepared GOP, GOPN, and GOPND, they were subjected to powder X-ray diffraction (PXRD) analysis. However, the PXRD pattern does not provide any remarkable information regarding the functionalization and formation of GOPND material. In general, GO shows two characteristic broad peaks at 2θ values of 12.2° and 41.6° corresponding to the (001)70 and (100)71 reflection planes, respectively. In the case of GOPND after covalent modification, the same two planes are retained, whereas the (001) planes are slightly shifted to 12.4°. However, compared to GO and GOP, the peaks get broader, which affirms that the amorphous nature has been maintained even after functionalization with silyloxy bonding. Indeed, the interlayer spacing of GO could be tuned through the covalent functionalization. The calculation of the interlayer spacing of GOPND using the Bragg's equation showed an intriguing enhancement in interlayer spacing of 2.3 nm from 0.725 nm with a slight decrease in 2θ (001) = 12.779 to 12.43, which ascertained the covalent functionalization of GO and resulted from the formation of GOPND. Although all the above characterizations gave an understanding regarding the formation of GOPND from GO, finally, to unambiguously understand the covalent functionalization and confirm the formation of GOPND, X-photoelectron spectroscopy studies (XPS) were carried out (Fig. 2). When analyzing the XPS spectrum of GO, only two significant peaks of C 1s (286.4 eV) and O 1s (533 eV) were present. After covalent modification, in the XPS spectrum of GOPND, in addition to the enhanced intensity of C 1s and O 1s, new additional peaks N 1s, S 2s, and 2P and Si 2p appeared.
![]() | ||
Fig. 2 XPS survey spectrum of GOPND (a). Deconvoluted XPS spectra of C 1s (b), N 1s (c), O 1s (d), Si 2p (e), S 2s (f) and S 2p (g). |
The deconvoluted C 1s spectrum at 284 eV of GOPND gives three peaks at 283.6 eV of sp2 of C–C72 of the graphitic basal plane, at 284.7 eV73 of the aromatic C–C from benzene and naphthyl rings, and at 286.7 eV of the C–O from the ester carboxylate.74 The peak at 531.3 eV corresponds to O 1s, which validates the presence of ester carbonyl (CO).75 Next, deconvoluting the N 1s peak at 399 eV gives two peaks at 398.9 eV and 401 eV of the pyridinic nitrogen of the bis(pyridyl) unit and the ‘C–N’ of the N,N-dimethyl unit from the dansyl motif, respectively. These nitrogen peaks confirmed the covalent attachment of the bis(pyridyl) and dansyl groups to GO. Further, the presence of two peaks at 231 eV and 167.6 eV corresponds to the sulfur 2s and 2p binding energy present as a sulfone group in the dansyl motif. Finally, the peak at 101.5 eV proves the silyloxy functionalization on the GO basal plane and is further deconvoluted to give two peaks at 101.2 eV of Si–O/Si–O–C76 and 101. 9 eV of Si–C.77 The above-detailed observation from the XPS survey strongly confirms the formation of GOPND.
SEM images usually demonstrate a sheet-like morphology for GO; the same has been observed here, but in the case of GOP (Fig. 3(b)), certain voids can be detected due to the covalent modification. The SEM images show a crushed and pulverized form, which reveals that the functionalization may introduce a lot of defects over the surfaces. The sheets were not uniform; there are a lot of pits found on the surface due to its surface defects. Silylation introduces a flake-like morphology followed by a network-like morphology for fluorophoric modification. Fig. S4 of ESI† gives the elemental mapping of GOPND; also, the elemental percentage endorses the result of CHN analysis. HR-TEM images (Fig. 3e–i) show the same as SEM; the functionalized GO also formed in a sheet-like morphology with multiple stacking of layers in all the steps, and the presence of wrinkles on the sheets indicated their functionalization. The functionalized GOPND finally exists as a clear sheet-like morphology without any crumbling or flooding, which agrees with the SEM images.
![]() | ||
Fig. 3 SEM images of GO (a), GOP (b), GOPN (c), GOPND (d), HR-TEM images GO (e), GOP (f), GOPN (g), GOPND (h and i) and SAED pattern of GOPND (j). |
From all the above spectroscopic and microscopic analyses, the covalent modification was unambiguously characterized and based on the characterization results a plausible structure of GOPND is proposed (Scheme 1).
After meticulously characterizing the as-prepared GOPND material, its application has been disclosed as a heterogeneous carbon-derived sensing probe to detect environmentally influential analytes. The presence of the bis(pyridyl) motif in GOPND is expected to be an analyte binding site, with the luminescent dansyl motif as a signalling unit, and both are synchronized together and anticipated to give a good PL response through the energy transfer pathway. The as-prepared GOPND has good dispersibility in water, which gives an excellent UV-vis spectrum with three absorption bands at 214, 268, and 369 nm (Fig. 4). Its respective precursor GOP showed absorption at 265 and 287 nm, and successive silylated GOPN gave peaks at 229 and 258 nm. When compared to electronic spectra (Fig. S5, ESI†) of all precursors and free organic motifs bis(pyridyl) and dansyl chloride, after functionalization, the three peaks of GOPND were red-shifted to longer wavelength owing to the energy transfer capability of GO; this is further evidence of covalent functionalization. In the solubility studies of GOPND with different solvents, a more stable dispersion was observed in water than in other organic solvents; hence all absorption and emission studies were carried out in an aqueous phosphate-buffered saline (PBS) buffer medium to maintain the pH at 7. In general, dansyl chloride is insoluble in water; however, the covalently functionalized GOPND offers a better dispersibility and also enhances the solubility of dansyl, further resulting in an excellent green, fluorescence when exited at 365 nm. Fig. S6 reveals the emission spectra of PAE, GOP, GOPN, DCL and GOPND at λex = 370 nm. Further to understand the absorption response of GOPND, it was studied with a series of metal ions, including alkali, alkaline earth, p-block, transition, and rare earth metals with different oxidation states, such as Ag(I), Al(III), Bi(III), Ca(II), Co(II), Cr(III), Cu(II), Fe(III), Hg(II), K(I), La(III), Mg(II), Na(I), Ni(II), Pd(II), Rh(II), Ru(III), Sn(II), Zn(II) and Zr(IV). But none of the metal ions showed any distinct response to the GOPND probe, and there was no change in the absorption intensity; however, a blue-shift was noted.
Further, to explore the interaction of metal ions with the probe, an absorption titration was carried out using GOPND (10 ppm) with a random concentrations of metal ions (10, 100, and 200 ppm) in which, except for Ru(III), no metal ion showed any response (Fig. S7, ESI†). Whereas after the addition of 100 ppm of Ru(III), a visual enhancement was found with a blue-shifted absorption band at 281 nm, and it continued with 150 ppm. With these encouraging results, a complete titration using 10–200 ppm of Ru(III) was carried out (Fig. 5), and an apparent enhancement of the blue-shifted bands at 281 nm was observed, and, further, it gets shifted to 276 nm. The change in the absorption is rationalized by the coordination of Ru(III) with bis(pyridyl), which arrests the energy transfer to the dansyl motif in the ground state, which is also revealed by the absence of a visual colour change. The preliminary absorption studies showed a notable change while interacting with Ru(III). However, it does not provide any informative results regarding the sensing of Ru(III) ions. To develop a reliable sensing methodology further, we moved on to fluorescence studies. The PL studies of GOPND were carried out in an aqueous PBS buffer. Here it is essential to remember that GO and its derived materials do not obey Kasha's rule78 in polar solvents; they exhibit a giant red-edge shift. To find the best excitation wavelength for GOPND in the polar PBS medium, the screened wavelengths were 360, 370, and 380 nm (10 ppm), and that at 370 nm showed an excellent PL response in 519 nm with a maximum intensity in minimum concentration (Fig. S8, ESI†).
Under a similar excitation wavelength except for dansyl chloride, other precursors PAE, GOP, and GOPN are non-emissive (Fig. S6, ESI†). The PL intensity of GOPND was slightly decreased compared to the free dansyl chloride under identical conditions owing to the quenching efficiency of GO.
With the above-screened excitation wavelength, all the metal ions tested in absorption studies, such as Ag(I), Al(III), Bi(III), Ca(II), Co(II), Cr(III), Cu(II), Fe(III), Hg(II), K(I), La(III), Mg(II), Na(I), Ni(II), Pd(II), Rh(II), Ru(III), Sn(II), Zn(II) and Zr(IV), were excited with GOPND. Unlike the absorption results, the PL studies showed a distinct response, where all the tested metal ions were highly inert without any influence on the PL spectra of GOPND (Fig. S9, ESI†) except Ru(III).
Treating 10 ppm of Ru(III) with 10 ppm of GOPND showed an immediate fluorescence quenching when excited at 370 nm. Even with higher concentrations (10 ppm, 100 ppm and 200 ppm) (Fig. 6) none of the other metals quenches the fluorescence enhancement of GOPND (Fig. S9, ESI†).
This reveals that no metal ion other than Ru(III) has any remarkable response towards GOPND. The images of GOPND under a UV lamp in the presence of different metal cations are a visual proof of selective fluorescence quenching for Ru(III) (Fig. 7). This reveals the response of Ru(III) cations towards GOPND. None of the other cations shows any quenching; rather they slightly enhance the fluorescence over Ru(III). Ru(III) selectively quenches the PL intensity. Even the increased concentration of metal ions does not vary the intensity as like Ru(III) and seldom shows a response, whereas the decreasing and increasing concentration of Ru(III) gives respective PL spectra as well as in naked eye detection studies under UV light (Fig. 7). Further, to explore the sensing behaviours of GOPND, a titration was carried out. During the sequential addition of Ru(III) with an increasing 10 ppm scale, complete quenching was noted after the addition of 200 ppm. As observed in Fig. 8, an immediate quenching in the PL response of the GOPND in the presence of Ru(III) at λex = 370 nm strongly represents the high selectivity of GOPND towards the detection of Ru(III) in the aqueous medium.
Though the GOPND showed excellent selectivity by decreasing its PL intensity with Ru(III), the selectivity, sensitivity, and the competitive sensing potential of the probe in the presence of other common metal ions were also investigated, and the results are presented in Fig. 9.
Among all the screened metal ions, the quenching response of Ru(III) ions with GOPND was unique and incomparably higher. During the competitive studies between Ru(III) with other metal ions, on the addition of different metal ions, even with a higher concentration of 50 ppm together with 50 ppm of Ru(III), no notable change in the quenching behavior was shown; indeed, the actual PL quenching nature of Ru(III) with GOPND was retained up to 2%.
The same response was retained even after the concentration of the other metal ion was raised to 110 ppm. Meanwhile, some of the other metal ions were only slightly influenced by the quenching efficiency of Ru(III). Metal ions such as Cu(II) and Rh(II) ions quenched the PL intensity around 19–20% along with Ru(III) ions; however, this behaviour was not shown when those ions were individually titrated. Nevertheless, the competitive quenching behaviour of other metal ions does not influence the selectivity of Ru(III) with GOPND. The competitive studies unambiguously demonstrate that GOPND behaves as an efficient and specific sensing probe for Ru(III) ions, even in the presence of other metal ions with excess concentration.
In the development of the materials as sensing probes, a study of the pH of the medium is inevitable. It is one of the decisive parameters to fine-tune the sensing potential of the developed sensor probe. The as-prepared GOPND has several nitrogen centers in the bis(pyridyl) and dansyl motifs; thus, understanding the role of pH in the sensing medium is essential. The sensing behaviours of the GOPND probe with Ru(III) in different pH ranges from 1 to 14 were studied by tuning the buffer in an aqueous medium. The observed PL quenching response of GOPND in the presence of Ru(III) under different pH ranges have been presented in Fig. 10. The analysis of the pH response plot (Fig. 10) disclosed that the change in the pH directly influences the probe's sensing response. When the pH is decreased towards the acidic, the quenching process starts falling. At pH 5, 6 and 7, the probe is not much influenced, and only an 8 to 18% decrease in the quenching efficiency was noted. However, after pH 4, a sharp reduction of around 68 to 83% in the probe's quenching efficiency was observed. This behavior is rationalized through the protonation of the nitrogens present on GOPND, blocking the binding sites of Ru(III). On the other hand, a similar trend was repeated when the pH increased to 8, and a similar decrease in the quenching efficiency was observed up to pH 11. After pH 12, a sudden drop in the quenching behavior of GOPND was observed and only 13% quenching was noted up to the higher pH 14. These quenching studies of the probe under different pH conditions and the changes in its efficiency strongly endorse that the prepared GOPND probe's sensing behaviour has been influenced by pH and only under physiologically neutral pH is more responsive.
![]() | ||
Fig. 10 Fluorescence response of the GOPND (10 ppm) toward Ru(III) (200 ppm) under different pH conditions. |
Unlike homogeneous chemosensors, probes derived from carbon-based materials are highly stable and retain their PL capability for a long time without suffering any chemical or physical changes. The present GOPND probe is a graphene-derived material and heterogeneous in nature. Hence to understand the stability and PL response of the prepared GOPND probe in PBS buffer media, fluorescence emission intensity and peak shapes were monitored with respect to time. With the probe alone fluorescence intensity was periodically checked in 12 h intervals, revealing that the GOPND is stable in PBS buffer even after 48 h without any remarkable change in peak shape or emission intensity (Fig. 11).
![]() | ||
Fig. 11 Fluorescence response stability study of the GOPND probe at different time intervals (12, 24, and 48 h), λex = 370 nm. Inset: Bar-diagram of fluorescence response with respect to time. |
In addition, the detection ability of the GOPND probe was also monitored using the same stock solution prepared 48 h before, and a negligible change in the sensing behavior was observed (Fig. 12). Both the studies strongly endorse the stability of the GOPND probe in the aqueous medium in Ru(III) detection, which is extremely helpful in using this sensor probe for periodical applications.
Next, to understand the necessity and significance of the covalent modifications on the GO basal plane in the present Ru(III) sensor study, control experiments were pursued using the corresponding precursors used to prepare GOPND. A separate PL study of GO, PAE, and dansyl chloride showed that none of them interact with Ru(III) even at high concentration (200 ppm) and showed no response except for GOPND and Ru(III) (10 ppm) (Fig. S10, ESI†). Further, another successive precursor, GOP, in which the bis(pyridyl) is attached to GO through an ester bond, is highly inert towards Ru(III) without emitting any PL response when excited at 370 nm. Meantime, the same GOP probe is highly responsive towards Zr(IV) and explored as a turn-on fluorescence sensor.79 A similar inert response was also observed with GOPN (Fig. S10, ESI†).
All the above control studies clearly confirmed that complete functionalization of GO with bis(pyridyl) and dansyl motifs and the resulting covalently modified GOPND could act as a responsive turn-off sensor only for Ru(III). In another study, a physical mixture of GO (2.5 ppm), PAE (2.5 ppm), APTES (2.5 ppm), and dansyl chloride (2.5 ppm) along with Ru(III) (100 ppm) was tested and the physical mixture did not show any fluorescence quenching.
This reveals that the physical mixture does not exhibit the fluorescence of GOPND and furthermore the quenching behavior does not originate from the non-covalent binding or physisorption (Fig. S11, ESI†). In another study, to understand the fate of GOPND after Ru(III) sensing, the used probe was collected and recovered by centrifugation. The recovered probe was repeatedly washed with water and dialyzed three times in DD to remove the Ru(III) ions and finally washed with dry acetone. The complete removal of ruthenium ions and the absence of other species in the recovered GOPND was confirmed by the absorption and emission analysis of the filtrate. Additionally, it was dried under vacuum for 24 h and subjected to FT-IR analysis. The FT-IR study demonstrates that the GOPND probe is disturbed after the sensing process and the dansyl motif is cleaved from GOPND. The absence of the peaks at 785, 1210, 1473, 1390, and 2491 cm−1 corresponding to the dansyl motif revealed the probe's cleavage, and the FT-IR of the recovered samples agreed with that of GOPN. So, after the sensing process was complete, the recovery process may disrupt the sulfonyl amide bonding of GOPND, albeit the rest of the functionalization (GOPN) is not affected (Fig. S12, ESI†). To examine the application of the developed GOPND probe in real-time applications, further studies were carried with the samples collected from natural sources, an aqueous workup of ruthenium-catalyzed reaction, and laboratory effluent. In synthetic organic chemistry and catalysis research, ruthenium-based catalysts have been widely consumed. Notably, ruthenium-derived homogeneous catalysts80 have gained wide application, and after reaction completion, they are discarded as waste. To detect ruthenium from such effluent, we chose three samples to examine the sensing potential of GOPND: the aqueous workup from an RuCl3 derived asymmetric catalysis reaction, and another sample collected from an academic research laboratory drain. One more water sample was collected from the Vaigai riverbed of India. The collected samples were filtered through a 2μ filter, and only the resulting clear aqueous solution was taken for analysis. For the real sample analysis, a 1:
1 ratio of GOPND and samples was taken under the optimized identical conditions and excited at λex = 370 nm. Both the samples collected from laboratories showed an impressive response and a significant quenching in the PL intensity of GOPND (Fig. 13). Meantime a weak response was found from the river water samples. A comparative study of the real-time samples with standard titration measurement shows the presence of 110, 100, and 20 ppm of Ru(III) from aqueous workup, laboratory drain, and river water samples, respectively.
The observed results from the real-time samples were also cross-verified with the ICP-OES analysis, and the results agreed with the GOPND probe result within ±2% error limit. The response and results from the real-time samples strongly ascertain the GOPND probe's efficiency in the detection of Ru(III). The Stern–Volmer plot explains the quenching constant: it is more significant for Ru(III) since Ksv = 9.9 × 103 M−1 (Fig. S13, ESI†). The LOD value was calculated from the Stern–Volmer plot using the standard formula (3σ/k), where ‘σ’ is the concentration of Ru(III) and ‘k’ is the slope obtained from the Stern–Volmer plot.81 Using the above equation, the LOD of the GOPND probe was calculated as 15 nM. The sensing ability of the GOPND towards Ru(III) through fluorescence quenching is rationalized by proposing a mechanism based on literature reports.19,82,83 In general, GO exhibits excellent emission properties owing to the presence of an extended conjugation system and diverse oxygen functionalities; however, in most of the PL studies, due to the charge transfer process, the fluorescence response was quenched by various mechanistic pathways and positioned as a turn-off sensor. With a similar strategy, the present highly fluorescent GOPND covalently functionalized with bis(pyridine) and dansyl motifs acts as a turn-off sensor when it selectively binds with Ru(III). Here, the GO basal plane provides a better platform for electron–hole recombination, which is induced by the electronic transitions between the non-oxidized carbon atom regions and oxidized carbon atom regions. The prepared GOPND probe was designed based on the energy transfer phenomenon, where the energy acceptor and donor are separated by the Förster energy distance. When the silyloxy propyl unit acts as a spacer between bis(pyridine) functionalized GO and the dansyl motif, it all comes into close proximity. From the literature,84 it is understood that the dansyl motif acts as an energy donor, and the bis(pyridine) unit is positioned as an acceptor in GOPND. GOPND itself emits green fluorescence at 365 nm in an aqueous medium owing to the presence of the dansyl motif.
When excited at 370 nm, the excitation wavelength of dansyl chloride, it gives maximum fluorescence enhancement in an aqueous medium which is due to the giant red edge effect of GO. (It is possible only due to the functionalization of dansyl with GO; hence the dansyl motif alone has low or no fluorescence under an aqueous medium.) Meanwhile, the addition of the Ru(III) readily and selectively binds with the bis(pyridine) owing to the existence of a pseudo-cavity caused by two pyridinic nitrogens and one aliphatic tertiary nitrogen (hard base). When GOPND is excited, after the addition of Ru(III), a synchronized energy transfer from the dansyl motifs to the Ru(III) bound bis(pyridine) would take place through Förster resonance energy transfer. After the energy transfer from the dansyl unit to the Ru(III) bound bis(pyridine), there is a lack of sufficient energy required for the free rotation of the N,N-dimethyl group of the dansyl motif and the restricted conjugation of the lone pair of electrons decreases the fluorescence intensity and results in quenching. The same quenching behavior could also be possible by other quenching mechanistic pathways like ICT and PET; however, since the energy donor dansyl and acceptor bis(pyridyl) are present in the same GO domain as a single molecule, owing to the lack of extended conjugation, other energy transfer mechanisms are not possible. The same behavior continued when the concentration of the Ru(III) was increased and the PL of GOPND was completely quenched after the addition of 200 ppm of Ru(III). On the other hand, in order to understand the role of the covalently functionalized GO in the present Ru(III) detection process, a controlled study was carried with a 1:
1
:
1 physical mixture of the GO, 2-bis(pyridine-2-ylmethyl) amino)ethan-1-ol and dansyl chloride, which did not show any fluorescence quenching response under identical study conditions (Fig. S11, ESI†). This control study strongly ascertained the importance of the covalently functionalized GOPND, where the bis(pyridine) and dansyl motif are brought into proximity on the graphitic domain and facilitate the FRET-based energy transfer to detect Ru(III) in the aqueous medium. Further the efficiency and sensitivity of the present GOPND probe is compared with previously reported Ru(III) detection methodologies (Table S1, ESI†). According to Table S1 (ESI†), so far reported probes show LOD in the region of micro-molar concentrations and very few reports show the nanomolar region; also the sustainability is still questionable and there was a failure to explain the sensing mechanism. Here GOPND has shown reliable results with good sensitivity in a nanomolar detection range and has more advantages than other probes. The present carbonaceous sensor material has an LOD of 15 nM in a complete aqueous medium.
Footnote |
† Electronic supplementary information (ESI) available: Fig. S1 and S2: 1H and 13C NMR of PAE; Fig. S3: ESI-MS; Fig. S4: EDX mapping; Fig. S5 and S6: UV-vis and emission studies; Fig. S7: UV-vis spectral studies of all metal analytes; Fig. S8: PL spectral studies at different wavelengths; Fig. S9: PL studies of all metal analytes; Fig. S10 and S11: Control experiments with PL studies; Fig. S12: FTIR; Fig. S13: Stern–Volmer plot. See DOI: 10.1039/d1ma00175b |
This journal is © The Royal Society of Chemistry 2021 |