Kumari
Sushmita
a,
Petr
Formanek
b,
Dieter
Fischer
b,
Petra
Pötschke
b,
Giridhar
Madras
c and
Suryasarathi
Bose
*d
aCentre for Nanoscience and Engineering, Indian Institute of Science, Bangalore-560012, India
bLeibniz-Institut für Polymerforschung Dresden e. V. (IPF), Dresden-01069, Germany
cInterdisciplinary Centre for Energy Research, Indian Institute of Science, Bangalore-560012, India
dDepartment of Materials Engineering, Indian Institute of Science, Bangalore-560012, India. E-mail: sbose@iisc.ac.in
First published on 8th March 2021
The use of electronic devices and wireless networks is increasing rapidly, and electromagnetic (EM) pollution remediation remains a challenge. We employed a unique approach to fabricate two ultrathin (approx. 53 μm) multilayered assemblies to address this. By sequentially stacking thin films of polyvinylidene difluoride (PVDF) and polycarbonate (PC) nanocomposites and interfacially locking them with a mutually miscible polymer (PMMA, polymethyl methacrylate), materials with enhanced structural properties and electromagnetic interference (EMI) shielding performance can be designed. Utilizing reduced graphene oxide (rGO) and molybdenum disulfide (MoS2) as a template, ferrite was grown on the surface to design two different nanohybrid structures (rGO–Fe3O4 and MoS2–Fe3O4). PVDF was composited with either rGO–Fe3O4 or MoS2–Fe3O4, and multiwall carbon nanotubes (CNTs) were dispersed in the PC component. As PC and PVDF are immiscible, their poor interface would result in inferior structural properties, which can be challenging in designing EMI shielding materials due to cyclic thermal fatigue. Hence, PMMA is sandwiched to interfacially stitch the components (PC and PVDF) and improve interfacial adhesion. This was confirmed using SEM/EDS and Raman mapping/imaging. The mechanical stability of the multilayered assemblies was characterized using a dynamic mechanical analyzer (DMA), and the storage modulus was found to be as high as 2767 MPa at 40 °C (@constant frequency and strain amplitude), for the multilayered film with rGO–Fe3O4 in PVDF, PMMA as a sandwich layer and CNTs in PC. A typical assembly of 9 multilayers (∼480 μm) with rGO–Fe3O4 in PVDF, and CNTs in PC, and interfacially stitched with PMMA gave rise to a high EMI shield effectiveness (SET) of −26.3 dB @ 26.5 GHz. This unique arrangement of a multilayered assembly suppressed EMI primarily by absorption.
Herein, two functional hybrid structures were synthesized using reduced graphene oxide (rGO) and molybdenum disulfide (MoS2) as templates; rGO–Fe3O4 and MoS2–Fe3O4. Several studies have been performed on rGO, MoS2, and Fe3O4 based materials for EMI shielding applications.10,11 For a polymer to act as an EMI shield, conducting and magnetically/dielectrically lossy nanoparticles have to be incorporated. In our work, we have used multiwalled carbon nanotubes (CNTs) as a conducting filler,12 given their ability to form a percolated network at a relatively lower concentration on account of their high aspect ratio, and incorporated rGO–Fe3O4 and MoS2–Fe3O4 as the lossy counterpart. Fe3O4 is a ferrimagnetic semiconducting material.13 In the case of rGO, the extent of reduction of GO decides the properties of rGO in terms of conductivity as well as defects, which play a significant role in EMI shielding. MoS2 is semiconducting and known to be dielectrically lossy.14–17
The dispersion of nanoparticles in a polymer matrix and the interaction between the polymer and nanoparticles play a crucial role in EMI shielding performance. In addition to this, several studies have focused on optimizing nanoparticle design for better EMI shielding properties. This includes synthesizing heterostructured nanoparticles such as core–shell structures and studying their effect on EMI shielding performance by varying the interfaces/interfacial properties.18–20 Another important aspect is the polymer blends/nanocomposite architecture, which includes selective localization of nanoparticles, the multilayer architecture with nanofillers, etc.4,21–23
Multilayered architecture is an exciting research domain known to enhance the shielding effectiveness (SET) at lower thicknesses primarily due to multiple scattering and interfacial polarization, thus giving an advantage over conventional shields. Zhang et al.23 reported a multilayered assembly of regenerated cellulose as the supporting substrate and polyethylene oxide (PEO)/CNT as the EMI shielding layer. PEO enhanced the interfacial adhesion between the CNTs and the cellulose layers due to its favorable compatibility with cellulose chains. Compression molding was used to sandwich the PEO/CNT (1:4) layer between the cellulose layer, and EMI shielding measurements were performed in the X-band. For a film thickness of 150 μm, the layered structure showed a SET value of −35 dB compared to −20 dB demonstrated by the plain structured composite, which was prepared by direct mixing of CNTs into cellulose solutions. Xu et al.22 reported a highly conductive sandwich structure of a nylon/nickel film prepared by the electroless deposition method. For a film thickness of 100 μm, SET was reported to be −77 dB in the X-band. Wang et al.24 fabricated nitrogen-doped graphene multilayer films by thermal annealing of stacked graphene oxide/copper phthalocyanine (GO/CuPc) multilayer films. The maximum SET value of −55.2 dB was obtained for a shield thickness of 0.47 mm in the X-band. Biswas et al.21 stacked individual functional nanocomposites consisting of PC/PVDF blends with CNTs, functionalized CNTs, and CNTs conjugated with flower-like Fe3O4 nanoclusters for effective EMI shielding performance. This compression-molded stack showed a shielding efficiency of −64 dB at 18 GHz frequency for a shield thickness of 0.9 mm. In another work by Biswas et al.,4 a multilayered assembly with PC/PVDF + 3 wt% CNT sandwiched between PVDF + 3 wt% CNT–MnO2 + rGO/Fe was constructed. For a shield thickness of 0.9 mm, the EMI shielding effectiveness was approximately −57 dB in the frequency range of 8–18 GHz.
The literature also suggests that it is not only the type of nanofiller but also the type of polymer and sequential stacking of these layers that become important in designing a robust multilayered assembly for EMI shielding applications. The choice of polymers in our work is based on the existing PVDF/PMMA and PMMA/PC blend systems in the literature. It is reported that PMMA decreases the interfacial tension and enhances the interfacial adhesion between PC and PVDF.25–28 It is miscible with both PC and PVDF and is known to act as a common solvent in the melt state.29–33 Also, few articles report that PVDF/PMMA is miscible in the solution state (forms homogeneous solution under certain conditions) due to the interaction between the H-atom of PVDF and the O-atom in the carbonyl group of PMMA, but they phase separate after solvent evaporation.30,34 Besides, Sharma et al.35 reported that the strong intermolecular interaction in the melt state of the PVDF/PMMA blend system not only arises from hydrogen bonding between carbonyl groups in PMMA and the –CH2 groups of PVDF but also the dipole–dipole interactions between –CH2 of PMMA and CF2 in PVDF. Similarly, there are reports where PMMA/PC results in a homogeneous solution under certain conditions.36,37 Blend miscibility (above 200 °C) between PMMA and PC can be explained using various chemical reactions such as unzipping of PMMA, the attack of PMMA macroradicals on PC chains, trans-esterification of the PMMA ester pendant group with PC, and termoxidative branching leading to graft copolymer inducing re-homogenization at high temperature.29 Few other articles on PMMA/PC blend systems confirm that the specific interactions between the ester group of PMMA and the phenyl ring of PC under certain conditions play a significant role in miscibility.37,38
This work's uniqueness lies in polymer selection and the processing technique used for the construction of the multilayered EMI shielding stack. Herein a doctor blade setup has been used to stack the PVDF, PMMA, and PC layers sequentially. Thus, PMMA was chosen to stitch PC and PVDF layers interfacially. We carried out a templated growth of Fe3O4 on rGO and MoS2 for uniform dispersion. By rationally stitching materials with different characteristics as ‘interfacially locking, PMMA’ between a conducting layer (PC with CNTs) and lossy layer (PVDF with either rGO–Fe3O4 or MoS2–Fe3O4), the incoming EM radiations can be blocked.
Preparation of PVDF-hybrid nanoparticle (rGO–Fe3O4 or MoS2–Fe3O4) solution: 1.8 g PVDF was dissolved in 7 mL DMF, and 200 mg of nanoparticles were dispersed in 3 mL DMF via bath sonication for 30 min. Shear mixing and magnetic stirring were avoided as Fe3O4 is magnetic. PVDF solution was then added dropwise to the nanoparticle dispersion, and the final dispersion was bath sonicated again for 20 min to obtain as homogeneous dispersion as possible.
Preparation of PMMA solution: PMMA solution was prepared by dissolving 3 g PMMA in 10 mL solvent.
Preparation of PC–CNT solution: 2.425 g PC was dissolved in 7 mL solvent. 75 mg CNTs were then added into 3 mL chloroform in a separate vial and bath sonicated. Since the viscosity was too high for casting, 10 mL chloroform was further added to the CNT dispersion, and bath sonication was carried out for 30 min. The PC solution was then added dropwise to the CNT dispersion and shear mixed at 9000 rpm for 45 min to obtain a homogeneous PC–CNT dispersion.
After preparing the three solutions/dispersions described in Section 2.3, the PVDF-hybrid nanoparticle dispersion was cast using a doctor blade setup (100 μm slit) and dried partially for 45 min at room temperature. Subsequently, the PMMA solution was cast using the doctor blade (200 μm slit) above the previous film and dried for 15 min at room temperature. Next, PC–CNT dispersion was cast using a doctor blade (300 μm slit) and dried for 15 min. The multilayered film was immersed in cold water for a few minutes and peeled off. It was then placed between two steel plates and dried in a vacuum oven at 60 °C. It is to be noted that this technique of sequential casting using increasing slit height (100 μm, 200 μm, 300 μm) was performed to obtain a 100 μm thick layer, each of PVDF-hybrid nanoparticles, PMMA and PC–CNT. However, after solvent evaporation, the actual thickness obtained is less than the total expected thickness of 300 μm, as is later seen in the scanning electron micrographs.
The final multilayered stack is shown in Scheme 3. PVDF with hybrid nanoparticles (rGO–Fe3O4 or MoS2–Fe3O4) and PC–CNT composites are sandwiched using PMMA as an interfacial layer, and this multilayer is denoted as PVDF(nanofiller name)/M/PC. The multilayered assembly with rGO–Fe3O4 is represented as PVDF(rGO–Fe3O4)/M/PC, and MoS2–Fe3O4 is represented as PVDF(MoS2–Fe3O4)/M/PC hereon. It is to be noted that the multilayered assembly always has CNTs as a nanofiller in the PC layer, but for simplicity of nomenclature, we haven't explicitly mentioned it.
Control samples of PC–CNT were prepared by casting the dispersion of PC + 3 wt% CNT using a 300 μm slit, and the subsequent procedure was the same as shown in Scheme 3. The control samples of PVDF + rGO–Fe3O4 (10 wt% nanoparticles) and PVDF + MoS2–Fe3O4 (10 wt% nanoparticles) were also prepared by casting the respective dispersions individually using a 300 μm slit, but the film obtained was very brittle due to the high loading of nanoparticles, as shown in Fig. S5.† The control samples of single-layered PC + 3 wt% CNT, PVDF + 10 wt% rGO–Fe3O4, and PVDF + 10 wt% MoS2–Fe3O4 using the doctor blade approach will be henceforth represented as PC(CNT), PVDF(rGO–rGO–Fe3O4), and PVDF(MoS2–Fe3O4) respectively.
Transmission electron microscopy (TEM) images and the selected area diffraction (SAED) pattern of various nanoparticles were obtained using a Libra 120 TEM instrument. The morphology was analyzed by Raman microscopy using a RAMAN Imaging System WITEC alpha300R (using a 532 nm laser with a power of 5 mW and a 20× objective with a measuring point distance of 500 nm) and scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy analysis (EDS) using a Carl Zeiss Ultra 55 or Carl Zeiss Ultra FE-SEM. Raman microscopy and SEM analysis of the cross-section of the multilayered assembly were performed after embedding it in epoxy and sectioning it using a microtome with a steel knife (for Raman microscopy, 20 μm thin sections) and ultramicrotome with a diamond knife (for SEM, block-face cuts). The SEM samples were coated with ∼10 nm of C to prevent charging in the electron beam. However, the SEM and EDS of nanoparticles were carried out with a few nm of gold coating over it. The differential scanning calorimetry (DSC) of polymers was performed in a copper pan using TA analysis (DSC Q2000) under a N2 atmosphere. Fourier transform infrared (FTIR) spectroscopy was performed using an FTIR instrument bought from PerkinElmer. % transmittance was obtained in the wavenumber range of 4000–650 cm−1 using universal attenuated total reflectance mode (ATR).
Magnetic measurements of the nanoparticles were performed using a physical property measurement system (9T) from Quantum Design. Room temperature AC conductivity studies were performed using an Alpha-A Analyser (Novocontrol, Germany) in a broad frequency range from 10−1 to 107 Hz. Compression-molded discs (10 mm diameter and 1 mm thickness) were used as specimens for electrical conductivity measurements. Broadband (8.2–26.5 GHz) microwave shielding studies were performed using a keysight fieldfox microwave analyzer N9918A. S-parameters (S11, S12, S21, and S22) obtained from a vector network analyzer (VNA) were used to determine the total shielding effectiveness and shielding effectiveness due to reflection and absorption. Melt rheological analysis was performed using a Rheometer (model ARES G2) from TA Instruments, USA. The measurements were carried out under a constant strain of 1% in a nitrogen atmosphere. Two sweeps, between 0.1 and 100 rad s−1, forward and backward, were performed with the same filling, whereby the second one was used for interpretation. The following strain sweep was used to confirm that the selected strain was within the linear-viscoelastic range. Dynamic mechanical analysis (DMA) of the samples was performed using a DMA Q800. DMA samples were prepared by cutting a piece of size 2.2 cm × 0.63 cm from the multilayered thin film and were analyzed in tension mode as a function of temperature at a constant frequency of 1 Hz, constant oscillation amplitude of 3 μm, and strain% of 0.02, which lies in the viscoelastic region.
Fig. 2 shows the SEM micrograph of MoS2 (Fig. 2a and b), and TEM micrograph of MoS2–Fe3O4 (Fig. 2c), and rGO–Fe3O4 (Fig. 2d), respectively. Fig. S3a and b† show the SEM micrograph of MoS2–Fe3O4, and Fig. S3c and d† show the SEM micrograph of rGO–Fe3O4. Fig. 2a and b illustrate a flower-like MoS2 structure of 0.3–5 μm dimensions. The MoS2 nanosheets self-assemble to form a thermodynamically and kinetically stable flower-like MoS2 structure during 24 h of a hydrothermal reaction. Fig. 2c, S3a, and b† show the morphology of MoS2–Fe3O4. We observe that the Fe3O4 nanoparticles have nucleated and grown on the MoS2 surface covering the entire petal-like structure. The size variation of the agglomerated chunks corresponds to 0.1–8 μm. The smaller sizes are more prominent in the TEM micrographs (Fig. S4a†). Fig. 2d, S3c, and d† show the rGO–Fe3O4 structure where spherical Fe3O4 nanoparticles decorate the rGO sheets well. Since both probe and bath sonication is used while synthesizing rGO–Fe3O4, the sheet obtained is of varying sizes from 0.7–20 μm, as evident from the low magnification TEM micrographs (Fig. S4b†). Additionally, Fig. S4c and d† show the SAED pattern of MoS2–Fe3O4 and rGO–Fe3O4 nanoparticles.
Fig. 2 (a and b) SEM micrograph of MoS2, (c) TEM micrographs of MoS2–Fe3O4, and (d) TEM micrograph of rGO–Fe3O4. |
Fig. 3a shows the EDS map of MoS2–Fe3O4, and Fig. 3b shows the EDS mapping of rGO–Fe3O4. The map of MoS2–Fe3O4 and rGO–Fe3O4 shows the presence of individual elements. Though the weight ratios of GO/FeCl3·6H2O and MoS2/FeCl3·6H2O were both kept as 0.4 at the time of synthesis, we observe that the Fe atomic wt% is 32.8% in MoS2–Fe3O4 as compared to 6.2% in rGO–Fe3O4. However, it is to be noted that EDS is more of a qualitative technique than a quantitative one.
Fig. 4 shows the room temperature magnetization plot of the synthesized nanoparticles. rGO–Fe3O4 shows a slightly lower saturation magnetization of 18.6 emu g−1 than MoS2–Fe3O4, which shows a saturation magnetization of 22.2 emu g−1. This is in accordance with the EDS result, where Fe atomic weight% was found to be higher in MoS2–Fe3O4 as compared to rGO–Fe3O4.
Fig. 6 EDS map of the cross section of the multilayered film: (a) PVDF(rGO–Fe3O4)/M/PC; (b) PVDF(MoS2–Fe3O4)/M/PC. |
Fig. 7 Light microscopy images (a and c) and Raman map (b and d) of the cross section of the multilayered film: (a and b) PVDF(rGO–Fe3O4)/M/PC; (c and d) PVDF(MoS2–Fe3O4)/M/PC. |
Fig. 5a–c show the SEM micrographs of the multilayered film's cross-section containing rGO–Fe3O4, while Fig. 5d–f show the SEM micrographs of the cross-section of the multilayered assembly containing MoS2–Fe3O4. In-lens, SE2 (type II secondary electron), and back-scattered electron detectors are three different SEM detectors used to obtain the images for the same location. The micrographs in Fig. 5a and d are obtained by the in-lens detector (generally surface sensitive and used for high-resolution micrographs; in this case, gives the best possible contrast of CNTs), Fig. 5b and e show the results obtained by the SE2 detector (generally for imaging the topography; in this case for imaging both topography and material contrast) and Fig. 5c and f show the results obtained by the back-scattered electron detector (for enhanced material contrast or atomic number contrast).
At first sight, the assembly consists of two layers: a uniform lower layer and an upper layer with varying thickness. CNTs are visible as white dots, mostly in the upper layer of PC; however, there seems to be a slight diffusion across the layers, as evident from Fig. 5a and d. PVDF is present in the lower layer – the light grey areas in Fig. 5b, c, e and f. In the nanocomposite with rGO–Fe3O4, PVDF makes most of the lower layer. In the nanocomposite with MoS2–Fe3O4, PVDF forms spheres uniformly distributed in another polymer. The PVDF is unanimously identified by the presence of fluorine, as can be seen in EDS mapping (F map) in Fig. 6 and S6.† The SEM micrographs show that the hybrid nanoparticles (rGO–Fe3O4 or MoS2–Fe3O4) are mostly restricted to the PVDF layer. Additionally, EDS confirms the location of Fe3O4 (Fe map) and MoS2 (S map), which were attributed to the white dot areas in Fig. 5c and f. Fe and S mapping also confirm that the PVDF portion's layer incorporates maximum Fe3O4 and MoS2–Fe3O4 as expected. Carbon and oxygen EDS mappings cannot be used to distinguish epoxy, PMMA, and PC. Also, it should be noted that the SEM micrographs show no sharp distinguishable interface between the three polymers, suggesting the diffusion of polymers across the interface with no slippage of individual layers (no gaps or cracks between the three different polymeric layers).
Raman microscopy reveals the location of epoxy (red), PMMA (green), and PC (pink) in Fig. 7. PMMA is present with PVDF and PC, suggesting the diffusion of PMMA in both directions as an interfacial agent, sticking the layers of two incompatible polymers (PVDF and PC). This might be due to a combination of factors such as the partial miscibility of PVDF/PMMA and PMMA/PC in the solution state, solvent selection, and the drying time allotted for each layer of the stack processing. PC is not present as a pure component; it always contains CNTs (black areas in light microscopy). In these particular measurements, CNTs were not distinguishable from rGO, and the blue color represents either of the components in Fig. 7. However, CNTs and rGO are well distinguishable in the SEM micrographs. The cyan color marks the presence of an Aquatex embedding substance for light microscopy.
From Fig. 5, we can also observe the variation in thickness along the cross-section of the multilayered film. PVDF, along with hybrid nanoparticles, was cast first, and it faced the glass surface. Hence the PVDF side is comparatively flatter than the PC side, which was exposed to air. This might be because of the difference in the solvent's evaporation rates or the not-so-well dispersed CNTs forming agglomerates, which manifested as bumps in the upper layer. The average thickness of the multilayered assembly is observed to be 53 μm. Also, we observe that this technique has the added advantage of achieving continuous layers of polymeric films with no sharp interface, thus avoiding any slippage between individual layers. Thus, PMMA interfacially locks the PC and PVDF layers.
σ′(ω) = σ(0) + σAC(ω) = σDC + Aωs | (1) |
Here, the exponent “s” ranges from 0 to 1 and depends on the temperature and frequency. It indicates the extent of charge transfer that occurs through tunneling/hopping. It denotes the degree of connectedness of long-range charge hopping pathways or the extent of tortuosity for mobile charges.43
Here, it is to be noted that the CNTs were concentrated in the insulating PC layer, and thus this layer is expected to be highly conducting in nature. PMMA and PVDF are insulating polymers, and rGO–Fe3O4 and MoS2–Fe3O4 are semiconducting fillers. Hence the mid-layer and bottom layer should have ideally made the entire multilayered assembly insulating in nature. But this was not the case, as shown in Fig. 8. This implies that some CNTs have diffused through the layers, as observed in the SEM micrographs, where no sharp and distinct interface at the layer boundary was found.
PVDF(MoS2–Fe3O4)/M/PC shows a lower dc electrical conductivity of 3.6 × 10−8 S cm−1 compared to PVDF(rGO–Fe3O4)/M/PC, which shows a dc plateau at 6.8 × 10−7 S cm−1 at 10−1 Hz. This can be attributed to MoS2, which has a bandgap of 1.23 eV. MoS2 might be comparatively more semiconducting (higher bandgap) than rGO, thus reflecting the difference in the dc plateau value. Also, there might be a possibility that the sheet-like larger structure of rGO makes the percolation threshold lower as compared to that of flower-like MoS2. By fitting the power law, “s” is observed to be 0.99 for PVDF(MoS2–Fe3O4)/M/PC and 0.89 for PVDF(rGO–Fe3O4)/M/PC indicating that charge transfer occurs via tunneling/hopping. This nature of the curve is typical to resistor–capacitor (R–C) networks, representing a microstructure that contains both dielectric (the capacitor) and conductive regions (the resistor).44 The fitting suggests that as one moves from MoS2–Fe3O4 to rGO–Fe3O4 as a filler, the capacitor content is found to decrease from 99% to 89%.
However, the single-layered PC(CNT) exhibits frequency-independent dc conductivity in the entire measured range. This indicates that the PC(CNT) film consists of well-connected CNT pathways. The resistor aspect of the network is far more dominant than the capacitance aspect, which is considered negligible. And the dominant mechanism of charge transfer is via tunneling. Additionally, the real permittivity plot of PC(CNT), PVDF(rGO–Fe3O4)/M/PC, and PVDF(MoS2–Fe3O4)/M/PC is shown in Fig. S7.†
To understand the individual layers' rheological properties, PC + 3 wt% CNT, PVDF + 10 wt% rGO–Fe3O4, and PVDF + 10 wt% MoS2–Fe3O4 solution mixed samples were prepared and compression-molded at 260 °C, 220 °C and 220 °C, respectively, to form individual disks of 25 mm diameter and 1 mm thickness. PC + 3 wt% CNT, PVDF + 10 wt% rGO–Fe3O4 and PVDF + 10 wt% MoS2–Fe3O4 solution mixed-compression molded disc samples are represented as (PC + 3 wt% CNT)/S, (PVDF + 10 wt% rGO–Fe3O4)/S, and (PVDF + 10 wt% MoS2–Fe3O4)/S respectively. The melt rheological measurements of PC-based composites were carried out at 260 °C, and PVDF-based composites were tested at 220 °C using a parallel plate setup. The second sweep results in the frequency range of 100 rad s−1 to 0.1 rad s−1 are compiled in Fig. 9.
Fig. 9 Melt rheological measurements: storage modulus (a and d), loss modulus (b and e), and complex viscosity (c and f) vs. angular frequency plots of PC and PVDF based composites. |
Frequency sweep describes the time-dependent response of the sample in a non-destructive deformation range. High frequencies represent fast motion on short timescales, whereas low frequencies simulate slow motion on long timescales or rest. The amplitude is kept constant, while the oscillation frequency is decreased step-wise from one measuring point to the next. With an increase in the angular frequency, G′ and G′′ increase, while complex viscosity decreases, as shown in Fig. 9. As observed in Fig. 9c, (PC + 3 wt% CNT)/S is orders of magnitude more viscous than neat PC, and this behavior is more pronounced at low frequencies. The reduction in |η*| with angular frequency in (PC + 3 wt% CNT)/S is a typical behavior exhibited by shear-thinning materials. It is also to be noted that neat PC shows negligible frequency dependence, and the complex viscosity increases with the CNT content, which is in accordance with the existing literature.45 The increase in complex viscosity with the addition of CNTs is primarily due to the increase in storage modulus G′, as is seen in Fig. 9a. As compared to G′, the increase in the values of G′′ is lower. It is observed that the slope of the storage modulus in the terminal region decreases with the addition of CNTs, which conforms to the literature.46 The higher modulus and solid-like plateau behavior at low frequencies can be attributed to the active interactions between CNTs. It indicates that the percolated CNTs led to developing a solid-like network between PC and CNTs.47 In (PC + 3 wt% CNT)/S, G′ is observed to be higher than G′′, indicating that the system exhibits a gel-like response with percolation being prominent in the nanocomposite.46
Similarly, neat PVDF, (PVDF + 10 wt% rGO–Fe3O4)/S, and (PVDF + 10 wt% MoS2–Fe3O4)/S also show shear thinning behavior. However, the enhancement in the rheological parameters (G′, G′′ and |η*|) by filler addition is small in the case of (PVDF + 10 wt% MoS2–Fe3O4)/S, while it is more prominent in the case of (PVDF + 10 wt% rGO–Fe3O4)/S. This can be attributed to the better interaction due to the large sheet-like structure of rGO compared to the structure of MoS2, which is also confirmed from the SEM images shown in Fig. 5. A sheet-like structure of rGO holds the ability to lower the percolation threshold and enhance the polymer–filler interaction due to the large interfacial area. It is to be noted that the complex viscosity in neat PVDF exhibits a frequency dependent response, unlike neat PC, which is in accordance with the existing literature.48
As explained by rheology, polymers/polymer composites are viscoelastic entities; hence they exhibit an in-phase and out-of-phase response to the applied input strain. To study the viscoelastic response of the multilayered assembly, DMA was performed in tension mode. Thus, the multilayered assembly's mechanical behavior was investigated by applying a sinusoidal tensile deformation to a sample of known geometry and measuring the response. Fig. 10 shows the storage modulus, E′ of PVDF(rGO–Fe3O4)/M/PC, and PVDF(MoS2–Fe3O4)/M/PC as a function of measuring temperature. At a constant frequency and strain amplitude, the storage modulus at 40 °C for PVDF(rGO–Fe3O4)/M/PC and PVDF(MoS2–Fe3O4)/M/PC was found to be 2767 MPa and 2287 MPa, respectively. The storage modulus is larger in PVDF(rGO–Fe3O4)/M/PC than PVDF(MoS2–Fe3O4)/M/PC, which can be attributed to the better connectivity and compatibility of the multilayered assembly with rGO due to its large surface area, as compared to MoS2. This is also in accordance with the rheology analysis, where (PVDF + 10 wt% rGO–Fe3O4)/S proved to have a higher storage modulus than (PVDF + 10 wt% MoS2–Fe3O4)/S. Thin films of PVDF(rGO–Fe3O4) and PVDF(MoS2–Fe3O4) fabricated using the doctor blade method had cracks and wear and hence not suitable for mechanical analysis (shown in Fig. S5†).
On the other hand, the PC(CNT) film did not show any visible wear, but it was structurally inferior for DMA analysis. It is to be noted that PC is a brittle polymer, but due to the flexibility and high aspect ratio of CNTs, the incorporation of CNTs in PC is possible. However, the low thickness of the PC(CNT) film is probably the reason for its structural inferiority. It is worth noting that incorporating nanofillers such as rGO–Fe3O4 and MoS2–Fe3O4 in PC film casting, especially at such low thicknesses, may not be feasible (extreme brittleness). This is the reason why CNTs were incorporated in PC, and the dielectrically lossy nanofiller (rGO–Fe3O4 or MoS2–Fe3O4) was incorporated in PVDF with an interfacial lock using PMMA. Fig. S5† also suggests that a single layer of the PVDF composite film or PC composite film with abundant nanofillers resulted in inferior film quality compared to multilayered films at a similar film thickness. We can conclude that our approach to shifting from single-layered composites to multilayered films is worthful, seeing the mechanical property enhancement in the multilayered assembly compared to the single-layered composite film.
As a control, one can consider comparing the multilayered composite film's storage modulus with the neat commercial polymers’. The storage modulus of the compression-molded samples of commercial PC (same grade) and PVDF (same grade) is reported to be 2440 MPa and ∼500 MPa, respectively, at 40 °C.49,50
(2) |
SET is the shield's ability to attenuate EM radiation, and it is expressed in units of dB. Shielding occurs via three mechanisms, namely shielding via reflection (SER), shielding via absorption (SEA), and shielding via multiple reflections (SEMR).
SET = SEA + SER + SEMR | (3) |
SET = SEA + SER | (4) |
SEA, SER and SEMR are theoretically expressed according to the following equations:
(5) |
A two-port VNA is used to measure the shielding effectiveness experimentally. Since it is difficult to measure the current and voltage at such a high frequency precisely, the instrument measures the scattering parameters (S11, S12, S21, and S22), which in turn is used to calculate SET, SEA and SER using the following equations:
(6) |
(7) |
(8) |
Fig. 11 shows SET as a function of frequency in the X (8.2–12.4 GHz), Ku (12.4–18 GHz), and K (18–26.5 GHz) bands. The SET values of three different samples, namely PC(CNT), PVDF(rGO–Fe3O4)/M/PC, and PVDF(MoS2–Fe3O4)/M/PC, are compiled and presented. The films were sequentially stacked one above the other using an acrylic-based adhesive, and the number of stacked layers is denoted by ‘z’. For example, [PVDF(nanofiller name)/M/PC]1 denotes a multilayered film in which shielding is measured by stacking one multilayered film, [PVDF(nanofiller name)/M/PC]2 denotes a multilayered film where shielding is measured by stacking two multilayered films; [PC(CNT)]9 denotes single-layered PC(CNT) film where shielding is measured by stacking nine such films, and so on. It is observed that [PVDF(rGO–Fe3O4)/M/PC]9 shows a SET of −26.3 dB, [PVDF(MoS2–Fe3O4)/M/PC]9 shows a SET of −10.6 dB and [PC(CNT)]9 shows a SET of −15.7 dB at 26.5 GHz frequency. Thus, rGO–Fe3O4 proved to be a better filler than MoS2–Fe3O4 to maximize the SET value. The losses in PVDF(rGO–Fe3O4)/M/PC can be attributed to the multilayered assembly's adequate conductivity, the dielectric and magnetic losses due to rGO–Fe3O4, and the multiple scattering phenomena. Multiple scattering arises due to the multiple interfaces created by the nanofiller–polymer and nanofiller (type 1)–nanofiller (type 2), as shown in Scheme 4. The shielding in PC(CNT) is mainly due to the high conductivity of the layer owing to the presence of interconnected CNTs, as is obvious from Fig. 8. However, PVDF(MoS2–Fe3O4)/M/PC showed the least SET, probably because of the film's low conductivity, which arose from the semiconducting MoS2 obstructing the pathway for charge transfer. Also, rGO is a sheet-like larger structure, compared to flower-like MoS2. This can be another possible cause of PVDF(rGO–Fe3O4)/M/PC exhibiting a higher conductivity (lower percolation threshold) as compared to PVDF(MoS2–Fe3O4)/M/PC. It is to be noted that conducting fillers (such as CNTs and to some extent rGO) give rise to conduction losses and eddy current losses, which adds to shielding performance. Also, it is observed that the saturation magnetization of MoS2–Fe3O4 is higher. Still, it did not prove to be a superior filler in the desired frequency range, thus confirming that magnetic properties may not have a significant impact on shielding in the chosen frequency range, which is as expected from Snoek's law. Besides, the flower-like morphology of MoS2 creates additional interfaces, which could have added to the shielding performance through interfacial polarization and multiple scattering. However, the poor shielding performance of PVDF(MoS2–Fe3O4)/M/PC only suggests that shielding efficiency is a trade-off between multiple factors. The dielectric losses expected from MoS2, the interfacial losses, and multiple scattering arising from the flower-like morphology of MoS2 as well as other interfaces are not enough to make PVDF(MoS2–Fe3O4)/M/PC suitable for commercial shielding applications (∼−20 dB). This also suggests that the choice of fillers and distribution of fillers significantly affect the shielding performance. It is to be noted that the average thickness of the multilayered assembly (for 1 layer) is found to be 53 μm as obtained from the SEM micrograph (shown in Fig. 5). The shielding effectiveness results are also compiled for PVDF(rGO–Fe3O4) and PVDF(MoS2–Fe3O4), and they were found to be −0.85 dB and −0.01 dB at 26.5 GHz, respectively. This confirms that semiconducting/magnetic fillers can generally not show high SET only by themselves (Fig. S8†). It is to be noted that the thickness of the EMI shielding specimens is similar and hence comparable. As a control experiment, 1 mm disc of PC + 3 wt% CNT + 10 wt% rGO–Fe3O4 was prepared by melt mixing, followed by the compression molding technique, and SET was found to be approximately −20 dB at 26.5 GHz frequency, which is significantly lower than that of the multilayered stack of 9 layers (SET = −26.3 dB @ 480 μm). The melt mixing-compression molding approach was chosen as a control experiment because a single layered doctor-blade casting with a high nanofiller content gave a structurally inferior film, as already mentioned in Section 4.4. Even the melt mixing approach, with a high nanofiller content, results in processing difficulty, suggesting that a multilayered doctor-blade casting approach can be considered a competent alternative to incorporate a high nanofiller concentration at low thicknesses. The addition of PMMA on its own might not result in an enhanced shielding performance, but this approach allows the addition of a high content of nanofillers at a low thickness (indirectly contributing to enhanced shielding) while maintaining the mechanical performance.
Fig. 12 illustrates the percentage of absorption/reflection for [PC(CNT)]9, [PVDF(rGO–Fe3O4)/M/PC]9, and [PVDF(MoS2–Fe3O4)/M/PC]9 at 8.2 and 26.5 GHz frequency. The absorption/reflection plot for one stack is shown in Fig. S9.† The percentage of absorption for [PC(CNT)]9 is found to be 45.5, for [PVDF(rGO–Fe3O4)/M/PC]9 is found to be 82.1, and for [PVDF(MoS2–Fe3O4)/M/PC]9 is found to be 82.1 at 26.5 GHz frequency. For the multilayered assemblies of PVDF(rGO–Fe3O4)/M/PC and PVDF(MoS2–Fe3O4)/M/PC, absorption is the dominant shielding mechanism, irrespective of the frequency in consideration. This can be attributed to the losses from defect dipole polarization of MoS2, defect dipole polarization of rGO, magnetic losses from Fe3O4, multiple interfacial polarizations from MoS2/Fe3O4, and rGO/Fe3O4 hybrids, and the CNT/nanoparticle–polymer interface.15 The loss mechanism is summarized in Scheme 4. In the case of PC(CNT), the reflection percentage fluctuates drastically with thickness as well as frequency, and it is rather difficult to find a correlation based on current data.
Fig. 12 SEA and SER for [PC(CNT)]9, [PVDF(rGO–Fe3O4)/M/PC]9 and [PVDF(MoS2–Fe3O4)/M/PC]9 at 8.2 and 26.5 GHz frequency. |
The SEM micrographs and Raman mapping showed no sharp interface between the layers, proving that PMMA diffused and acted as a stitching layer to lock the PVDF and PC composite layers interfacially. The average thickness of the multilayer film was observed to be ∼53 μm. The mechanical properties of PVDF(rGO–Fe3O4)/M/PC and PVDF(MoS2–Fe3O4)/M/PC were measured using DMA. At a constant frequency and strain amplitude, the storage modulus at 40 °C for PVDF(rGO–Fe3O4)/M/PC and PVDF(MoS2–Fe3O4)/M/PC was found to 2767 MPa and 2287 MPa, respectively. This value is comparable/higher than the storage modulus of compression-molded samples of neat PC and PVDF, which is reported to be 2440 MPa and ∼500 MPa respectively at 40 °C49,50
By stacking nine multilayered films (denoted by a superscript in nomenclature) one above the other, reaching an assembly thickness of ca. 480 μm, the total EMI shielding effectiveness (SET) at 26.5 GHz frequency was found to be −26.3 dB and −10.6 dB for [PVDF(rGO–Fe3O4)/M/PC]9 and [PVDF(MoS2–Fe3O4)/M/PC]9, respectively. This is significantly higher than the SET value of a 1 mm disc of PC + 3 wt% CNT + 10 wt% rGO–Fe3O4, obtained from a melt mixing, followed by a compression molding approach (approx. −20 dB for 1 mm thickness). Also, rGO–Fe3O4 proved to be a better filler than MoS2–Fe3O4 in enhancing mechanical stability and improving SET. Shielding via absorption is the dominating mechanism for multilayered films, irrespective of the number of stacked layers and the frequency under consideration (8.2–26.5 GHz). The loss mechanism in PVDF(rGO–Fe3O4)/M/PC can be attributed to the multilayered assembly's adequate conductivity, the dielectric and magnetic losses due to rGO–Fe3O4, and the multiple scattering phenomena. Though [PC(CNT)]9 showed a SET of −15.7 dB at 26.5 GHz frequency, it was primarily reflection-based shielding, which can be attributed to the high conductivity induced by the presence of the CNT network. However, PVDF(MoS2–Fe3O4)/M/PC showed the lowest SET, probably because of this film's lower conductivity, which arose from the semiconducting nature of MoS2 obstructing the pathway for charge transfer. Despite the dielectric properties of MoS2 and higher saturation magnetization of MoS2–Fe3O4, it showed a lower shielding performance. This suggests that magnetic materials work more effectively in the lower frequency range, as is also proposed by Snoek's limit. Also, large sheet-like rGO in PVDF(rGO–Fe3O4)/M/PC made the percolation threshold lower than that of the flower-like MoS2 in PVDF(MoS2–Fe3O4)/M/PC. Our study also deduces that the multilayered strategy can lead to a higher SET value as observed when incorporated with the suitable nanofiller.
To the best of our knowledge, this is the first time in the literature that polymer layering has been performed sequentially using the doctor blade setup in EMI shielding applications. Moreover, polymer and polymer–solvent pair selection is unique with respect to their type, and this technique has proven to be efficient in enhancing the SET value while maintaining mechanical stability. Besides, this technique may improve the SET value, but the generalization is somewhat tricky as the SET value is a trade-off between several parameters. But the appropriate choice of fillers and tuning the filler quantity and distribution might help enhance the shielding efficiency while maintaining the structural properties.
Footnote |
† Electronic supplementary information (ESI) available. See DOI: 10.1039/d0na01071e |
This journal is © The Royal Society of Chemistry 2021 |