Open Access Article
This Open Access Article is licensed under a
Creative Commons Attribution 3.0 Unported Licence

Correction: Electrochemical investigation and amperometry determination iodate based on ionic liquid/polyoxotungstate/P-doped electrochemically reduced graphene oxide multi-component nanocomposite modified glassy carbon electrode

Minoo Sharifi, Somayeh Dianat* and Amin Hosseinian
Department of Chemistry, Faculty of Sciences, University of Hormozgan, Bandar Abbas 79161-93145, Iran. E-mail: s.dianat@hormozgan.ac.ir; Tel: +98 76 33670121

Received 21st April 2021 , Accepted 21st April 2021

First published on 11th May 2021


Abstract

Correction for ‘Electrochemical investigation and amperometry determination iodate based on ionic liquid/polyoxotungstate/P-doped electrochemically reduced graphene oxide multi-component nanocomposite modified glassy carbon electrode’ by Minoo Sharifi et al., RSC Adv., 2021, 11, 8993–9007, DOI: 10.1039/D1RA00845E.


The authors regret that eqn (3) and (4) were shown incorrectly in the original article.

The corrected equations are shown below.

3H4SiW4VW7VINi(H2O)O396− + IO3 → 3H2SiW2VW9VINi(H2O)O396− + I + 3H2O (3)

3H6SiW6VW5VINi(H2O)O396− + IO3 → 3H4SiW4VW7VINi(H2O)O396− + I + 3H2O (4)

The Royal Society of Chemistry apologises for these errors and any consequent inconvenience to authors and readers.


This journal is © The Royal Society of Chemistry 2021
Click here to see how this site uses Cookies. View our privacy policy here.