Maryanne
Chelang'at Mosonik
a,
Roberto
Volpe
*a,
Chinonso
Ezenwajiaku
b,
Midhat
Talibi
*b and
Ramanarayanan
Balachandran
b
aSchool of Engineering and Materials Science, Queen Mary University of London, Mile End Road, London E1 4NS, UK. E-mail: r.volpe@qmul.ac.uk; Tel: +44 (0)20 78827748
bDepartment of Mechanical Engineering, University College London, London WC1E 7JE, UK. E-mail: m.talibi@ucl.ac.uk; Tel: +44 (0)20 7694302
First published on 6th May 2021
Pyrolysis provides a route for the conversion of lignocellulosic biomass into solid, liquid and gaseous energy vectors or platform chemicals. Polycyclic aromatic hydrocarbons (PAHs) generated in the vapour phase of the biomass pyrolytic reaction may condense to form tars, which are difficult to further upgrade and cause process inefficiency. Control of tar production requires optimization of reactor design and careful control of reactor operating conditions. In this study, a vertical resistively-heated fixed-bed reactor is used to study the effect of pyrolysis peak temperatures and holding period (at peak temperature) on the formation of PAHs during pyrolysis of two lignocellulosic biomass samples, walnut shells (WS) and almond shells (AS). ‘In situ’ planar laser induced fluorescence (PLIF) is used to optically detect 3-to-5 ring PAHs in the vapour phase immediately above the reactor bed. Results show that the PAH PLIF signal appeared at ∼275 °C for the biomass samples and peaked at ∼400 °C for WS and ∼375 °C for AS, which is in agreement with previous ‘off situ’ analysis conducted by the authors. Beyond 400 °C, the PLIF signal was observed to reduce significantly and almost disappear at 550 °C. Initial PAH formation was attributed to condensation reactions occurring due to the drop in temperature along the sample bed. The detection of the PAH PLIF signal itself and its changing intensities, close to the bed, signified the rapid changes the products released from biomass undergo and emphasised the importance of using online techniques for pyrolysis studies. The detailed understanding of the temperature dependent characteristics of PAH formation from this study could help improve reactor design.
However, offline techniques are often affected by different sample collection and preparation conditions such as cooling of the tar or dilution with a solvent, which could introduce errors in their characterisation. This is mainly related to the highly reactive oxygenated compounds present in tars that react during preparation prior to analysis. The more volatile species, such as benzene, volatise while the heavier fraction may polymerise. Furthermore, the presence of reactive compounds cause biomass tars to age faster than the oil derived ones,16 therefore the time at which tars are analysed after their production influences the analysis outcome. Even when the analyser is placed ‘in-line’ during the reaction, it is often installed far from the reaction zone and at different temperature conditions than that of the reaction. Therefore, the products that undergo analysis are not the tars produced during reaction, but rather the tars which have undergone further modifications induced by the method of analysis. This potentially makes virtually all traditional tar analysis biased. In general, the process of tar formation during pyrolysis is an extremely complex and largely unknown process significantly affected by mass and heat transport through a porous solid medium. Tar precursors, formed on the surface of evolving biochars adsorb and desorb from the evolving porous structure of the solid in a similar fashion to what they would do in a chromatographic column.17 This adsorption–desorption mechanism occurs both at particle and at bed (when present) level. For this reason the biomass sample preparation and configuration and the reactor set-up significantly influence the product outcomes.2 For all the aforementioned reasons, an accurate analysis of pyrolysis tars requires careful preparation of sample environment and reaction set-up and, ideally, the possibility to observe the evolution pathways of tar formation ‘in operando’ in the close proximity of the biomass pyrolysing bed. This is possible using laser induced fluorescence (LIF), a non-intrusive optical diagnostic technique that can provide superior spatio-temporal resolution and does not induce any modification of pyrolysis products during the analysis. Some previous studies have used LIF to study biomass pyrolytic emissions, but only a few have focused on PAHs. Brackmann et al.18 analysed the pyrolysis gases of single birchwood particles and observed fluorescence spectra in the region of 300–500 nm, which was attributed to large hydrocarbons, such 3 and 4 ring aromatics. Zobel et al.19 used LIF to investigate the gaseous reaction products formed from the pyrolysis of large (∼25 mm) wood particles. The authors reported an increase in the yields of char and PAHs, which was attributed to an increase in secondary reactions in the heterogeneous vapour–solid phase during pyrolysis. Dieguez-Alonso et al.20 used LIF, optical spectroscopy and (GC-MS) to characterise tar and PAHs from a fixed-bed pyrolyser of pine and beech wood. The results showed that 2 and 3 ring PAHs are released during primary pyrolytic reactions, while longer residence times cause an increase of secondary reactions resulting in the formation of higher fraction of 3 and 4 ring PAHs.
The above review of literature clearly shows the need for capturing the reaction dynamics occurring during tar formation in a biomass bed, especially in instances where there is use of a single biomass particle and the influence of mass transport is disregarded. Hence, our work aims to apply planar laser induced fluorescence (PLIF) to investigate PAH formation in the vapour phase of biomass (WS and AS) pyrolysis just above the reaction zone of a fixed-bed biomass reactor. Planar measurement (PLIF) was preferred over point measurement (LIF) to allow for better spatial and temporal resolution. Experiments were performed to investigate the effect of peak temperature and holding period, while the fluorescence signals emitted from 3-to-5 ring PAHs were captured to provide information on PAHs concentration in the region immediately above the pyrolysing bed and up to 16 mm from it. The results from this study would be particularly useful to unlock potential for use of aromatic compounds from biomass pyrolysis or elimination of these heavier tars. Therefore, regardless of purpose, understanding how, when and where PAHs are formed in the vapour phase of pyrolysing biomass would be useful to ‘cherry-pick’ desired compounds (or vapours rich in them) as they are formed, to be the building blocks for production of bio-based fuels or chemicals.
The sample is held in the top 15 mm section of the SS tube held in place between two SS wire mesh. The wire mesh at the top of the bed was ‘dome-shaped’ to optimize bed packing. Nitrogen (N2) supplied from the bottom of the SS tube is used to sweep pyrolysis products away while a laser beam intersects the vapors leaving the reaction zone.
A schematic of the experimental setup (including the optical diagnostics, described in the following section) is shown in Fig. 1.
The fluorescence from the PAH species (from here on referred to as the PAH PLIF signal) was captured with an intensified charge coupled device (ICCD) camera fitted with an f/1.2 Nikon lens of focal length 50 mm positioned perpendicular to the direction of the laser sheet. A combination of GG420 and BG12 (high and low pass Schott filter) was used with the ICCD to detect PAHs of 3–5 rings between wavelengths 420 nm and 480 nm.21,22 This range of wave lengths was chosen according to the study of Skoog and co-workers23 who found that the most intense fluorescent behaviour was found in compounds containing aromatic functional groups with low energy transition levels. In their work they conclude that even though compounds containing aliphatic and alicyclic carbonyl structures or highly conjugated double-bond structures may also exhibit fluorescence, it is insignificant compared to aromatic systems. Accordingly, for pyrolytic tars, PAHs are expected to exhibit the highest fluorescence intensity compared to other non-aromatic compounds present in the vapors.
It should be noted that, as demonstrated by O'Sullivan and Testa24 the emission spectra of aliphatic ketones does slightly overlap with PAHs, having an emission range between 340 and 540 nm and maxima at 405. However,25 the absorption cross sectional area of aliphatic ketones is in the order of 10−21 cm2 per molecule compared to PAHs' 10−17 cm2 per molecule. Ultimately, while there might be an overlap of fluorescence between PAHs and aliphatic ketones, this is expected to be negligible owing to 1) a chosen range of wavelength that is beyond the maximum emission for ketones and 2) their cross-sectional area being several orders of magnitude smaller than that of PAHs.
These 100 images were accumulated per condition at a camera frame rate of 10 Hz. The pixel resolution of the detection system within the field of view was 20 μm.
It should be noted that the PAH PLIF signal is considered to be representative of the PAH concentration within the probe volume in this study.
Fig. 2 (a) Background corrected PAH PLIF image and (b) PAHsum profile expressed as a function of height. Red colour denotes higher concentration and blue lower one. |
Reflections from the top of the wire mesh dome at the exit of the reactor were excluded from the image analysis by setting a zero-point 0.4 mm above the dome in the MATLAB® code.
The cumulative PAH signal was determined at different heights (in steps of 20 μm) above the reactor bed up to a height (y) of 16 mm and will be referred to as PAHsum. Fig. 2b shows the PAHsum plotted as a function of height for the image in Fig. 2a.
The laser energy was kept at 20 mJ per pulse for all the experiments, which ensured that the energy was above the threshold value for PAH fluorescence saturation of 8 mJ per pulse, determined similar to ref. 21. The shot-to-shot variation in laser energy was observed to be within ±10%. Therefore, the PAHsum values can be considered independent of any fluctuation in laser energy.
It should be noted that the shape of the PAH PLIF signal is strongly influenced by the flow pattern resulting from the combined effect of the shape of the wire mesh dome and the 3D geometry of porosity in the heated biomass sample. As the biomass sample is pyrolysed some material loss is expected, which is likely to change the flow configuration above the reactor bed. Some evidence of this was observed in the captured PAH PLIF images, as will be seen in Fig. 2 later. Hence, the cumulative value of PAH signal (PAHsum) has been employed to provide qualitative understanding of PAH formation characteristics and their relative concentration in the volatile mix, using the aforementioned color coding.
Fig. 3 PAH PLIF images with increasing temperature for the 550 °C HT condition and for maintaining HT for up to 6 minutes for WS. Red colour denotes higher concentration and blue lower one. |
It is evident from Fig. 3 that, in addition to the changes in PAH PLIF signal, the flow pattern downstream of the dome also changes with increasing temperature. However, for a flow in the laminar regime, it is expected that in close proximity of the dome exit, the effects of buoyancy, flow spread, entrainment on the PAH PLIF signal are insignificant especially in the central axis28 where the measurements were taken. Hence, analysis for this study will focus on the region, which is in close proximity to the dome, that is up to heights of 10 mm from the dome exit, where changes in the PAH PLIF signal can be considered to be mostly reflective of the pyrolysis process. Fig. 3 shows that the first PAH PLIF signals were observed around 275 °C. These signals could be attributed to one or a combination of the following: (1) 3–5 rings PAHs detaching directly from the bed, (2) 1–2 ring PAHs that have detached from the biomass matrix and coalesced to 3–5 ring structures throughout the bed or in the vapour phase, (3) 3–5 rings aromatics formed in the vapour phase from unsaturated alkenes. It should be noted that the temperature just above the bed is on average ∼50 °C lower than the 275 °C measured just under the bed (see section 2.1. for more details). The reduction in temperature through the bed could promote PAH formation in the homogeneous vapour phase as volatiles percolate through the packed bed before escaping it. As hypothesised, these species could be aromatics or also alkenes detached from the solid phase at the bottom of the bed where the temperatures are close to 275 °C. TGA conducted on raw biomass samples by the authors in another study showed that the first DTG peak was detected at 250 °C,29 which may relate to this sharp increase in signal observed at similar temperature in this study.
As the temperature increases further (Fig. 3), the PAH PLIF signal intensity increases up to about 425 °C before decreasing until the signal completely disappears when the temperature reaches 550 °C and is held at that value for 6 minutes. This increase seems to coincide with the scission of C–H covalent bonds in aliphatic chains that is expected to occur at around 320–330 °C, as was demonstrated in previous studies of similarly packed biomass beds.30,31 The thermal breakdown of solid particles generates radical fragments that undergo coupling reactions to form aromatic compounds.29 Fixed-bed reactors are known to promote secondary reactions (such as Diels–Alder) in which biomass particles are stacked on top each other (packed beds). Volatiles moving through the bed react with species both within the particle matrix and on the particle surface in a series of homogeneous (vapour–vapour) or heterogeneous (vapour–solid) reactions.32 The outer surface of the particles can be expected to be significantly hot as it comes in direct contact with the N2 sweep gas. Stable free radicals are likely to form on the surface of the solid biomass particles from 300 °C. These radicals are highly reactive and can be expected to react with vapours at those temperatures.29,33
The significant reduction in PAHs observed at temperatures above 550 °C could be attributed to one or a combination of the following: (1) the thermal cracking of 3-to-5 ring PAHs into lighter compounds, (2) catalytic cracking of aromatics on hot solid surfaces and (3) condensation/repolymerization of PAHs into a higher number of rings that fluoresce at wavelengths not detected by the imaging equipment (as mentioned earlier, the optical setup employed in this study only allowed detection of 3-to-5 ring PAHs). It should also be noted that the presence of inorganics in the solid matrix during reaction may affect the reactions themselves. This is difficult to calculate in the current set-up, however it is expected to favour the reduction of formation of PAH34
The images in Fig. 3 also show that the intensity of the PAH PLIF signal is highest at the central line axis slightly above the pyrolysis reaction zone and reduces with increasing distance away from the high intensity region. This spatial variation in the PAH PLIF signal will be discussed in more detail later.
Fig. 4 PAHsum for different temperatures and heights above reactor bed for 550 HT condition for (a) AS and (b) WS. |
These relatively high PAH concentration may also be caused by a set of dehydration reactions occurred at the lower pyrolysis temperatures causing a decrease in the extent of hydrogen bonding and a lowering of the energy required for further decomposition.30 Beyond 500 °C the rate of cleavage of covalent bond decreases possibly due to sufficient mass loss (see ESI†), reducing the emission of volatiles and hence reducing the PAH signal.
The results in Fig. 4 also show a variation in PAH LIF signal with height above the bed. This is detected for temperatures between 275 and 400 °C. For WS, the PAH LIF signal first increases to peak at about 2.5–3 mm above the reactor bed, and then decreases, while in AS, the signal peaks occur just above the bed and then gradually decrease. Similar trends in the spatial variation of the PAH LIF signal can also be qualitatively observed in Fig. 3. The initial increase in PAH concentration in WS can be attributed to an increase in the rate of 3-to-5 rings PAH formation reactions due to coalescing of smaller rings aromatics in the lower temperature regions above the bed. On the other hand, the reduction in signal can be related primarily to either (1) coalescing of 3-to-5 rings aromatics into heavier compounds (that fall beyond the range of detection) or (2) breaking of 3-to-5 rings PAH into lower number rings compounds (also not within the range of detection). However, the latter seems less plausible due to the lower temperatures in the regions further above the pyrolysing bed.
Fig. 4 clearly shows how the first significant increase in signal occurs at 325 °C for both WS and AS and kept on increasing beyond that temperature up to 400 °C for AS and 425 °C for WS, when signal begins to decay. The PAHsum profiles in Fig. 4 show also an interesting bi-modal type distribution with a second peak 10 mm above the bed for temperatures 325, 350 and 400 °C especially for WS (slightly less pronounced for AS). This means that the concentration of 3-to-5 rings PAHs increases in the vapour phase, most probably due only to homogeneous reactions causing the condensing of lower (<3) rings PAHs into larger compounds as temperature decreases along the area above the packed bed.
Fig. 5 shows how the PAH signal decreases with increasing HP, probably owing to the reduction in the rate of formation of PAHs with time at the same temperature. The figure also shows that as HP increases, the PAH signal decreases more significantly for higher HT. For example, the PAH signal reduced to almost zero when both AS and WS samples are held at 450 °C for 10–15 minutes (Fig. 5c), but significant PAH signal intensity is observed when the samples are maintained at 300 °C even after 30 minutes (Fig. 5a). This observation is also supported by the mass loss during reaction. The solid mass loss at 450 °C was considerably higher at ∼70% compared to ∼40–50% loss for the 300 °C condition (see ESI†). This is an expected consequence of slower reaction kinetics at lower temperatures. The results presented in Fig. 5 provide useful indications on choice of heating profiles to generate the desired amounts of 3–5 rings aromatics when they could be used as precursors for further upgrade in the synthesis of green chemicals.
Peak PAH PLIF signal levels are different between AS and WS, as can be seen in Fig. 5. The difference in signal intensity is particularly evident at 350 °C and 450 °C HT, while at 300 °C and 550 °C, this difference is minimal. This can be attributed to the difference in macro-constituents compositions of AS and WS biomass samples. According to Demirbas A.,26 AS has a higher content of hemicellulose and cellulose than WS, while WS has a higher content of lignin than AS as shown in ref. 26. Different macro-constituents of the ligno-cellulosic matrix contain different bonds and will therefore decompose at different temperatures. The different complexities of the ligno-cellulosic structure are responsible for the variations in the PAH PLIF signal. Cellulose and hemicellulose show relatively simple linear structures; cellulose is a long-chain natural occurring glucose polymer and hemicellulose, while hemicellulose is a heterogeneously branched mixture of polysaccharides.35 Lignin, on the other hand is a more complex three dimensional amorphous cross-linked polymers arising from oxidative coupling of three primary precursors, ρ-coumaryl, coniferyl and sinapyl alcohols.36 Owing to these differences in structure, the decomposition of ligno-cellulosic macro constituents occurs at different temperatures and reaction times. Though the macro-constituents may act synergistically during decomposition of biomass,37,38 the thermal degradation of hemicellulose and cellulose generally occurs (or starts to occur) at relatively lower temperatures between 220 °C and 400 °C and progresses relatively fast, while lignin decomposition is more complex and occurs more slowly over a wide temperature range between 160 °C to 900 °C.39 Comparing the hemicellulose, and cellulose content in both samples as shown in Table 1, one can observe that this content is higher in AS than it is WS. Accordingly, at 275 °C and 300 °C, AS initial decomposition rate is higher than WS.
Fig. 6 Maximum PAH concentration (representing maximum PAH LIF signal) for different (a) and (c) holding temperatures and (b) and (d) holding period. |
Between 350 and 450 °C, the PAH LIF intensity is higher in WS than in AS. This again could be attributed to the higher lignin content (higher energy bonds) in WS than AS. In Fig. 6, the PAHs concentrations levels from AS increase with temperature to reach a maximum at 350 °C and then decrease rather sharply above that temperature. In WS, the PAHs levels increase gradually as HT increase, remain almost non varied at higher temperatures and then decrease more gradually. This may also be related to the higher presence of lignin in WS and hence the more energy needed to decompose it.
• Peak PAH signal was observed about 2.5–3 mm above the reactor bed, which was linked to a reduction in temperatures promoting PAH formation. At higher heights, the PAH PLIF signal decreased possibly due to smaller PAHs fusing to form larger structures which was outside the detection limit of the optical setup. This leads to the conclusion that any change in temperature along the sample collection lines in offline techniques, once the products are released, leads to the rapid change in the released product itself. Therefore, the collected product is entirely different from the released product. This should therefore be taken into account when use of offline techniques is employed.
• PAH PLIF signals were initially observed at temperatures between 250–275 °C close to the reactor for both samples. The detection of the signal was attributed to the coalescing of aromatics and unsaturated alkenes, ejected from the solid particles to form PAHs in the vapour phase.
• PAH PLIF signal was observed to increase up to ∼375 °C for AS and ∼400 °C for WS before subsequently decreasing, and completely diminishing by 550 °C for both samples. The increase was attributed to cleavage of covalent C–H bonds from aliphatic structures, while the reduction was linked to material loss causing decrease in emission of volatiles. This also meant that this temperature range (350–400 °C) is crucial for pyrolysis, as shown in Fig. 6, as the scission of bonds is maximum at this point.
• The PAH signal reduced to almost zero when both biomass samples were held at 450 °C and 550 °C for 10–15 minutes, but significant PAH signal was observed when the samples were maintained at 300 °C even after 20 minutes. This observation was supported by the percentage loss in mass of the biomass sample – ∼40% for the 300 °C HT condition and ∼70% for the 450 °C HT condition. Therefore, industrial systems should be modified for their desired purpose, be it production and collection of biofuels gaseous products or char, at the temperatures mentioned above of between 250 °C and 550 °C.
• The differences observed in the results for WS and AS confirms the influence of sample composition on quantity of volatiles produced. Complexity of lignin structure and simplicity of cellulose and hemicellulose structures is the reason for this difference in PAH PLIF signal intensity. Therefore, if a high quantity of volatile production is desired, samples with lower lignin content should be used. Additionally, further spectroscopic analysis could be employed to resolve the various smaller ring PAHs formed during the pyrolysis, which will help to effectively track the growth of PAHs from smaller rings to larger rings.
HP | Holding period |
HT | Holding temperature |
PAH | Polycyclic aromatic hydrocarbons |
PAHsum | Cumulative of PAH peak profile |
PAHmax | Maximum of PAH cumulative profile |
PLIF | Planar laser induced fluorescence |
WS | Walnut shells |
AS | Almond shells |
Footnote |
† Electronic supplementary information (ESI) available. See DOI: 10.1039/d1re00032b |
This journal is © The Royal Society of Chemistry 2021 |