Yangjie
Li‡
,
Kai-Hung
Huang‡
,
Nicolás M.
Morato
and
R. Graham
Cooks
*
Department of Chemistry, Purdue University, West Lafayette, IN 47907, USA. E-mail: cooks@purdue.edu
First published on 23rd June 2021
Systematic screening of accelerated chemical reactions at solid/solution interfaces has been carried out in high-throughput fashion using desorption electrospray ionization mass spectrometry and it provides evidence that glass surfaces accelerate various base-catalyzed chemical reactions. The reaction types include elimination, solvolysis, condensation and oxidation, whether or not the substrates are pre-charged. In a detailed mechanistic study, we provide evidence using nanoESI showing that glass surfaces can act as strong bases and convert protic solvents into their conjugate bases which then act as bases/nucleophiles when participating in chemical reactions. In aprotic solvents such as acetonitrile, glass surfaces act as ‘green’ heterogeneous catalysts that can be recovered and reused after simple rinsing. Besides their use in organic reaction catalysis, glass surfaces are also found to act as degradation reagents for phospholipids with increasing extents of degradation occurring at low concentrations. This finding suggests that the storage of base/nucleophile-labile compounds or lipids in glass containers should be avoided.
In high-throughput experimentation (HTE), large data sets can be generated quickly, facilitating synthetic route screening and pharmaceutical research.7–12 Recently, glass beads have been used to deliver nanomoles of solid reagents in high-throughput reaction screening13 but, to our best knowledge, there has been no report on studying glass-catalyzed chemical reactions systematically using any high-throughput screening (HTS) system. In this study we use a desorption electrospray ionization mass spectrometry (DESI-MS)14,15 based high-throughput system16 with hardware and software features that enable reproducible quantitative data to be generated from minimal amounts (50 nL) of sample solution. The integrated automatic platform allows both synthetic reactions17 and enzymatic reactions18 to be studied at a throughput of 1 s per sample. Therefore, we performed a single-day high-throughput experiment using the HTE DESI-MS system to screen a large set of glass-catalyzed reactions.
HTE DESI-MS screening allows fast comparisons between reactions with and without glass microspheres, but we are aware that the acceleration factor seen in the DESI-MS data will include contributions from droplet acceleration19,20 as well as glass catalysis. Therefore, nanoelectrospray ionization mass spectrometry (nESI-MS) was chosen for the subsequent detailed studies considering its superb sensitivity21–23 and for the fact that when using a short distance between electrode and MS inlet as well as a small capillary orifice,24 nESI-MS can be used as a reliable non-accelerating analytical method.6,25,26
Glass is not an inert medium and cells could adhere to freshly formed glass surfaces while bioglass is known to be beneficial to tissue growth in clinical use.27 Aside from the use of silica-based materials for containers to store solutions, silica nanoparticles are also an emerging tool in biomedical applications such as drug delivery and imaging.28,29 An additional goal of this work was to evaluate the possible role of glass on chemical stability of stored biochemicals, specifically phospholipids. Evaluation of signaling lipids and lipidomics are crucial for understanding biological processes,30 and recently a MS-based workflow has been developed to study the impact of storage parameters on lipid stability.31 However, there has been a lack of experimental data on how container materials such as glass surfaces might chemically impact the storage of biomolecules in solutions although physical adsorption has been reported.32 Such data is indispensable considering current advances in glass manufacturing33 which could lead to a much wider use of glass to store drug products such as the COVID-19 vaccines.34 Previously, forced degradation of small-molecule pharmaceutics and therapeutic peptides have been studied in detailed in a fast fashion in confined volumes such as levitated droplets.25,35 Here, we are especially interested in how glass surfaces could potentially induce chemical degradation of lipids, peptides, and neuromodulators, specifically phospholipids, and glutathione as well as acetylcholine.
Some facts relevant to this study come from the literature of capillary electrophoresis as well as materials science as discussed below. Glass surfaces are covered with dissociable silanol groups and in contact with a solution, the surface will be negatively charged surface and consist of silanolate anions covered by an electric double layer at the solid/solution interface due to the preferential adsorption and attraction of ions onto and close to the surface.36 Aprotic solvents such as acetonitrile (ACN) can only accept but not donate protons. These solvents can be protonated by surface silanol groups to form silanolate but not deprotonated; amphiprotic solvents such as methanol (MeOH) and water (H2O) yield both protonated and deprotonated solvent molecules by auto-ionization. As a result of the low concentrations of cations in acetonitrile, there is much less shielding of the negative charge at the surface in this solvent.37 In addition, the pKa value of silanol groups is the largest in acetonitrile, followed by methanol, and the smallest in water where both protons and silanolate anions can be stabilized by solvation. Therefore, the base strength of silanolate groups is highest in acetonitrile and the magnitude of ionic adsorption on the silica surface will vary due to differences in stabilization of ions in different solvents.38 It is known in materials science that the structure of soda lime glass can vary from the typical composition shown in the Experimental section. This is described by the so-called modified random network where at the nano-scale the sodium ions are non-uniformly distributed within the glass and so on its surface.39 Moreover, mass spectrometric analysis of newly formed surfaces revealed significant amounts of alkali ions compared to the initial glass surface.40
Reaction types | Reaction schemesa | I P/IR (with glass)b | I P/IR (without glass)b | Accel. factorc |
---|---|---|---|---|
a Reactions were performed for 4 h in the specific solvent indicated at 50 μM for each reactant in the scheme with glass microspheres (0.4 eq. silanolate groups, estimated) and without glass added in the reaction mixture in plastic tubes; monitored ions were indicated and representative mass spectra are shown in Fig. S1. b Reaction progress IP/IR represented by all the peak heights of the monitored product (P) versus the monitored residual reactant (R) as indicated in the schemes was analysed by nESI-MS after four hours of reaction; triplicate reactions were performed to estimate the average (two significant figures preserved) and the standard deviation. c Acceleration (Accel.) factors were calculated (two significant figures) using the average reaction progress with glass versus without glass. | ||||
(1) Elimination | 2.9 ± 0.1 | 0.0014 ± 0.0003 | 2.0 × 103 | |
(2) Solvolysis | 4.0 ± 1.1 | 0.0047 ± 0.0005 | 8.4 × 102 | |
(3) Condensation (charged imine) | 2.0 ± 0.1 | 0.0058 ± 0.0016 | 3.4 × 102 | |
(4) Condensation (neutral imine) | 0.11 ± 0.02 | 0.0042 ± 0.0025 | 2.6 × 101 | |
(5) Oxidation of thiol to disulfide | 0.11 ± 0.07 | 0.0033 ± 0.0003 | 3.2 × 101 |
After 4 hours of incubation at room temperature, three replicates of solutions with glass microspheres and three replicates of controlled reaction mixtures were sampled using nESI-MS and from the signals of the monitored ions we calculated the ratios of the product formed versus the residual reactants. Clearly, the reactions progress much faster with glass microspheres (0.4 eq. silanolate groups) than do the controls. The acceleration factor (ratio of rates with and without glass) can be up to three orders of magnitude for certain types of reactions. The high sensitivity of the measurement enables us to study reactions of neutral reactants and still observe acceleration by glass microspheres as shown in entry 4.
Also, in this set of experiments, we found that no matter what solvent (H2O, MeOH, or ACN) was used, the phenomenon of enhanced kinetics by glass always exists. This motivated us to explore in more depth the chemistry induced by glass surfaces, aiming at understanding the mechanism and solvent effects on reaction acceleration by glass surfaces. Furthermore, the fact that some biomolecules such as acetylcholine and glutathione (entry 2 and 5) can be chemically degraded upon contact with glass when stored as a solution, stimulating our interest in the chemical degradation of a specific set of biomolecules–phospholipids – induced by glass surfaces.
Besides these four base-catalyzed synthetic reactions, we also explored the solvolysis of acetylcholine in acetonitrile as shown in Fig. S6 and S7.† We found that the kinetics of this reaction in acetonitrile were little affected using glass microspheres (1.6-fold increase). This indicates that although silanolate groups at the glass surfaces have strong basicity they lack nucleophilicity and thus do not participate in the solvolysis reaction. This result suggests that the previously discussed glass promoted solvolysis in methanol (entry 2 in Table 1) is mainly due to the power of glass surface as a strong base to generate a better nucleophile (methoxide) by deprotonation of methanol; the effect is similar to that of adding sodium hydroxide to methanol but larger. To further test our hypothesis of deprotonation of solvent molecules by glass surfaces, we tested another amphiprotic solvent, water. Observation of the same product indicated the occurrence of nucleophilic attack by hydroxide on the carbonyl group (hydrolysis of acetylcholine). Moreover, the fact that there was acceleration when methanol or water (after contacting glass microspheres, i.e., supernatant) was added, further supports the hypothesis that silanolate can act as a strong base to convert protic solvent molecules into anions which exist in the supernatant and so promote the reaction. This result broadens the scope of glass effects on chemical reactions since the silanolate groups not only affect base-catalyzed chemical reactions themselves as base catalysts but also act as a strong base to turn protic solvent molecules into powerful nucleophiles to affect nucleophilic reactions.
Because solvent molecules participate in E2 elimination reactions, we also investigated this reaction in detail for multiple solvents under different conditions as shown in Fig. S6 and S8.† Clearly, silanolate groups at glass surfaces in acetonitrile tend not to participate in solvolysis due to their poor nucleophilicity; however, acceleration of the E2 elimination reaction in acetonitrile still occurs by a factor of 71, due to their strong basicity. The results of elimination reactions in protic solvent showed similar supernatant effects to these seen in the case of acetylcholine described above. These findings lead to the conclusion that in such solvents both silanolate groups at glass surfaces and solvent anions produced by glass surfaces contribute to acceleration of base-catalyzed reactions. The relatively poor recovery of glass surfaces in protic solvents after recycling is not fully understood.
As shown in Fig. 3, 16:0–18:1 PE undergoes a significant amount of solvolysis at both ester chains in methanol upon incubation with glass microspheres, the same behavior as seen in the acetylcholine case. Because lipids of very low concentration are often used in the lipidomics studies, the concentration dependence on glass promoted degradation was investigated. After 48-h incubation of 1 mM 16:0–18:1 PE with glass microspheres (with 0.02 eq. silanolate groups, estimated), 17% of the PE was degraded into 16:0 LPE and 18:1 LPE and when the concentration of 16:0–18:1 PE was reduced to 0.2 mM (with 0.1 eq. silanolate groups, estimated) 37% of the PE was degraded. The same solvolysis reactions at both chains and similar concentration dependence were also observed in another zwitterionic phospholipid, 16:0–18:1 PC, and the negatively charged 16:0–18:1 PG. All three phospholipids studied were labile in contact with glass surfaces and when in contact with the same glass surface lower concentrations of phospholipids gave higher percentages of degradation. Representative mass spectra of PC and PG degradation are shown in Fig. S9 and S10† and the degradation percentages calculated from the signal intensities of both lysophospholipids vs. the sum of the signal intensities of lysophospholipids as well as the residual amounts of phospholipid are summarized in the bar chart in Fig. 3. These results should draw attention to possible deficiencies in current protocols involving storage of phospholipids in organic solvents in glass containers.
The reaction containers for the DESI experiments (1 mL Clear Glass Shell Vial, 8 × 30 mm, used without further treatment) were purchased from Analytical Sales and Services, Inc. The vials sat unstirred in Para-dox Aluminum Reaction Blocks (Parallel Synthesis/Optimization 96-Well Block Assembly) with a chemically compatible Teflon PFA sheet on the top, sealed by screwing the cover tightly with two silicone rubber mats for compression sealing. First, 15 mg glass microspheres were weighed and added into the reaction vessels, followed by addition of solvent and then addition of each reagent solution. After brief mixing of the solution at 1 mM, 15 μL of the solutions from the vials were transferred into a polypropylene 384-well plate (microplate, 384 well, V-bottom, natural; Greiner Bio-One North America, Inc.) with four replicate solutions from each vial. Thereafter 50 nL of solution in each well of the 384-well plate were pinned onto a DESI slide (microporous PTFE film – ZITEX G115 from Saint-Gobain Performance Plastics Corporation – manually glued on a Abrisa Technologies glass sheet) without delay with four replicate pinned spots per well and observed under a microscope to be dry right after pinning. DESI-MS experiments were performed, again without delay, with methanol as the spray solvent (2.75 μL min−1) and nitrogen as the nebulizing gas (150 psi). DESI-MS data was collected using a Thermo LTQ XL mass spectrometer with a Prosolia DESI 2D stage mounted on. The source parameters were as follows: capillary temperature 300 °C, capillary voltage +38 V, tube lens voltage +65 V, source voltage +4 kV. The automatic gain control was on with a maximum injection time of 100 ms. Mass spectra were recorded in the range from m/z 50–1000.
The Eppendorf safe-lock plastic tubes (2.0 mL, Eppendorf Quality™, colorless, polypropylene) were used as reaction containers in all the nESI-MS experiments and shut tightly with the cap to prevent solvent evaporation in bulk kinetic studies. The unstirred bulk kinetic study was made using 0.45 mL of reaction mixtures which were first thoroughly mixed at 50 μM (with ca. 15 mg glass microspheres if applicable) and then allowed to sit undisturbed at room temperature in the plastic tubes organized in vial racks followed by occasional sampling using 10 μL aliquots for nESI-MS. For glass recycle experiments, after analysis of the first round of reactions, reaction solution was carefully pipetting out and 1.5 mL of pure solvent was added to wash the used glass microspheres each time for three rounds until the ion signals relevant to reactions reached background levels in the pure solvents, and thereafter the second round of chemical reactions was performed.
Thick/standard wall borosilicate glass without filament (B150-86-10) was purchased from Sutter Instruments, cleaned by sonication in a mixed solvent (acetone:methanol:2-propanol = 1:1:2; HPLC grade) and allowed to dry. The cleaned glass capillaries were then pulled into nESI capillaries with ca. 2 μm tip inner diameter using a Flaming/Brown micropipette puller (P-97 by Sutter Instruments). Non-accelerating conditions were achieved by using a short distance between the nESI sprayer tip and MS inlet (ca. 3 mm). During nESI-MS analysis, the electrode (stainless steel acupuncture needle, Beijing Zhongyan Taihe Medical Instrument Co., Ltd.) was in constant contact with the 10 μL aliquots in the capillary and between trials the needle was wiped using Kimwipes from Kimtech Science® with methanol to avoid carry-over between two rounds of sampling. No carry-over signal was detected between trials. The mass spectrometer used for mass analysis was a Thermo LTQ instrument. The source parameters were as follows: capillary temperature 200 °C, capillary voltage +8 V (−22 V for negative mode), tube lens voltage +40 V (−45 V for negative mode), source voltage +1.5 kV (−1.5 kV for negative mode, applied on the electrode by a clip). The automatic gain control was on with a maximum injection time of 100 ms (250 ms for negative mode). Mass spectra were recorded in the mass range from m/z 50–1000. An average of 100 scans was used in each trial. Peak height ratios were used for kinetic calculations. All experiments were performed in triplicate and standard deviations were calculated to determine uncertainties.
We also provided evidence that glass surfaces can act as strong bases and convert protic solvents to their conjugate bases which then act as base/nucleophile to promote chemical reactions. Last but not least, glass surfaces are also found to degrade chemicals, notably phospholipids, and the storage of base/nucleophile-labile biomolecules in glass containers should therefore be avoided. Increasing extents of degradation at low concentration, as shown in the case of phospholipid degradation, should be of broad interest considering the significance of lipid studies in bioanalytical science.
Footnotes |
† Electronic supplementary information (ESI) available. See DOI: 10.1039/d1sc02708e |
‡ These authors contributed equally. |
This journal is © The Royal Society of Chemistry 2021 |