Hang
Hu
a,
Jyothsna Padmakumar
Bindu
b and
Julia
Laskin
*a
aDepartment of Chemistry, Purdue University, West Lafayette, IN 47907, USA. E-mail: jlaskin@purdue.edu
bSchool of Engineering Technology, Purdue University, West Lafayette, IN 47907, USA
First published on 26th November 2021
Mass spectrometry imaging (MSI) is widely used for the label-free molecular mapping of biological samples. The identification of co-localized molecules in MSI data is crucial to the understanding of biochemical pathways. One of key challenges in molecular colocalization is that complex MSI data are too large for manual annotation but too small for training deep neural networks. Herein, we introduce a self-supervised clustering approach based on contrastive learning, which shows an excellent performance in clustering of MSI data. We train a deep convolutional neural network (CNN) using MSI data from a single experiment without manual annotations to effectively learn high-level spatial features from ion images and classify them based on molecular colocalizations. We demonstrate that contrastive learning generates ion image representations that form well-resolved clusters. Subsequent self-labeling is used to fine-tune both the CNN encoder and linear classifier based on confidently classified ion images. This new approach enables autonomous and high-throughput identification of co-localized species in MSI data, which will dramatically expand the application of spatial lipidomics, metabolomics, and proteomics in biological research.
A recurring task in MSI data analysis is to identify co-localized molecules, which is critical to the identification of key biochemical pathways of interest to biomarker discovery,15,16 drug development,17,18 and clinical diagnostics.19–21 Previous computational approaches used image vector-based similarity measurements to determine molecular colocalizations.22–25 However, these methods cannot correlate high-level spatial features making them disproportionately sensitive to the experimental artifacts and noise, which reduces their generalization capacity towards spatial patterns with similar localization but different contrast. Recently, transfer learning and semi-supervised deep learning approaches using convolutional neural network (CNN) have been developed to cluster ion images and quantify the molecular colocalization, respectively.26,27 These reports indicate that the limited size of MSI data presents a challenge to conventional CNN training frameworks, which typically rely on a large number of annotated images. As a result, these approaches provide a relatively minor improvement over the traditional machine learning methods for finding co-localized molecular images.
Recent advances in self-supervised contrastive learning approaches for computer vision including MoCo,28 SimCLR29 and SwAV30 have opened up new opportunities for learning visual representations without manual annotations. In natural image classification, these approaches provide comparable results to those obtained using supervised learning. In contrastive learning, image representations are learned by generating augmented instances of unlabeled images and using contrastive loss to minimize the difference between augmentations generated from the same image and maximize the difference between augmentations generated from different images. Following its success in computer vision, this strategy has been adopted in several applications in other research fields including classification of electrocardiograms31 and clustering of scRNA-seq data.32 It has been demonstrated that the development of modality-specific data augmentation is critical to the performance of models trained using contrastive learning.
Herein, we report on the development and performance of the contrastive learning approach for clustering of MSI data. We demonstrate that this strategy may be used to overcome the existing gap in the classification of MSI data due to the limited data size. We introduce a robust self-supervised clustering approach, which enables efficient colocalization of molecules in individual MSI datasets by retraining a CNN and learning representations of high-level molecular distribution features without annotations. The modality-specific data augmentation and classification fine-tuning methods were developed to build a fully unsupervised framework with optimal molecular colocalization performance.
In order to assess the improvement of the model during the self-supervised training, we systematically evaluated each training step using a manually annotated benchmark MSI dataset of a mouse uterine tissue acquired using nanospray desorption electrospray ionization (nano-DESI).33 The mouse uterine tissue with several distinct cell types is an excellent model system, which presents diverse molecular localizations. From the data acquired in both positive and negative ionization modes, we manually selected 367 ion images (96 × 96 pixels) and clustered them into 13 classes (see ESI,† methods). We then validated our approach using a publicly available mouse brain tissue MSI dataset from METASPACE.34 It was acquired using matrix-assisted laser desorption/ionization (MALDI),5 which contains 1101 high resolution ion images (224 × 224 pixels) without annotations. Detailed dataset information are summarized in Table S1.† Our results demonstrate the robustness of the self-supervised clustering approach for MSI datasets of different sizes, spatial resolutions, tissue types, and acquisition conditions.
Data augmentation plays a critical role in the training step. It ensures that the learned visual representations of ion images are independent of the employed transformations. This generalization power of SimCLR is critical to learning high-level spatial features instead of pixel-level details. In order to evaluate the performance of this step, we systematically investigated the impact of image augmentation operations on image classification in the benchmark dataset as shown in Fig. 2a. In particular, we used stochastic Gaussian blur, Gaussian noise, and intensity distortion to alter the appearance of ion images along with stochastic translation, resized crop, and rotation to alter their geometry. For each type of augmentation, we performed SimCLR using the same training protocol and evaluated the learned representations using a linear evaluation, in which the accuracy describes the quality of the representation (see ESI,† methods). We also examined the performance of a direct transfer learning (annotated as “no SimCLR” in Fig. 2b and S2b†) and SimCLR in the absence of augmentation (annotated as “no augmentation”) for comparison. Fig. 2b shows that all the appearance-changing augmentations improve the performance of the representation learning. Meanwhile, all the geometry-changing augmentations except for rotation do not provide a measurable improvement. Stronger geometric transformations reduce the classification accuracy (Fig. S2†). This observation indicates that in contrast to the semantic classification of natural images, strong alteration of the geometry of ion images is detrimental to representation learning of molecular localizations. We also examined the combined effect of the appearance-changing augmentations on the learned representations. Fig. 2b shows that a combination of three stochastic appearance-changing augmentation operators results in >80% accuracy in the linear evaluation. An example shown in Fig. S3† illustrates the power of the generalization provided by this augmentation strategy. In particular, for ion images that have different contrast and noise level, augmented images generated for one molecule (m/z 789.561 in positive mode) become similar to the original images of other molecules (m/z 746.5108 in positive and 599.3205 in negative modes, respectively). As a result, these molecules are classified into one group in the self-supervised clustering process. Our results indicate that, for MSI data, the generalization power of contrastive learning stems from the appearance-changing image augmentations.
The learned representations for the benchmark dataset are visualized using t-SNE in Fig. 2c and d with the color coding obtained from the manual image classification. The results demonstrate that the pre-trained EfficientNet-B0 model does not separate different classes of ion images (Fig. 2c). In contrast, both the separation and compactness of clusters are dramatically improved using the re-trained encoder (Fig. 2d). These findings indicate that contrastive learning provides meaningful localization representations, which may be used for image clustering without annotations. We also studied the impact of the training time on the learned representations as shown in Fig. S4.† Because the algorithm maximizes the similarity of positive pairs and minimizes the similarity of negative instances, we observe a trade-off between the alignment and uniformity in the learned image representations.36 Alignment indicates that feature vectors of two images from a positive pair should be mapped together while uniformity indicates that all feature vectors should be uniformly distributed. For the benchmark dataset, alignment dominates the training process in the first 50 epochs, in which ion images from the same class tightly aggregate together in the 2D feature space (Fig. S4a†). Further training beyond this point disproportionately increases the uniformity of the data distribution, which is detrimental to the downstream classification. In addition, a fast decrease in the contrastive loss observed in the first 50 epochs is followed by a much slower trend at longer training times (Fig. S4b†) indicating the diminished benefit of a longer training. The linear evaluation results shown in Fig. S4c† indicate that 50 epochs of training provide the best classification of the benchmark data.
Clustering setup | Number of clusters | Accuracy (%) |
---|---|---|
EfficientNet-B0 + SC | 13 | 64.8 ± 0.4 |
SimCLR + SC | 13 | 81.5 ± 3.4 |
SimCLR + SC + self-labeling | 13 | 84.0 ± 3.1 |
EfficientNet-B0 + SC | 20 | 71.9 ± 0.2 |
SimCLR + SC | 20 | 90.0 ± 2.8 |
SimCLR + SC + self-labeling | 20 | 92.7 ± 2.1 |
Because the initial labels are generated using an unsupervised machine learning approach, we anticipate that some false classification may be present. We identified falsely classified images based on their softmax probabilities.39 By excluding these images from training, we improved the robustness of the CNN model, which benefits the classification accuracy. In order to select images with correct classification during the training, we first examined the relationship between the softmax probability and classification accuracy for the CNN model using the benchmark dataset. This model was trained by initial labels obtained from SC and classified ion images into 13 classes. We used a range of softmax probability thresholds to examine the classification accuracy (red trace) and fraction of confidently identified images (blue trace) as shown in Fig. 2f. We observe that the classification accuracy increases with increase in the softmax probability threshold. Meanwhile, the number of confidently classified images decreases. Additional examples of this analysis are shown in Fig. S5† indicating that the observed trend is general.
The results shown in Fig. 2f indicate that there is a trade-off between the number of confidently classified images and classification accuracy. In self-labeling, we chose a probability threshold of 0.9 to start training, for which 58% of confidently classified images were selected with 96% classification accuracy. Self-labeling is performed by re-training both the CNN encoder and classifier using selected images. For each ion image, we use one weak and one strong data augmentation (see ESI, Table S3† and methods), which provides two pseudo labels as the classifier outputs. A cross-entropy loss is calculated for the pseudo labels and the model parameters are updated to minimize the loss as illustrated in Fig. 1. In each epoch, we update the confidently classified images for training using the same softmax probability threshold of 0.9. As illustrated in Fig. 2g, the loss (purple line) decreases with training time. Meanwhile we observe a significant increase in the number of confidently classified images and a slight increase in the accuracy with training time. These results demonstrate that the CNN model corrects itself during the self-labeling process, which gradually includes additional confidently classified ion images into the training and increases the overall classification accuracy.
We used the self-supervised clustering approach to cluster benchmark ion images of the mouse uterine tissue (Fig. S6†) into 13 and 20 groups. The results obtained at different stages of the workflow for five replicates are summarized in Table 1. When clustering is performed using the CNN encoder and SC, contrastive learning (SimCLR) improves the classification accuracy from 64.8% to 81.5% with 13 clusters and from 71.9% to 90.0% with 20 clusters. An improvement of about 20% in accuracy clearly indicates the significance of the CNN retraining for learning image representations in MSI data. In addition, self-labeling provides a 3% improvement in the classification accuracy for both 13 and 20 clusters. Collectively, our self-supervised clustering approach enabled clustering of the benchmark data into 20 groups with 92.7% accuracy as shown in Fig. S7.† Representative ion images for each group shown in Fig. 3 provide a concise summary of the spatial patterns present in the vast MSI data. Meanwhile, the generalization power of the self-supervised clustering approach and its tolerance to noise levels can be assessed by examining images in each class of Fig. S7.†
Fig. 3 20 average ion images obtained from self-supervised clustering results provide a concise summary for comprehensive molecular distribution patterns present in the benchmark MSI data. |
In the example shown in Fig. 4a, we use an ion image of m/z 875.5700 as a reference and correlate it to images of m/z 739.4681 and m/z 868.5243. The pairwise cosine similarity scores obtained using both the CNN feature vectors, generated by the encoder shown in Fig. 2d, and image vectors are listed in Fig. 4b. Although ion images of m/z 875.5700 and 868.5243 indicate that these ions are enhanced in luminal epithelial (LE) cells, the signal of m/z 875.5700 in the LE region is relatively low and the distribution is less distinct than that of m/z 868.5243. In contrast, m/z 739.4681 is enhanced in both the LE and glandular epithelial (GE) cells. Therefore, we expect to obtain a better correlation between ion images of m/z 875.5700 and 868.5243 than between m/z 739.4681 and other two species. The pairwise cosine similarity scores obtained using the CNN feature vectors suggest that the reference ion has a better colocalization with m/z 868.5243 (0.695) than with m/z 739.4681 (0.420), which is consistent with the expectation. However, the similarity scores calculated using image vectors are clearly affected by the low intensities of the reference ion in the GE region and predict the opposite trend. This comparison confirms that the self-supervised clustering approach is substantially more tolerant to chemical noise than vector-based approaches.
We also used the Uniform Manifold Approximation and Projection (UMAP) algorithm to project both the CNN feature vectors and image vectors onto a 2D space, as shown in Fig. 4c and d. In these plots, each ion image is represented by a filled circle and color coded by their manual image classification. The three ion images shown in Fig. 4a are highlighted in the UMAP plot. In the UMAP plot obtained for the CNN feature vectors shown in Fig. 4c, m/z 875.5700 is mapped closer to m/z 868.5243 than to m/z 739.4681, which is in agreement with our expectations. In contrast, m/z 739.4681 is mapped between other two ions in the UMAP plot of image vectors shown in Fig. 4d. We also observe mixing between ion images from class 5 and class 8 in Fig. 4d. This further highlights challenges associated with image clustering using vector-based approaches, which may lead to errors in data structure visualized using UMAP analysis. A similar phenomenon is observed when the Ward hierarchical clustering is applied to image vectors shown in Fig. S9.† This analysis indicates that the Euclidean distance measurement cannot differentiate between the ion image of m/z 739.4681 and two other ion images used in this example. The biases in the similarity measurement using image vectors are observed for a range of ions, as shown in Fig. S8 and Table S5.†
In summary, the CNN feature vectors generated in SimCLR training provide a more accurate pairwise ion image similarity detection than vector-based methods. This is largely due to the strong generalization capability of the re-trained CNN, which identifies high-level spatial features even in noisy MSI data.
Fig. 5a illustrates ion image representations after self-supervised learning using t-SNE visualization. Additional results are provided in Fig. S12.† In the absence of a manual annotation, we use the black color for all the data points in Fig. S12.† With the pre-trained EfficientNet-B0, we could only observe several aggregates at the edge of the 2D ion image representations. However, the uniformly distributed representations in the center of the plot cannot be used for identifying the co-localized ion images (Fig. S12a†). After the contrastive learning step, the re-trained CNN encoder provides a substantially improved separation of the representations as shown in Fig. S12b.†Fig. 5a shows ion image representations after self-labeling, which are color-coded with predicted colocalization labels. Tight clusters indicate co-localized molecular distribution patterns in the MSI data. Pairs of ion images were selected from clusters and placed around the t-SNE plot. Images from one pair have similar spatial features, while different pairs show distinct molecular localizations. These results confirm that the self-supervised clustering approach developed in this study provides accurate molecular localization representations of distinct spatial patterns observed in MSI data. Notably, some of the paired ion images have different noise levels (e.g., m/z 906.4314 vs. m/z 915.4561) or different intensity levels (e.g., m/z 613.3477 vs. m/z 817.1050). These results indicate that data augmentations used in the training step provide a sufficient generalization capability for the re-trained CNN model to identify high-level molecular localization. The ability to perform self-supervised clustering of the unannotated MSI data distinguishes our approach from previously reported methodologies.24–27
We also visualized the ion clustering results in the m/z space. Fig. 5b shows an average mass spectrum over the m/z 600–1000 range, in which peaks are highlighted using the same color coding as that in Fig. 5a. To further evaluate the accuracy of the clustering, we examined the isotopic recall,26 which quantifies the percentage of ion images of isotopic peaks correctly grouped together. We identified isotopic ions based on both the accurate m/z shift and Pearson correlations of ion images (see ESI,† methods). For example, in Fig. 5c, co-localized isotopic peaks observed in the m/z range of 736–765 are annotated using compound indices in gray color, which are ranked by their primary isotopic m/z values. Ion image colocalization results of self-supervised clustering and EfficientNet-B0 followed by SC are also annotated by colocalization class number with blue and red colors, respectively. We note that independent class numbers were assigned to these two classification results. With the expectation that isotopic images should be clustered into the same group, we identified the correctly and falsely classified isotopic ions in clustering results (see ESI,† methods) and marked false isotopic classification with an asterisk. In the mass range shown in Fig. 5c, EfficientNet-B0 and SC falsely classified 3 isotopic peaks, while the self-supervised clustering approach correctly grouped all the isotopic peaks. This result further confirms the accuracy and robustness of the self-supervised clustering. Values of the isotopic recall obtained using different clustering methods are summarized in Fig. 5d. For the clustering involving the CNN encoder and SC, contrastive learning (SimCLR) improves the isotopic recall from 75.4% to 90.2%. With the self-labeling, the final model reaches an isotopic recall of 92.1%, which indicates the superior clustering performance of this approach.
Our findings indicate that the limited size of MSI data is not a bottleneck for self-supervised learning. However, data augmentation is critical to the model training. We use a combination of stochastic appearance-changing transformations, such as Gaussian blur, Gaussian noise and intensity distortion to maximize the generalization power of the CNN model towards the efficient recognition of distinct localization patterns in ion images with varying levels of signal and noise. A similar self-supervised learning paradigm may be applied to other hyperspectral chemical imaging modalities including Raman and infrared microscopy.
The approach presented herein enables molecular colocalization analysis based on the MSI data in an autonomous and high-throughput manner. It provides a concise representation of the vast data containing several hundreds of molecular images, which is critical to understanding biochemical pathways in biological systems. Furthermore, we propose that this approach may be readily expanded into a larger semi-supervised learning framework. The self-supervised paradigm enables representation learning before supervised classification, which is particularly advantageous for automatic ion image labeling necessary for the high-throughput annotation of both MSI data and data obtained using other imaging modalities.
Footnote |
† Electronic supplementary information (ESI) available: Methods and data analysis, MSI images and complete clustering results. See DOI: 10.1039/d1sc04077d |