Issue 10, 2023

Accurate determination of trace silver in geological reference materials by inductively coupled plasma-tandem mass spectrometry (ICP-MS/MS)

Abstract

Silver (Ag) is a trace metal element in geological rocks and accurate determination of its abundance is very challenging given significant oxide and hydroxide interferences from Zr, Nb, Mo, and Y. Here, we developed a valid method based on inductively coupled plasma-tandem mass spectrometry (ICP-MS/MS), in which NH3 was used as the reaction gas, to determine the Ag content in geological samples. The additional quadrupole analyzer located in front of the collision/reaction cell ensured a simple and controllable reaction in the cell. The first quadrupole (Q1) was set to m/z 107 and 109 to allow Ag+ and its interferences to enter the reaction cell. Ag+ partially reacted with NH3, forming Ag+ and Ag(NH3)2+ as the main products; while the major interferences, ZrO+ and NbO+, reacted strongly and were converted to ZrO(NH3)4+, ZrO(NH3)5+, and NbO(NH(NH3)3)+, respectively, and thus no longer affected the measurement of Ag. Consequently, the Ag signals could be detected by both “on-mass” and “mass-shift” methods, where the m/z of Q1–Q2 were 107–107, 109–109 and 107–141, 109–143, respectively. Under the optimized NH3 flow rate (3.5 ml min−1), the interference levels of the matrix solution (0.3 μg ml−1 Zr and Mo, 0.2 μg ml−1 Zn, 0.1 μg ml−1 Y and Nb, and 0.05 μg ml−1 Ga) in four Q1–Q2 mass pairs were negligible and comparable to background signals, and the limits of detection of geological samples were <0.53 ng g−1. The Ag content of 19 geological reference materials was reported using the proposed ICP-MS/MS method, and the results were consistent with isotope dilution-ICP-MS values. Thus, the proposed method has great potential for the accurate, direct, and high-throughput measurement of Ag in geological samples.

Graphical abstract: Accurate determination of trace silver in geological reference materials by inductively coupled plasma-tandem mass spectrometry (ICP-MS/MS)

Supplementary files

Article information

Article type
Paper
Submitted
09 Jun 2023
Accepted
31 Aug 2023
First published
01 Sep 2023

J. Anal. At. Spectrom., 2023,38, 1984-1994

Accurate determination of trace silver in geological reference materials by inductively coupled plasma-tandem mass spectrometry (ICP-MS/MS)

J. Li, K. Zong, D. Yan, Y. Du, Z. Wang, W. Gao, M. Li, J. Lin, W. Zhang, H. Chen, Z. Hu and Y. Liu, J. Anal. At. Spectrom., 2023, 38, 1984 DOI: 10.1039/D3JA00190C

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements