Sonia Freddiab,
Camilla Marzuoli‡§
a,
Stefania Pagliaraa,
Giovanni Dreraa and
Luigi Sangaletti*a
aDepartment of Mathematics and Physics, Surface Science and Spectroscopy Lab@I-Lamp, Università Cattolica del Sacro Cuore, Via della Garzetta 48, 25123 Brescia, Italy
bDepartment of Chemistry, Division of Molecular Imaging and Photonics, KU Leuven, Celestijnenlaan 200F, 3001 Leuven, Belgium
First published on 21st December 2022
Electronic noses (e-noses) have received considerable interest in the past decade as they can match the emerging needs of modern society such as environmental monitoring, health screening, and food quality tracking. For practical applications of e-noses, it is necessary to collect large amounts of data from an array of sensing devices that can detect interactions with molecules reliably and analyze them via pattern recognition. The use of graphene (Gr)-based arrays of chemiresistors in e-noses is still virtually missing, though recent reports on Gr-based chemiresistors have disclosed high sensing performances upon functionalization of the pristine layer, opening up the possibility of being implemented into e-noses. In this work, with the aim of creating a robust and chemically stable interface that combines the chemical properties of metal phthalocyanines (M-Pc, M = Fe, Co, Ni, Zn) with the superior transport properties of Gr, an array of Gr-based chemiresistor sensors functionalized with drop-cast M-Pc thin layers has been developed. The sensing capability of the array was tested towards biomarkers for breathomics application, with a focus on ammonia (NH3). Exposure to NH3 has been carried out drawing the calibration curve and estimating the detection limit for all the sensors. The discrimination capability of the array has then been tested, carrying out exposure to several gases (hydrogen sulfide, acetone, ethanol, 2-propanol, water vapour and benzene) and analysing the data through principal component analysis (PCA). The PCA pattern recognition results show that the developed e-nose is able to discriminate all the tested gases through the synergic contribution of all sensors.
In particular, breathomics, or breath analysis, holds great promise to deliver rapid, non-invasive and low-cost diagnosis of diseases, playing a major role in screening campaigns for those pathologies where an early diagnosis is crucial for the success of the treatment, such as lung cancer. Breath analysis is based on the fact that the quantity and the quality of the volatile organic compounds (VOCs) present in the exhaled breath of healthy patients are different from those found in the exhaled breath of sick patients and that each pathology is related to the presence of specific gas molecules (i.e. the biomarkers) in a fixed quantity.13,14
Currently, commercially available e-noses are mainly based on conducting polymers or metal oxide sensing devices that still present several drawbacks, including a high operation temperature and therefore a high-power consumption, and poor stability.1,15 Therefore, researcher started to look into new materials to develop e-noses, including sensing layers based on nanostructured carbon, such as carbon nanotubes (CNT), graphene (Gr), graphene oxide (GO), and reduced graphene oxide (rGO). CNTs have already been tested in e-noses, disclosing their potentialities for breathomics,11,16–19 and for food/beverage quality tracking.20,21 On the other hand, studies of e-noses based on a set of graphene layers are virtually missing.
Early claims of the sensing capabilities of Gr layers have been reported,22 but over the years they have been replaced by the use of GO, rGO, and related nanocomposites.23–25 Starting from GO, partial removal of oxygen groups, leading to rGO, can be achieved by chemical, thermal, or ultraviolet-assisted process, resulting in gas sensing performance comparable or superior to that of pristine graphene, as the oxygen-related defects behave as chemically active sites. However, GO-based sensing layers present some drawbacks in terms of sample reproducibility due to the poor control on surface functionalization.23,24
In turn, Gr layers allow for a precise determination, and therefore control of the electronic properties. For instance, Gr band structure mapping enabled by angle-resolved photoemission spectroscopy (ARPES) provides unambiguous evidence of the extent and character (i.e. p-type or n-type) of doping, determined either by the interaction with the substrate or by the functionalization, and of the integrity of the electronic structure when exposed to molecules present in the ambient air, such as oxygen and nitrogen.26,27
In this perspective Gr represents a more reliable layer to develop sensing platforms, provided that proper and effective functionalization strategies are introduced to enhance Gr sensing properties. In particular, recent studies have demonstrated the possibility to develop highly sensitive Gr layers upon functionalization,28–32 disclosing important progress in the field of specific molecule sensing in the gas phase that, in turn, can be considered as a promising starting point for the development of graphene-based e-noses. So far only few Gr-based e-noses driven in a FET configuration have been reported,33–35 which requires micro-electronic grade preparation of the device, or e-noses based on capacitors.36 In turn, Gr-based e-noses in a chemiresistive configuration can be assembled following facile preparation routes, but they are still missing.
In the present work, a set of graphene layers on silicon nitride insulating substrates has been functionalized with metal phthalocyanines (M-Pc), with the aim to create a robust and chemically stable interface that combines the chemical (i.e. chemosensing) properties of M-Pc with the superior transport properties of Gr for the development of Gr-based chemiresistors.
M-Pc layers are already used for gas sensing and Cu- and Co-Pc, followed by Zn-, Ni- and Fe-Pc, are the most exploited M-Pc for gas sensing application.37–49 On the other hand, tentative functionalization of graphene-based layers with phthalocyanines has been recently reported, but mostly graphene oxide and the π–π interaction between phthalocyanine and graphene oxide have been considered,50–52 rather than graphene.
Generally speaking, the functionalization of pristine graphene layers with phthalocyanines has not been investigated to a large extent, and sensors based on graphene layers functionalized with phthalocyanines have not yet been introduced as the sensing array into an e-nose.
In detail, we prepared an array of 5 chemiresistive sensors: one sensor based on pristine graphene (Gr_pristine) and 4 graphene sensors functionalized with M-Pc (M = Co, Ni, Zn and Fe), with the aim to test this array of graphene sensing layers as an e-nose. In particular, these M-Pc have been selected due to their reported good sensing performances.49,53–56
The M-Pc layers have been deposited on graphene from a solution by dropcasting, a facile, low cost, and easy functionalization technique. In view of possible applications in the field of breathomics testing of the sensor array has been carried out with ammonia as target gas molecule. Ammonia in the exhaled breath is recognized as the biomarker of both liver and kidney failure and chronic obstructive pulmonary diseases.57,58 Indeed, ammonia concentration around 10 ppb can be found in the exhaled breath of healthy subjects, while in case of liver or kidney malfunctioning this concentration can rise up till 1 ppm.14 Furthermore, ammonia, along with NO2, is usually regarded as a testing gas for novel nanocarbon based sensors.22,59 Following this choice, calibration curves have been drawn, discussing the sensing mechanism of the sensors, in particular of the Gr_CoPc layer, which displayed a distinctive behavior with respect to the other sensors in the set. Then the discrimination capability of the array has been tested, carrying out exposures to several possible interfering gases (acetone, ethanol, water vapour, 2-propanol, benzene, sodium hypochlorite and hydrogen sulfide) and analysing the data through principal component analysis (PCA) in order to assess the role of each sensor in the discrimination process.
Incidentally, also the interfering gas molecules listed above are known to be biomarkers for several pathologies such as diabetes (acetone),60,61 lung cancer (2-propanol, benzene and ethanol),62 asthma (hydrogen sulfide),63,64 and cystic fibrosis (sodium hypochlorite).65
Finally, in the present approach the parallel screening of the Gr-based sensors response upon exposure to these target gas molecules can disclose new sensing layers for targeting specific molecules in case of remarkable response of one sensor over the others.
Batch-to-batch or sample-to-sample variation is primarily affected by the quality of the graphene layers. Therefore, Gr layers with comparable resistivity have been selected for the array after proper functionalization (see Table SI of the ESI†).
The phthalocyanine powders have been dissolved into acetone (NiPc) or ethanol (all the other molecules) with a concentration of 0.1 mM and then, after 10 minutes of sonication, 15 droplets of the solution have been dropcasted on the graphene layer (Fig. 1a) and have been left to dry upon solvent evaporation in air.
The choice of the solvent and concentration was made on the basis of ref. 66. A cross-sectional sketch of the functionalized layers is shown in Fig. 1b.
For a preliminary investigation of batch-to-batch reproducibility, additional samples have been prepared on selected layers, functionalized with NiPc and CoPc (hereafter labelled as Gr_NiPc_A, B and C, Gr_CoPc_A, B and C).
Raman spectra and micro-Raman maps have been collected on a Renishaw-Invia system, equipped with a 633 nm laser source.
The laser light has been focused onto the sample with a 100× objective. An 1800 lines per mm grating and a laser power of 5 mW have been used for the measurements.
AFM images have been acquired with a Park NX 10 AFM system in non-contact mode in air–solid interface with a tip operating at a resonance frequency of about 300 kHz. All the images processing has been performed using the Gwyddion software.67
Baseline resistance and AFM measurements have been carried out also on the three additional samples of Gr_NiPc and Gr_CoPc (Gr_NiPc_A, B and C, Gr_CoPc_A, B and C).
The sensor signals have been acquired using dedicated software, written in the LabVIEW environment. The gas sensing characteristics have been analysed by exploiting the chemoresistive responses upon gas exposure. The basic electronic circuit for chemiresistor gas sensing measurements consisted of a load resistor (RL) in series with the sensor, to which a constant voltage (V = 5 V) is applied. By monitoring the output voltage (VOUT) across the sample, the sensor resistance RS is measured. A scheme of the readout circuit developed for each sensor is shown in Fig. 1b. Therefore, the chemo-resistive responses have been evaluated as: ΔR/R0 = (R − R0)/R0, where R0 is the baseline sensor resistance before exposure, while ΔR = R − R0 is the resistance variation occurring during gas exposure.
Gas exposures have been carried out at room temperature in a sealed custom made chamber, by introducing a mixture of synthetic air with a selected concentration of the analyte under investigation. Two cylinders have been used to feed the chamber through programmable mass-flow controllers (MKS Instruments) operating in a 200–500 sccm range. For ammonia exposures, the first cylinder (certified by SIAD Spa) has been loaded with 47 ppm of ammonia in synthetic air, while the second has been loaded with synthetic air alone (SIAD Spa) and used to change the overall concentration of ammonia in the chamber. Gas from both cylinders was pre-mixed before entering the chamber. During measurements the overall RH was (50 ± 10)%. Exposure time has been set around 1 minute and after each exposure the chamber has been purged by flushing it with synthetic air until the initial resistance value of the sensors has been restored. A scheme of the set-up is reported in Fig. S1.† This procedure has also been exploited for the other tested analytes, i.e. hydrogen sulfide, benzene, acetone, 2-propanol and ethanol.
Regarding ammonia, on the basis of several exposures calibration curves for each sensor have been obtained by plotting the sensor response ΔR/R0 versus the gas concentration.
The Raman spectrum of pristine graphene (Fig. 2 (red curve)) shows the characteristic peaks of graphene: the G and 2D band. The G band, located at 1590 cm−1, is ascribed to the C–C stretching of sp2 hybridized carbon atoms in the graphene lattice.68 The 2D peak around 2648 cm−1 is a second order Raman scattering process and it is related to the breathing mode of carbon atoms in the plane of graphene.68
Regarding the band around 1330 cm−1, it probably comes from two different contributions: as can be seen in the black curve of Fig. 2, silicon nitride substrate has a band in the same position (see also ref. 69), but also the D-band related to defects in graphene could be found around 1330 cm−1.68 Since the monolayer graphene is not highly defective, we could expect that the silicon nitride broad band dominates the feature around 1330 cm−1 in the Gr_pristine spectrum. Regarding the functionalized graphene samples, the G-band is well detectable in the Gr_CoPc sample, while in the other samples it is still detectable though with a very low intensity compared to all the other peaks in the spectra. This is an indication of a lower thickness of the molecule layer for the Gr_CoPc sample with respect to the other functionalized samples. Furthermore, considering the high intensity of the Pc related peaks, we assume that the ZnPc, FePc and NiPc are arranged in a multilayer structure.
The presence of graphene is in any case confirmed by the 2D band, which is always detectable for all samples except for Gr_ZnPc, where a strong luminescence induced by the 633 nm laser beam irradiation is expected for the Zn-based complexes,70 overwhelming the intensity of the Gr 2D band. All the peaks not related to graphene and present in the functionalized samples could be ascribed to the phthalocyanine molecules (see also Fig. S2†).
Fig. S3† shows representative images of the samples in a 3 × 3 μm2 region. Pristine graphene (Fig. S3a†) shows the typical edges of a transferred graphene layer.
Topographic images representative of the Gr_CoPc, Gr_FePc and Gr_NiPc surfaces, shown in Fig. S3b, c and d,† respectively, display a quite uniform distribution of the phthalocyanine molecules on the layer, while regarding Gr_ZnPc the layer presents some agglomerates on the surface, ascribable to not well dissolved phthalocyanines.
Reproducibility of the batch-to-batch preparation in terms of the baseline resistance, before and after functionalization, and of the roughness of the prepared layers, obtained from several AFM images, have been confirmed, investigating the three additional samples of Gr_CoPc and Gr_NiPc (Gr_CoPc_A, B and C, Gr_NiPc_A, B and C) and comparing the result with those obtained from the chemiresistors equipping the e-nose (Gr_CoPc and Gr_NiPc). Results are reported in Tables SII and SIII,† respectively.
Gr_CoPc, Gr_NiPc, Gr_ZnPc, Gr_FePc and a pristine Gr chemiresistors on the e-nose (schematic representation reported in Fig. 3a) have been simultaneously exposed to ammonia.
As an example of the dynamical response of the array, the resistance change measured upon three exposures to high ammonia concentrations (i.e. 64 ppm, 49 ppm and 72 ppm) is shown in Fig. 3b. The exposure time has been set around 1 minute.
First of all, a quick response is observed for all samples (i.e. in a few seconds range) and most of the sensors increase their resistance upon ammonia exposure, disclosing an overall p-type behaviour; the exception is represented by the Gr_CoPc sensor, which exhibits at first, a decrease of the resistance is observed, but after few seconds the resistance starts to increase.
The high concentration used to perform such exposures does not permit a complete recovery in short time, but for concentrations below 15 ppm the recovery is achieved in about 3–5 minutes (see Fig. S4 and Table SIV†).
In order to draw the calibration curve in a concentration range of interest for e-nose applications, a sequence of exposures to ammonia at low concentrations (from 0.5 ppm to 13.5 ppm) has been carried out. The calibration curves of all sensors are shown in Fig. 3c, with the exception of the Gr_FePc chemiresistor, which did not display any response to NH3 for concentrations below 8 ppm (see also Fig. S4†). A Freundlich isotherm (ΔR/R0 = A[NH3]pow) is used to interpolate the data (except for those obtained from the Gr_CoPc layer), and the fitting parameters are reported in Table SV.† The detection limit (dl), reported in Table SVI has been evaluated according to the formula: 3[NH3]/((R − R0)/σ),71 where σ is the fluctuation of the electrical signal. In particular a detection limit of 0.17 ppm, 0.05 ppm, 0.05 ppm, 8 ppm and 0.03 ppm has been found for Gr_pristine, Gr_NiPc, Gr_ZnPc, Gr_FePc, and Gr_CoPc, respectively.
The calibration curves present a sublinear behaviour, which is quite common for gas sensors with carbon-based materials.16,72 From the comparison of calibration curves it is clear that functionalization does not always enhance the response to ammonia; for instance, the response at the highest concentration (i.e. 13.5 ppm) of Gr_NiPc is higher than for the pristine sample, but the response of all the other sensors is lower, and no response at all is observed for the Gr_FePc. On the other hand, the detection limit is always better for the functionalized samples, except for the Gr_FePc sensor.
Rather than being detrimental to gas sensing, this variability among sensing response to different target gas molecules is a quite an important issue for data analysis and classification with machine learning algorithms.
A comparison with literature works has been performed in terms of sensitivity (i.e. sensor response percentage normalized over the concentration: (ΔR/R0 × 100)/[NH3]) and detection limit: the results obtained for the five developed sensors are in line with both graphene-based sensors,28,29,73–80 and reduced graphene oxide functionalized with metal phthalocyanine molecules,81–84 as can be found in Table SVII.†
As for the sensing mechanisms, the resistance increase upon ammonia exposure indicates that the Gr, Gr_FePc, Gr_NiPc, and Gr_ZnPc layers are p-type, consistently with the fact that the electron injection from ammonia reduces the density of holes in these layers.
The behaviour observed for Gr_CoPc is different and can be rationalized also at the light of the sensing of a CoPc chemiresistor layer exposed to ammonia. In this regard, a sample made of CoPc only has been prepared by drop-casting 15 drops of a CoPc solution on a glass substrate. Unlike graphene, glass is assumed to be an inert substrate without any electronic coupling with the Pc film, thus the observed response to gas exposure is related to the behaviour of the Pc film alone. Exposures to different ammonia concentrations have been carried out and the results are shown in Fig. S5.† The CoPc molecule layer decreases its resistance upon ammonia exposure, thus displaying an n-type semiconductor behaviour.
In literature, only the case of p-type graphene functionalized with p-type Pc is discussed by Guo et al.,84 while results on n-type Pc have not yet been reported. Furthermore, the case reported in ref. 84 is different from our case; indeed, there CoPc and rGO were mixed together, while in our case the CoPc molecules form a layer onto the graphene substrate.
A possible sensing mechanism for Gr_CoPc exposed to ammonia is schematized in Fig. 4. Due to the presence of oxygen, pristine graphene in air is considered as a p-type material, thus the Fermi level is below the Dirac point, while n-type doping for CoPc has been experimentally observed, where the HOMO is filled, and electrons are also found in the LUMO (case (1) in Fig. 4).
DFT calculations carried out on a Gr_CuPc system reports that the HOMO is at lower energy with respect to the Fermi level of Gr, while the LUMO is above the graphene Fermi level;85 assuming that this holds also for our CoPc case, the CoPc LUMO can be set above Fermi level of graphene.
Upon dropcasting the CoPc on the graphene layer, a heterojunction is formed, and the electrons in the CoPc LUMO drift towards graphene in order to align the respective states (case (2) in Fig. 4).
Once the equilibrium is reached, the graphene is now “less” p-type doped than in case 1 (decoupled system) and consequently the CoPc molecule layer is less n-type doped. Let us now analyse the case when ammonia is adsorbed at the sample surface considering both low and high ammonia concentrations.
Considering that the Gr layer is not completely covered by CoPc, as can be deduced by Raman map measurements collected on the sample and shown in the ESI (Fig. S6†), in a low concentration regime, ammonia results to interact preferably with the n-type phthalocyanine, donating electrons to them, thus leading to the experimentally observed resistance decrease. When ammonia concentration increases, more molecules reach the sample surface, saturating the phthalocyanines adsorption sites and therefore interacting mostly with graphene. Ultimately, this leads to the experimentally observed p-type behaviour, with an increase of the resistance value.
To support this claim, ΔR/R0 upon different ammonia concentration exposures has been evaluated as a two steps process (see ESI† file for further information): (ΔR/R0)neg and (ΔR/R0)pos as shown in Fig. 5a, and the results are shown in Fig. 5b and c. (ΔR/R0)neg is related to a n-type behaviour, i.e. CoPc layer, while (ΔR/R0)pos is the trend expected for a p-type layer, i.e. graphene.
Fig. 5b clearly shows that the (ΔR/R0)neg value decreases till a threshold concentration value (around 10 ppm), and then remains constant.
This behaviour is compatible with a saturation of the available sites in the n-type doped region of the sample, i.e. the CoPc layer. In contrast, the (ΔR/R0)pos value is zero in the 0–1 ppm range and beyond this range increases with concentration, suggesting that at first the p-type contribution is negligible, then in the 1–10 ppm range this behaviour is comparable with the n-type one, since the absolute value of the response is the same; finally, starting from 10 ppm concentration, the p-type response is dominant.
The sensing mechanism suggested for the Gr_CoPc layer is likely to occur also for the other samples, although the switch from negative to positive ΔR/R0 is not observed, as NiPc, FePc, and ZnPc are recognized as p-type compounds,86–88 thereby displaying a behavior similar to that presented by p-type pristine graphene layers in air (Fig. 3c).
Datasets similar to those shown for ammonia in Fig. 3b have been collected for exposures to acetone, ethanol, benzene, 2-propanol, sodium hypochlorite, hydrogen sulfide and water.
Results are summarized in the histograms of Fig. 6, which shows the responses of the sensors array to the 8 selected target molecules expressed as the sensor response ΔR/R0 evaluated for the highest concentration tested.
All the sensors changed their resistance during exposure to all gases which have been tested, except for pristine graphene exposed to hydrogen sulfide, ethanol and acetone; indeed, in these cases a resistance change has not been observed.
In general, the whole sensor array shows a relevant response, especially to sodium hypochlorite, water and ammonia.
It is interesting to notice that, although Gr_pristine shows one of the best responses to ammonia, its response to the other gases is not the highest, indicating that the functionalization leads to an increase in the selectivity of the sensor array, required also by the statistical methods for the data analysis.
Furthermore, the possibility to test all the sensors in the same conditions, helps to identify the sensors with the best performances: in this array Gr_FePc is promising for 2-propanol and sodium hypochlorite detection, while Gr_ZnPc shows a huge response to hydrogen sulphide and benzene, as compared to the other sensors.
In order to enrich the data set, exposures to different concentrations of the same gas have been considered (see Table SVIII† for the concentration range) and PCA has been carried out on the sensors' responses; the results are shown in Fig. 7. Considering the space generated by PC1 and PC2 (Fig. 7a), not only the set of points ammonia is well separated from the other gases, but also all gases are clearly discriminated in the space, with an overlap of the acetone, 2-propanol and ethanol contributions only.
Taking into account also the third component (Fig. 7b, PC3 vs. PC1), this overlapping can be avoided and also these three compounds are clearly separated in the PCA space. Furthermore, as it has been previously observed on arrays based on CNTs,11,89 a concentration trend is established: going towards the centre of the reference system, the gas concentration decreases. It is worth to mention that although the developed sensors do not show a particular high response to ammonia, when their response is combined in the PCA analysis, the whole array is able to completely discriminate ammonia from the other gas contribution.
Of note, the present electronic nose is able to discriminate also the VOCs that usually are difficult to detect and discriminate with carbon-based sensors, such as acetone, ethanol and 2-propanol. Indeed, for instance considering carbon-nanotubes, it has been proved that these compounds do not provide an effective charge transfer to the bare carbon-based surfaces and a proper functionalization is required.90
Finally, loading plots for PC1, PC2, and PC3 help clarify the role of each individual sensor into the discrimination of target gas molecules. As shown in Fig. 7c, all the sensors equally contribute to PC1 loadings, except for Gr_pristine, which contributes to a minor extent. Therefore, 4 out of 5 sensors are clearly involved in the discrimination of sodium hypochlorite from all the other gas contributions along the PC1 axis of the PC1–PC2 space. PC2 loadings are dominated by the pristine contribution, but Gr_NiPc plays an important role too in the discrimination along PC2 (Fig. 7d). In particular, along PC2 we can clearly discriminate ammonia from all the other gases. Of note that the Gr_pristine sensor is the one showing the best response to ammonia, closely followed by the Gr_NiPc sample (see for instance Fig. 6-top panel). Regarding the discrimination between ethanol, acetone and 2-propanol, achieved only in the PC3–PC1 space, it is clear from the loadings on the component 3 that the central role is played by the Gr_NiPc, closely followed by Gr_CoPc and Gr_ZnPc (Fig. 7e). It is clear, as it is expected, that to obtain a good discrimination it is not mandatory to achieve high response from all the sensors to all gases, but response variability among sensing layers plays a crucial role.
PCA assesses the capability of the 5-sensors array to clearly discriminate all the tested gases in a 3D-space, making the array particularly promising for breathomics, environmental monitoring or food quality tracking application. All the sensors equally contribute to the discrimination capability, since PC3 is defined by Gr_NiPc, followed by Gr_CoPc contributions, PC2 is dominated by GR_pristine and, to less extent, to Gr_NiPc, while Gr_FePc and Gr_ZnPc mainly contribute to the PC1 discrimination.
After AFM and Raman characterization, a sensor array was created with the four functionalized layers and a pristine Gr one in order to build the e-nose. The overall sensing behaviour of the prepared sensors has been investigated at first with exposures to ammonia. We drew the calibration curves and discussed the sensing mechanism in particular for the Gr_CoPc layer. Then, several exposures to ammonia, hydrogen sulfide, benzene, acetone, ethanol, 2-propanol, and water vapour have been carried out and the data have been used to feed the principal component analysis (PCA) and assess the discrimination capability of the device.
Of note, the tested concentrations of almost all gases are relevant for breathomics, where the biomarkers in the exhaled breath can be found in a concentration in a low-/sub-ppm range.11,13,14,57,60,91,92
All tested gases are clearly discriminated in a 3-dimensional PCA space. In particular, it is worth noting the capability of the array to detect VOCs that are usually poorly discriminated with chemiresistors, unless novel approaches for detection schemes and data handling are devised.93
Furthermore, we showed that an e-nose can be used for a parallel benchmarking of possible chemiresistors. Indeed, the possibility to test all the prepared samples on our e-nose simultaneously allowed us to point out the higher sensitivity of the Gr_ZnPC layer to benzene and hydrogen sulfide, and of Gr_FePC to 2-propanol and sodium hypochlorite with respect to the other chemiresistors equipping the e-nose.
So far, e-noses based on Gr chemiresitors have not yet been reported and therefore a benchmarking of our e-nose with similar devices is currently unfeasible. In this perspective, the present work represents a proof of concept, bridging the gap between graphene-based chemiresistors and e-noses. The low-cost and simple functionalization technique, as well as the easiness of use and simplicity of the electronic nose itself, make the presented array suitable and promising for environmental monitoring, food quality tracking and, especially, breathomics applications.
Footnotes |
† Electronic supplementary information (ESI) available. See DOI: https://doi.org/10.1039/d2ra07607a |
‡ Current address: Center for Nano Science and Technology@PoliMi, Istituto Italiano di Tecnologia, Via Giovanni Pascoli 70/3, 20133 Milano, Italy. |
§ Department of Physics, Politecnico di Milano, P.zza L. Da Vinci 32, 20133 Milano, Italy. |
This journal is © The Royal Society of Chemistry 2023 |