Siti Hajjar Yahyaa,
Firas A. Al-Lolageb,
Mohd Muzamir Mahatc,
Muhammad Zahir Ramlid,
Mohd Syamsule,
Shaili Falinaf,
Dania Adila Ahmad Ruzaidii,
Wan Hazman Daniala and
Saiful Arifin Shafiee*adgh
aDepartment of Chemistry, Kulliyyah of Science, International Islamic University Malaysia, Jalan Sultan Ahmad Shah, Bandar Indera Mahkota, 25200 Kuantan, Pahang, Malaysia. E-mail: sabs@iium.edu.my
bDepartment of Chemistry, College of Science, University of Mosul, Mosul 41002, Iraq
cTextile Research Group, Faculty of Applied Sciences, Universiti Teknologi MARA, 40450 Shah Alam, Selangor, Malaysia
dInstitute of Oceanography and Maritime Studies (INOCEM), Kulliyyah of Science, International Islamic University Malaysia, Kampung Cherok Paloh, 26060 Kuantan, Pahang, Malaysia
eInstitute of Nano Optoelectronics Research and Technology (INOR), Universiti Sains Malaysia, Sains@USM, Bayan Lepas, 11900 Pulau Pinang, Malaysia
fCollaborative Microelectronic Design Excellence Centre (CEDEC), Universiti Sains Malaysia, Sains@USM, Bayan Lepas, 11900 Pulau Pinang, Malaysia
gIIUM Health, Safety, and Environment, Kulliyyah of Medicine, International Islamic University Malaysia, Jalan Sultan Ahmad Shah, Bandar Indera Mahkota, 25200 Kuantan, Pahang, Malaysia
hSustainable Chemistry Research Group, Kulliyyah of Science, International Islamic University Malaysia, Jalan Sultan Ahmad Shah, Bandar Indera Mahkota, 25200 Kuantan, Pahang, Malaysia
iSchool of Physics and Material Studies, Faculty of Applied Sciences, Universiti Teknologi MARA, 40450 Shah Alam, Selangor, Malaysia
First published on 8th November 2023
The increasing levels of carbon dioxide (CO2) in the atmosphere may dissolve into the ocean and affect the marine ecosystem. It is crucial to determine the level of dissolved CO2 in the ocean to enable suitable mitigation actions to be carried out. The conventional electrode materials are expensive and susceptible to chloride ion attack. Therefore, there is a need to find suitable alternative materials. This novel study investigates the electrochemical behaviour of dissolved CO2 on roughened molybdenum (Mo) microdisk electrodes, which were mechanically polished using silicon carbide paper. Pits and dents can be seen on the electrode surface as observed using scanning electron microscopy. X-ray diffraction spectra confirm the absence of abrasive materials and the presence of defects on the electrode surface. The electrochemical surface for the roughened electrodes is higher than that for the smoothened electrodes. Our findings show that the roughened electrodes exhibit a significantly higher electrocatalytic activity than the smoothened electrodes for the reduction of dissolved CO2. Our results reveal a linear relationship between the current and square root of scan rate. Furthermore, we demonstrate that saturating the electrolyte solution with CO2 using a bubbling time of just 20 minutes at a flow rate of 5 L min−1 for a 50 mL solution is sufficient. This study provides new insights into the electrochemical behaviour of dissolved CO2 on roughened Mo microdisk electrodes and highlights their potential as a promising material for CO2 reduction and other electrochemical applications. Ultimately, our work contributes to the ongoing efforts to mitigate the effects of climate change and move towards a sustainable future.
As compared to chromatographic and spectrometric techniques such as Fourier transform infrared, electrochemical sensors are simple in their setup.9 Unfortunately, the current noble metal sensors for electrochemical detection such as gold are expensive and susceptible to damages due to the presence of chloride ions in the electrolyte. Meanwhile, the drawbacks of employing metal oxide materials as the electrode material are mostly their elevated operating temperature from 200 to 600 °C and cross-sensitivity towards carbon monoxide, oxygen, hydrogen, and even humidity.10 Other electrochemical techniques such as Severinghaus-type electrodes have pH drift problems which make the obtained results to be unreliable.10 Meanwhile, glass electrodes are difficult to miniaturise, brittle, and expensive which may pose safety risks due to the sharp glasses and may use a lot of spaces.11 Therefore, there is a need to find an alternative material to measure the concentration of dissolved CO2.
The electrochemical reduction of dissolved CO2 may proceed in different ways. Dissolved CO2 is electrochemically reduced to yield different products which involves different number of electrons transferred.12 Table 1 summarises the possible electrochemical reactions for CO2. Therefore, many groups have reported the potential of electrocatalysts to convert CO2 into useful products such as formaldehyde, methanol, methane, carbon, formic acid, and more.12 This has been suggested as one of the ways to reduce the amount of CO2 in the environment which is hoped to reverse the effects of global warming and climate change.
Reaction pathway | Potentiala (vs. SHE/V) |
---|---|
a Equilibrium potential at 25 °C and 100 kPa, proton activity of 1 mol L−1. SHE = standard hydrogen electrode. | |
CO2 + 4H+ + 4e− → C + 2H2O | 0.210 |
CO2 + 2H2O + 4e− → C + 4OH− | −0.627 |
CO2 + 2H+ + 2e− → HCOOH | −0.250 |
CO2 + H2O + 2e− → HCOO− + OH− | −1.028 |
CO2 + 2H+ + 2e− → CO + H2O | −0.106 |
CO2 + H2O + 2e− → CO + 2OH− | −0.934 |
CO2 + 4H+ + 4e− → CH2O + H2O | −0.070 |
CO2 + 3H2O + 4e− → CH2O + 4OH− | −0.898 |
CO2 + 6H+ + 6e− → CH3OH + H2O | 0.016 |
CO2 + 5H2O + 6e− → CH3OH + 6OH− | −0.812 |
CO2 + 8H+ + 8e− → CH4 + 2H2O | 0.169 |
CO2 + 6H2O + 8e− → CH4 + 8OH− | −0.659 |
2CO2 + 2H+ + 2e− → H2C2O4 | −0.500 |
2CO2 + 2e− → C2O42− | −0.590 |
2CO2 + 12H+ + 12e− → CH2CH2 + 4H2O | 0.064 |
2CO2 + 8H2O + 12e− → CH2CH2 + 12OH− | −0.764 |
2CO2 + 12H+ + 12e− → CH3CH2OH + 3H2O | 0.084 |
2CO2 + 9H2O + 12e− → CH3CH2OH + 12OH− | −0.744 |
Herein, we report the electrochemical behaviour of CO2 reduction on roughened molybdenum (Mo) microdisk electrodes which were prepared via mechanical polishing. Therefore, the innovative part of the work presented herein is the preparation of roughened Mo microdisk electrodes using silicon carbide papers which are utilised to assess the electrochemical behaviour of dissolved carbon dioxide in aqueous solutions. To the best of our knowledge, there is no group that has studied the electrochemical behaviour of CO2 on this type of microelectrode. Roughening the microelectrode surface by mechanical polishing method can increase the amount of active sites to improve both sensitivity and response time without expensive surface modifications.13 This work introduces a low-cost and convenient method for the fabrication of roughened Mo microdisk electrodes. Microdisk electrodes are well-known for their unique characteristics such as low ohmic drop, high signal-to-noise ratio, fast response time, and high spatial resolution. Therefore, it would be interesting to assess the voltammetric features of dissolved CO2 on roughened Mo microdisk electrodes.
To confirm that there was no contamination coming from the abrasive materials, an elemental analysis was conducted on virgin, smoothen, and roughened wires using an X-ray diffractometer (XRD, PANalytical X-Pert Pro). XRD spectra were collected from the wires that were sealed inside the epoxy resins without the hollow borosilicate tubes for both smoothened and roughened wire. As for the virgin sample, the XRD pattern was recorded on the commercially available wire in its original state. This study was performed to make sure that the reduction of CO2 was not influenced by the presence of contaminants on the surface of the exposed electroactive materials especially from the abrasive materials.
The electrochemical behaviours of CO2 reduction were assessed on smooth and roughened Mo microdisk electrodes in 0.5 M KCl at 10 mV s−1. A scan rate study was also conducted using the roughened Mo microdisk electrodes where CVs were recorded in 0.5 M KCl at different scan rates: 10, 20, 50, 100, 200, 500, and 1000 mV s−1. Other than that, voltammetric responses were also obtained after bubbling the electrolyte solutions with CO2 gas for different periods of time.
Fig. 1 The optical microscope images of the (A) smoothened and (B) roughened electrode tip taken at 100× magnification. The red circle refers to the wire in the epoxy resin. |
Fig. 1(A) shows a smooth surface of the electrode tip. There are a few fine lines which could be coming from foreign matters with large dimensions present on the electrode surface or the alumina lapping films during polishing. There are also a few dents in the epoxy resin which could be coming from small bubbles formed during mixing. However, these features are acceptable as they will not affect the electroactive area or the electrochemical process. As expected, the electrode tip that was polished with the roughest abrasive material exhibits many scratches with a few dents as shown in Fig. 1(B). This is to show the effect of using polishing materials with different grades on the epoxy resin. The next section discusses the morphology of the electroactive area.
Some fine scratch lines and bumps can be seen clearly on the smooth electrode surface as shown in Fig. 2(A) which implies that it was thoroughly polished. However, Fig. 2(B) demonstrates a very rough surface with a few defects on the surface of Mo wire. Meanwhile, the hardened epoxy resin has a rougher surface than the Mo wire with crumble- and flake-like structures. Nonetheless, this process did not expose the side of the wire which could increase the electroactive area. SEM images for both smoothened and roughened Mo wires taken at 8000× are provided in Fig. 3.
Small scratches can clearly be seen on the smoothened Mo wire in Fig. 3(A) as previously observed in Fig. 2(A). In addition, some surface defects such as small pits and dents can also be observed in the figure. These surface features are typical even after polishing with the lowest grade of polishing materials.14,15 The scratch marks for roughened Mo microelectrodes can be seen clearly on the surface of the wire as shown in the SEM image in Fig. 2(B). On average, the scratch lines on the smoothened and roughened Mo wires have the width of around 90 and 140 nm respectively. Fig. 2(B) also shows that the surface of Mo wire was also uneven with many small steps and dents unlike the smoothened microelectrode. This feature may provide more active sites on the electroactive surface.
Fig. 4 The XRD patterns for Mo microdisk electrodes that were polished with (A) 500 and (B) 25000 grits polishing materials including one for a (C) Mo parent metal without polishing. |
The XRD spectrum recorded for the roughened Mo wire is similar to that of smoothened Mo electrodes in terms of the locations of the peaks. When compared to the XRD spectrum of Mo wire without any modifications, the pattern is also fairly similar to both spectra shown in Fig. 4. This suggests that the polishing material can be thoroughly cleaned from the electrode surface and they do not change the composition of the electrode materials during polishing. Both silicon carbide papers and alumina lapping films only change the morphology of the electrode surface. Therefore, the electroreduction of dissolved CO2 discussed in the next section can be said to be solely coming from the interaction between the electroactive material and dissolved CO2 molecules.
There is a difference between the CVs obtained in the presence and absence of dissolved CO2 for both smoothened and roughened Mo microdisk electrodes. This implies that the reduction peaks are coming from the electroreduction of dissolved CO2. However, the voltammogram recorded using the roughened electrode surface seems to show a higher electrocatalytic activity than the smoothened electrode surface. The foot of the reduction wave for the smoothened electrode surface is at around −0.6 V vs. SCE whereby the one for the roughened surface is at approximately −0.3 V vs. SCE. This could be due to a higher amount of active sites on the roughened electrode surface. It can also be observed that there are two reduction waves for the voltammetric response obtained using the electrode polished with the 500 grit abrasive materials where the first peak is at approximately −0.65 V vs. SCE and the second peak is at around −0.9 V vs. SCE. Most of the reduction peaks reported for the reduction of dissolved CO2 in aqueous solutions are beyond −1 V vs. SCE.16 For example, the reduction wave for the dissolved CO2 in a 0.2 M Na2SO4 solution on phosphorus-doped polycrystalline diamond electrodes was at approximately −1.64 V vs. SCE as reported by Naragino and colleagues.17 This suggests that the roughened Mo microdisk electrodes may have a higher electrocatalytic activity than the phosphorus-doped polycrystalline diamond electrodes for the reduction of dissolved CO2 in aqueous solutions. The electrochemical CO2 reduction does not require a high driving force when using roughened Mo microdisk electrodes as compared to the phosphorus-doped polycrystalline diamond electrodes. Another notable feature is that the limiting current for the dissolved CO2 obtained on the roughened Mo microdisk electrodes is around −18 nA at −0.9 V vs. SCE after subtracting it with the background current which is still larger than that recorded with a smoothened microdisk electrode which is around −3 nA at −0.9 V vs. SCE.
The concentration of any analytes can be approximated by the following mathematical equation which is specifically used for microelectrodes: ilim = 4nFDCa where ilim is the limiting current (Ampere), n is the number of electrons transferred, F is the Faraday constant (96485 C mol−1), D is the diffusion coefficient of the analyte of interest (cm2 s−1), C is the concentration of the analyte (mol cm−3), and a is the radius of the electrode (cm).18 The diffusion coefficient of CO2 can be affected by several factors which include the concentration of test solution, temperature, and pressure.19 The diffusion coefficient of CO2 in 0.5 M KCl is approximately 1.76 × 10−5 cm2 s−1.20 Assuming that the number of electrons transferred is 2, the concentration of dissolved CO2 in the solution is 0.00424 M. As described in the introduction section, the electroreduction of dissolved CO2 can proceed via different pathways. The work presented herein is mainly to report on the electrochemical behaviour of dissolved CO2 on roughened Mo microdisk electrodes. Therefore, the product(s) of the electrochemical processes were not determined via any techniques such as chromatography so as to confirm the pathways taken by the reduction of dissolved CO2 on the roughened Mo microdisk electrodes.
The harsh treatment to roughen the electrode surface could not have exposed the side of Mo wire that could increase the electrode surface and lead to a larger peak current as evident from the SEM image shown in Fig. 2(B). This implies that the higher peak current for the roughened microdisk electrode could be more likely to be caused by an increase in the amount of active sites on the electrode surface as there are many defects such as steps and dents introduced on the surface as seen in Fig. 2(B) and 3(B). Although the position of the peaks in the XRD spectrum for the roughened Mo microdisk electrodes shown in Fig. 4(A) is similar to that for the pristine Mo wire which means that the crystal lattice did not change even after the harsh treatment, there was a significant difference in the intensity of the XRD signal between the Mo microelectrode polished with the 500 grit of abrasive material and the pristine wire which is also akin to the study reported by Zhang and colleagues.21 They reported that the samples with surface and subsurface defects have a lower signal intensity than the samples without defects when analysed using XRD. In our case, the signal intensity for the roughened Mo microdisk electrodes is lower than that for the pristine Mo wire which is an indicator for the presence of defects on the surface of the roughened electrodes. Therefore, the presence of defects such as pits and dents on the electrode surface of the roughened electrodes, which lowered the XRD peak intensity, could increase the number of active sites for the electroreduction of dissolved CO2. The electrochemical surface area (ECSA) was also assessed for the roughened and smoothened Mo microdisk electrodes by following the method that has been described by Trasatti and Petrii.22 The double layer capacitance calculated for the roughened and smoothened Mo microdisk electrodes were 514.79 and 249.65 nF respectively which were determined from the plots of current as a function of scan rate as depicted in Fig. S1.† Meanwhile, the ECSA of the electrodes which were determined from the double layer capacitance values for the roughened and smoothened Mo microelectrodes were 0.00858 and 0.00416 cm2 respectively. These values imply that the roughened Mo microelectrodes have a higher ECSA than the smoothened Mo microelectrodes which could be due to the defects introduced on the former electrodes.
The electrode tip was also polished with 500 grit for 3 minutes, but the current measured at −0.9 V vs. SCE is still around −18 nA (data not shown herein). This could mean that the surface of the electrode may be similar even after polishing the electrode with silicon carbide paper for a longer time. It is sufficient to just polish the electrodes for 1 minute to roughen the electrodes. Therefore, the electrodes were polished only for 1 minute. This finding is fairly beneficial due to the fact that the rough surface of silicon carbide paper could gradually reduce the length of electrode tip and wires during polishing.
It can be seen from Fig. 6(A) that the magnitude of the current increases as the scan rate increases. At slow sweep rates, plateau regions could be seen on the voltammograms as demonstrated in Fig. 5 which corresponds to the hemispherical diffusion on microelectrodes. On the contrary, the reduction peaks recorded at fast scan rates do not exhibit the characteristic shape of voltammograms for microdisk electrodes even though the peak currents increase systematically. In principle, this could be attributed to planar diffusion control. A linear relationship between the current and the square root of scan rates as shown in Fig. 6(B) suggests that the reduction of dissolved CO2 on roughened Mo microdisk electrodes may not involve surface adsorption processes. The correlation coefficient that was obtained from the linear fitting is 0.993. This analysis is further corroborated by the plot of the peak currents vs. scan rate where the peak currents are not proportional to the scan rate as shown in the inset of Fig. 6(B).
Fig. 7 CVs (3rd cycle) of a roughened 25 μm ∅ Mo microelectrode in 0.5 M KCl for 0.01 V s−1 with different CO2 bubbling time: 10 (green), 30 (blue), and 60 min (red). |
The reduction peak for the 10 minutes of bubbling time is less than those for above 30 minutes of bubbling time. In fact, the CV for the roughened Mo microdisk electrode shown in Section 3.4 which was recorded after gassing the solution for 20 minutes also had a fairly similar peak currents to those CVs recorded after bubbling the test solution with CO2 gas for more than 30 minutes; their peak currents are approximately −18 nA taken at −0.9 V vs. SCE. The similarity in the peak currents suggests that 20 minutes was adequate to saturate the solution under the stated conditions. This is assuming that the gas flow rate remains the same throughout the experiment as a manual gas flow meter was used. Other than that, it was also assumed that other gases were not able to seep into the solution throughout the experiment as N2 gas was gently flowed to cover the surface of the solution without introducing disturbance. Moreover, the solution should contain no other gases as the solution was purged with N2 gas prior to the introduction of CO2 gas. As purified chemicals were used and each glassware was cleaned thoroughly, no contaminant should be present which could affect the test solution concentration and gas dissolution. The experiment was also performed at room temperature and pressure. Nonetheless, the time needed to saturate the solution with the analyte gas would also depend on the type and concentration of the electrolyte and the flow rate of the gas. This study is important to show the electrochemical response for different concentrations of CO2 which could open more research opportunities on enhancing the electrochemical performance of the electrode material.
Footnote |
† Electronic supplementary information (ESI) available. See DOI: https://doi.org/10.1039/d3ra05592b |
This journal is © The Royal Society of Chemistry 2023 |