Additive-manufactured paper–PMMA hybrid microfluidic chip for simultaneous monitoring of creatinine and pH in artificial urine

Abstract

Nowadays, kidney dysfunction is a common health issue due to the modernized lifestyle. Even though medications are commercially available to treat kidney diseases, early diagnosis is crucial and challenging. Clinically, measuring urine creatinine and pH has gained significant interest as a way to diagnose kidney diseases early. In the present work, we attempted to develop a low-cost, robust, accurate and naked-eye colorimetric method to determine both creatinine levels and pH variations in artificial urine samples using a simple 3D-printed hybrid microfluidic device. Creatinine was detected by the incorporation of the traditional Jaffe test onto the hybrid paper–PMMA microfluidic device and pH (4–8) was measured by a simple anthocyanin test. Notably, the tests were established without employing any sophisticated or costly instrument clusters. The developed 3D-printed microfluidic probe showed a limit of detection (LOD) of 0.04 mM for creatinine over a concentration range of 1–10 mM, with a regression coefficient (R2) of 0.995 in laboratory conditions. Interestingly, the experimental data obtained with artificial urine exhibited a wide linear range from 0.1 mM to 5 mM under different pH values ranging from 4 to 8 in the presence of matrices commonly found in urine samples other than proteins, indicating the potential use of this method in pre-clinical analysis. Since the wide linear range of urine creatinine in artificial urine samples falls well below the clinically relevant concentrations in humans (0.07–0.27 mM), the developed lab-on-chip device is further suitable for clinical evaluation with proper ethical clearance. This 3D-printed hybrid microfluidic colorimetry-based creatinine detection and pH indicator platform can be beneficial in the healthcare sector due to the on-site testing capability, cost-effectiveness, ease of use, robustness, and instrument-free approach.

Graphical abstract: Additive-manufactured paper–PMMA hybrid microfluidic chip for simultaneous monitoring of creatinine and pH in artificial urine

Supplementary files

Article information

Article type
Communication
Submitted
05 Jun 2024
Accepted
23 Jun 2024
First published
25 Jun 2024

Analyst, 2024,149, 3882-3890

Additive-manufactured paper–PMMA hybrid microfluidic chip for simultaneous monitoring of creatinine and pH in artificial urine

A. S. Sheeraz, E. Aiswarya, B. N. Kumara, J. Sonia, R. V. Rodrigues, N. Sheikh, S. Vidyasagar, Rachana. A. Kunder, S. Elangovan, P. S. Mohanty and K. S. Prasad, Analyst, 2024, 149, 3882 DOI: 10.1039/D4AN00796D

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements