Elahe
Ghorbanian
a,
Forough
Ghasemi
*b,
Kamran Rezaei
Tavabe
a and
Hamid Reza
Alizadeh Sabet
c
aDepartment of Fisheries, Faculty of Natural Resources, University of Tehran, Karaj, Iran
bDepartment of Nanotechnology, Agricultural Biotechnology Research Institute of Iran (ABRII), Agricultural Research, Education, and Extension Organization (AREEO), Karaj, Iran. E-mail: forough.ghasemi@abrii.ac.ir
cInternational Sturgeon Research Institute, Iranian Fisheries Science Research Institute, Agricultural Research, Education, and Extension Organization (AREEO), Rasht, Iran
First published on 14th May 2024
Due to the expansion of the aquaculture industry in the world and the importance of controlling ammonia in fish breeding water, high levels of which impose significant damage to fish farming, it is crucial to develop affordable, rapid, and on-site methods for timely and accurate detection of ammonia. In this study, a colorimetric sensor based on the formation of gold/silver core/shell nanorods (NRs) was developed for the rapid detection of ammonia. The sensor functioned by the specific dissolution of silver(I) oxide by ammonia, which triggered the activation of silver ions and the subsequent formation of gold/silver core/shell NRs in the presence of a reducing agent (i.e., ascorbic acid (AA)). This led to changes in the surface composition, size, and aspect ratio of the NRs, which was accompanied by a vivid color change from green to red/orange in less than a minute. The colorimetric sensor was optimized by adjusting the effective parameters, including ascorbic acid, silver ion, and sodium hydroxide concentration as well as pH and reaction time. After the optimization process, the sensor was found to have a linear range from 50 to 800 μmol L−1 (0.85–13.6 ppm). In addition, the application of the sensor was validated by measuring the ammonia content in water samples from rearing ponds for rainbow trout, sturgeon, and tilapia before and after feeding. The sensor's label-free, rapid, user-friendly, naked-eye, and cost-effective operation makes it an attractive option for on-site environmental monitoring of ammonia.
Ammonia is a pollutant that is frequently found in aquatic ecosystems. In closed aquaculture systems, however, the accumulation of ammonia is a critical challenge. This is all the more true as ammonia levels tend to rise due to the accumulation of fish waste and the decomposition of excess feed.4 This compound occurs in nature, but is also introduced by sewage, industrial waste, and agricultural runoff.5 Even low concentrations of dissolved ammonia can have a negative effect on aquatic life, as it is a harmful chemical compound. Ammonia is the most important toxic pollutant in fish tank wastewater.6 In fish, ammonia can lead to physical damage, behavioral changes, and even death.7 The tolerance of fish species to ammonia varies according to their physiological status.8 Maintaining adequate water quality in aquaculture is therefore crucial, and controlling ammonia concentrations is particularly important. However, measuring the ammonia content can be difficult and expensive. It requires specialized equipment and trained professionals, which can be a major hurdle for many aquaculture producers.
A number of techniques have been developed to regulate and monitor ammonia concentrations, including the Nessler and Indophenol Blue (IPB) methods. However, for reasons of environmental protection and the need to detect low concentrations, these methods are not recommended.9 The indophenol blue method is based on the indophenol or Berthelot reaction.4 Nessler's method uses mercury, which must be disposed of as hazardous waste. The ammonium salicylate test method is more expensive and slower. This test generates sodium nitroferricyanide and must be disposed of as hazardous waste. Ammonia can also be measured with ion electrodes. With this method, it is important to know the water temperature, pH and salinity in order to evaluate the results of ammonia.7 Furthermore, the purchase of these devices involves additional costs, e.g. for calibration solutions, cables, and additional sensors, which makes them costly and impractical for small aquaculture producers. In addition, delays in testing can lead to fluctuations in ammonia levels and thus affect the test results.4 As it is important to detect low levels of ammonia quickly, it is essential to develop methods that are both efficient and easy to use. In this research, a fast, simple, and inexpensive colorimetric method without hazardous waste disposal was developed using plasmonic nanorods to measure ammonia.
Plasmonic nanostructures of gold and silver are considered as efficient sensing elements due to their unique photophysical properties, size-dependent optical changes, simplicity, and high sensitivity in colorimetric measurement of various chemical species.10–12 One of the most important and widely used properties of plasmonic nanoparticles is their surface plasmon resonance (SPR) phenomenon. The reason for this phenomenon is the combined oscillation of conduction electrons on the metal surface, which is triggered by exposure to light and leads to intense absorption in the visible electromagnetic spectrum. As a result, the solution of nanoparticles appears in a vivid color.13,14 The surface plasmon resonance leads to extremely high absorption and scattering properties in the visible wavelength range, which gives the particles a higher sensitivity than conventional organic dyes and makes them suitable for use as colorimetric sensors.15–22
In this study, gold nanorods (AuNRs) were used, which exhibit two distinct surface plasmon resonance peaks: the transverse peak at approximately 520 nm and the longitudinal peak, which varies from the visible to the near-infrared absorption range depending on the aspect ratio (AR) of the AuNRs. As the AR decreases, the longitudinal peak of the SPR shifts to shorter wavelengths, resulting in a blue shift and a vivid color change. Therefore, AuNRs are very promising for applications as signal transducers in the development of sensors and biosensors.23–26 In general, AuNRs are used in sensor design based on various mechanisms, including etching and formation/growth.27 In growth-based methods, the analyte directly or indirectly reduces metal ions and forms core/shell nanoparticles.28 In the present study, we have utilized the growth mechanism and the design of the sensor is based on the specific dissolution of silver(I) oxide by ammonia, which triggers the activation of silver ions and the subsequent formation of core/shell gold/silver nanorods in the presence of ascorbic acid (AA) as a reducing agent (Scheme 1). This leads to changes in the surface composition, size and aspect ratio of the AuNRs in the plasmonic ribbon, which are accompanied by vivid color changes in the solution. As far as we know, there are no previous reports of a nanosensor for rapid detection of ammonia in multiple colors.
To prepare AuNRs, 10 mg of 5-BrSA was added to a 5.0 mL solution of CTAB (0.1 mol L−1). After complete dissolution, a volume of 96 μL of a 0.01 mol L−1 AgNO3 solution was added. After 15 minutes of gentle stirring at room temperature, 5.0 mL of a HAuCl4 solution (0.001 mol L−1) was added. After 50 minutes, 26 μL of a solution containing 0.1 mol L−1 AA was added to the mixture and stirred vigorously for 1 minute. Finally, 16 μL of the primary seed solution was injected into the above solution and stirred for 30 s. Then, it was allowed to stand undisturbed at room temperature for 12 hours. A brown hue gradually developed in the solution and AuNRs with transverse and longitudinal peaks at 522 and 728 nm, respectively were synthesized.29
In the next step, the performance of the sensor was evaluated in real samples, including water from the campus and tap water, as well as water samples from rainbow trout, sturgeon, and tilapia rearing ponds. The water from the sturgeon pond and the inlet was taken from the ponds of the International Sturgeon Research Institute, Rasht, Iran. The water for tilapia and trout farming was taken from the Fisheries Workshop of the Faculty of Agriculture and Natural Resources of Tehran University in Karaj, Iran. All samples were used immediately after passing through filter paper.
C6H8O6 + 2Ag+ → C6H6O6 + 2Ag0 + 2H+ | (1) |
2Ag+ + 2OH− ↔ Ag2O(s) + H2O | (2) |
Ag2O(s) + 4NH3(aq) + H2O ↔ 2[Ag(NH3)2]+(aq) + 2OH− | (3) |
By adding sodium hydroxide to the silver ions, the silver ions form silver(I) oxide (Ag2O) (eqn (2)), which inhibits the formation of a silver shell on the surface of the AuNRs (Fig. 2a, C: blue line). It should be noted that in the same condition of the sensor, the inhibitory effect of other anions such as phosphate, sulfate, chloride, and bromide was also investigated and none of them inhibited the activity of silver ions. As Fig. 2b shows, core/shell NRs were prepared in the presence of all anions except hydroxide.
The presence of ammonia specifically caused the dissolution of silver(I) oxide and the activation of silver ions (eqn (3) and Fig. 2a, D: green line). It is worth noting that this part of the chemistry behind the design principle was based on the well-known Tollens' reagent, in which only ammonia can dissolve silver oxide. Therefore, in the presence of ammonia, gold/silver core/shell AuNRs were formed and a vivid color and spectral change was observed in the probe (Scheme 1 and Fig. 2a). The formation of the core–shell nanorods was confirmed by acquiring TEM images before and after the addition of ammonia to the sensor (Fig. 2c and d). In the presence of ammonia, a decrease in the aspect ratio of the AuNRs from 3.6 to 2.8 was observed, indicating the deposition of a silver layer on the surface of the AuNRs.
Following the satisfactory initial results, various parameters affecting the sensor's response to ammonia were optimized to achieve the highest sensitivity of the sensor. In all experiments, the maximum wavelength difference between the blank and the ammonia sample (λ0 − λ) was used as the response of the sensor.
In the next step, the concentration of coating material, i.e., silver ions was optimized as a crusial parameter. With an increase in the silver ion concentration, which can be attributed to an increase in the thickness of the silver layer, a corresponding increase in the blue shift of the plasmon peak was observed (Fig. 3c). At a silver ion concentration of 260 μmol L−1, the magnitude of the plasmon peak shift was fixed (Fig. 3d), so the concentration of 260 μmol L−1 silver ions was chosen as the optimal concentration for further experiments.
In the presence of sodium hydroxide, silver(I) oxide (Ag2O) is formed (eqn (2)), which inhibits the formation of a silver shell on the surface of the AuNRs. Therefore, the concentration of hydroxide ions was optimized as an inhibitor for the formation of gold/silver core/shell NRs. As shown in Fig. 3e, as the hydroxide ion concentration increased, the amount of core–shell nanoparticles formed decreased until the inhibition was as high as possible at a concentration of 2.5 mmol L−1 (Fig. 3f). Therefore, the concentration of 2.5 mmol L−1 sodium hydroxide was chosen as the optimum concentration.
As eqn (1) illustrates, reducing silver ions and consequently forming core/shell NRs is pH-dependent. Initial experiments revealed that the rate of silver metallization is low at pH values below 7.0. Therefore, the experiments were done at basic pHs. Among different tested buffers, the carbonate–bicarbonate buffer had no interferences with the responses. Carbonate–bicarbonate buffer is an effective buffer in the range of 9.2–10.6. Therefore, pH was investigated in this range using the carbonate–bicarbonate buffer. According to Fig. 4a, the highest response of the sensor was observed at a pH of 9.6 and remained constant thereafter. Therefore, all subsequent experiments were carried out at a pH value of 9.6.
To achieve the maximum response in the shortest possible time, we tested three times, including inhibition, recovery and analysis times, which could affect the response of the sensor. By combining hydroxide and silver ions and recording the response of the sensor at different times, the inhibition time was investigated. Based on the results shown in Fig. 4b, the reaction between hydroxide and silver ions to form silver(I) oxide was already completed by mixing. Therefore, we used the mixture of hydroxide ions and silver ions immediately after mixing.
The recovery time was then optimized. For this purpose, ammonia was added to the deactivated silver solution (the mixture of silver and hydroxide). As can be seen in Fig. 4c, ammonia dissolves the silver oxide in the first few seconds and thus reactivates the silver ions. Therefore, the mixture of ammonia and silver oxide was used as soon as it was completely mixed.
Finally, the analysis time was investigated. For this purpose, a mixture of ammonia or a control sample (without ammonia) and silver/hydroxide was added to a mixture of AuNRs/ascorbic acid and UV-Vis spectra were recorded. As Fig. 4d shows, the formation of the core/shell nanorods is completed within the first few seconds. Therefore, in all subsequent experiments, spectra were recorded 30 seconds after complete mixing of the sensor components to ensure repeatability of the sensor reaction.
Ammonia concentration is one of the most important parameters to control in water. Given the expansion of the aquaculture industry and the potential negative impact of ammonia on economic development and human health, as well as its ability to harm aquatic animals and damage farming communities, the accurate measurement and control of ammonia levels in fish farm waters is critical. To ensure sustainable use of water resources and to protect aquatic life from the harmful effects of ammonia, it is also crucial to detect and monitor ammonia levels in various water bodies such as breeding ponds. Therefore, the practicality of the developed probe was evaluated by detecting ammonia in various water samples, such as tap water, campus water and water from fish breeding ponds. The developed probe was used to test samples spiked with 0.6 mmol L−1 ammonia. The results summarized in Table 1 show the feasibility of the developed probe for the determination of ammonia in different samples. In addition, the results are comparable with the standard spectroscopic method according to Nessler. The calibration curve with the Nessler method and the colors of the sensor are shown in Fig. 6b. The Nessler method uses mercury, which is a toxic substance for animals, humans and the environment. However, we used non-toxic, unmodified AuNRs and a growth mechanism that enables colorimetric responses for rapid ammonia detection with the naked eye.
Sample | Initial concentration (mmol L−1) | Spiked (mmol L−1) | Method | Found (mmol L−1) | Recovery (%) |
---|---|---|---|---|---|
Tap water | 0.0 | 0.6 | This work | 0.591 | 98.5 |
Nessler | 0.629 | 104.8 | |||
Campus water | 0.0 | 0.6 | This work | 0.587 | 97.8 |
Nessler | 0.615 | 102.5 | |||
Pond water (sturgeon) | 0.033 | 0.6 | This work | 0.576 | 90.5 |
Nessler | 0.636 | 100.5 | |||
Inlet water (sturgeon) | 0.017 | 0.6 | This work | 0.588 | 95.2 |
Nessler | 0.573 | 92.7 | |||
Pond water (rainbow trout) | 0.007 | 0.6 | This work | 0.583 | 96.0 |
Nessler | 0.624 | 102.8 | |||
Pond water (rainbow trout) | 0.010 | 0.6 | This work | 0.621 | 101.8 |
Nessler | 0.623 | 102.2 | |||
Pond water (rainbow trout) | 0.021 | 0.6 | This work | 0.587 | 94.3 |
Nessler | 0.607 | 97.7 | |||
Pond water (tilapia) | 0.031 | 0.6 | This work | 0.612 | 96.8 |
Nessler | 0.614 | 97.2 |
Spectrophotometric methods based on plasmonic nanoparticles that have been reported for the measurement of ammonia are listed in Table 2. The detection limit of ammonia in the present study is lower than the reported methods.1,31–34,36–39 Most reports do not provide visual detection1,30–34,36,39 or clear color differentiation.35,38 In the present study, the color changes of the sensor in the absence and presence of different ammonia concentrations are completely different and can be easily detected by the naked eye. In addition, some of the reported methods require the functionalization of nanoparticles, which makes the fabrication process of the sensor more complicated and time-consuming. However, in the current research, there is no need to modify or functionalize the surface of the nanoparticles. Moreover, some reports are based on specific fruits and plants,31,33,36 which are only cultivated in a few countries. Therefore, they are expensive and not available.40
Nanoprobe | LOD (ppm) | Linear range (ppm) | Response time | Ref. |
---|---|---|---|---|
Poly(amidoamine)-coated superparamagnetic iron oxide NPs decorated with AgNPs | 5.69 | 10–50 | 2 h | 30 |
AgNPs synthesized by Durian fruit shell | — | 500–3000 | 3.5 h | 31 |
AgNPs synthesized by 3-(1-(2-(2,4-dinitrop henyl)hyd razono)ethyl)-1H-indole | 17 | 8–200 | 30 s | 1 |
AgNPs synthesized by cyanobacterium Haloleptolyngbya alcalis | — | 50–500 | — | 32 |
AgNPs synthesized by fruit extract of Terminalia chebula | — | 5–100 | 15 min | 33 |
Core–shell amino-terminated hyperbranched chitosan NPs-AgNPs | 8.0 | 10–50 | — | 34 |
Au@Ag NPs | 0.11 | 0.85–27.2 | 12 min | 35 |
AgNPs synthesized by Durenta erecta fruit extract NPs | 0.5 | 5–100 | — | 36 |
AgNPs synthesized by poly(methacrylic acid) (PMA) | — | 5–100 | — | 37 |
AgNPs synthesized by polyvinylpyrrolidone | 180 | 200–1000 | 20 s | 38 |
AuNRs | 0.75 | 0.85–13.6 | 30 s | This work |
This journal is © The Royal Society of Chemistry 2024 |