Nabashree
Chakraborty†
,
Akshay
Silswal†
and
Apurba Lal
Koner
*
Bionanotechnology Lab, Department of Chemistry, Indian Institute of Science Education and Research Bhopal, Bhopal Bypass Road, Bhauri, Bhopal-462066, Madhya Pradesh, India. E-mail: akoner@iiserb.ac.in
First published on 21st February 2024
Fluorescent molecular rotors incorporating julolidine have found diverse applications in various fields. Recently, researchers have explored their utility in polymerization, metal ion detection, self-assembly, aggregation, and detection of proteins and nucleic acids. These julolidine-based molecular rotors primarily serve as fluorescent turn-on probes, showcasing their effectiveness in sensing local environmental properties such as polarity, pH, viscosity, protein folding, and misfolding. This comprehensive review covers an array of julolidine-based fluorescent molecular rotors, along with their pertinent uses in the field of biological research and monitoring changes in the microenvironment through solvent dielectric constant, viscosity, self-assembled polymers, and submicrometer-sized membrane-bound compartments in live cellular systems. The discourse supports ongoing research concerning their diverse applications and provides a forward-looking perspective on their potential advancements.
The FMR is a type of molecule that can experience intramolecular rotation when exposed to light. If this rotation is unrestricted, the molecules will return to their ground state from an excited state through non-radiative pathways. However, if the rotation is limited by factors such as the viscosity of the surrounding environment, the molecules will exhibit increased fluorescence. Molecular rotors encompass a diverse class of molecules that exhibit non-radiative decay mechanisms beyond TICT. These rotors typically consist of a fluorophore attached to a conjugated moiety capable of rotational motion relative to the entire molecule (Fig. 1). Moreover, some molecular rotors leverage this rotational motion to induce dimer emission, contributing to their distinct classification within this category. The class of FMRs consists of three subunits: an electron donor, an electron acceptor, and an electron-rich conjugated linker that has alternating single and double bonds, and will be discussed here. Upon photoexcitation, these molecules undergo a TICT state, which has a lower energy in the excited state. This twisting facilitates intramolecular charge transfer between the donor and acceptor, resulting in the creation of a charge-separated state as electrons transfer from the donor to the acceptor. This charge separation is highly polar and is significantly stabilized by polar solvents. The relaxation of the molecule from this state can lead to either red-shifted emission or non-radiative relaxation, depending on the molecular structure. Incorporating certain parameters enhances the TICT effect. These parameters include increasing the electron donor strength, initial twisting of the molecule, increasing the electron acceptor strength, and engineering the bridge. Manipulating these factors allows for tuning the TICT phenomenon. In this review, we discuss julolidine-based molecular rotors and their diverse applications since 2014.
The molecule 9-(dicyanovinyl)-julolidine (DCVJ) is widely known for its fluorescence properties that are dependent on viscosity. Prof. Theodorakis and co-workers have extensively worked with 9-(2-carboxy-2-cyanovinyl) julolidine (CCVJ) and DCVJ-based molecular rotors for various applications.14–18 They are commonly used for measuring viscosity in cell membranes of liposomes, monitoring polymerization processes, and tubulin remodeling. However, when using DCVJ for measuring membrane viscosity, there are often challenges, such as poor water solubility and a tendency to bind serum proteins. This can result in protein-bound DCVJ leaking into the cytoplasm and causing a background signal. To address this issue, Haidekker et al. modified the nitrile group of DCVJ with esters containing different alkyl chains. This alkyl substitution improved the localization of the molecule in the membrane. The probe with farnesyl substitution (farnesyl-(2-carboxy-2-cyanovinyl)-julolidine, FCVJ) exhibited better viscosity-sensitive properties and improved photostability compared to DCVJ. Additionally, the research group developed a ratiometric fluorescence approach to quantify viscosity. They combined the polarity-insensitive CMAM (2-cyano-3-(4dimethylaminophenyl) acrylic acid methyl ester) with the polarity-sensitive MCCA (7-methoxycoumarin-3-carboxylic acid) to create a ratiometric fluorescence response. In this approach, CMAM acts as a donor to excite MCCA, which serves as a sensor for viscosity through resonance energy transfer. The fluorescence intensity of CMAM remains constant and acts as a reference, while MCCA changes in response to viscosity variations. A normalized intensity is obtained by dividing the emission intensity of the sensor by the emission intensity of the reference. This eliminates concentration-related effects and provides a method for quantifying viscosity using an internal reference. Recently, julolidine-based molecular rotors have been utilized for various applications which are discussed in detail.
![]() | ||
Fig. 2 Increasing fluorescence of JP1–R when bound specifically to recombinant Mdm2. (a) Higher Mdm2 concentrations were then added to stable concentrations of rotary–peptide conjugates (JP1–R, JP2–R). (b) JP1–R added to increasing Mdm2 (18–125 residues) EIF4e BSA IGG 50 nM JP1–R; dashed-line indicates background fluorescence only. Reprinted with permission from ref. 19. Copyright 2014. American Chemical Society. |
The fluorescence signal previously observed in the JP1–R–Mdm2 complex was completely eliminated when racemic Nutlin was added, likely due to the displacement of JP1–R from Mdm2. In contrast, the addition of Mdm2 did not cause any significant changes in fluorescence intensity in JP2–R. During the interaction with nonspecific proteins eIF4E, BSA, and IgG, the addition of JP1–R did not result in any fluorescence increase (Fig. 2b) across the same concentration range for all three proteins. The presence of nonspecific proteins led to low levels of rotor activity, indicating potential applicability in complex biological samples. Molecular dynamics simulations suggest that the C-terminal end of JP1–R adopts a helical turn, influenced by the hydrogen bonds between the hydroxyl side chain and backbone of S12, as well as the backbone carbonyl of W8.
The apparent Kd for Mdm2 binding was determined to be 16.01 ± 7.52 nM based on the JP1–R fluorescence measurements. This value correlates well with the previously reported Kd of 18.83 ± 5.03 nM obtained using isothermal titration calorimetry (ITC). In order to further confirm the binding of JP1–R, we conducted ITC experiments and obtained a Kd of 10.2 ± 7.97 nM, which is consistent with the fluorescence-based measurement. On the other hand, the calculated apparent Kd for JP2–R was found to be 3365 ± 640.6 nM, which is approximately 14-fold lower than the previously reported value of 239.81 ± 53.79 nM. The molecular rotor's TICT property is utilized to decrease its free volume when it interacts with a protein. This straightforward fluorescence turn-on signal, triggered by protein binding, enables the creation of sensitive and easy assays to measure protein–ligand binding in a high-throughput manner.
In 2015, Gavvala and his co-workers aimed to examine the fluorescence properties of CCVJ in different environments, such as cyclodextrins (CDs) and human serum albumin (HSA), using the femtosecond fluorescence up-conversion technique.20 The absorption maximum of CCVJ experiences a blue shift in the presence of HSA (Fig. 3a), suggesting that CCVJ binds to HSA. A significant enhancement accompanied with a blue shift in the emission intensity of CCVJ was observed upon HSA binding (Fig. 3b). The calculated binding constant (Ka) between CCVJ and HSA is 1.0 × 105 M−1, indicating a high affinity for binding. The binding of CCVJ with HSA is supported by electrostatic and hydrogen bonding interactions, as the negatively charged E isomer of CCVJ is surrounded by positively charged basic amino acid residues. Based on the findings presented in this paper, it can be inferred that the photo-isomerization process, known as the primary non-radiative decay pathway of CCVJ, is significantly limited within the aforementioned bio-mimetic and biological nano-cavities. Theoretical and molecular modeling studies have explored the potential orientations of CCVJ within the nano-cavities of CDs and proteins.
![]() | ||
Fig. 3 Change in (a) absorption and (b) emission spectra of CCVJ with increasing concentration of HSA. Inset shows the normalized spectra of only CCVJ and with 10 μM HSA. Reprinted from ref. 20. Copyright 2015. Royal Society of Chemistry. |
The Mukhopadhyay group utilized a DCVJ probe for monitoring the oligomerization of human β2 microglobulin (β2m).21 The DCVJ probe binds to early amyloidogenic oligomers and is employed to examine the oligomerization of β2m under varying NaCl concentration at pH 2.5. Additionally, the researchers used DCVJ to observe the rapid formation of early oligomers on the submillisecond time scale employing a stopped-flow mixing device for this purpose.
Lapidus and colleagues utilized DCVJ for detecting the oligomerization of amyloids.22 The introduction of Aβ40 had no discernible impact on the DCVJ fluorescence over a 20-minute period. This could be attributed to either the non-binding of DCVJ to the monomer or the high flexibility of the chain, which did not impede the rotation of bound DCVJ. The ability of DCVJ to discern oligomer structure and packing makes it a suitable probe for detecting the early lag phase of amyloid assembly.
Fares and his co-workers combined a fluorescent molecular rotor CCVJ with a mutated protein domain called AgHalo.23 In non-stressed cells, the sensor remains folded and non-fluorescent. However, when exposed to stress conditions, it becomes fluorescent. This sensor is unique in its ability to detect misfolded proteins that cannot be detected by other existing sensors. This misfolding causes exposure of nonpolar and aromatic residues to a hydrophilic environment. The misfolded proteins are often associated with various diseases. Early detection of misfolded proteins and monitoring their aggregation can provide valuable insights into the progression of diseases and help in the development of therapeutic strategies.
The behavior of the Halo-tag with P1 and P2 ligands is different. P1 is a solvatochromic fluorophore that detects exposed hydrophobic regions of misfolded proteins. It can specifically detect AgHalo in conformations such as soluble oligomers and insoluble aggregates in live cells. However, P1 cannot detect AgHalo monomers that adopt misfolded conformations in cells. P2 is a fluorescent molecular rotor that detects protein aggregation by hindering the rotation of the rotor. When P2 is conjugated to AgHalo, it can detect the formation of misfolded conformations induced by proteome stress. P2 exhibits a higher fluorescence signal when detecting soluble and insoluble protein aggregates induced by more severe proteome stress. P1 detects exposed hydrophobic regions of misfolded proteins, while P2 detects protein aggregation by hindering the rotation of the fluorescent molecular rotor (Fig. 4).
At the end there are few limitations of this study. While the new sensor is more sensitive to misfolded conformations induced by mild proteome stress compared to previous sensors, it may still have limitations in detecting subtle changes in protein conformation. The sensor is designed to detect protein misfolding and aggregation, but it may not be able to distinguish between different types of protein aggregates or accurately identify specific misfolded proteins. The sensor's performance may vary in different cell types or under different cellular conditions, which could affect its ability to accurately detect proteostasis deficiency. The presence of other cellular components or molecules could potentially interfere with the sensor's fluorescence signal, leading to false-positive or false-negative results. While the sensor has been demonstrated in live cells, its applicability in more complex biological systems, such as animal models or human tissues, remains to be explored.
Recently to overcome the aforementioned challenges, Liu and co-workers have reported a dual-color fluorogenic thermal shift assay to measure changes in the melting temperatures of the protein system via bioorthogonal labeling.24 In this assay, CCVJ functions as a fluorescent reporter by conjugating using sortase-tag technology to the target protein. This makes it possible to use two orthogonal fluorescence readouts for simultaneous monitoring of the aggregation of two distinct proteins and for orthogonal detection. CCVJ and another fluorescent rotor i.e., Mero, were utilized for the multi-color detection of protein aggregates with minimal fluorescence cross-talk. The study provided a quantitative analysis on the thermodynamic interplay during protein co-aggregation.
The application of a structurally different molecular rotor in SNAP tag technology was also utilized to visualize intracellular compartments of cells and protein aggregates. Mostly, a 4-hydroxybenzylidene imidazolinone (HBI)-based molecular rotor was appended with O6-benzyl-guanine (BG) for tagging with SNAP protein to achieve a fluorogenic response.25–27
Nath and his colleagues explored the interaction between the molecular rotor DCVJ and DNA.28DCVJ, a neutral molecule, exhibits a significant binding affinity to DNA, primarily attributed to ion–dipole interactions arising from its substantial dipole moment in the ground electronic state. The binding studies by researchers verified that, in addition to ion–dipole interactions, DCVJ forms a binding relationship with DNA through intercalation. This intercalation mechanism induces restriction in its excited-state twisting process, resulting in a substantial enhancement of its emission yield. Molecular docking studies further supported the intercalation mode of binding, revealing strong π–π stacking interactions and hydrogen bonding between DCVJ and guanine bases in DNA as key contributors to the intercalation process. Despite its relatively weak binding, the ultrafast molecular rotors were demonstrated as potential fluorescence sensors for DNA.
In 2023 Mondal and his co-workers presented the development and synthesis of three cationic julolidine–azolium conjugates (OX-JLD (O), BTZ-JLD (S), and SEZ-JLD (Se)) that act as fluorescent probes when interacting with RNA.29 These conjugates exhibit high quantum yields and brightness, making them ideal for intracellular RNA imaging. Herein the authors discussed the design of three cationic julolidine–azolium conjugates that function as fluorescent probes for visualizing RNA in live cells. These probes exhibit a high level of brightness and quantum yields when they interact with RNA. The main focus of the study was to establish the potential use of these probes for intracellular RNA imaging. Among the probes, BTZ-JLD and SEZ-JLD show particularly promising photophysical properties and optical responses towards RNA. BTZ-JLD emits light at a longer wavelength in the red region of the electromagnetic spectrum when it interacts with RNA. These photophysical properties make BTZ-JLD a suitable candidate for fluorescence imaging of intracellular RNA in live cells.
A list of julolidine-based FMRs used for the detection of proteins and nucleic acids is provided in Fig. 5.
![]() | ||
Fig. 6 A new strategy for developing a TICT based FMR for ratiometric sensing of metal ions. R1 and R2 are alkyl/functionalizable alkyl groups. |
The conformational change induced by the binding of Hg2+ ions results in a significant alteration in the emission intensities. This enables the detection of Hg2+ ions even at low concentrations. To investigate the absorption and emission characteristics of compounds PYJO1–PYJO4, experiments were conducted in methanol/HEPES buffer (7:
3) at pH 7.2. Among these compounds, PYJO1 with a methylsulfanyl substitution displayed two absorption bands with peaks at 340 nm and 540 nm (Fig. 7a). However, it did not exhibit any fluorescence in the visible region. Fluorophores PYJO2–PYJO4 display two absorption bands centered at 330 nm and 460–470 nm, corresponding to π–π* and n–π* transitions, respectively. The fluorescence spectra of PYJO2–PYJO4 exhibit two emission bands centered at 481–530 nm (in the green region) and 645–680 nm (in the red region) (Fig. 7b). It is important to note that PYJO4 demonstrates distinct dual emission characteristics, with a strong intensity band in the NIR region, which can be attributed to the effective TICT state.
![]() | ||
Fig. 7 (a) Absorption spectra in the visible light and (b) ratiometric fluorescence spectra with increasing concentration of the metal. Insets show color change upon addition of Hg2+ ions under daylight (for Fig. a) and under UV light (for Fig. b). Reprinted with permission from ref. 30. Copyright 2016. Royal Society of Chemistry. |
The ratiometric response of fluorescence intensities (I530/I665) is enhanced from 0.7 to 4.2, resulting in a final enhancement factor of up to 6-fold. The detection limit is approximately 5.7 × 10−9 M (1.14 ppb). PYJO4-coated test strips offer a potential solution for detecting mercury ions in contaminated water. These strips provide a simple, rapid, and portable method for identifying the presence of toxic mercury ions. When exposed to mercury ions, the test strips undergo a noticeable fluorescence change from red to green, enabling easy visual detection. The sensitivity of the test strips has been demonstrated up to a level of 200 ppb. The successful application of PYJO4 in detecting and imaging intracellular Hg2+ in live MCF-7 breast cancer cells has been demonstrated.
A fluorescent molecular rotor is utilized in a method to detect and measure polystyrene nanoparticles.31 The probe's fluorescence quantum yield is altered when polystyrene nanoparticles are present. In 2021 Moraz and his co-workers were able to successfully detect and measure polystyrene nanoparticles in water, and they also determined the range for detection and quantification for specific nanoparticle sizes.31 This method is significant because it allows for the assessment of the presence and concentration of polystyrene nanoparticles in biological samples and environmental water. These nanoparticles are a major threat to aquatic and terrestrial environments due to their potential to harm wildlife and ecosystems. The study also investigated the influence of temperature and viscosity on the detection and quantification of polystyrene nanoparticles (Fig. 8). The results showed that temperature did not significantly affect the detection and quantification of polystyrene nanoparticles, while viscosity did not affect the fluorescence of DCVJ in the presence of polystyrene nanoparticles. The hydrophobic interaction between DCVJ and the polystyrene nanoparticles was found to be the main factor influencing the detection and quantification of polystyrene nanoparticles.
![]() | ||
Fig. 8 Detection of polystyrene nanoplastic (PSNs) using a DCVJ-based FMR. Reprinted with permission from ref. 31. Copyright 2021. American Chemical Society. |
A new analytical method for detecting and quantifying PSNs using an FMR has been developed. The method uses a three-unit molecular system, DCVJ, a commercially available FMR, to determine the concentration of nanosized plastic beads. The underlying phenomenon is a hydrophobic interaction between the probe and the analyte, rather than the viscosity resulting from the presence of the nanomaterial. The most suitable method is the appearance and increase in a second band at 620 nm due to hydrophobic interactions possibly associated with the excimeric feature within the beads. The surface area and particle size also play a role in the fluorescence. The method is label-free and easy to implement, but further investigation is needed to reach standardization for routine analysis. This work presents the feasibility of quantifying PSNs using DCVJ fluorescence and opens new perspectives in this field.
![]() | ||
Fig. 9 (a) Schematic representation of monitoring the phase transition of a unimer micelle to multichain aggregates using JCBF as a molecular rotor, and (b) emission spectra of JCBF and PEGMA74-FA25-JCBF1 in CHCl3. Reprinted with permission from ref. 32. Copyright 2018. Wiley VCH. |
The terpolymer was designed to have a PEGMA:
FA co-unit content of 75
:
25 mol%
:
mol%, ensuring solubility in water and organic solvents, while the JCBF co-unit content of approximately 1 mol% ensured UV light absorption–emission from isolated FMR labels.
The fluorescent probe JCBF was covalently anchored due to its poor solubility in water. The JCBF content was determined by UV absorption measurements of terpolymer solutions in chloroform. The JCBF chromophore exhibited no significant variation in its spectroscopic properties when incorporated in the amphiphilic polymer. The terpolymer consisted of 74, 25, and 1 mol% of PEGMA, FA, and JCBF, respectively, and was named PEGMA74-co-FA25-co-JCBF1.
The fluorescence emission intensity of the terpolymer is higher in water compared to organic solvents because of the preferential encapsulation of the hydrophobic JCBF co-units within the hydrophobic compartments of the terpolymer (Fig. 9a). This leads to a reduction in their degree of mobility, resulting in an increased intensity of fluorescence emission. Additionally, the hydrophilic PEGMA chains of the terpolymer maximize contact with water, further enhancing the fluorescence emission intensity (Fig. 9b). Its thermo-responsive behavior in water is demonstrated through DLS, UV-vis, and fluorescence spectroscopy measurements. This design and synthesis could be useful for advanced applications, such as controlled drug delivery systems.
In 2018 Mori and his co-workers used 9-(dicyanovinyl)julolidine (DCVJ) and its derivatized form, 9-(2-carboxy-2-cyanovinyl)julolidine (CCVJ), belonging to a group of TICT-type fluorophores that serve as representative examples.33 The authors here focused on the rotation of molecules in either a two-dimensional monolayer or a three-dimensional collapsed film at an air–water interface. By employing fluorescence spectroscopy, the researchers investigated the rotational behavior of specific molecules. They discovered that as viscosity increased, the fluorescence intensity also increased, indicating a hindrance in internal molecular rotations. Furthermore, the emissions from the monolayers remained suppressed until the monolayers collapsed. To measure the rotation of molecules in the monolayer or collapsed film, in situ fluorescence spectroscopy was employed. The researchers observed no excimeric emission even after monolayer compression indicating free intramolecular rotation.
When the molecules are placed in a less viscous solvent, they have the ability to rotate within themselves, resulting in a decrease in the intensity of fluorescence. On the other hand, when the molecules are in a more viscous solvent, their rotation is hindered, leading to an increase in fluorescence intensity (Fig. 10). This interesting phenomenon can be utilized to monitor the internal motion of the molecules. In a study focused on the rotation of molecules at the air–water interface, it was discovered that the collapse of the monolayers resulted in the suppression of emissions. Before the collapse of the monolayers, no fluorescence was observed for CCVJ-C12 or CCVJ-Chol. However, after the collapse of the monolayers, clear emission from the monomers was observed when CCVJ-C12 was dispersed in glycerol. This confirmed that the observation of monomer fluorescence was possible with the specific quantity of molecules used, as long as intramolecular rotation was inhibited. The transferred film was analyzed for its morphological and fluorescence properties. From the AFM images, no significant changes in morphology were observed before and after the collapse of the monolayers. The fluorescence properties of the LB films were also analyzed. Prior to the collapse, the LB film of the monolayer did not exhibit monomer fluorescence, indicating that the intramolecular rotation of molecules was not inhibited in the LB film. However, the collapsed film showed excimer emission at 600 nm, similar to the collapsed monolayer at the air–water interface.
![]() | ||
Fig. 10 (a) Fluorescence emission spectra of CCVJ-C12 (left) and (b) CCVJ-Chol (right) at surface pressure from 0 to over 50 mN m−1. Reprinted with permission from ref. 33. Copyright 2018. Royal Society of Chemistry. |
This study demonstrates that TICT-type lipophilized fluorescent rotors in monolayers at the air–water interface are capable of free intramolecular rotation, as evidenced by the absence of fluorescence emission indicative of rotation inhibition. However, when subjected to in-plane compression resulting in monolayer collapse, rotation was inhibited and excimer emission was observed. The proposed mechanism for monolayer collapse involves protrusion of the monolayer to the air side, where hydrophilic chromophores interact and inhibit internal molecular rotation. A list of julolidine-based FMRs used for understanding self-assembly and aggregation-induced emission properties is provided in Fig. 11.
![]() | ||
Fig. 11 Schematic representation and structures of the probes for self-assembly and aggregation induced emission. |
Chwastek and his co-workers in 2020 proposed a method using fluorescence correlation spectroscopy (FCS) to estimate the diffusivity of a molecular probe.35 FCS can provide a quantitative measure of probe diffusivity, which can be related to the viscosity of the medium. The dye DCVJ is located in the vicinity of the glycerol backbone of phospholipids rather than around the terminal methyl moiety of acyl chains. Its high sensitivity to the cholesterol content of the lipid membrane indicates its preferential localization in the proximity of membrane cholesterol. The stable localization of the dye close to the cholesterol pocket of the lipid membrane is supported by the lack of noticeable changes in the emission spectra of DCVJ for different membrane compositions and temperatures. Finally, the comparison between Mycoplasma mycoides membranes and artificial lipid mixtures showed that at temperatures equal to or above the growth conditions, the bacterial membranes have a very similar viscosity and temperature dependence to that of the liquid-disordered (Ld) state artificial lipid mixture. However, at temperatures below the growth conditions, the viscosity of the bacterial membranes approaches the values of the liquid-ordered (Lo) phase of the artificial lipid mixture, indicating a more viscous state. This suggests that the lipid membrane of Mycoplasma mycoides exists in the fluid (Ld) state at and above the growth temperature, and transforms into a more viscous (Lo) phase at temperatures about 10 degrees below the growth temperature.
PDT has emerged as a promising theranostic approach with notable advantages such as spatial–temporal controllability, non-invasiveness, and minimal drug resistance.36 The development of new photosensitizers (PSs) with unique properties has garnered significant attention. Extensive efforts have been dedicated to creating PSs with high efficiency in producing singlet oxygen (1O2), the ability to target specific organelles, and absorption in the red to near-infrared (NIR) range. Among the organelle-targeting PSs, those that target mitochondria can greatly enhance the photodynamic effect due to the pivotal role of mitochondria in cellular function and their association with cell apoptosis. Monitoring the dynamics of mitochondrial viscosity is crucial as it is closely linked to respiratory state and mitochondrial metabolism. Numerous methods have been established for this purpose.
Recently, two dual functional PSs were reported, capable of targeting mitochondria and exhibiting a ‘turn-on’ fluorescence response to changes in viscosity.36 It is noteworthy that CCVJ-Mito-2, one of the PSs, has absorption in the NIR region, making it more suitable for in vivo PDT applications (Fig. 12). These two PSs were successfully employed to detect viscosity changes in mitochondria and demonstrated phototoxicity to cancer cells even at extremely low concentrations. CCVJ-Mito-1 and CCVJ-Mito-2 were synthesized through a Knoevenagel condensation reaction. CCVJ-Mito-1 exhibited maximum absorption around 600 nm, while CCVJ-Mito-2 showed a longer absorption wavelength at approximately 680 nm in water due to an extended conjugation system. In glycerol, both PSs exhibited a bathochromic shift in absorption compared to water, which could be attributed to suppressed intramolecular rotation (Fig. 13a and b). Importantly, the fluorescence signal of CCVJ-Mito-1 and CCVJ-Mito-2 did not significantly enhance in the presence of other common biomolecules, indicating their good selectivity towards viscosity.
![]() | ||
Fig. 12 Structure design of dual functional PSs and synchronous mitochondrial viscosity dynamic imaging. Reprinted with permission from ref. 36. Copyright 2022. Royal Society of Chemistry. |
![]() | ||
Fig. 13 Fluorescence response of CCVJ-Mito-1 (A) & CCVJ-Mito-2 (B) towards viscosity variation by changing glycerol fraction (fg). Inset show the validation of Förster–Hoffmann equation. Reprinted with permission from ref. 36. Copyright 2022. Royal Society of Chemistry. |
The fluorescence of CCVJ-Mito-1 and CCVJ-Mito-2 remains largely unaffected by changes in pH, making them suitable for use in complex biological environments. This characteristic, combined with the fact that the fluorescence of these PSs overlaps with that of MitoTracker Green-FM in HeLa cells and other types of cancer cells, suggests that both CCVJ-Mito-1 and CCVJ-Mito-2 have the potential to target mitochondria. Additionally, these two dual functional PSs have been successfully developed to not only efficiently perform photodynamic therapy on cancer cells but also monitor changes in mitochondrial viscosity in real-time.
The authors have successfully created two PSs, CCVJ-Mito-1 and CCVJ-Mito-2, that have dual functionality. These PSs are capable of effectively carrying out PDT on cancer cells while simultaneously monitoring the viscosity dynamics of mitochondria. Our team is confident that these PSs will aid in our understanding of the changes that occur in the intracellular microenvironment during PDT and will guide future PDT processes. Of particular interest is PS CCVJ-Mito-2, which has NIR absorption and holds great potential for in vivo biological applications. We are currently conducting relevant studies on this PS.
Our research group has designed molecular rotors based on julolidine to investigate the viscosity of subcellular compartments. To achieve a far-red emission, we extended the conjugation between the julolidine donor and dinitrile acceptor groups. The acceptor group was attached with a tolyl group or indoline group, as introduction of a bulkier indoline group enhances the viscosity sensitivity of the rotor. Further, organelle targeting moieties are attached to specifically localize the rotor to the particular target in the cells. Jind-mor has been conjugated with a morpholine group to guide the molecule to the lysosomal compartment of the cells.37 It was utilized to monitor the lysosomal stress in live cells and osmotic stress in C. elegans. In another variation, we modified the rotor by introducing a trimethyl ammonium cationic group, guiding the resulting JMT rotor to the mitochondria of cells.38JMT was then utilized to assess mitochondrial stress, leveraging the fact that under stress conditions, the viscosity of mitochondria tends to increase. Researchers have documented a distinct form of cell death called ferroptosis, which is dependent on iron and differs in appearance and biochemical characteristics from apoptosis, necrosis, and autophagy. This unique process plays a crucial role in the development of various diseases and has emerged as a significant area of research for improving the treatment and prognosis of related conditions. During ferroptosis, the depletion of intracellular glutathione (GSH) leads to a decrease in the activity of glutathione peroxidase (GPX4). As a result, lipid peroxides cannot be metabolized through the GPX4-catalyzed reduction reaction, while Fe2+ continuously oxidizes lipids in a manner similar to the Fenton reaction, leading to the generation of a substantial amount of reactive oxygen species (ROS) that promote ferroptosis. In order to regulate ER homeostasis, ER stress triggers ER-associated degradation. ER-phagy, a newly identified type of autophagy, eliminates damaged ER caused by excessive ER stress and safeguards cells from additional harm. When ER stress occurs, misfolded and unfolded proteins accumulate in the ER, leading to an elevation in ER viscosity.39 A list of julolidine-based far-red emissive FMRs used for understanding sub-cellular organelle viscosity under stress conditions is provided in Fig. 14.
Fluorescence bioimaging is an effective technique for tracking subcellular viscosity, offering numerous benefits including noninvasiveness, speed, real-time monitoring, and spatiotemporal imaging. In this study, the researchers have successfully designed and synthesized a molecular rotor that is sensitive to viscosity, enabling the monitoring of endoplasmic reticulum (ER) changes during various modes of biological cell death. To specifically target the ER, derivatives of sulphonylurea were employed, as the ER lumen contains sulphonamide receptors. The synthesized probe, named JER, was modified with p-toluene sulphonamide to serve as the recognition component for the ER.39
The absorption peak was observed at a wavelength of 540 nm, while the emission peak occurred at 644 nm. Additionally, the excitation peak was also observed at 540 nm when using DMSO as the solvent. The absorption and excitation spectra showed a good overlap, indicating the presence of a single emitting chromophore with high optical purity.
The emission behavior of JER in different solvents revealed that it exhibited significant fluorescence intensity in highly viscous solvents, while a weak fluorescence was observed in low viscosity solvents. This can be attributed to the presence of a conjugated double bond between the donor and acceptor, which regulates the emission properties of the probe in solutions with varying viscosity. Furthermore, a remarkable 400-fold increase in fluorescence intensity was observed with increasing glycerol percentage in water. The fluorescence intensity at 645 nm was well-fitted by the Förster–Hoffmann equation, logI = x
log
Z + log
C. A strong linear relationship (R2 = 0.98) was found within the viscosity range of 2 to 905 cP. Importantly, this linear relationship over a wide viscosity range suggests that JER has the potential to be used as a fluorophore for measuring cellular microviscosity. Additionally, fluorescence measurements were also conducted using varying percentages of methanol in glycerol with similar polarity. A list of julolidine-based FMRs used for understanding sub-cellular viscosity is provided in Fig. 15.
The emission properties of JER were also analyzed by the author in relation to pH for potential use in a biological setting. By examining the fluorescence properties of JER in various pH solutions with an intracellular viscosity of approximately 156 cP, we were able to determine its pH tolerance. The probe also demonstrated remarkable photostability when exposed to continuous irradiation (90 lx) from a 450 W xenon lamp for up to 60 minutes. These findings establish JER as a suitable tool for investigating viscosity in a biological environment.
In 2016, Joly and co-workers investigated the solid-state polymerization (SSP) process of poly(butylene succinate) (PBS) by utilizing the emission properties of a 9-(2-carboxy-2-cyanovinyl)julolidine (CCVJ) molecular rotor.40 The emission of CCVJ was dependent on both the molecular weight of the polymer and the local polarity of the polymer. The emission maximum of CCVJ shows a strong blue shift with a decrease when the Mw increased. The observation was attributed to the local polarity change of the PBS medium around the CCVJ probe. The shorter polymeric chains exhibited a higher acidic index (AI) value and consequently a higher medium polarity. As demonstrated in Fig. 16, the decline in the fluorescent intensity and associated blue shift are because of the increase in PBS molecular weight. According to these results, CCVJ can be employed to monitor the SSP process kinetics.
![]() | ||
Fig. 16 Emission spectra of CCVJ embedded in PBS of different molecular weights (Mw). Reprinted with permission from ref. 40. Copyright 2016. Elsevier. |
Andrea Pucci and his colleagues have used AIEgens as fluorescent probes for monitoring the polymerization of 4,4′-methylenediphenyl diisocyanate (MDI) and polyethylene glycol to form polyurethane in a dimethylacetamide solution.41 The polymerization kinetics was effectively monitored from the viscosity variation associated with the degree of polymerization. The variation of viscosity due to the polymerization process was monitored using the relative fluorescence variation of the DCVJ-based fluorescent molecular rotor using an optical fiber based excitation connected to a spectrofluorometer. The fluorescence change in the DCVJ rotor probe matches well with the viscosity variation due to the polymerization process as shown in Fig. 17.
In 2020, Yao et al. investigated the fluorescence emission of a CCVJ-based molecular rotor to differentiate glucan polymers with different branch structures. The authors have prepared amylopectin, phytoglycogen, and their β-limit dextrins as glucan models, and incorporated CCVJ as a hydrophilic molecular rotor.42 The viscosities of dilute glucan dispersions were determined and the fluorescence response of CCVJ in these dispersions was measured (Fig. 18). The emission CCVJ showed a linear correlation with glucan content. The plot of fluorescence emission response of CCVJ against branch concentration (Cb) shows linear dependence for diluted glucan dispersions. Hence, the FMR can be used as an analytical tool for differentiating different branch structures of biopolymers.
![]() | ||
Fig. 18 Corrected fluorescence emission response of CCVJ in diluted glucan dispersions as a function of branch concentration (Cb). Reprinted with permission from ref. 42. Copyright 2020. Elsevier. |
Andrea Pucci and co-workers have reported polystyrene copolymers containing julolidine fluorescent molecular rotors (JCAEM) to develop vapochromic films for detecting volatile organic compounds (VOCs).43 Poly(styrene-co-hydroxyethylmethacrylate) copolymers functionalized with JCAEM (P(STY-co-JCAEM)), exhibited viscosity-dependent emission properties when exposed to saturated atmospheres of VOCs which interacted well with the emission reporter. The authors observed a pronounced decrease in the emission intensity (Fig. 19) due to the solvent-induced changes in the local viscosity of the medium. As expected, the response appeared faster and more pronounced (Fig. 19) for copolymers with the lowest JCAEM content. A significant vapochromism was observed when exposed to Et2O and CH2Cl2 vapours due to strong deactivation pathways of the JCAEM units in the presence of VOCs. This phenomenon was attributed to the role of the covalent approach for JCAEM moiety distribution in the polymer matrix.
![]() | ||
Fig. 19 (a) Quenching of fluorescence emission of the P(STY-co-JCAEM) film (0.06 mol% JCAEM) as a function of exposure to chloroform vapors; (b) variation in the fluorescence maximum intensity with exposure time to chloroform vapors for all P(STY-co-JCAEM) (mol% of JCAEM) films; the inset shows the rate constant of the attenuation of emission intensity. Reprinted with permission from ref. 43. Copyright 2017. Royal Society of Chemistry. |
This review provides a comprehensive overview of current research in this field and discusses the potential for future advancements. Notably, the exploration of viscosity changes throughout different phases of the cell cycle and their implications in developmental biology remains an unexplored avenue using julolidine-based molecular rotors. Additionally, these rotors can be employed to investigate remote and inaccessible local environmental parameters, including viscosity and pressure. Further advancements in modifying julolidine-based molecular rotors to emit in the far-red or near-infrared spectrum, coupled with good solubility, could unlock numerous possibilities for practical applications in real-world scenarios.
Footnote |
† Contributed equally to this work. |
This journal is © The Royal Society of Chemistry 2024 |