João C.
Silva‡
*abc,
Pedro
Marcelino
abcd,
João
Meneses
d,
Frederico
Barbosa
abc,
Carla S.
Moura
de,
Ana C.
Marques
fg,
Joaquim M. S.
Cabral
abc,
Paula
Pascoal-Faria
dhj,
Nuno
Alves
dij,
Jorge
Morgado
ck,
Frederico Castelo
Ferreira
*abc and
Fábio F. F.
Garrudo‡
*abck
aiBB – Institute for Bioengineering and Biosciences, Instituto Superior Técnico, Universidade de Lisboa, Av. Rovisco Pais, Lisboa 1049-001, Portugal. E-mail: joao.f.da.silva@tecnico.ulisboa.pt; frederico.ferreira@tecnico.ulisboa.pt; fabio.garrudo@tecnico.ulisboa.pt; fabio.garrudo@edu.ulisboa.pt
bAssociate Laboratory i4HB – Institute for Health and Bioeconomy, Avenida. Rovisco Pais, Lisboa 1049-001, Portugal
cDepartment of Bioengineering, Instituto Superior Técnico, Universidade de Lisboa, Avenida Rovisco Pais, Lisboa 1049-001, Portugal
dCDRSP – Centre for Rapid and Sustainable Product Development, Polytechnic Institute of Leiria, Rua de Portugal-Zona Industrial, Marinha Grande 2430-028, Portugal
eResearch Centre for Natural Resources Environment and Society (CERNAS), Polytechnic Institute of Coimbra, Bencanta, 3045-601 Coimbra, Portugal
fCERENA, DEQ, Instituto Superior Técnico, Universidade de Lisboa, Avenida Rovisco Pais, Lisboa 1049-001, Portugal
gDepartment of Chemical Engineering, Instituto Superior Técnico, Universidade de Lisboa, Avenida Rovisco Pais, Lisboa 1049-001, Portugal
hDepartment of Mathematics, School of Technology and Management, Polytechnic of Leiria, Morro do Lena—Alto do Vieiro, Apartado 4163, Leiria 2411-901, Portugal
iDepartment of Mechanical Engineering, School of Technology and Management, Polytechnic of Leiria, Morro do Lena—Alto do Vieiro, Apartado 4163, Leiria 2411-901, Portugal
jAssociate Laboratory Arise, Porto, Portugal
kInstituto de Telecomunicações, Instituto Superior Técnico, Universidade de Lisboa, Avenida Rovisco Pais, Lisboa 1049-001, Portugal
First published on 6th February 2024
In this work, we propose a simple, reliable, and versatile strategy to create 3D electroconductive scaffolds suitable for bone tissue engineering (TE) applications with electrical stimulation (ES). The proposed scaffolds are made of 3D-extruded poly(ε-caprolactone) (PCL), subjected to alkaline treatment, and of poly(3,4-ethylenedioxythiophene):poly(styrene sulfonate) (PEDOT:PSS), anchored to PCL with one of two different crosslinkers: (3-glycidyloxypropyl)trimethoxysilane (GOPS) and divinyl sulfone (DVS). Both cross-linkers allowed the formation of a homogenous and continuous coating of PEDOT:PSS to PCL. We show that these PEDOT:PSS coatings are electroconductive (11.3–20.1 S cm−1), stable (up to 21 days in saline solution), and allow the immobilization of gelatin (Gel) to further improve bioactivity. In vitro mineralization of the corresponding 3D conductive scaffolds was greatly enhanced (GOPS(NaOH)-Gel – 3.1 fold, DVS(NaOH)-Gel – 2.0 fold) and cell colonization and proliferation were the highest for the DVS(NaOH)-Gel scaffold. In silico modelling of ES application in DVS(NaOH)-Gel scaffolds indicates that the electrical field distribution is homogeneous, which reduces the probability of formation of faradaic products. Osteogenic differentiation of human bone marrow derived mesenchymal stem/stromal cells (hBM-MSCs) was performed under ES. Importantly, our results clearly demonstrated a synergistic effect of scaffold electroconductivity and ES on the enhancement of MSC osteogenic differentiation, particularly on cell-secreted calcium deposition and the upregulation of osteogenic gene markers such as COL I, OC and CACNA1C. These scaffolds hold promise for future clinical applications, including manufacturing of personalized bone TE grafts for transplantation with enhanced maturation/functionality or bioelectronic devices.
Electrical stimulation (ES) is a powerful tool with potential therapeutic application in bone diseases.6 Fonseca Junior and colleagues7 reported the benefit of combining ES (10 μA) with commercial bone grafts to reduce inflammation and improve vascularization and mineralization in transplanted rats. Leppik and colleagues8 observed, in rats, an enhancement on new bone formation, increased vascularization and improvement of the mechanical properties when ES (0.1–0.2 μA) was used concomitantly with transplanted mesenchymal stem/stromal cells (MSCs) cultured on β-tricalcium phosphate granules. The authors also showed that ES (1 V cm−1, 1 h day−1, and 21 days) could greatly enhance the osteogenic differentiation of rat MSCs. In a follow-up study, Oliveira and colleagues9 observed that ES promoted tissue healing over scarring in amputated rats. This was attributed to ES induced anisotropy of collagen fibers, and promotion of short-term inflammation and long-term cell proliferation. Additionally, other in vitro studies support these observations.10–13 Overall, the use of ES holds high promise for innovative tissue engineering (TE) strategies targeting the repair of osteoporosis-related non-union fractures.
Additive manufacturing technologies enable the fabrication of electroactive constructs with complex architectures both for TE applications and to be used as soft electronics devices for man–machine interfaces.14,15 3D-melt extrusion or fused deposition modeling (FDM) is an additive manufacturing technique that uses thermoplastics, such as poly(ε-caprolactone) (PCL), to create scaffolds that structurally and mechanically mimic the bone tissue.16–18 PCL is an FDA-approved polymer for biomedical products and a first choice for scaffold development for bone TE applications.19 This is due to its biocompatibility, advantageous mechanical properties to support bone tissue and tunable degradation profile.19,20 Our group has previously developed 3D PCL scaffolds with high porosity and interconnectivity, and capable of supporting MSC growth and chondrogenic differentiation.21,22 These can also be used for bone repair applications due to their controlled architecture, high porosity/pore size and ease of functionalization. We and other groups had also showed the successful inclusion of bioactive components such as hydroxyapatite,23 β-tricalcium phosphate,24 fibrin25 and deposited MSC-derived ECMs26 to greatly increase their osteogenic potential. However, PCL-derived scaffolds are not suitable for effectively harnessing ES to cultured cells and thus require further modifications.
Electroconductive polymers (ECPs) can be used to fabricate electroactive scaffolds for TE strategies. ECPs present important advantages for overall TE applications, including effective ES of stem cells, design of impedance sensors to monitor cell health and ES-controlled drug release.27–29 ECPs cannot be easily printed/extruded in 3D structures due to the absence of a melting point compatible with the manufacturing process. Thus, they require advanced processing and specialized additive manufacturing techniques15,30 and/or the development of polymer blends with reduced electroconductivity.31–33 Poly(3,4-ethylenedioxythiophene):poly(styrene sulfonate) (PEDOT:PSS) is an ECP, suitable for the design of TE scaffolds due to its high stability and biocompatibility.34–36 For example, Guex and colleagues37 reported the development of an electroconductive (6.1 × 10−6 S cm−1) ice-templated PEDOT:PSS scaffold capable of supporting MC3T3-E1 cells' osteogenic differentiation and the deposition of the mineralized extracellular matrix (ECM). PEDOT:PSS can also be processed into versatile electroconductive composites with collagen38 and nanohydroxyapatite/chitosan39 for bone TE applications. Nevertheless, its inclusion in composites suitable for 3D-extrusion remains limited.
In our previous work, we studied the performance of PEDOT:PSS films, cross-linked using (3-glycidyloxypropyl)trimethoxysilane (GOPS) and divinyl sulfone (DVS), for neural applications.40 The chemistry involved in the cross-linking of PEDOT:PSS with GOPS/DVS involves the formation of ether/ester bonds with PSS and the respective support substrate (e.g. glass). We hypothesize that cross-linked PEDOT:PSS can be used to homogeneously coat 3D-extruded scaffolds made of polyesters (e.g. PCL), widely used in biomedical applications.19 The presence of free hydroxyl/carbonyl groups, maximized through alkaline treatment, ensures effective immobilization of PEDOT:PSS at their surface and the formation of continuous films. This potential strategy is easy, straightforward and can be used with scaffolds with diverse architecture without the need for specialized equipment.
The goal of this work is to create an electroconductive 3D scaffold suitable for bone tissue engineering and electrical stimulation using a simple, reliable, and versatile method, based on the combination of 2D and 3D materials.41 The envisaged scaffold is composed of a 3D-extruded PCL skeleton and a cross-linked PEDOT:PSS coating. We harnessed the chemistry of both materials, and later in combination with gelatin, to create a stable yet bioactive and mechanically robust scaffold. We used in silico tools to further demonstrate the advantages of a PEDOT:SS coating on electrical field distribution in a porous scaffold. Finally, we used the best PCL-PEDOT:PSS scaffold combination to study its ability to enhance osteogenic differentiation of MSCs under electrical stimulation. The design and production strategy employed are highly versatile and easy to implement on similar scaffolds with different architectures. We believe that this strategy can be used in future clinical applications, including transplantation of personalized bone TE constructs with enhanced maturation/functionality or devices for bioelectronic applications.
The designed PCL film was shaped as a 20 mm × 10 mm × 0.5 mm cuboid. To fill any gaps and ensure a smooth first layer, the first layer was modified to be printed with a 0.15 mm extrusion width and using a 1.2 extrusion multiplier.
For the PCL scaffold design, an orthogonal pattern with aligned fibers was chosen (0–90° rotations between successive layers). The pore size of the scaffold and fiber diameter were both specified to have a dimension of 300 μm. The overall scaffold size was 10.5 mm × 10.5 mm × 3 mm. Since each scaffold layer had a height of 0.30 mm with the defined printing layer height of 0.15 mm, two printing passages were necessary to print each scaffold layer.
PCL and PCL(NaOH) scaffolds were coated with PEDOT:PSS to become electroconductive. For this, four different PEDOT:PSS solutions were prepared for the dip-coating of the scaffolds:
Solution 1: PEDOT:PSS + EG (1:4, by volume) + DBSA (0.5 μL mL−1) + GOPS (10 μL mL−1), followed by overnight agitation.
Solution 2: content of solution 1 + gelatin (2%, by weight with respect to the PEDOT:PSS volume used), followed by overnight agitation and 50 °C.
Solution 3: PEDOT:PSS + EG (1:4, by volume) + DBSA (0.5 μL mL−1) + DVS (30 μL mL−1), followed by overnight agitation.
Solution 4: content of solution 3 + gelatin (2%, by weight with respect to the PEDOT:PSS volume used), followed by overnight agitation and 50 °C.
The constructs were submerged in the solutions for 24 hours under constant agitation. These were then collected and annealed at ≈55 °C overnight The chemical formulas of the main components of our scaffolds are depicted in Fig. 1 The summary of the procedure is depicted in Fig. 2. A list of all the samples produced is presented in Table 1.
Fig. 2 Summary of the protocols used to coat PCL films/scaffolds and respective PEDOT:PSS solutions used (Image created using BioRender.com, agreement number: OY26H1R3WS). |
Sample code | NaOH treatment | PEDOT:PSS solution used for coating | H2SO4 treatment | Annealing at 50 °C | ||||
---|---|---|---|---|---|---|---|---|
EG (V V−1) | DBSA (0.5 μL mL−1) | GOPS (μL mL−1) | DVS (μL mL−1) | Gelatin (% m V−1) | ||||
PCL | No | X | X | X | X | X | X | No |
PCL(NaOH) | Yes | X | X | X | X | X | X | No |
GOPS | No | 1:4 | 0.5 | 10 | X | X | X | Yes |
GOPS(NaOH) | Yes | 1:4 | 0.5 | 10 | X | X | X | Yes |
GOPS(NaOH)-Gel | Yes | 1:4 | 0.5 | 10 | X | 2 | X | Yes |
DVS | No | 1:4 | 0.5 | X | 30 | X | X | Yes |
DVS(NaOH) | Yes | 1:4 | 0.5 | X | 30 | X | X | Yes |
DVS(NaOH)-Gel | Yes | 1:4 | 0.5 | X | 30 | 2 | X | Yes |
PCL(50 °C) | No | X | X | X | X | X | No | Yes |
PCL(H2SO4) (50 °C) | No | X | X | X | X | X | Yes | Yes |
PCL(NaOH) (50 °C) | Yes | X | X | X | X | X | No | Yes |
PCL(NaOH) (H2SO4, 50 °C) | Yes | X | X | X | X | X | Yes | Yes |
Image reconstruction was done using NRecon software, version 1.7.4.6 (Bruker, Billerica, MA, USA). Realistic visualizations of the scaffolds were achieved using CTVox software (version 3.3.1., Bruker, Billerica, MA, USA). Porosity, interconnectivity, and the surface area to volume ratio were directly obtained from the software.
Reconstruction/shape fidelity analysis was performed using CTAn software (version 1.20.0, Bruker, Billerica, MA, USA). The pore size and fiber diameter were obtained from two perpendicular directions for the printed scaffolds: one along the printed layers, and another across the printed layers. Three measurements were made in each direction to obtain the average dimensions.
In model 1, the electrical properties of each fiber were predicted using a single 2D filament model. This procedure was aimed at understanding the impact on the numerical predictions when considering (1) a homogeneous thin electroconductive coating on an inert filament core or (2) the whole electroconductive filament.
In model 2, a 3D complete model of one culture well with an orthogonal scaffold (in permanent contact with both electrodes) was used to compare the predicted electrical field among the different coating material options. This is possible since by construction the electric current that passes through one well is equal to that through the remaining wells placed in series. The electrical current (ec) physics interface was selected, considering a stationary study and applying a floating potential boundary condition at one electrode side surface. The remaining electrode has a ground reference boundary condition. The required electric current and potential measurements were performed with a multimeter (ISO-TECH IDM 73). 3D physics-controlled meshes were also generated in COMSOL. Whole model meshes were constructed using tetrahedra, triangles, edges and vertex with a total of 2.3 million elements. A finite element mesh study was also performed to guarantee that the results, (i.e., minimum element quality: 0.03; average element quality: 0.66; element volume ratio: 9.14 × 10−6), are independent of the mesh size. The properties of the materials used in FEA are described in Table S1 (ESI†). The COMSOL linear stationary iterative solver was used to compute the solution for each model.
The hBM-MSCs were seeded on the scaffolds at a density of 120000 cells per scaffold. The cell-seeded scaffolds were incubated at 37 °C and 5% CO2 in a humidified atmosphere for 2 h without cell culture medium to promote initial cell adhesion. The cultures were maintained for 7 days under standard expansion medium (DMEM + 10% FBS (MSC qualified) + 1% Anti–Anti) in an incubator at 37 °C and 5% CO2 and the medium was replaced every 2–3 days.
The proliferation of hBM-MSCs on the different scaffold conditions was monitored on days 1, 4 and 7 using the AlamarBlue™ assay following the manufacturer's guidelines. Briefly, a 10% (v/v) AlamarBlue™ solution diluted in cell culture medium was added to the scaffolds and incubated at 37 °C and 5% CO2 in a humidified atmosphere for 3 h. The fluorescence intensity values were measured in a microplate reader (Infinite 200 Pro; Tecan, Switzerland) at an excitation/emission wavelength of 560/590 nm. For each experimental group, the fluorescence intensity was analyzed for four independent scaffolds (n = 4) and acellular scaffolds were used as blank controls.
In order to evaluate the morphology of hBM-MSCs on the different scaffolds, samples were stained with DAPI (1.5 μg mL−1 in PBS) and Phalloidin-TRITC (2 μg mL−1 in PBS). The cells were first washed with PBS and fixed with a 4% PFA solution for 10 min. Afterwards, cells were incubated with blocking solution (10% goat serum and 0.2% Triton-X-100 in PBS) for 30 min. Samples were then incubated with Phalloidin-TRITC for 45 min in the dark. After this, the samples were washed twice with PBS and counterstained with DAPI for 5 min. Finally, the samples were washed with PBS and the fluorescence staining was imaged using a confocal fluorescence microscope (Zeiss LSM 710, Germany).
Xylenol orange staining was used to assess the presence of mineral deposits within the samples after 21 days of osteogenic differentiation with and without electrical stimulation. Briefly, previously fixed cell-seeded 3D scaffolds were incubated with xylenol orange red solution (20 mM) for 1 h at room temperature. The scaffolds were washed with PBS, counterstained with DAPI (1.5 μg mL−1 in PBS) for 5 min and washed once again with PBS. The fluorescence staining was imaged using a confocal fluorescence microscope (Zeiss LSM 710, Germany).
Gene | Fwd primer sequence | Rev primer sequence |
---|---|---|
GAPDH | 5′-GGTCACCAGGGCTGCTTTTA-3′ | 5′-CCTGGAAGATGGTGATGGGA -3′ |
RUNX2 | 5′-AGATGATGACACTGCCACCTCTG-3′ | 5′-GGGATGAAATGCTTGGGAACT-3′ |
OSX | 5′-CTGGACATGACACACCCCTAT-3′ | 5′-GCTGGATTAAGGGGAGCAAAG-3′ |
COL I | 5′-CATCTCCCCTTCGTTTTTGA-3′ | 5′-CCAAATCCGATGTTTCTGCT-3′ |
OC | 5′-TGTGAGCTCAATCCGGCATGT-3′ | 5′-CCGATAGGCCTCCTGAAGC-3′ |
OPN | 5′-CAGGTCTGCGAAACTTCTTAG-3′ | 5′-CTCCATTGACTCGAACGACTC-3′ |
CACNA1C | 5′-GTACAAAGACGGGGAGGTTGAC-3′ | 5′-GTAGTTGTAGATGGGGCCCTTG-3′ |
Films | PCL | PCL(NaOH) | GOPS | GOPS(NaOH) | GOPS(NaOH)-gel. | DVS | DVS(NaOH) | DVS(NaOH)-gel. |
---|---|---|---|---|---|---|---|---|
Electroconductivity (S cm−1) | — | — | 7.2 ± 3.2 | 3.0 ± 2.7 | 20.1 ± 5.7 | 8.6 ± 4.2 | 6.1 ± 4.0 | 11.3 ± 3.2 |
Contact angle (°) | 79.9 ± 2.0 | 59.0 ± 2.3 (*) | 57.2 ± 8.0 (*) | 55.8 ± 4.9 (*) | 18.3 ± 0.9 (*)(a) | 49.0 ± 4.1 (*) | 46.4 ± 2.1 (*) | 7.9 ± 0.7 (*)(a) |
Scaffolds | PCL | PCL(NaOH) | GOPS | GOPS(NaOH) | GOPS(NaOH)-gel | DVS | DVS(NaOH) | DVS(NaOH)-gel |
---|---|---|---|---|---|---|---|---|
Young's modulus (MPa) | 8.8 ± 0.2 | 8.6 ± 0.3 | 8.8 ± 0.5 | 8.4 ± 0.5 | 10.2 ± 0.1(*)(+) | 8.8 ± 0.2 | 9.1 ± 0.1 | 10.6 ± 0.0(*)(+) |
Mineralization at day 21 (ng mg−1) | 0.41 ± 0.36 | 0.45 ± 0.24 | — | 2.66 ± 0.32 (*)(+) | 3.08 ± 0.21(*)(+) | — | 1.29 ± 0.57 | 1.97 ± 0.63 |
Adhesion (%) | 10.1 ± 1.4 | 12.3 ± 1.3 | — | 21.0 ± 5.5 | 14.2 ± 2.2 | — | 9.8 ± 2.3 | 21.7 ± 5.9 |
When solution 3 (PEDOT:PSS + DVS) was used for coating, both PCL and PCL(NaOH) samples, the contact angle decreased to 49° (DVS) and 46° (DVS(NaOH)), respectively. When gelatin was added to the coating of PCL-NaOH scaffolds (solution 4), the contact angle greatly decreased to 7.9° (DVS(NaOH)-Gel). Such a decrease was statistically significant for the sample DVS(NaOH).
The FTIR spectra for all samples are depicted in Fig. 3(B) (and also Fig. S1 (raw materials), ESI†). The spectra of PCL (spectrum a) and PCL(NaOH) (spectrum b) evidence the characteristic peaks at 2938/2861 cm−1, for asymmetric/symmetric CH2 bands, 1704 cm−1, for carbonyl groups, and 800–1500 cm−1, for the characteristic fingerprint region.54,55 The same peaks are visible for samples GOPS (spectrum c), GOPS(NaOH) (spectrum d), DVS (spectrum f) and DVS(NaOH) (spectrum g), along with small peaks at 1538 cm−1, for aromatic rings of PEDOT:PSS.56 The peak centered at 3480 cm−1, for free OH/NH groups is also visible but it is more intense for samples GOPS(NaOH)-Gel (spectrum e) and DVS(NaOH)-Gel (spectrum h). The spectrum of DVS(NaOH)-Gel (spectrum h in Fig. 3(B)) and to a lesser extent the spectrum of GOPS(NaOH)-Gel show the PCL characteristic peaks in the 800–1500 cm−1 spectral region, but their relative intensity is much lower, suggesting the presence of a thicker coating layer. Finally, the addition of gelatin to the PEDOT:PSS coating (spectra e and h) is associated with a change in the fingerprint region. This is more evident for sample DVS(NaOH)-Gel, whose respective peaks change in intensity and shape when compared with those of DVS(NaOH)-Gel. Such a change is similar to that observed by Sridharan and colleagues57 for coaxial PCL/Gelatin fibers and indicates the formation of a 2 layer composite consisting of PCL and a gelatin-coating.
DVS-based samples had the most hydrophilic coatings. This is in line with our previous observations for PEDOT:PSS films spin-coated on glass substrates.40 Samples whose PEDOT:PSS coating contained gelatin presented the lowest contact angle values of our study. In a different work, Ghasemi-Mabarakeh and colleagues58 observed that increasing the gelatin content of PCL-gelatin electrospun fibers leads to decreased contact angles. In our work, gelatin is present within the PEDOT:PSS layer. As such, these results, together with the FTIR spectra, indicate a successful incorporation of gelatin in the coating of our samples, which can potentially improve their bioactivity and promote the adhesion and growth of MSCs.59,60
Electroconductivity slightly increased for samples GOPS(NaOH)-Gel (20.1 S cm−1) and DVS(NaOH)-Gel (11.3 S cm−1), suggesting a positive effect of gelatin incorporation on electroconductivity. Such a phenomenon was not expected, as gelatin is an insulator. According to Huang and colleagues,62 low-molecular weight poly(ethylene oxide) has pseudo-doping properties and is capable of cross-linking PSS through its ether groups in an acidic environment. We speculate that a similar phenomenon could have happened between gelatin and PEDOT:PSS, which can also explain the electrical stability of previously reported gelatin-PEDOT:PSS scaffolds.63 To better clarify this phenomenon, we studied the corresponding spin-coated PEDOT:PSS films.
The main results for the obtained spin-coated PEDOT:PSS films are summarized in Fig. S3 (ESI†). Sample fDVS is the most electroconductive (1071 S cm−1) among the tested samples (Fig. S3(A), ESI†). It is statistically different from samples fDVS-Gel (290 S cm−1), fGOPS (240 S cm−1) and fGOPS-Gel (67 S cm−1). Such a trend was not observed for the PCL-PEDOT:PSS films. A closer analysis of the thickness of the spin-coated films (Fig. S3(B), ESI†) reveals dramatic differences. Samples fGOPS-Gel (46305 Å) and fDVS-Gel (14917 Å) showed higher thicknesses when compared with samples fGOPS (1333 Å) and fDVS (869 Å). These results suggest that the amount of immobilized material is higher for samples fGOPS-Gel and fDVS-Gel. Finally, we used the UV/Vis (Fig. S3(C), ESI†) and NIR (Fig. S3(D), ESI†) spectra of the obtained spin-coated PEDOT:PSS samples to evaluate how gelatin interferes with PEDOT:PSS. The addition of gelatin does not significantly affect the characteristic peak at 223 nm, but instead induces the formation of a smaller peak at 260 nm. Addition of gelatin negatively interferes with the conduction band, especially in sample fGOPS-Gel (1100–2300 nm) when compared to fGOPS. This effect is less pronounced in sample fDVS-Gel (1400–2300 nm), where the conduction band is slightly less intense than in fDVS. As such, we conclude that the addition of Gel to PEDOT:PSS films negatively interferes structurally with PEDOT:PSS, which affects its electroconductivity, but the use of DVS as the cross-linker avoids this.
The stability of the different PEDOT:PSS coatings was evaluated in vitro and by mimicking the physiological conditions of pH and osmolarity. The results obtained are shown in Fig. 3(C1) (electroconductivity changes for 21 days), Fig. 3(C2) (FTIR of samples at day 21), and Fig. S2 (ESI†) (FTIR of samples at days 1, 7 and 14). Electroconductivity of the coating was stable for all samples through the whole duration of the assay, with no significant statistical differences found among the samples from different timepoints.
FTIR shows minimal differences regarding the chemistry of all samples. The exception was sample DVS(NaOH)-Gel, which displays the most complex spectra of all samples. Its FTIR spectra at day 1 are completely different from those recorded for the dry film (Fig. 3(B)), in particular in the region 2000–800 cm−1. Starting at day 1, and for the following 7 and 14 days (Fig. S2, spectra f, ESI†), a broad peak region appears between 1200 cm−1 and 1600 cm−1, which matches the characteristic fingerprint region of gelatin containing amide peaks. A long band between 2000 cm−1 and 3600 cm−1 is visible, suggesting the co-existence of free amine/hydroxyl and ketone groups at the superficial region of the sample.64 While these can arise from the EG additive, as described by Mantione and colleagues,51 other potential sources are the gelatin or cross-linked PEDOT:PSS.40,65 At day 21 (Fig. 3(C2), spectrum h′) the long band at 2000–3600 cm−1 becomes less intense, and the fingerprint peaks of gelatin (800–1500 cm−1) are still visible, and the fingerprint region of PCL (800–1500 cm−1) is not observed, suggesting a potential swelling of the PEDOT:PSS coating.
The characteristic gelatin peaks at 1200–1650 cm−1 (Fig. S1, spectrum c, ESI†) are visible on the FTIR spectra of both samples GOPS(NaOH)-Gel and DVS(NaOH)-Gel at both days 0 and 21. These peaks are associated with amide groups,66 which present reactive spots for GOPS/DVS nucleophilic attack and consequent amide-to-ester conversion during cross-linking.
The spectra of both samples GOPS(NaOH)-Gel and DVS(NaOH)-Gel change after 21 days of incubation with PBS. For sample GOPS(NaOH)-Gel, the fingerprint regions at days 21 (Fig. 3(C2), spectra e′, 800–1.400 cm−1) 14, 7 and 1 (Fig. S2, spectra c, ESI†) resemble that of GOPS(NaOH) at day 0 (Fig. 3(B), spectra e). Since no changes in electroconductivity were found for this same sample, we hypothesize that these do not compromise the PEDOT:PSS coating per se. For sample DVS(NaOH)-Gel, the fingerprint region changes and new peaks at 1471 cm−1, 1271 cm−1 and 995 cm−1 appear. These peaks partly overlap those of gelatin raw material (Fig. S1, spectrum c, ESI†). Similar changes are observed for the other timepoints of the stability assay (Fig. S2, ESI†). While the DVS(NaOH)-Gel system is chemically complex, making the changes in the fingerprint region difficult to interpret, we can speculate that these changes can be attributed to gelatin chain rearrangement that occurs after water retention. In this case, the obtained coating is more stable and more efficient at retaining chemically bonded gelatin, which prevents its lixiviation and allows the coating to retain its bioactivity. As such, we hypothesize that sample DVS(NaOH)-Gel will have a higher bioactivity when compared with sample GOPS(NaOH)-Gel.
The morphology of the obtained PCL and PCL-PEDOT:PSS coated scaffolds (SEM and MicroCT) is shown in Fig. 4. SEM images reveal an overall smooth surface in all the obtained samples. Small cavities can be seen in the higher magnification images of samples PCL, GOPS(NaOH), GOPS(NaOH)-Gel, DVS(NaOH) and DVS(NaOH)-Gel, which originate from PCL.24 They can provide extra surface area for cell adhesion. Other imperfections are seen, such as powder deposits (GOPS, GOPS(NaOH)) and a flat first layer (DVS, DVS(NaOH) and DVS(NaOH)-Gel), but they are attributed to the sample preparation process for SEM analysis.
MicroCT images also evidence homogeneous scaffolds with limited imperfections, independently of the chemical treatments and coating solutions used. The different structural properties of the scaffolds are summarized in Table 4. All scaffolds have a pore interconnectivity of around 100%, which is highly favorable for the diffusion of nutrients, oxygen and soluble factors, as well as cell migration and proliferation. Other structural parameters are relatively constant and do not vary for different samples, including porosity (59%), superficial area per volume (14.4 mm−1), pore size (293 μm) and fiber diameter (305 μm). This indicates that the scaffold fabrication process is highly reproducible and that both the alkaline treatment and PEDOT:PSS coating of the scaffolds do not greatly affect the scaffolds’ morphological features.
Scaffolds | PCL | PCL(NaOH) | GOPS | GOPS(NaOH) | GOPS(NaOH)-Gel | DVS | DVS(NaOH) | DVS(NaOH)-Gel |
---|---|---|---|---|---|---|---|---|
Interconnectivity (%) | 99.9 | 100.0 | 99.9 | 100.0 | 99.9 | 99.9 | 100.0 | 99.9 |
Porosity (%) | 59.1 | 61.1 | 59.8 | 59.9 | 58.9 | 57.1 | 59.5 | 59.8 |
Superficial area per volume (mm−1) | 14.3 | 15.2 | 14.3 | 14.4 | 14.8 | 13.3 | 13.49 | 15.3 |
Pore size (μm) | 285 ± 33 | 287 ± 46 | 308 ± 42 | 294 ± 27 | 294 ± 28 | 280 ± 47 | 297 ± 35 | 299 ± 30 |
Fiber diameter (μm) | 311 ± 30 | 311 ± 50 | 290 ± 47 | 311 ± 27 | 308 ± 37 | 315 ± 50 | 304 ± 32 | 292 ± 30 |
In this work, the average porosity of the scaffolds obtained is 59%, slightly lower than the average porosity found for trabecular bone as described by Renders and colleagues70 (79.3 ± 5.1%) but higher than the value described for cortical bone porosity by Bousson and colleagues71 (15.88 ± 9.87%). We consider that the value obtained is appropriate for future bone TE applications, as it allows the growth and osteogenic differentiation of MSCs, with free flow of culture media.26 Potentially, these scaffolds can be used for the regeneration of trabecular bone or be integrated into cortical bone after appropriate cell colonization and ECM deposition.72
The next step in our work was to evaluate the mechanical properties of the obtained scaffolds under compression, to mimic the loads naturally exerted in bone tissue in vivo. The main results, including the obtained stress–strain curves, the compressive Young's modulus, and the maximum stress, are summarized in Fig. 5 and Table 3. The compressive modulus of PCL (8.8 ± 0.2 MPa) and PCL(NaOH) (8.6 ± 0.3 MPa) scaffolds indicates that the chemical treatment with NaOH did not impair the stiffness of the scaffold. Compared with PCL and PCL(NaOH) samples, no statistically significant changes in the compressive modulus occurred for samples GOPS (8.8 ± 0.5 MPa), GOPS(NaOH) (8.4 ± 0.5 MPa), DVS (8.8 ± 0.2 MPa), and DVS(NaOH) (9.1 ± 0.1 MPa). This indicates that the presence of a PEDOT:PSS coating does not compromise the stiffness of the scaffold. The incorporation of gelatin leads to a statistically significant increase in the compressive moduli of samples GOPS(NaOH)-Gel (10.2 ± 0.1 MPa) and DVS(NaOH)-Gel (10.6 ± 0.0 MPa). The obtained compressive modulus is lower than that obtained in our previous works,22 which we attribute to the use of a different commercially available PCL filament. Huang and colleagues73 tested PCL scaffolds prepared with different bioinks and found that the use of organic solvents for preparation (e.g., 2-butoxyethanol) lead to a decrease in the final scaffold stiffness (10 MPa). The authors attribute this decrease to the residual solvent that increases the PCL chain mobility and reduces the crystallization of PCL. However, osteogenic differentiation efficiency was not compromised in these scaffolds.
The Young's modulus values obtained for all scaffolds under compressive testing showed an inferior stiffness when comparing to the range found for cancellous/trabecular bone (50–100 MPa).17 However, these values vary greatly depending on the bone origin along with the sex (male/female vertebrae – 55.6/35.1 MPa; male/female tibia – 34.6/23.1 MPa), age and health conditions of the sample donor.74 The lower value obtained for the compressive modulus should not be seen as a limitation for using these scaffolds in bone applications, since bone TE strategies for defect repair in most demanding regions may include central rigid supports to guarantee proper load transfer and surroundings until cell colonization and mineralization can improve their mechanical properties.75–77 The obtained Young's modulus for the obtained PCL scaffolds is lower than the values reported in previous works using similar scaffolds.22,33,78 However, a study from Olubamiji and colleagues79 reported compressive modulus within the same range of the ones obtained in this work for PCL scaffolds with the same fiber orientation (0–90°), fiber diameter and similar porosity. These differences can be due to the properties of the used PCL raw material, including molecular weight and crystallinity.79,80 It was previously shown that the mechanical properties could be further finetuned by changing the architecture of the designed PCL scaffolds.21,79 This shows the versatility of our developed PCL-PEDOT:PSS scaffolds and its potential applications in BTE.
The maximum stress of samples GOPS (1.5 ± 0.4 MPa), GOPS(NaOH) (1.2 ± 0.4 MPa), DVS (1.3 ± 0.2 MPa), and DVS(NaOH) (1.6 ± 0.2 MPa) decreased significantly when compared with those of PCL and PCL(NaOH) samples, which did not break at 50 N/5 MPa. This suggests that the incorporation of the PEDOT:PSS coating on PCL scaffolds increases the fragility of the scaffolds. The incorporation of gelatin in the PEDOT:PSS coating improved the maximum stress of samples GOPS(NaOH)-Gel (no break) and DVS(NaOH)-Gel (3.3 ± 0.1 MPa). This is potentially due to the effect of more favorable mechanical properties of gelatin on the PEDOT:PSS coating.63
We hypothesized that the changes in the mechanical properties of PCL-PEDOT:PSS scaffolds could be due to changes in the materials chemistry due to pH and heat treatment. To understand this, we treated pristine PCL and PCL(NaOH) scaffolds with an aqueous solution of H2SO4 with a pH of 2, to mimic PEDOT:PSS incubation, and/or heated them at 50 °C, to mimic the drying/cross-linking conditions. The obtained results are summarized in Fig. S3 (ESI†). Neither of the conditions tested impaired the stress–strain curves of both PCL and PCL(NaOH) scaffolds, as neither of the scaffolds broke before 50 N/5 MPa was reached. What is also remarkable is the statistically significant increase in the compressive modulus of the samples. This leads us to hypothesize that the changes in the mechanical properties of PCL-PEDOT:PSS scaffolds are mainly caused by the PEDOT:PSS layer. It is possible that such a drastic change in the maximum stress of the samples is a consequence of the cross-linking between PCL and the PEDOT:PSS layer. Due to the brittleness of PEDOT:PSS, the PEDOT:PSS layer should break first during the compressive test.81,82 The presence of cross-linking bonds between PEDOT:PSS and PCL, via GOPS or DVS, can lead to the propagation of cracks to the PCL scaffold, favoring its mechanical break.
The suitability of scaffolds for bone TE applications will depend on their ability to be (bio)mineralized. In mature bone, hydroxyapatite [(Ca)10(PO4)6(OH)2] (HAp) composes 60% of the tissue vs. 40% of organic components, providing both mechanical and structural support to the body and acting as a calcium and phosphate ion deposit for the cells. Osteoblasts can regulate HAp formation through regulation of calcium secretion and phosphate metabolism. HAp is immobilized by type 1 collagen fibrils, the most abundant organic compound in bone (90%).83,84
The ability of a material to allow the deposition of HAp can greatly contribute to bone regeneration and allow adequate osteoblast/osteoclast colonization.42 We investigated the biomineralization of our scaffolds using SBF, a synthetic solution with the ionic composition and concentration as the human plasma. SBF has been used to evaluate the biomineralization of materials suitable for bone repair applications without the need for living cells. When materials are dipped in SBF, HAp gradually deposits on their surface. The more HAp is deposited, the more efficient cell colonization and tissue integration are expected to be. Fig. 6 summarizes the main results obtained. HAp deposition was evaluated through quantification of calcium content in the scaffolds tested (Fig. 6(A)) and complemented with SEM visualization of the deposited mineral crystals (Fig. 6(B)). Both PCL and PCL(NaOH) samples have small crystals deposited at their surface, and these were visually more numerous in PCL(NaOH). Both scaffolds had similar amounts of calcium (0.41 ± 0.36 ng mg−1vs. 0.44 ± 0.24 ng mg−1 respectively), and no statistically significant difference was found between them. The amount of calcium was higher for samples GOPS(NaOH) (2.66 ± 0.32 ng mg−1), GOPS(NaOH)-Gel (3.08 ± 0.21 ng mg−1), DVS(NaOH) (1.29 ± 0.58 ng mg−1) and DVS(NaOH)-Gel (1.97 ± 0.63 ng mg−1). Calcium content values for samples GOPS(NaOH) and GOPS(NaOH)-Gel were the highest among the different conditions and both were statistically different from those of pristine PCL and PCL(NaOH). Calcium contents for samples DVS(NaOH) and DVS(NaOH)-Gel were slightly lower and not statistically different from those for PCL/PCL(NaOH) samples and GOPS(NaOH)/GOPS(NaOH)-Gel samples. SEM images (Fig. 6(B)) revealed the presence of small crystal deposits on all samples, confirming the presence of HAp deposited on all the PEDOT:PSS coated samples.
The in vitro mineralization of PCL scaffolds had been described before. Xie and colleagues75 report the mineralization of PCL and PCL-poly(dopamine) electrospun fibers in 10x SBF (SBF ten times more concentrated). PCL alone allowed mineralization, with crystals being deposited at its surface, while PCL-poly(dopamine) greatly enhanced mineralization, with denser and regular crystals being deposited at its surface. The inclusion of electroconductive polymers and/or other bioactive cues also favors the mineralization of scaffolds. Park and colleagues85 reported an enhancement in the mineralization of PCL fibers when increasing amounts of poly(thiophene) nanoparticles are incorporated. Rajzer and colleagues86 reported successful mineralization of PCL electrospun fibers in 1x SBF when nano-HAp powder was incorporated, and even when poly(aniline) was printed on top. Overall, these observations support our observations of successful mineralization of both PCL/PCL(NaOH) samples and the enhancement observed when PEDOT:PSS coating was applied.
The differences in the calcium content between GOPS(NaOH) and DVS(NaOH) samples can be explained by differences in the surface properties of the PEDOT:PSS coatings obtained. Both GOPS and DVS react with PSS, via the formation of sulfonate esters (R–O–SO2–R′), to create insoluble moieties that anchor PEDOT chains. PEDOT:PSS films cross-linked with GOPS, which already possesses silicate (Si–O–CH3) groups, will also possess siloxane (Si–O–Si) groups at their surface.50 Siloxane groups are also present on bioglass, a material that greatly promotes mineralization of scaffolds.87 PEDOT:PSS films cross-linked with DVS are predicted to have sulfonyl (R–SO2–R′) and ether (R–O–R′) groups, after cross-linking with both PSS and EG.51,88 Calcium sulfate, a similar compound enriched in sulfur-based functional groups, has inferior in vivo performance for scaffold mineralization when compared with standard HAp.89 We hypothesize that siloxane and silicate groups from GOPS are more effective in adsorbing calcium than the sulfonyl/ether groups from DVS, which explains the different calcium contents in samples GOPS(NaOH) and DVS(NaOH).
The addition of gelatin to the PEDOT:PSS coating further enhances the calcium content of the coatings. Gelatin is mainly composed of denatured type 1 collagen, the main component of the bone ECM. Collagen promotes tissue mineralization through a combined mechanism of calcium absorption, potentially promoted by charged aminoacids, and mineral entrapment between fibrils. While the 3D structure of collagen is lost in gelatin, it is possible that the same charged aminoacids can serve as HAp nucleation sites and promote mineralization. This can explain the observed improvements in calcium content (Fig. 6(A)) and deposited minerals (Fig. 6(B)) observed for both samples GOPS(NaOH)-Gel and DVS(NaOH)-Gel.
Overall, the four combinations of PCL-PEDOT:PSS scaffolds tested allowed successful biomineralization. The results suggest (1) a positive influence of the PEDOT:PSS coating on HAp deposition, (2) a PEDOT:PSS coating cross-linked with GOPS promotes higher calcium deposition than the PEDOT:PSS coating cross-linked with DVS, and (3) the addition of gelatin slightly increases calcium deposition on the scaffolds.
The final step of our in vitro performance studies was to conduct a proliferation assay with MSCs. The main results are summarized in Fig. 7 and Table 3. The obtained metabolic activity is associated with the cell number, and changes in its value can be correlated with changes in cell number. The values obtained at day 1 were used to estimate cell adhesion (Table 3). The ANOVA test suggested statistically significant differences in adhesion between samples, but we could not find such differences after our post hoc analysis. The highest values of cell adhesion were observed for DVS(NaOH)-Gel (21.7 ± 5.9), GOPS(NaOH) (21.0 ± 5.5) and GOPS(NaOH)-Gel (14.2 ± 2.2). A constant increase in metabolic activity (Fig. 7(A)) was observed for all samples, except GOPS(NaOH)-Gel. At day 7, the cell metabolic activity was the highest for DVS(NaOH)-Gel, followed by PCL(NaOH), PCL and GOPS(NaOH). The obtained cells at day 7 were visualized using DAPI-Phalloidin staining. Both PCL and PCL(NaOH) (Fig. 7(B1) and (B2) respectively) allowed a homogeneous colonization of the scaffold by the MSCs. Samples GOPS(NaOH) and DVS(NaOH) (Fig. 7(C1) and (D1) respectively) show scaffold colonization by MSCs, but they form clumps instead and make less contact with the PEDOT:PSS coating. For samples GOPS(NaOH)-Gel and DVS(NaOH)-Gel (Fig. 7(C2) and (D2) respectively), cell spreading and colonization on the scaffolds is improved.
Our results suggest the incorporation of gelatin in samples cross-linked with DVS favored cell adhesion, proliferation, and scaffold colonization. This was expected since gelatin has been used in the design of scaffolds suitable for bone TE applications.90–92 The obtained positive cell and mineralization assay outcomes justify our choice of continuing further ES studies with sample DVS(NaOH)-Gel.
The first step was to determine a simpler modelling configuration that better describes the behavior of the filaments used to manufacture our scaffolds (Fig. S5, ESI†). Two configurations were envisaged: (a) the presence of a thin electroconductive PEDOT:PSS layer on top of an insulating material or (b) considering the whole filament to have the same electroconductivity as the PEDOT:PSS layer. The single 2D filament model reveals no predictable differences in the surrounding medium electrical field. Based on these results, the filament fibers that compose the orthogonal scaffold at the single well 3D model were parameterized as a single material loaded with each coating's electrical properties (configuration b).
The next step was to evaluate the influence of the PEDOT:PSS coatings on electrical field (EF) distribution around the whole scaffold. To do this, we measured, experimentally, the consequences of the application of a defined stimulation protocol (1.2 V) to osteogenic medium and using the same 6-well plate direct coupled stimulation setup for the electrical stimulation studies. We measured a peak of electric current of 0.067 A, followed by a sudden current drop that stabilizes around 0.001 A. With these currents, the model of a single well was computed to find the predicted EF of each coating material, and the results are shown in Table 5 and Fig. S6 (ESI†). We observed minimal changes on EF volumetric distribution when we compared the influence of the different coatings tested in our study (Fig. S5, ESI†). As such, we focused our analysis on the comparison between PCL (insulating) and DVS(NaOH)-Gel (electroconductive) samples.
Scaffolds | PCL/PCL(NaOH) | GOPS | GOPS(NaOH) | GOPS(NaOH)-Gel. | DVS | DVS(NaOH) | DVS(NaOH)-Gel. | |
---|---|---|---|---|---|---|---|---|
0.067 A | EF (average) | 312.45 | 34.352 | 74.40 | 13.004 | 29.14 | 39.96 | 22.56 |
EF (maximum) | 1648.50 | 304.25 | 550.77 | 138.57 | 269.52 | 338.40 | 220.73 | |
EF (minimum) | 0.63 | 0.08 | 0.81 | 0.038 | 0.08 | 0.25 | 0.04 |
Fig. 8 and Table 5 summarize the obtained results on the distribution of the applied electrical field on PCL and DVS(NaOH)-Gel samples. We observed higher field amplitudes (EF (maximum) − EF (minimum)) on the PCL sample, independently of the simulated current. A visual analysis to the obtained heat map of PCL (Fig. 8(B)) shows that this arises from heterogeneous electrical field distribution throughout the scaffold. We hypothesize that this is caused by scaffold geometry that creates natural obstacles that oppose liquid flow and charge dispersion. In sample DVS(NaOH)-Gel, such a phenomenon is not observed unless a finer scale is used (Fig. 8(C)).
Our results demonstrate that the presence of the PEDOT:PSS coating can ease charge movement throughout the whole scaffold and generate a more homogeneous EF when external ES is applied (Fig. 8(D)). We expect that this will allow a more homogeneous stimulation of cultured cells and avoid the formation of faradaic products, such as radical oxygen species (ROS), due to high intensity electrical fields. ROS formation is possible when a high EF (10 V cm−1) is used for ES and can have beneficial effects on cardiac cell differentiation94 and even lung cancer cell treatment.95 Similar or even higher EF values are observed for our pristine PCL sample, increasing the potential of ROS formation with ES. For bone TE strategies, ROS formation has mixed effects on bone health. Some studies claim that ROS formation should ideally be minimized due to its negative impact on osteoblast viability and differentiation, and enhancement of osteoclast differentiation and activity.96,97
The metabolic activity of MSCs cultured under osteogenic induction conditions in DVS(NaOH)-Gel and PCL(NaOH) scaffolds with(ESTIM)/without(NO STIM) ES was monitored for 21 days (Fig. 9(A)). For all the conditions, the metabolic activity increased overtime throughout the 21 days of osteogenic differentiation. A lower cell metabolic activity was observed for the conductive DVS(NaOH)-Gel scaffolds in comparison to the non-conductive PCL(NaOH) scaffolds. A similar trend was observed by Abedi and colleagues,98 which reported lower cell metabolic activities in conductive chitosan/polyvinyl alcohol/MWCNTS in comparison to the chitosan/polyvinyl alcohol counterparts. For both scaffold conditions, ESTIM leads to a decrease in the metabolic activity of MSCs, which is concordant with results from previous ES studies performed by other authors using dental pulp stem cells99 and BM-MSCs cultured on 3D collagen type I scaffolds.100 In our previous study about the development of ECM-decorated scaffolds for bone TE, we observed lower cell metabolic activities during MSC osteogenic differentiation, and this did not affect the cells’ osteogenic potential.26 Moreover, application of ES has been shown to slow down neural cell proliferation while improving their differentiation.101
The main focus of this work was to develop 3D extruded conductive scaffolds and combine them with ES to promote the osteogenic differentiation of MSCs envisaging bone TE applications. At the end of the ES experiment, samples for the four different experimental conditions were obtained and evaluated towards production of bone ECM proteins and minerals (Fig. 9(B)–(D)), and also expression of bone-specific marker genes (Fig. 10).
Xylenol orange staining images evidenced a more intense presence of mineral deposits in the conductive DVS(NaOH)-Gel scaffolds when compared to PCL(NaOH) scaffolds. When ES was applied, both scaffold types showed a much more intense and well-distributed mineral deposition, suggesting an important role of ES in the enhancement of tissue mineralization by differentiating MSCs. This is in agreement with what was observed in a recent study by Dixon & Gomulion,103 which showed an improved mineralization (assessed by xylenol orange staining) after culturing MC3T3-E1 pre-osteoblasts in conductive PLA scaffolds exposed to ES when compared to non-conductive PLA scaffolds both with and without ES.
Overall, our immunostaining and xylenol orange staining results suggest that our electroconductive scaffold DVS(NaOH)-Gel provides a better support for MSC osteogenic differentiation. When ES is applied, the presence of terminal differentiation marker OPN and calcium deposition increase. To further confirm these results, quantitative assays were performed.
The results from the calcium quantification assay performed after 21 days of osteogenic differentiation under the four different experimental conditions are presented in Fig. 9(D). Our results evidence the positive effect of ES on the calcium production by MSCs in both scaffold types; however, such an effect was only statistically significant when the cells were cultured on conductive scaffolds. This positive role of ES on MSC-based mineralization has been suggested to occur through the activation of the calcium-calmodulin pathway and by the upregulation of bone morphogenetic proteins (BMPs) and transforming growth factor-β (TGF-β) expression.8,110
The DVS(NaOH)-Gel scaffolds presented significantly higher calcium amounts than the PCL(NaOH) counterparts (No STIM – 1.54 fold), even when ES was applied (ESTIM – 2.46 fold). These observations are concordant with the results from xylenol orange staining (Fig. 9(B)) and other studies in the literature that report an enhancement in calcium production when secreting-cells are cultured on electroconductive substrates.102,103,111
Notably, combining DVS(NaOH)-Gel with ES resulted in significantly higher calcium deposition (2.29 fold increase vs. DVS(NaOH)-Gel No STIM and 2.46 fold increase vs. PCL(NaOH) ESTIM). This synergistic effect between conductive scaffolds and ES in promoting calcium production by MSCs is supported by previous work in the literature. Chen and colleagues112 reported an increase of calcium deposition by human adipose-derived stem cells on PEDOT:PSS/MWNT substrates after the application of ES (AC, 0.2 V, 0.01 Hz, total stimulation of 1–14 days, after chemical induction). Moreover, they observed a concomitant enhancement in osteogenic differentiation after two weeks of culture.
The initial steps of MSC's osteogenic commitment are regulated by the expression of transcription factors such as RUNX2, followed by OSX in a more advanced stage.113 ES has been reported to activate different signaling pathways (e.g. BMP/Smad, calcium-calmodulin or MAPK pathways) that enhance the expression of osteogenic genes RUNX2 and OSX.114 Our results showed upregulation of RUNX2 and OSX expression when the cells were differentiated in conductive DVS(NaOH)-Gel scaffolds, regardless of exposure to ES. These results suggest a predominant effect of the scaffold electroconductivity in promoting the expression or the early osteogenic marker genes RUNX2 and OSX. Nalesso and colleagues115 reported similar observations using 3D printed PCL/Graphene scaffolds. OPN gene upregulation observed for all experimental groups suggests a mature state of the bone ECM secreted by differentiating hBM-MSCs. However, the effects of ES on OPN gene expression were opposite for non-conductive (downregulation in PCL(NaOH) STIM) and conductive scaffolds (upregulation (albeit non-significant) on DVS(NaOH)-Gel ESTIM). OPN has been associated with the regulation of several bone physiological processes such as collagen organization, calcification and angiogenesis. OPN has also been described as a regulator of the nucleation of calcium phosphate during mineralization, which might arise from its negatively charged motifs (e.g. aspartic acid residues) that have a high affinity to calcium adsorption.116
Intracellular calcium oscillations have also been shown to regulate ES-mediated MSC osteogenesis, since calcium ions are well-described second messengers involved in several cellular processes. As a response to membrane depolarization caused by ES, calcium ion channels, such as voltage-gated calcium channels (VGCC), can mediate the influx of calcium ions, which in turn might activate ERK1/2, one of the main effectors of the MAPK pathway.114 The calcium ions inside the cell can also bind to the protein calmodulin, initiating the calcium-calmodulin signaling cascade. This pathway might be involved in the activation of the transcription factor Osx, which is known to regulate the expression of several osteogenic marker genes including ALP, OC and OPN.117
Our results identified clearly a synergistic effect of conductive scaffolds and ES in enhancing the osteogenic differentiation of hBM-MSCs, as demonstrated by the significant upregulation of CACNA1C, COL I and OC marker genes. In accordance with our results, Liu and colleagues118 also reported that combining ES with conductive 3D-printed poly(propylene fumarate) scaffolds coated with CNTs significantly enhanced osteogenic gene expression in MC3T3 pre-osteoblasts. CACNA1C gene encodes for a subunit of L-type VGCC, which have been shown to play a role in the signaling cascade (e.g., promote RUNX2 and OSX expression) regulating human MSC osteogenic differentiation and calcium deposition.119 In fact, a previous study by S. Camarero-Espinosa and colleagues120 showed that blocking L-VGCC lead to the downregulation of bone-specific gene (COL I, RUNX2, and OC) expression, impairing hBM-MSC ostegenic differentiation. COL I and OC upregulation has been associated with enhanced bone mineralization.120,121 Thus, the significant upregulation of COL I and OC gene expressions resulting from the combination of conductive scaffolds and ES is in accordance with the higher calcium contents (mineralization) observed before (Fig. 9(D)). Our results demonstrate the combined effect of conductive materials and ES as a strategy to enhance the osteogenic differentiation potential of hBM-MSCs towards improved bone TE strategies.
The chemistry used for the production of the PCL-PEDOT:PSS scaffolds is simple to implement and versatile in its applications. For example, other polyesters widely used in 3D-extrusion (e.g. poly(lactic acid), poly(glycolic acid), poly(vinyl alcohol)) have similar chemical groups to PCL.19 As such, we also hypothesize that our method is versatile enough to be used with other support polymers.
Gelatin immobilization was not essential for our scaffold design, as PEDOT:PSS can support cell adhesion and growth.37,40 However, we observed slight improvements in calcium deposition and cell spreading as a consequence (Fig. 6 and 7), which we decided to harness for our final design. Overall, the different cross-linkers used in the PEDOT:PSS coating can be used to immobilize other bioactive cues, including inorganic (e.g. hydroxyapatite, bioglass) or organic ones (e.g. extracellular matrix or other proteinaceous components). Considering these scaffolds can be used as implants for different areas of the bone tissue (e.g. cortical bone, cancellous/trabecular bone, bone marrow, and growth plate), we believe such versatility will allow fine-tuning the biochemical properties of the applied PEDOT:PSS coating to specific tissue requirements and/or cell niches.
Biodegradation is an important factor to consider when designing scaffolds for bone tissue engineering. PCL is reported to slowly degrade under physiological conditions, which can be accelerated by the presence of cells and/or enzymes (e.g. lipase).20,123 PEDOT:PSS cannot biodegrade under physiological conditions. However, due to its physico-chemical properties, it can intimately interact with cells and be integrated into newly formed tissue without inducing inflammation and the formation of scar tissue.124–126 We hypothesize that the PEDOT:PSS coating might slightly delay the degradation profile of PCL. Moreover, the inclusion of gelatin within the coating might facilitate substrate remodeling and help enzymes penetrate inside the PCL skeleton. Such a phenomenon will need to be evaluated using appropriate in vivo models to better understand the degradation kinetics of our scaffolds after implantation.
Since cancellous/trabecular bone is highly vascularized, future studies should also aim at understanding the neovascularization potential of our scaffolds. This is of particular interest for future application in therapeutics, as ES is described to also enhance tissue vascularization.127 Future studies, whether in vitro (co-culture of hBM-MSCs and endothelial cells) or in vivo (histological analysis after implantation), should be performed to study a potential synergy between ES and our scaffolds.
ES of hBM-MSCs undergoing osteogenic differentiation on conductive scaffolds greatly enhanced the deposition of cell-secreted calcium and improved the differentiation profile. This is in accordance with current literature.128 Nevertheless, few ES studies for BTE applications were conducted in combination with support electroconductive materials.10,129 PEDOT:PSS and other electroconductive materials possess delocalized charges that can promote ion adsorption and induce mineral deposition, and therefore can be advantageous for BTE applications. We found that both ES and PEDOT:PSS based scaffolds can synergically improve cell-secreted calcium deposition while accelerating osteogenic differentiation (upregulation of COL I, OC and CACNA1C genes, accompanied by an increase in the expression of proteins OPN and COL I). Our results underlay the positive effect of combining electroconductive support materials and ES towards more efficient BTE strategies. These can potentially be used for studying the effect of ES as a therapeutic option to treat non-union fractures or to revert the progression of bone diseases, e.g. osteoporosis.
Footnotes |
† Electronic supplementary information (ESI) available. See DOI: https://doi.org/10.1039/d3tb02673f |
‡ These authors contributed equally to this work. |
This journal is © The Royal Society of Chemistry 2024 |