Issue 22, 2025

Development of a NS-CDs/fluorescein ratiometric fluorescent sensor-integrated smartphone platform for rapid and specific detection of Mn(vii) and captopril

Abstract

The construction of a ratiometric fluorescent sensor based on nitrogen-doped carbon dots (NS-CDs) and fluorescein has been reported for the detection of Mn(VII) and captopril. The detection mechanisms for Mn(VII) and captopril are based on the inner filter effect (IFE) and a redox reaction, respectively. The sensor showed good linearity in the detection range of 0.12–100 μM for Mn(VII) and 0.52–300 μM for captopril, with limits of detection (LODs) of 0.12 μM and 0.52 μM, respectively. Furthermore, a smartphone-based platform for the detection of Mn(VII) and captopril was developed, based on the dual-signal response of color and fluorescence intensity. The system displayed linear signal changes with increasing Mn(VII) and captopril concentrations in the ranges of 0.32–100 μM and 0.52–300 μM, with LODs of 0.32 μM and 0.52 μM, respectively. Finally, the ratiometric sensor was validated for the determination of Mn(VII) and captopril in herb and captopril tablet samples, demonstrating its broad applicability and versatility as a portable, sensitive, and specific detector for Mn(VII) and captopril in various sample types. Overall, our ratiometric fluorescent sensor has potential as a portable, on-site detector for Mn(VII) and captopril analysis.

Graphical abstract: Development of a NS-CDs/fluorescein ratiometric fluorescent sensor-integrated smartphone platform for rapid and specific detection of Mn(vii) and captopril

Supplementary files

Transparent peer review

To support increased transparency, we offer authors the option to publish the peer review history alongside their article.

View this article’s peer review history

Article information

Article type
Paper
Submitted
19 Feb 2025
Accepted
10 May 2025
First published
12 May 2025

Anal. Methods, 2025,17, 4665-4678

Development of a NS-CDs/fluorescein ratiometric fluorescent sensor-integrated smartphone platform for rapid and specific detection of Mn(VII) and captopril

C. Liu, H. Qi, J. Zhang, J. Li, T. Jing, Q. Li, L. Qiu and X. Zhu, Anal. Methods, 2025, 17, 4665 DOI: 10.1039/D5AY00275C

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements