Weiji
Dai
*a,
Bing
Wu
a,
Fan
Zhang
a,
Yuxi
Huang
a,
Cuijiao
Zhao
a,
Yudong
Zhang
a,
Can
Cui
a,
Jing
Guo
b and
Saifang
Huang
*a
aSchool of Materials Science and Engineering, Jiangsu University of Science and Technology, Zhenjiang 212003, China. E-mail: daiweiji@just.edu.cn; s.huang@just.edu.cn
bSchool of Resources and Materials, Northeastern University at Qinhuangdao, Qinhuangdao 066004, China
First published on 9th January 2025
Due to their ease of synthesis and large specific surface area, Ni(OH)2 nanosheets have emerged as promising electrochemical sensing materials, attracting significant attention in recent years. Herein, a series of oxy-hydroxides based on Ni(OH)2 nanosheets, including NiOx/Ni(OH)2@NF and (MNi)Ox/Ni(OH)2@NF (M = Co, Fe, or Cr), are successfully synthesized via the electrochemical oxidation and incorporation strategies. Electrochemical tests demonstrate that these Ni(OH)2-based oxy-hydroxides exhibit excellent electrochemical oxidation activity for glucose in alkaline electrolyte. Among these, (CoNi)Ox/Ni(OH)2@NF displays higher sensitivity of 3590.3 μA mM−1 cm−2 across a broad linear range of 10 μM to 1.14 mM, with a rapid current response time of less than 4 s. The superior sensing performances of (CoNi)Ox/Ni(OH)2@NF are attributed to the formation of abundant Ni3+ species and reactive-O atoms due to the electrochemical oxidation, and the synergistic effects of Co/Ni active sites resulting from the electrochemical incorporation process. In addition, the (CoNi)Ox/Ni(OH)2@NF demonstrates good stability and reproducibility for glucose sensing. This work fully leverages the significance of surface reconstruction of Ni(OH)2, providing new insights for the application of transition metal-based oxy-hydroxide materials in bio-sensing.
Currently, a variety of materials have been investigated as non-enzymatic glucose sensors, such as precious metals represented by Pt and Au.13,14 Pt is well-known as a state-of-the-art electrocatalyst for the hydrogen evolution reaction.15,16 Here, Pt also shows excellent catalytic ability for glucose oxidation; however, it has low anti-interference ability since it can be easily affected by uric acid in the blood.17 Au has a strong selectivity and a low oxidation potential for glucose detection, but its high-cost has limited its commercial application.18,19 Fortunately, non-precious transition metal-based materials represented by Co, Ni, Cu, and their compounds have been intensively investigated as promising candidates for glucose sensing.20–22 Benefiting from the well-designed nanostructure, researchers have obtained a series of transition metal-based alloys, oxides, and hydroxides with a large specific surface area and abundant active sites for non-enzymatic glucose detection.23–25 It is worth mentioning that transition metal-based oxy-hydroxides are considered to be the true active materials for glucose sensing according to the widely accepted catalytic mechanism of glucose oxidation,26,27 and thus the M2+/M3+ couples are identified as the active sites. In this regard, designing an active surface with abundant M2+/M3+ couples is a promising strategy to enhance the sensing ability for glucose.28,29 Moreover, introducing extra catalytic sites to achieve synergistic effects can further contribute to the catalytic performance of glucose oxidation.30,31
Based on the above considerations, bimetallic oxy-hydroxides based on Ni(OH)2 nanosheets ((CoNi)Ox/Ni(OH)2@NF) were designed and prepared as high performance non-enzymatic sensors for glucose. In this work, electrochemical oxidation was conducted on Ni(OH)2 nanosheets to prepare an active surface with abundant Ni3+ species (NiOOH) and reactive-O atoms. Subsequently, Co2+ ions were incorporated onto the active surface via electrochemical deposition, thus forming a bimetallic oxy-hydroxide electrocatalyst ((CoNi)Ox/Ni(OH)2@NF). XPS results revealed that highly active Co4+ species were obtained on the surface of (CoNi)Ox/Ni(OH)2@NF. With the help of abundant reactive-O atoms, the Co4+ species can accelerate the transformation of Ni2+ to Ni3+ species (NiOOH), which has been recognized as one of the most active materials for oxidizing glucose to gluconolactone. Thanks to the synergistic effects of the Co/Ni bimetallic sites, the (CoNi)Ox/Ni(OH)2@NF exhibited good glucose sensing performance, including a high sensitivity of 3590.3 μA mM−1 cm−2 in a linear range of 10 μM to 1.14 mM, and a fast response time of less than 4 s. Meanwhile, the obtained (CoNi)Ox/Ni(OH)2@NF had favorable selectivity and stability in glucose sensing.
The preparation processes of (FeNi)Ox/Ni(OH)2@NF and (CrNi)Ox/Ni(OH)2@NF are similar to that of (CoNi)Ox/Ni(OH)2@NF except for the electrolyte used for electrochemical incorporation. As for the preparation of (FeNi)Ox/Ni(OH)2@NF, 0.4041 g Fe(NO3)3·9H2O was dissolved in 50 mL of deionized water to obtain the electrolyte. Similarly, 0.4002 g Cr(NO3)3·9H2O was dissolved in 50 mL of deionized water to obtain the electrolyte for the preparation of (CrNi)Ox/Ni(OH)2@NF.
The surface reconstructed Ni(OH)2 nanosheets were further investigated via TEM methods to show the changes that resulted from the electrochemical deposition. As shown in Fig. 2a, the TEM image of a (CoNi)Ox/Ni(OH)2 nanosheet displays obvious differences between the rim and core of the nanosheet. Selected area electronic diffraction (SAED) was performed on the core area of the (CoNi)Ox/Ni(OH)2 nanosheet, showing a clear crystal structure corresponding to the hexagonal phase of Ni(OH)2. According to the SAED pattern in Fig. 2b, the marked diffraction points can well correspond to the (100) and (111) planes of Ni(OH)2. Meanwhile, the high-resolution TEM (HRTEM) image of the core area of the (CoNi)Ox/Ni(OH)2 nanosheet clearly displays an interplanar spacing of about 0.258 nm (Fig. 2c), confirming the (100) plane of Ni(OH)2. However, the TEM image in Fig. 2d reveals a non-crystalline characteristic for the rim area of the (CoNi)Ox/Ni(OH)2 nanosheet as marked with the white dashed line, indicating that the surface of the Ni(OH)2 nanosheet was reconstructed due to the electrochemical oxidation and deposition. The high angle annular dark field (HAADF) image and elemental mappings in Fig. 2e show that Co2+ ions were successfully incorporated onto the reconstructed surface of the NiOx/Ni(OH)2@NF, since the elements Co, Ni, and O were uniformly distributed across the whole nanosheet. In addition, the EDS results reveal that the atomic ratio of incorporated Co is about 0.71% (Fig. S5†).
To elucidate the changes in elemental composition and chemical state after the electrochemical deposition, XPS analysis was further performed on the (CoNi)Ox/Ni(OH)2@NF electrode. As shown in Fig. 3a, the survey spectra of (CoNi)Ox/Ni(OH)2@NF clearly display the binding energy peaks of elements Ni, Co, and O, confirming the successful incorporation of Co2+ ions onto the surface of NiOx/Ni(OH)2@NF. The binding energy peaks of Ni2+ 2p3/2 (855.7 eV) and Ni2+ 2p1/2 (873.3 eV) confirm that Ni–OH bonds remained on the reconstructed surface (Fig. 3b).34,35 Meanwhile, the binding energy peaks located at 857.0 and 874.9 eV typically belonging to Ni3+ 2p3/2 and Ni3+ 2p1/2 reveal the existence of Ni3+ species (NiOOH).36 This indicates that NiOOH remained after the electrochemical deposition process. Fig. 3c shows the high-resolution XPS spectra of Co 2p, where prominent binding energy peaks at 781.0 and 796.8 eV corresponding to Co 2p3/2 and Co 2p1/2, respectively, confirm the successful incorporation of Co2+ ions onto the surface of NiOx/Ni(OH)2@NF.37–39 The deconvoluted peaks located at 781.9, 797.2, 780.6, and 796.2 eV correspond to Co2+ 2p3/2, Co2+ 2p1/2, Co3+ 2p3/2, and Co3+ 2p1/2, respectively.40,41 More importantly, the high-resolution XPS spectra of Co 2p further display two binding energy peaks located at 783.4 and 798.2 eV, which can correspond to Co4+ 2p3/2 and Co4+ 2p1/2, respectively. This indicates that highly active Co4+ species (CoO2) were prepared on the surface of (CoNi)Ox/Ni(OH)2@NF.42 In addition, the deconvoluted O 1s spectra in Fig. 3d reveal the formation of M–O (530.9 eV) and M–OH (531.5 eV) bonds, corresponding to the derived oxy-hydroxides.41,43 In brief, the XPS results confirm the successful preparation of bimetallic oxy-hydroxides on the surface of (CoNi)Ox/Ni(OH)2@NF.
![]() | ||
Fig. 3 (a) Survey spectra of (CoNi)Ox/Ni(OH)2@NF. High-resolution XPS spectra: (b) Ni 2p, (c) Co 2p, and (d) O 1s. |
To preliminarily investigate the catalytic performance of (CoNi)Ox/Ni(OH)2@NF towards glucose oxidation, CV tests were conducted with and without the addition of glucose in 0.1 M NaOH solution. As shown in Fig. 4a, the CV curve of (CoNi)Ox/Ni(OH)2@NF exhibits an oxidation peak near 0.58 V (vs. Ag/AgCl) and a reduction peak near 0.14 V (vs. Ag/AgCl) in the absence of glucose, typically indicating that Co2+/Ni2+ are oxidized to Co3+/Ni3+ at around 0.58 V (vs. Ag/AgCl), and Co3+/Ni3+ are reduced back to Co2+/Ni2+ at approximately 0.14 V (vs. Ag/AgCl).44 With the addition of 1 mM glucose, the response current was significantly increased with the oxidation peak shifting to around 0.6 V (vs. Ag/AgCl) during the CV test. The obviously increased oxidation current density can be ascribed to the oxidation of glucose by the Co/Ni sites of the bimetallic oxy-hydroxides. As reported in the literature, the Ni3+ species (NiOOH) were regarded as one of the most active materials for oxidizing glucose to gluconolactone, regardless of the original form of nickel-based materials.45 Meanwhile, the Co4+ species (CoO2) were also recognized as active materials for glucose sensing.46 Therefore, based on the valence state changes of Ni3+ and Co4+ species during glucose oxidation, the following sensing mechanism should be included for (CoNi)Ox/Ni(OH)2@NF:
Co2+/Ni2+ → Co3+/Ni3+ + e− | (1) |
Co3+ → Co4+ + e− | (2) |
Ni3+ + Glucose → Ni2+ + Gluconolactone | (3) |
Co4+ + Glucose → Co3+ + Gluconolactone | (4) |
More importantly, a new pathway for oxidizing glucose to gluconolactone was proposed based on the reactive-O atoms of (CoNi)Ox/Ni(OH)2@NF, since the reactive-O atoms can contribute to the formation of Ni3+ species (NiOOH). With the oxidative Co4+ species as electron acceptors, the Ni–O (reactive-O atoms adsorbed on Ni2+ sites) can bond with adsorbed OH− to form Ni–OOH (Ni3+ species). The corresponding sensing mechanism was inferred as follows:
Co4+ + Ni2+ + Oads + Glucose → Co3+ + Ni2+ + Gluconolactone | (5) |
This new pathway can make use of Ni2+ sites for oxidizing glucose to gluconolactone with the help of reactive-O atoms and Co4+ species, thus enhancing the sensing performance.
CV tests were also performed on Ni(OH)2@NF, NiOx/Ni(OH)2@NF, (FeNi)Ox/Ni(OH)2@NF, and (CrNi)Ox/Ni(OH)2@NF electrodes to show the current response for glucose detection. In Fig. S6,† all of the prepared electrodes show ability for glucose detection. However, the (CoNi)Ox/Ni(OH)2@NF exhibits a current density of 12.8 mA cm−2 at the oxidation potential of 0.6 V (vs. Ag/AgCl), higher than that of both the Ni(OH)2@NF (5.0 mA cm−2) and NiOx/Ni(OH)2@NF (11.2 mA cm−2) electrodes (Fig. 4b). The significant improvement of NiOx/Ni(OH)2@NF compared to Ni(OH)2@NF can mainly be ascribed to the formation of more Ni3+ species due to the electrochemical oxidation. With the incorporation of Co2+ ions as well as the derived Co4+ ions, the synergistic effects between the Co/Ni catalytic sites further enhanced the electrocatalytic performance of glucose oxidation. In Fig. S7,† the glucose sensing performance of Co/Ni(OH)2@NF for which the Co ions were directly deposited on the surface of Ni(OH)2@NF was evaluated. The response current of Co/Ni(OH)2@NF with glucose addition is only 4.9 mA cm−2, which is obviously lower than that of (CoNi)Ox/Ni(OH)2@NF. It is worth noting that the ratio of Ni3+ species to reactive-O atoms (Oads) for Ni(OH)2@NF is lower than that of NiOx/Ni(OH)2@NF (Fig. S3†). That is to say, without enough Ni3+ species and reactive-O atoms, the glucose sensing performance of Co4+ species was significantly restricted. Thus, the enhanced glucose sensing performance of (CoNi)Ox/Ni(OH)2@NF can be ascribed to the synergistic effects between Ni and Co catalytic sites as shown in mechanism (3), (4), and (5). However, mechanism (4) and (5) for the (FeNi)Ox/Ni(OH)2@NF and (CrNi)Ox/Ni(OH)2@NF electrodes may be unusable due to the lower activity of Fe2O3 and Cr2O3. As a result, the response current densities of the (FeNi)Ox/Ni(OH)2@NF (9.6 mA cm−2) and (CrNi)Ox/Ni(OH)2@NF (9.8 mA cm−2) electrodes are lower than that of (CoNi)Ox/Ni(OH)2@NF (Fig. 4c).
Fig. 4d shows the CV curves of (CoNi)Ox/Ni(OH)2@NF in solutions with varying concentrations of glucose. The current density at the oxidation potential gradually increased with increasing glucose concentration, indicating that (CoNi)Ox/Ni(OH)2@NF possesses good catalytic ability towards glucose oxidation over a wide concentration range, thus highlighting its potential for constructing glucose sensors.47 CV tests were also conducted on the Ni(OH)2@NF, NiOx/Ni(OH)2@NF, (FeNi)Ox/Ni(OH)2@NF, and (CrNi)Ox/Ni(OH)2@NF electrodes as shown in Fig. S8.† Similarly, all of the prepared electrodes exhibit an enhanced response current on increasing the concentration of glucose in solution, demonstrating the effective electrocatalytic ability of the Ni(OH)2@NF, NiOx/Ni(OH)2@NF, (FeNi)Ox/Ni(OH)2@NF, and (CrNi)Ox/Ni(OH)2@NF electrodes towards glucose detection. Fig. 4e presents the CV curves of (CoNi)Ox/Ni(OH)2@NF in a solution containing 0.1 M NaOH and 1 mM glucose, recorded at different scan rates ranging from 10 to 100 mV s−1. As shown in Fig. 4f, the corresponding oxidation current density improved with increasing scan rate, showing a linear relationship with the square root of the scan rate, and revealing a diffusion-controlled electrochemical process.48 The CV curves of the other four electrodes at different scan rates are shown in Fig. S9,† similarly demonstrating the corresponding linear relationships (Fig. S10†).
To determine the optimal potential of (CoNi)Ox/Ni(OH)2@NF for glucose detection, chronoamperometry tests with incremental addition of 1 mM glucose were applied at potentials ranging from 0.4 to 0.65 V (vs. Ag/AgCl). As shown in Fig. 5a, the (CoNi)Ox/Ni(OH)2@NF electrode exhibits an obvious current response to glucose across all the chosen voltages applied. The corresponding ΔI increased with higher voltages applied, reaching the maximum value at 0.6 V (vs. Ag/AgCl) and decreasing at 0.65 V (vs. Ag/AgCl). In Fig. 5b, the corresponding concentration-current fitting lines of different applied voltages display that the largest slope appeared at 0.6 V (vs. Ag/AgCl). In this regard, the optimal potential of (CoNi)Ox/Ni(OH)2@NF for glucose detection is determined to be 0.6 V (vs. Ag/AgCl), and thus the voltage of 0.6 V (vs. Ag/AgCl) was selected as the working voltage for (CoNi)Ox/Ni(OH)2@NF in subsequent measurements. With the same testing method, the optimal potentials for the Ni(OH)2@NF, NiOx/Ni(OH)2@NF, (FeNi)Ox/Ni(OH)2@NF, and (CrNi)Ox/Ni(OH)2@NF electrodes were determined to be 0.6, 0.6, 0.5, and 0.6 V (vs. Ag/AgCl), respectively (Fig. S11†).
The detailed glucose sensing performance of (CoNi)Ox/Ni(OH)2@NF was obtained through a chronoamperometry test by sequentially adding glucose at 50 s intervals. The amount of glucose addition changed every 150 s, and these changes were marked with downward pointing arrows and the corresponding amounts of glucose on the i–t curve. As the i–t curve in Fig. 5c shows, the current density quickly rises to a steady state with the addition of glucose, demonstrating its efficient glucose sensing capability. A noticeable current response is observed starting from the glucose concentration of 10 μM, indicating sensitive detection at low concentrations. Furthermore, the response current continuously improves with increasing concentration of glucose until 11.04 mM. The linear fitting between glucose concentration and response current is depicted in Fig. 5d, showing a significant linear relationship within the range of 10 μM to 1.14 mM. The linear fitting equation is I(mA) = 3.5903C(mM) + 2.133, with an R2 value of 0.9969, yielding a sensitivity of 3590.3 μA mM−1 cm−2. Additionally, i–t curves with varying glucose concentrations were recorded for the Ni(OH)2@NF, NiOx/Ni(OH)2@NF, (FeNi)Ox/Ni(OH)2@NF, and (CrNi)Ox/Ni(OH)2@NF electrodes as shown in Fig. S12.† According to the linear fitting results in Fig. S13,† the corresponding sensitivity values for Ni(OH)2@NF, NiOx/Ni(OH)2@NF, (FeNi)Ox/Ni(OH)2@NF, and (CrNi)Ox/Ni(OH)2@NF within their respective response ranges are reported as 698.3, 1504.0, 637.7, and 2810.6 μA mM−1 cm−2, respectively (Fig. 5e). Furthermore, the sensitivity of (CoNi)Ox/Ni(OH)2@NF is competitive with the recently reported non-enzymatic electrocatalysts as shown in Table S1.† This highlights that (CoNi)Ox/Ni(OH)2@NF exhibits outstanding sensitivity, making it advantageous for catalyzing glucose oxidation. Apart from the sensitivity, the response time is also crucial in evaluating the glucose sensing performance. Fig. 5f demonstrates that (CoNi)Ox/Ni(OH)2@NF achieves a rapid response within 4 s upon adding 1 mM glucose to the electrolyte, indicating its potential for real-time glucose concentration detection. The i–t curves to determine the response times of the Ni(OH)2@NF (4 s), NiOx/Ni(OH)2@NF (4 s), (FeNi)Ox/Ni(OH)2@NF (6 s), and (CrNi)Ox/Ni(OH)2@NF (10 s) electrodes are shown in Fig. S14.† As a result, the (CoNi)Ox/Ni(OH)2@NF exhibits a lower response time, showing a rapid response for glucose sensing (Fig. 5g).
Considering that for practical applications glucose sensors must exhibit specificity in detecting target analytes among various interfering substances commonly found in serum, the anti-interference performance was investigated through a chronoamperometry test by adding AA, UA, DA, NaCl, and fructose. Fig. 5h illustrates that the (CoNi)Ox/Ni(OH)2@NF electrode displays no significant fluctuations when adding AA, UA, DA, NaCl, and fructose into the electrolyte. However, it still maintains a sensitive response to glucose even after sequential addition of these potential interferents, demonstrating its robust anti-interference capability. Comparable results are observed for the Ni(OH)2@NF, NiOx/Ni(OH)2@NF, (FeNi)Ox/Ni(OH)2@NF, and (CrNi)Ox/Ni(OH)2@NF electrodes as shown in Fig. S15.† Stability is essential for prolonged sensor application. Fig. 5i shows that (CoNi)Ox/Ni(OH)2@NF keeps a high current response in a 2000 s test period, indicating its excellent electrochemical stability suitable for long-term testing. Stability tests for the Ni(OH)2@NF, NiOx/Ni(OH)2@NF, (FeNi)Ox/Ni(OH)2@NF, and (CrNi)Ox/Ni(OH)2@NF electrodes are depicted in Fig. S16,† showing satisfactory electrochemical stability. Overall, the (CoNi)Ox/Ni(OH)2@NF electrode exhibits superior performance in terms of sensitivity, immunity to interference, and stability, making it highly promising for sensitive glucose detection applications. This suggests that (CoNi)Ox/Ni(OH)2@NF, synthesized via the electrochemical oxidation of Ni(OH)2 nanosheets, and incorporated with Co2+ ions, represents a feasible approach for high-performance non-enzyme glucose sensors.
Footnote |
† Electronic supplementary information (ESI) available. See DOI: https://doi.org/10.1039/d4nr04342a |
This journal is © The Royal Society of Chemistry 2025 |