Issue 2, 2012

A study of techniques for the preservation of mercury and other trace elements in water for analysis by inductively coupled plasma mass spectrometry (ICP-MS)

Abstract

The storage of aqueous solutions in high density polyethylene (HDPE) bottles containing nitric acid (0.15 to 2.0% (v/v) was shown to be unsuitable for the preservation of dissolved mercury (Hg2+) either as a single element or as part of a multi-element solution. At concentrations ranging from 0.05 to 10.0 ug l−1 more than 10% of the dissolved mercury was lost within the first three days and up to 50% of the mercury was lost within nine days after solutions were prepared. However mercury was stable in the presence of hydrochloric acid (HCl) or sodium chloride (NaCl). Solutions of either 40 mg l−1NaCl in 0.15% (v/v) nitric acid (HNO3) or 0.01% (v/v) HCl in 1% (v/v) HNO3 were found to be effective for preserving mercury for more than 50 days. The stabilising mechanism is most likely the formation of HgCl42 complex ions that prevent the adsorption of mercury on the inner walls of the HDPE container. The elements Al, Ag, As, Ba, B, Cd, Cr, Co, Cu, Mn, Mo, Ni, Pb, Sb, Se, Tl, V and Zn were stable up to 12 months when preserved in 1.0 to 2.0% (v/v) nitric acid or a mixture of 1% (v/v) HNO3 plus 0.01% (v/v) HCl. The recommended acid combination for the preservation of mercury and multi-elements for the simultaneous determination by ICP-MS is 1% (v/v) HNO3 plus 0.01% (v/v) HCl. Chloride related polyatomic interferences in ICP-MS determination from this acid mixture were less than 0.1 ugl−1 for all elements investigated, making it an ideal preservation medium for ICP-MS analysis.

Graphical abstract: A study of techniques for the preservation of mercury and other trace elements in water for analysis by inductively coupled plasma mass spectrometry (ICP-MS)

Article information

Article type
Paper
Submitted
29 Mar 2011
Accepted
08 Dec 2011
First published
22 Dec 2011

Anal. Methods, 2012,4, 522-529

A study of techniques for the preservation of mercury and other trace elements in water for analysis by inductively coupled plasma mass spectrometry (ICP-MS)

H. Louie, C. Wong, Y. J. Huang and S. Fredrickson, Anal. Methods, 2012, 4, 522 DOI: 10.1039/C2AY05182F

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements