Issue 10, 2012

Characterization and mutual comparison of new electrolytic cell designs for hydride generation-atomic absorption spectrometry with a quartz tube atomizer using Se as a model analyte and 75Se as a radioactive indicator

Abstract

Fifteen electrolytic flow-through cells belonging to three different design groups (non-membrane, thin-layer and tubular) have been constructed and characterized in this work. Atomic absorption spectrometry with a quartz tube atomizer has been employed as a detector and Se chosen as a model analyte. At first optimization of relevant working parameters was performed and basic analytical characteristics were evaluated under the optimum experimental conditions for all cells. Mutual comparisons of the electrolytic cells were performed thereafter and 5 cells with best performance were selected for further evaluation. Finally, a 75Se radioactive indicator was employed to quantify the generation efficiency of selane as well as to visualize the spatial distribution of the analyte in the apparatus and track potential analyte losses. With respect to all relevant requirements the best performance was found for the thin-layer electrolytic cell (225 mm3 cathode chamber volume) with efficiency of electrochemical hydride generation reaching 75% and a limit of detection (LOD) of 0.31 ng mL−1 Se. A generation efficiency of 78% and an LOD of 0.40 ng mL−1 Se were obtained for the tubular cell (43 mm3 cathode volume). High generation efficiency, fast response and low cathode chamber volume make the tubular cell an ideal candidate even for flow-injection and speciation analysis measurements.

Graphical abstract: Characterization and mutual comparison of new electrolytic cell designs for hydride generation-atomic absorption spectrometry with a quartz tube atomizer using Se as a model analyte and 75Se as a radioactive indicator

Article information

Article type
Paper
Submitted
30 May 2012
Accepted
26 Jul 2012
First published
26 Jul 2012

J. Anal. At. Spectrom., 2012,27, 1761-1771

Characterization and mutual comparison of new electrolytic cell designs for hydride generation-atomic absorption spectrometry with a quartz tube atomizer using Se as a model analyte and 75Se as a radioactive indicator

J. Hraníček, V. Červený, J. Kratzer, M. Vobecký and P. Rychlovský, J. Anal. At. Spectrom., 2012, 27, 1761 DOI: 10.1039/C2JA30166K

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements