Issue 11, 2013

Integration of neuraminidase inhibitor assay into a single-step operation using a combinable poly(dimethylsiloxane) capillary sensor

Abstract

The conventional neuraminidase inhibitor assay requiring complicated step-by-step operations was successfully integrated into a “single step” operation using a combinable poly(dimethylsiloxane) (PDMS) capillary (CPC) sensor. In the conventional neuraminidase inhibitor assay, complicated step-by-step operations including initial reaction of an inhibitor and an enzyme, and subsequent reaction with a fluorescent substrate are necessary. Furthermore, optimal pH conditions for the enzymatic reaction differ from those of fluorescence detection. Therefore, preparation of different pH buffer solutions is also essential. To simplify the neuraminidase inhibitor assay into a single-step operation, we applied our recently developed CPC sensor array. Because the CPC sensor allows independent immobilization of different reagents, such as enzymes and fluorescent substrates, simple introduction of an inhibitor solution by capillary action leads to fluorescence emissions. Here, we investigated the optimal pH that enables us to perform the neuraminidase inhibitor assay via a single step operation using the CPC sensor. When the reaction profile was investigated under the optimal pH, the total reaction time was shortened from 1 h to 15 min. Moreover, the neuraminidase inhibitor assay was validated using a typical inhibitor, N-acetyl-2,3-dehydro-2-deoxyneuraminic acid. The inhibition constant, Ki, which was calculated on the basis of the IC50 obtained from the inhibition curve, was in good agreement with the published values. Furthermore, we demonstrated a comparison of fluorescence responses for buffer solutions versus the solution of a well-known influenza drug, Relenza. We observed successful inhibition by Relenza. In addition to the CPC-based approach, the consumption of enzyme, substrate, and inhibitor was reduced to 1% of the amount used in conventional neuraminidase inhibitor assays.

Graphical abstract: Integration of neuraminidase inhibitor assay into a single-step operation using a combinable poly(dimethylsiloxane) capillary sensor

Article information

Article type
Paper
Submitted
01 Dec 2012
Accepted
16 Mar 2013
First published
18 Mar 2013

Analyst, 2013,138, 3158-3162

Integration of neuraminidase inhibitor assay into a single-step operation using a combinable poly(dimethylsiloxane) capillary sensor

T. Ishimoto, K. Jigawa, T. G. Henares, T. Endo and H. Hisamoto, Analyst, 2013, 138, 3158 DOI: 10.1039/C3AN36785A

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements