Issue 16, 2013

Effectiveness of different cleanup sorbents for the determination of avermectins in fish by liquid chromatography tandem mass spectrometry

Abstract

An effectiveness and comparative study of cleanup sorbents used in dispersive solid phase extraction (DSPE) for the determination of avermectins, including emamectin (EMA), abamectin (ABA), doramectin (DOR), moxidectin (MOX), and ivermectin (IVE), was performed. Three different types of cleanup sorbents, alumina (Al), primary and secondary amine (PSA) and octadecyl (C18), were used to remove the matrix interference in fish samples. Homogenised fish samples were extracted with acetonitrile, magnesium sulphate anhydrous and sodium chloride. The cleanup sorbents were separately applied to the supernatant during the DSPE procedure; the mixtures were shaken and centrifuged, and the supernatant was dried. The extracts were reconstituted with acetonitrile/water and quantified by liquid chromatography tandem mass spectrometry with electrospray ionisation in the positive mode with two product ions that were monitored by selected reaction monitoring. The performance of each cleanup sorbent was observed for its accuracy and precision in a spiked blank sample at a concentration of 5 μg kg−1. The combination of the cleanup sorbents PSA and C18 was found to be the most effective in the cleanup of the fish samples. In the validation tests, the detection limit was in the range of 0.3 μg kg−1 to 0.4 μg kg−1, and the quantitation limit for all avermectins was 1 μg kg−1 in the linearity range of 1–15 μg kg−1. The recoveries of avermectins were 91.9–102.5%, with a relative standard deviation lower than 19%.

Graphical abstract: Effectiveness of different cleanup sorbents for the determination of avermectins in fish by liquid chromatography tandem mass spectrometry

Article information

Article type
Paper
Submitted
21 Mar 2013
Accepted
22 May 2013
First published
22 May 2013

Anal. Methods, 2013,5, 4172-4178

Effectiveness of different cleanup sorbents for the determination of avermectins in fish by liquid chromatography tandem mass spectrometry

I. Rafidah, S. Ghanthimathi, A. B. Fatimah and N. A. Mahyudin, Anal. Methods, 2013, 5, 4172 DOI: 10.1039/C3AY40444G

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements