Issue 7, 2013

3D laser ablation-ICP-mass spectrometry mapping for the study of surface layer phenomena – a case study for weathered glass

Abstract

In this work, a multi-elemental 3D laser ablation-ICP-mass spectrometry mapping procedure for high-resolution depth information retrieval to investigate surface layer phenomena is presented. The procedure is based on laser drilling on a virtual grid on the surface, followed by extraction of depth maps along the z-axis (for each element monitored). Using a burst of 50 laser pulses at 1 Hz on each point of the grid, a penetration rate of ca. 150 nm per pulse (in glass) was obtained and a lateral resolution in the order of the laser beam diameter. By ultrafast ICP-MS monitoring of individual ablation pulses (58 ms for a set of 19 elements) using a laser ablation cell with fast signal washout (less than 0.5 s for whole laser pulse), the corresponding peak areas could be consistently integrated, resulting in spatial elemental data associated with individual pulses. The usual laser drilling limitations such as pulse mixing and signal tailing are avoided with this approach. After manipulation of the spatial elemental datasets and quantification, stacks of 50 2D depth maps (for each element monitored) were produced which could be visualized as volume images or time-lapse movies. As a proof of concept, this approach was successfully used to investigate the degradation mechanisms of a medieval, weathered glass artifact by colocalization analysis of selected cross-sectional 2D elemental images in arbitrary planes of the volume images. It was shown that degradation must have started as a result of dealkalinization leading to depletion of alkalis/earth alkalis in glass surface layers and enrichment of network formers (Si and Al), and subsequent worsening by cracking and formation of corrosion pits and so-called spatiotemporal Liesegang rings indicative of radial leaching.

Graphical abstract: 3D laser ablation-ICP-mass spectrometry mapping for the study of surface layer phenomena – a case study for weathered glass

Supplementary files

Article information

Article type
Paper
Submitted
09 Dec 2012
Accepted
25 Feb 2013
First published
25 Feb 2013

J. Anal. At. Spectrom., 2013,28, 994-1004

3D laser ablation-ICP-mass spectrometry mapping for the study of surface layer phenomena – a case study for weathered glass

J. T. van Elteren, A. Izmer, M. Šala, E. F. Orsega, V. S. Šelih, S. Panighello and F. Vanhaecke, J. Anal. At. Spectrom., 2013, 28, 994 DOI: 10.1039/C3JA30362D

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements