Issue 16, 2014

Co-immobilized poly(ethylene glycol)-block-polyamines promote sensitivity and restrict biofouling on gold sensor surface for detecting factor IX in human plasma

Abstract

In order to detect an extremely low amount of human coagulation factor IX (FIX), poly(ethylene glycol) (PEG)/aptamer co-immobilized surface was constructed using original PEG–polyamine surface modification agents on surface plasmon resonance (SPR) sensor chip. Initially, a gold (Au) sensor chip of SPR was modified using poly(ethylene glycol)-b-poly[2-(N,N-dimethylamino)ethyl methacrylate] (PEG-b-PAMA) followed by treatment with SH-dT20 and was duplexed with anti-FIX aptamer extended using A24. Furthermore, the co-immobilization of pentaethylenehexamine-terminated poly(ethylene glycol) (N6-PEG) on the sensing surface completely quenched bio-fouling. On this dual tethered PEG-surface, we determined that the dissociation constant for FIX–aptamer interaction was 37 ± 10 pM, and the sensitivity of detection could reach up to 800 fM on using aptamer–FIX–antibody sandwich pattern detected by gold nanoparticle-conjugated anti-mouse antibody. We could detect FIX in the presence of abundant albumin. Furthermore, to mimic the actual detection of FIX in clinical samples, we demonstrated our experimental results with human blood plasma instead of FIX. Higher-sensitivity was attained because of dual polymers immobilized on Au surface, and this can emerge as a common strategy for any aptamer–protein interactions. The selective binding of aptamer in human blood plasma described here indicates the suitability of the present strategy for detection in clinically relevant samples.

Graphical abstract: Co-immobilized poly(ethylene glycol)-block-polyamines promote sensitivity and restrict biofouling on gold sensor surface for detecting factor IX in human plasma

Supplementary files

Article information

Article type
Paper
Submitted
23 Jan 2014
Accepted
18 May 2014
First published
19 May 2014

Analyst, 2014,139, 3977-3985

Author version available

Co-immobilized poly(ethylene glycol)-block-polyamines promote sensitivity and restrict biofouling on gold sensor surface for detecting factor IX in human plasma

T. Lakshmipriya, Y. Horiguchi and Y. Nagasaki, Analyst, 2014, 139, 3977 DOI: 10.1039/C4AN00168K

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements