Issue 21, 2014

An electrochemical DNA biosensor for the detection of Mycobacterium tuberculosis, based on signal amplification of graphene and a gold nanoparticle–polyaniline nanocomposite

Abstract

Due to its low growth rate and its fastidious nature, Mycobacterium tuberculosis is difficult to identify. Its rapid and sensitive detection is, however, critical for the control of tuberculosis. Molecular biology, and more recently electrochemical technology, have been exploited for the detection of this pathogen. In the present study, a novel DNA biosensor was developed for the highly sensitive detection of the specific DNA insertion sequence IS6110 of M. tuberculosis, using reduced graphene oxide–gold nanoparticles (rGO–AuNPs) as a sensing platform and gold nanoparticles–polyaniline (Au–PANI) as a tracer label for amplification. Reduced graphene oxide, which has a large surface area, provided a biocompatible matrix. Gold nanoparticles were electrodeposited on the surface of the rGO modified electrode, which not only increased immobilisation of the capture probe but also promoted electronic transfer. The Au–PANI nanocomposite exhibited good biocompatibility and excellent electrochemical activity. It was therefore used as a tracer label for electrochemical detection, which provided a simple preparation process for a signal-on DNA biosensor. With the excellent electroactivity of the Au–PANI nanocomposite, the resulting DNA biosensor exhibited high sensitivity for the detection of M. tuberculosis over a broad linear range, between 1.0 × 10−15 and 1.0 × 10−9 M. The DNA biosensor showed good stability and high specificity and provides a new strategy for clinical M. tuberculosis diagnostics and probably also for pathogenic bacteria in general.

Graphical abstract: An electrochemical DNA biosensor for the detection of Mycobacterium tuberculosis, based on signal amplification of graphene and a gold nanoparticle–polyaniline nanocomposite

Article information

Article type
Paper
Submitted
29 May 2014
Accepted
31 Jul 2014
First published
31 Jul 2014

Analyst, 2014,139, 5460-5465

An electrochemical DNA biosensor for the detection of Mycobacterium tuberculosis, based on signal amplification of graphene and a gold nanoparticle–polyaniline nanocomposite

C. Liu, D. Jiang, G. Xiang, L. Liu, F. Liu and X. Pu, Analyst, 2014, 139, 5460 DOI: 10.1039/C4AN00976B

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements