Issue 3, 2015

Photoelectrochemical glucose biosensor in flow injection analysis system based on glucose dehydrogenase immobilized on poly-hematoxylin modified glassy carbon electrode

Abstract

In this study, a photoelectrochemical glucose biosensor is presented, comprising electropolymerized hematoxylin film on poly-amidoamine (PAMAM) dendrimers adsorbed on glassy carbon electrode (poly-HT/PAMAM/GCE). After immobilization of glucose dehydrogenase (GDH) onto the poly-HT/PAMAM/GCE, photoelectrochemical biosensing of glucose was investigated using cyclic voltammetry and amperometry in a flow injection analysis (FIA) system dependent on the NAD+/NADH redox couple-dehydrogenase enzyme. The linear range was from 1 × 10−5 M to 1 × 10−3 M with a sensitivity of 0.76 μA mM−1 and detection limit of 3.0 μM without irradiation in the FIA system. After irradiation, the linear range was from 5 × 10−6 M to 1 × 10−3 M with a sensitivity of 1.90 μA mM−1 and a detection limit of 1.5 μM. Comparing the results obtained from irradiation of the electrode surface with those from the reaction without irradiation, the sensitivity and the detection limit increased around 2.5- and 2.0-fold, respectively. The photoelectrochemical biosensor showed good performance with high upper detection limit, acceptable repeatability, and selectivity, providing a rapid alternative method for monitoring biomolecules and extending photoelectrochemical determination in the FIA system. The proposed electrochemical and photoelectrochemical biosensor was successfully applied to determination of glucose in real samples. The results obtained from this study provide a basis for future studies in these directions.

Graphical abstract: Photoelectrochemical glucose biosensor in flow injection analysis system based on glucose dehydrogenase immobilized on poly-hematoxylin modified glassy carbon electrode

Supplementary files

Article information

Article type
Paper
Submitted
25 Sep 2014
Accepted
11 Nov 2014
First published
27 Nov 2014

Anal. Methods, 2015,7, 990-999

Author version available

Photoelectrochemical glucose biosensor in flow injection analysis system based on glucose dehydrogenase immobilized on poly-hematoxylin modified glassy carbon electrode

D. G. Dilgin and H. İ. Gökçel, Anal. Methods, 2015, 7, 990 DOI: 10.1039/C4AY02269F

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements