Issue 20, 2015

Analysis of oxybutynin and N-desethyloxybutynin in human urine by dispersive liquid–liquid microextraction (DLLME) and capillary electrophoresis (CE)

Abstract

A dispersive liquid–liquid microextraction (DLLME) procedure combined with capillary electrophoresis/diode array detection (CE/DAD) was developed and applied to the determination of oxybutynin (OXY) and N-desethyloxybutynin (DEO) in human urine. The electrophoretic analyses were performed using a 50 μm i.d. fused silica uncoated capillary with an effective length of 36.5 cm and a 50 mmol L−1 solution of triethylamine, pH 3.0, as the background electrolyte. The temperature was set at 30 °C and a constant voltage of +30 kV was applied. Some experimental parameters that affect DLLME's extraction efficiency, such as the type and volume of the extraction and disperser solvents, extraction time and pH, were studied and optimized. The optimal DLLME conditions were found using the following method: 2.5% (w/v) NaCl was added to 5.0 mL of urine, the pH was adjusted to 11.0 and 140 μL of carbon tetrachloride as the extraction solvent and 260 μL of acetonitrile as the disperser solvent were quickly added. The performance criteria for linearity, sensitivity, precision, accuracy, recovery and stability have been assessed and they were within the Guidance for Industry: Bioanalytical Method Validation. The mean extraction recoveries for OXY and DEO were 71.4% (SD 6.4%) and 60.9% (SD 8.5%), respectively. The method showed linearity over the concentration range of 90–300 ng mL−1 and 187.5–750 ng mL−1, with correlation coefficients of 0.990 and 0.998 for OXY and DEO, respectively. Intra-day and inter-day precision and accuracy assays for these analytes were studied at three concentration levels and were lower than 15%.

Graphical abstract: Analysis of oxybutynin and N-desethyloxybutynin in human urine by dispersive liquid–liquid microextraction (DLLME) and capillary electrophoresis (CE)

Article information

Article type
Paper
Submitted
25 Jun 2015
Accepted
30 Aug 2015
First published
21 Sep 2015

Anal. Methods, 2015,7, 8763-8770

Author version available

Analysis of oxybutynin and N-desethyloxybutynin in human urine by dispersive liquid–liquid microextraction (DLLME) and capillary electrophoresis (CE)

B. J. Moreira, K. B. Borges, A. R. M. de Oliveira and C. M. de Gaitani, Anal. Methods, 2015, 7, 8763 DOI: 10.1039/C5AY01641J

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements