Issue 4, 2015

Effect of the orientation and fluid flow on the accumulation of organotin compounds to Chemcatcher passive samplers

Abstract

Monitoring of harmful substances in an aquatic environment is based on spot sampling which is the only sampling technique accepted by environmental authorities in the European Union. Still the implementation of the European Union Water Framework Directive (WFD) requires novel sampling tools for monitoring priority pollutants since their concentrations in natural waters can often remain below the limit of detection when using the conventional spot sampling method. However, this does not necessarily mean that the pollutant is not present in the aquatic environment. Many chemicals that are considered to be harmful are bioaccumulative and can affect, e.g., reproduction of aquatic organisms even at very low concentration levels. Also the timing is crucial since with spot sampling the pulse of harmful substances can easily be missed. Passive samplers collect the compounds for a certain amount of time which allows the concentrations in the sampler to rise to the measurable level where they are easy to detect. Organotin compounds (OTCs) have been widely used as plastic stabilizers and antifouling agents in ship paints and in many industrial processes. Among the OTCs, tributyltin is listed as a WFD priority substance. In this study a small-scale flow simulation around the Chemcatcher passive sampler was performed to visualize the flow streamlines in the vicinity of the sampler and to study the pressure experienced by the receiving phase in different sampler positions. With laboratory experiments the sampling rates for each OTC were determined and the effect of the flow velocity and sampler orientation on the accumulation of OTCs is discussed. The pressure changes were observed on the surface of the receiving phase in simulations with varying sampler orientations. Despite that, the laboratory experiments discovered no difference in the accumulation of compounds when varying the sampler orientation. The concentrations of OTCs in the surrounding water calculated from the passive sampling results were equivalent to the spot sampling ones. Hence, the Chemcatcher passive sampler provides a practical tool for the implementation of WFD.

Graphical abstract: Effect of the orientation and fluid flow on the accumulation of organotin compounds to Chemcatcher passive samplers

Associated articles

Article information

Article type
Paper
Submitted
03 Nov 2014
Accepted
23 Feb 2015
First published
24 Feb 2015

Environ. Sci.: Processes Impacts, 2015,17, 813-824

Effect of the orientation and fluid flow on the accumulation of organotin compounds to Chemcatcher passive samplers

H. Ahkola, J. Juntunen, M. Laitinen, K. Krogerus, T. Huttula, S. Herve and A. Witick, Environ. Sci.: Processes Impacts, 2015, 17, 813 DOI: 10.1039/C4EM00585F

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.